Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear radiation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Measurement of the branching ratio of 16 N , 15 C , 12 B , and 13 B isotopes through the nuclear muon capture reaction in the Super-Kamiokande detector

The Super-Kamiokande detector has measured solar neutrinos for more than 25 years. The sensitivity for solar neutrino measurement is limited by the uncertainties of energy scale and background modeling. Decays of unstable isotopes with relatively long half-lives through nuclear muon capture, such as 16 N, 15 C, 12 B, and 13 B, are detected as background events for solar neutrino observations. Here, in this study, we developed a method to form a pair of stopping muon and decay candidate events and evaluated the production rates of such unstable isotopes. We then measured their branching ratios considering both their production rates and the estimated number of nuclear muon capture processes as Br⁡( 16 N) = (9.0 ± 0.1)%, Br⁡( 15 C) = (0.6 ± 0.1)%, Br⁡( 12 B) = (0.98 ± 0.18)%, Br⁡( 13 B) = (0.14 ± 0.12)%, respectively. The result for 16 N has world-leading precision at present and the results for 15 C, 12 B, and 13 B are the first branching ratio measurements for those isotopes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DRiFT current mode, trigger settings and flexible detector specifications applied to scintillator arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Gamma radiation background measurements from Spacelab 2

A Nuclear Radiation Monitor incorporating a NaI(Tl) scintillation detector was flown as part of the verification flight instrumentation on the Spacelab 2 mission, July 29 to August 6, 1985. Gamma-ray spectra were measured with better than 20 s resolution throughout most of the mission in the energy range 0.1 to 30 MeV. Knowledge of the decay characteristics and the geomagnetic dependence of the counting rates enable measurement of the various components of the Spacelab gamma-ray background: prompt secondary radiation, Earth albedo, and delayed induced radioactivity. The status of the data analysis and present relevant examples of typical background behavior are covered.

Paciesas, William S.↗

Gamma radiation background measurements from Spacelab 2

A Nuclear Radiation Monitor incorporating a NaI(Tl) scintillation detector was flown as part of the verification flight instrumentation on the Spacelab 2 mission, July 29 to August 6, 1985. Gamma-ray spectra were measured with better than 20 s resolution throughout most of the mission in the energy range 0.1 to 30 MeV. Knowledge of the decay characteristics and the geomagnetic dependence of the counting rates enable measurement of the various components of the Spacelab gamma-ray background: prompt secondary radiation, earth albedo, and delayed induced radioactivity. The status of the data analysis and present relevant examples of typical background behavior are covered.

Paciesas, William S.↗

Observation of cosmic-ray particles with Z of 50 or greater and interpretation of the charge spectrum.

Large areas of plastic detectors and nuclear emulsions were exposed to the primary cosmic radiation on two high-altitude balloon flights in May 1968 and September 1969. From measurements on the tracks found in the scanning of the plastic detectors, events with charges Z greater than 50 were selected, and these data were consolidated with those from our earlier flights. Several conclusions can be drawn from the observed charge spectrum. The detection of trans-bismuth nuclei confirms earlier observations of these particles in the cosmic rays. However, no trans-uranium particles were observed. Detailed features of the charge spectrum cannot be explained by nuclei from r-process nucleosynthesis alone. Although the addition of particles following s-process abundances yields improved agreement, the spectrum appears more complicated than would result from a simple combination of r- and s-process abundances with identical propagation histories.

Blanford, G. E., Jr.↗

Gamma single-hit detector for NDSE

2021 annual project report for SDRD Program. Edited and approved by author. Will be made available on SDRD website in future. An associated abstract/summary for this longer report will be submitted to STIP as well.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determining g A / g V with High-Resolution Spectral Measurements Using a LiInSe 2 Bolometer

Neutrinoless double beta decay (0νββ) processes sample a wide range of intermediate forbidden nuclear transitions, which may be impacted by quenching of the axial vector coupling constant (g A /g V ), the uncertainty of which plays a pivotal role in determining the sensitivity reach of 0νββ experiments. Here we present measurements performed on a high-resolution LiInSe 2 bolometer in a “source = detector” configuration to measure the spectral shape of the fourfold forbidden β decay of 115 In . The value of g A /g V is determined by comparing the spectral shape of theoretical predictions to the experimental β spectrum taking into account various simulated background components as well as a variety of detector effects. We find evidence of quenching of g A /g V at >5 σ with a model-dependent quenching factor of 0.655 ± 0.002 as compared to the free-nucleon value for the interacting shell model. We also measured the 115 In half-life to be [5.18 ± 0.06(stat) $^{+0.005}_{- 0.015}$(sys)] x 10 14 yr within the interacting shell model framework. This Letter demonstrates the power of the bolometeric technique to perform precision nuclear physics single-β decay measurements, which along with improved nuclear modeling can help reduce the uncertainties in the calculation of several decay nuclear matrix elements including those used in 0νββ sensitivity calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray detector physics and applications; Proceedings of the Meeting, San Diego, CA, July 23, 24, 1992

Recent developments in X-ray and hard X-ray imaging detector, high-intensity sources, hard X-ray imaging optics, calibration, and detection technologies are discussed. Particular attention is given to a high-MTF X-ray image intensifier, application of monolithic CdZnTe linear solid state ionization detectors for X-ray imaging, magnetic response of high-Tc superconductors to X-ray radiation and detection of X-rays, laboratory soft X-ray source with foil target, detection of explosive materials using nuclear radiation, energy response of astronomical CCD X-ray detectors, calibration techniques for high-flux X-ray detectors, fabrication of grazing-incidence optics using flow-polishing techniques, and numerical simulations for capillary-based X-ray optics. (No individual items are abstracted in this volume)

Hoover, Richard B.↗

Pulse-shape analysis in Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 room-temperature radiation detectors

The effect of trapping of charge carriers on the shape of the charge pulses from room temperature nuclear detectors, based on a recently discovered quaternary semiconductor Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 (CZTS), has been studied. Here, we present a charge-trapping model that explains the pulse shapes for its entire duration from radiation detectors containing multiple defect types. A piecewise continuous model, based on the movement of a large number of charge carriers rather than a single charge, has been proposed to explain the pulse shapes from planar room temperature nuclear detectors. An experimental method based on the model has been described to extract charge-trapping information. This model can be applied to similar semiconductor detectors with electrically active trap centers, in general, to extract information like pre-trapping drift times. Charge pulses from a CZTS planar detector, exposed to 5486 keV alpha particles emitted by a 241Am source, were acquired using a digitizer, and the pulse shapes were explained based on the proposed model. The pre-trapping drift times for electrons as well as holes in CZTS were calculated and studied as a function of operating bias voltage, and a contrast between their bias dependent behaviors was noticed, indicating the behavioral difference of electron and hole traps.

42 ENGINEERING↗

The 3 He BF 3 Giant Barrel (HeBGB) neutron detector

(α,n) reactions play an important role in nuclear astrophysics and applications and are an important background source in neutrino and dark matter detectors. Measurements of total (α,n) cross sections employing direct neutron detection often have a considerable systematic uncertainty associated with the energy-dependent neutron detection efficiency and the unknown initial neutron energy distribution. Furthermore, the 3 He BF 3 Giant Barrel (HeBGB) neutron detector was built at the Edwards Accelerator Laboratory at Ohio University to overcome this challenge. HeBGB offers a near-constant neutron detection efficiency of (7.5 ± 1.2)% over the neutron energy range 0.01 MeV–9.00 MeV, removing a significant source of systematic uncertainty present in earlier (α,n) cross section measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermodynamic stability of xenon-doped liquid argon detectors

Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we analyze the causes of these instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with $\mathscr{O}$ (1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. In conclusion, this work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A demonstrator for a real-time AI-FPGA-based triggering system for sPHENIX at RHIC

The RHIC interaction rate at sPHENIX will reach around 3 MHz in pp collisions and requires the detector readout to reject events by a factor of over 200 to fit the DAQ bandwidth of 15 kHz. Some critical measurements, such as heavy flavor production in pp collisions, often require the analysis of particles produced at low momentum. This prohibits adopting the traditional approach, where data rates are reduced through triggering on rare high momentum probes. We explore a new approach based on real-time AI technology, adopt an FPGA-based implementation using a custom designed FELIX-712 board with the Xilinx Kintex Ultrascale FPGA, and deploy the system in the detector readout electronics loop for real-time trigger decision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Interdiction Through Relocatable Detectors

The NNSA Office of Nuclear Smuggling Detection and Deterrence (NSDD) has investigated a set of minimal-infrastructure radiation detection systems as alternatives to fixed Radiation Portal Monitors (RPMs) for nuclear interdiction applications. These versatile and relocatable systems can improve nuclear security in missions or locations that do not warrant or support a standard fixed radiation detection system. Over 2019, a variety of relocatable detectors were characterized at the Interdiction Technologies Integration Laboratory at Pacific Northwest National Laboratory (PNNL). Evaluated detectors were diverse in their size and capabilities, ranging from backpack-sized systems to lane-spanning cargo scanning portals. Both spectroscopic and non-spectroscopic pedestrian and vehicle detection systems were characterized against uranium and plutonium sources. Signatures from the sources were modulated by both shielding and distance to quantify the performance of the relocatable systems as signal strength was decreased. Findings showed that relocatable spectroscopic detectors with isotope identification capabilities could reduce nuisance alarm rates compared to conventional fixed installation, gross-counting, radiation portal monitors. In vehicle scanning applications, detection ability generally trended with detection volume, regardless of spectral capability. In pedestrian scanning applications, several smaller backpack-sized detector systems were found to be more sensitive to detecting material than pedestrian portal monitors. The results of this characterization effort have helped inform the deployment of versatile equipment to improve nuclear security missions.

relocatable detectors, Nuclear Security↗

Precision pulse shape simulation for proton detection at the Nab experiment

The Nab experiment at Oak Ridge National Laboratory, USA, aims to measure the beta-antineutrino angular correlation following neutron β decay to an anticipated precision of approximately 0.1%. The proton momentum is reconstructed through proton time-of-flight measurements, and potential systematic biases in the timing reconstruction due to detector effects must be controlled at the nanosecond level. In conclusion, we present a thorough and detailed semiconductor and quasiparticle transport simulation effort to provide precise pulse shapes, and report on relevant systematic effects and potential measurement schemes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of uranium-photofission neutrons with a 4 He scintillation detector

The use of photon active interrogation to detect special nuclear material has held significant theoretical promise, as the interrogating source particles, photons, are fundamentally different from one of the main signatures of special nuclear material: neutrons produced in nuclear fission. However, neutrons produced by photonuclear reactions in the accelerator target, collimator, and environment can obscure the fission neutron signal. These (γ, n) neutrons could be discriminated from fission neutrons by their energy spectrum, but common detectors sensitive to the neutron spectrum, like organic scintillators, are typically hampered by the intense photon background characteristic of photon-based active interrogation. In contrast, high-pressure 4 ⁢He-based scintillation detectors are well-suited to photon active interrogation, as they are similarly sensitive to fast neutrons and can measure their spectrum, but show little response to gamma rays. Here, in this work, a photon active interrogation system utilizing a 4 ⁢He scintillation detector and a 9 MeV linac-bremsstrahlung x-ray source was experimentally evaluated. The detector was shown to be capable of operating in intense gamma-ray environments and detecting photofission neutrons from 238 ⁢U when interrogated by this x-ray source. The photofission neutrons show clear spectral separation from (γ, n) neutrons produced in lead, a common shielding material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗