Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear radiation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The CLAS12 Ring Imaging Cherenkov Detector

A ring imaging Cherenkov (RICH) detector has been installed in the CLAS12 spectrometer at Jefferson Laboratory (JLab) to provide kaon identification in the momentum range between 3 GeV/c and 8 GeV/c. The detector adopts a hybrid optics solution with aerogel radiator, light planar and spherical mirrors, and highly segmented photon detectors. We report here on the design, construction, and initial performance of the RICH during the commissioning of the detector and the first physics data taking period

PID detectors↗

The Urban Deployment Model: A Toolset for the Simulation and Performance Characterization of Radiation Detector Deployments in Urban Environments

Static and mobile radiation detectors can be deployed in urban environments for a range of nuclear security applications, including radiological source search-and-tracking scenarios. Modeling detector performance for such applications is challenging, as it does not depend solely on the detector capabilities themselves. Many factors must be taken into consideration, including specific source and background signatures, the topology and constraints of the deployment environment, the presence of nuisance sources, and whether detectors are mobile or static. When considering the simultaneous deployment of multiple, heterogeneous detectors, assessment of the system-wide performance requires the simulation of the individual detectors, and a system-level analysis of the detection performance. In radiological source search-and-tracking scenarios, performance is mostly dominated by the probability of encounter, which depends on the specifics of a given deployment, e.g., static vs. mobile detectors or a combination of both modalities, the number of detectors deployed, the dynamic vs. static setting of false alarm rates, and individual vs. networked operation. The Urban Deployment Model (UDM) toolset was specifically developed to cover the gap in the available generic frameworks for the simulation of radiation detector deployments at city scales. UDM provides a unified and modular framework to support the simulation and performance characterization of heterogeneous detector deployments in urban environments. This paper presents the key components along the UDM workflow.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Neutron time of flight (nToF) detectors for inertial fusion experiments

Neutrons generated in Inertial Confinement Fusion (ICF) experiments provide valuable information to interpret the conditions reached in the plasma. The neutron time-of-flight (nToF) technique is well suited for measuring the neutron energy spectrum due to the short time (100 ps) over which neutrons are typically emitted in ICF experiments. By locating detectors 10s of meters from the source, the neutron energy spectrum can be measured to high precision. Here, we present a contextual review of the current state of the art in nToF detectors at ICF facilities in the United States, outlining the physics that can be measured, the detector technologies currently deployed and analysis techniques used.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time-of-flight experiments for nuclear structure and astrophysics

Neutron-rich isotopes are atomic nuclei with a large neutron excess compared to their stable counter parts. Their study provides essential information to understand the properties of the nuclear interaction, and to model nuclear processes in extreme astrophysical environments where neutron-rich isotopes drive the chains of nuclear reactions. Experimentally, these unstable isotopes are difficult to study because of their short half-lives and low production yields at particle accelerator laboratories. The TOF-Bρ technique is a mass measurement technique specialized for experiments with fast beams of short-lived radioactive isotopes. In this project we used the technique for two experiments performed at the National Superconducting Cyclotron Laboratory to measure new masses of isotopes in the region of 112 Mo and 46 S. The experiments at the NSCL were complemented by the development of new timing radiation detectors and experimental techniques to improve the performance and reach of mass measurements on neutron-rich isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Coincident CdTe Detector Array for Enhanced Nuclear Process Monitoring

Nuclear fuel cycle aqueous separation processes desire improved real-time material characterization and process monitoring techniques; gamma coincidence spectroscopy has the potential to meet this need in these high throughput and high radiation environments based on its ability to reduce background noise, thereby enhancing detection limits and improving isotopic identification accuracy. A detector array composed of three CdTe detectors was designed to surround a chemical processing pipe in a reprocessing facility and evaluate the feasibility of passively assaying the nuclear materials flowing though this measurement point. This array uses commercial off the shelf components that are radiation hard and highly efficiency at low energies relevant to actinide photon signatures. Detector efficiency characterizations, coincidence detection, and potential configuration improvements are presented here.

Good, Erin C.↗

SNM Radiation Signature Classification Using Different Semi-Supervised Machine Learning Models

The timely detection of special nuclear material (SNM) transfers between nuclear facilities is an important monitoring objective in nuclear nonproliferation. Persistent monitoring enabled by successful detection and characterization of radiological material movements could greatly enhance the nuclear nonproliferation mission in a range of applications. Supervised machine learning can be used to signal detections when material is present if a model is trained on sufficient volumes of labeled measurements. However, the nuclear monitoring data needed to train robust machine learning models can be costly to label since radiation spectra may require strict scrutiny for characterization. Therefore, this work investigates the application of semi-supervised learning to utilize both labeled and unlabeled data. As a demonstration experiment, radiation measurements from sodium iodide (NaI) detectors are provided by the Multi-Informatics for Nuclear Operating Scenarios (MINOS) venture at Oak Ridge National Laboratory (ORNL) as sample data. Anomalous measurements are identified using a method of statistical hypothesis testing. After background estimation, an energy-dependent spectroscopic analysis is used to characterize an anomaly based on its radiation signatures. In the absence of ground-truth information, a labeling heuristic provides data necessary for training and testing machine learning models. Supervised logistic regression serves as a baseline to compare three semi-supervised machine learning models: co-training, label propagation, and a convolutional neural network (CNN). In each case, the semi-supervised models outperform logistic regression, suggesting that unlabeled data can be valuable when training and demonstrating value in semi-supervised nonproliferation implementations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Measurement of the sodium and iodine scintillation quenching factors across multiple NaI(Tl) detectors to identify systematics

The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for weakly interacting massive particles (WIMP) searches and coherent elastic neutrino-nucleus scattering ( CE ν NS ) measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among the current measurements of the quenching factor in sodium iodide (NaI) crystals, especially below 10 keV, the energy region of interest for dark matter and CE ν NS studies. A better understanding of the quenching factor in NaI(Tl) is of particular interest for resolving the decades-old puzzle in the field of dark matter between the null results of most WIMP searches and the claim for dark matter detection by the DAMA/LIBRA collaboration. In this work, we measured sodium and iodine quenching factors for five small NaI(Tl) crystals grown with similar thallium concentrations and growth procedures. Unlike previous experiments, multiple crystals were tested, with measurements made in the same experimental setup to control systematic effects. The quenching factors agree in all crystals we investigated, and both sodium and iodine quenching factors are smaller than those reported by DAMA/LIBRA. The dominant systematic effect was due to the electron equivalent energy calibration originating from the nonproportional behavior of the NaI(Tl) light yield at lower energies, potentially the cause for the discrepancies among the previous measurements. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Maximum Likelihood Spectrum Decomposition for Isotope Identification and Quantification

A spectral decomposition method has been implemented to identify and quantify isotopic source terms in high-resolution gamma-ray spectroscopy in static geometry and shielding scenarios. Monte Carlo simulations were used to build the response matrix of a shielded high-purity germanium detector monitoring an effluent stream with a Marinelli configuration. The decomposition technique was applied to a series of calibration spectra taken with the detector using a multi-nuclide standard. These results are compared with decay-corrected values from the calibration certificate. For most nuclei in the standard ( 241 Am, 109 Cd, 137 Cs, and 60 Co), the deviations from the certificate values were generally no more than 6% with a few outliers as high as 10%. Furthermore, for 57 Co, the radionuclide with the lowest activity, the deviations from the standard reached as high as 25%, driven by the meager statistics in the calibration spectra. In addition, a complete treatment of error propagation for the technique is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neural MUSE Analysis

Researchers at Oak Ridge National Laboratory (ORNL) created data as part of the MUSE (Multi-Agency Urban Search Experiment Detector and Algorithm Test Bed) project simulating illicit nuclear materials located in various buildings along a road. In the simulation, a truck containing a radiation detector drives down the road gathering listmode data (counting the and energy of incident gamma radiation). Building materials, source shielding, driving speed, truck direction, truck location on the road, source type, and source placement are all varied between runs of the data set. This data was created using deterministic neutron transport and Monte Carlo methods through a combination of SCALE, MAVRIC, MCNP, and GADRAS. As part of a follow-on NA-22 project, two Kaggle competitions were created to determine the best algorithms for finding and identifying gamma sources in this simulated urban environment. The winning algorithm was neural network-based and had a test accuracy of 76.4% accuracy for source identification. This work seeks to build upon this work and improve the results through the application of novel machine learning techniques. As a first step, the data was classified by a simple Convolutional Neural Network (CNN) To accomplish this, the data was first preprocessed into “waterfall plots.” These plots are composed of energy vs count plots that are stacked vertically to show progression in time. The horizontal axis indicating the particle energy incorporated user defined bin spacing with options for in linear-, logarithmic-, square root-, and user-spaced bins. The z or color dimension showed the number of counts corresponding the energy-time combination. This data was then used to generate more data, by generating a local estimate of the mean of the distribution for a bin and then randomly re-sampling that bin from a Poisson distribution. Once all of this data was generated, it was fed into a well-known CNN architecture, ResNet50. The output layer of this model was removed and replaced with layers corresponding to the shape desired isotope outputs. The provided training data was used to train the classifier and the remaining testing data was used to evaluate the model. Results are soon to be forthcoming.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reactor neutrino applications and coherent elastic neutrino nucleus scattering

Potential applications of neutrino detection to nuclear security have been discussed since the 1970s. Recent years have seen great progress in detector technologies based on inverse beta decay, with the demonstration of ton-scale surface-level detectors capable of high quality neutrino spectrum measurements. At the same time coherent elastic neutrino nucleus scattering has been experimentally confirmed in 2017 with neutrinos from stopped pion decay and there is a number of experiments aimed at seeing this reaction with reactor neutrinos. Here, the large cross section and threshold-less nature of this reaction make it plausible to consider it for applications to nuclear security and here, we present a first direct comparison of the two reaction modes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Capacitively Coupled LAPPDs with 2D Pixelated Readout Planes for Time of Flight and Ring Imaging Cherenkov Applications

Large Area Picosecond Photon Detectors (LAPPDs) are micro-channel plate based photosensors featuring hundreds of square centimeters of sensitive area in a single package and capable of providing timing resolution on the order of 50 ps for single photon detection. However, LAPPDs currently do not exist in finely pixelated 2D readout configurations which, in addition to ighresolution timing, would also provide high spatial resolution required for Ring Imaging CHerenkov (RICH) detectors. One of the recent LAPPD models (Gen II) provides the opportunity to overcome the lack of pixellation by coupling an external readout to the sealed detector itself. The readout plane in this case is a simple printed circuit board (PCB) that can be laid out in a custom application-specific way for 1D or 2D sensitive area pixellation. This allows for a much shorter readout-plane prototyping cycle and provides unprecedented flexibility in choosing an appropriate segmentation that can be optimized for any particular detector need in terms of pad size, orientation, and shape.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Joint Measurement of the 235 U Antineutrino Spectrum by PROSPECT and STEREO

The PROSPECT and STEREO collaborations present a combined measurement of the pure 235 U antineutrino spectrum, without site specific corrections or detector-dependent effects. The spectral measurements of the two highest precision experiments at research reactors are found to be compatible with χ 2 /ndf = 24.1/21, allowing a joint unfolding of the prompt energy measurements into antineutrino energy. This $\bar{ν}_e$ energy spectrum is provided to the community, and an excess of events relative to the Huber model is found in the 5-6 MeV region. When a Gaussian bump is fitted to the excess, the data-model χ 2 value is improved, corresponding to a 2.4σ significance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Internship In ISR-1 [Slides]

ISR-1 is the Space Science and Applications division, so much of what we work with involves satellites, detectors, electronics, radiation, etc.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Results of the LEGEND-200 experiment in the search for $0νββ$ decay

The LEGEND experiment is looking for the extremely rare neutrinoless double beta (0νββ) decay of 76 Ge using isotopically-enriched high-purity germanium (HPGe) detectors. The detection of this process would imply that the neutrino is a Majorana particle and the total lepton number would not be conserved, which could be related to the cosmological asymmetry between matter and antimatter through leptogenesis. The long-term goal of the collaboration is LEGEND-1000: a 1-ton detector array planned to run for 10 years, with a projected half-life sensitivity exceeding 10 28 years, fully covering the inverted neutrino mass hierarchy. A first search for the 0νββ decay has been carried out by LEGEND-200 building on the experience gained from GERDA and the MAJORANA DEMONSTRATOR. The experiment has been collecting physics data for a year at the Gran Sasso National Laboratory in Italy with 140 kg of HPGe detectors. With a total exposure of 61 kg yr, LEGEND-200 has achieved a background index of $5_{−2}^{+3}$ × 10 −4 counts/(keV kg yr) in the 0νββ decay signal region from the highest performing detectors. After combining the results from GERDA, the MAJORANA Demonstrator and LEGEND-200, an exclusion sensitivity > 2.8 × 10 26 yr has been obtained at 90% confidence level for the 0νββ decay half-life, with no evidence for a signal. A new observed lower limit of $T_{1/2}^{0v} >$ 1.9 × 10 26 yr at 90% confidence level has been established.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗