Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

DABAM: An open-source database of X-ray mirrors metrology

An open-source database containing metrology data for X-ray mirrors is presented. It makes available metrology data (mirror heights and slopes profiles) that can be used with simulation tools for calculating the effects of optical surface errors in the performances of an optical instrument, such as a synchrotron beamline. A typical case is the degradation of the intensity profile at the focal position in a beamline due to mirror surface errors. This database for metrology (DABAM) aims to provide to the users of simulation tools the data of real mirrors. The data included in the database are described in this paper, with details of how the mirror parameters are stored. An accompanying software is provided to allow simple access and processing of these data, calculate the most usual statistical parameters, and also include the option of creating input files for most used simulation codes. In conclusion, some optics simulations are presented and discussed to illustrate the real use of the profiles from the database.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4, Volume IV: Inherent Optical Properties: Instruments, Characterizations, Field Measurements and Data Analysis Protocols

This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparision and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background, and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 is entirely superseded by the six volumes of Revision 4 listed above.

Mueller, J. L.↗

Ocean Optics Protocols for Satellite Ocean Color Sensor Validation: Inherent Optical Properties: Instruments, Characterizations, Field Measurements and Data Analysis Protocols - Volume 4

This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.

Mueller, J. L.↗

Advances in Time Resolved X-ray Excited Optical Luminescence Instrumentation at the Canadian Light Source

Measurement of the optical emission properties of samples excited by x-rays can be used to study defect states in crystals and the optical properties of nanostructured materials. Changes in the intensities, wavelengths and lifetimes of the optical emission can occur when specific core level electrons are excited using tuneable light from a synchrotron light source. At the Canadian Light Source (CLS), collaboration between the user community, the experimental facilities group and the accelerator division has resulted in improved capabilities in the acquisition of Time Resolved XEOL (TRXEOL) data. Using a streak camera, the optical luminescence decay curves from samples excited with 35 ps long synchrotron pulses have been obtained. The streak tube is operated in single sweep mode and is triggered by the 500 MHz RF signal, which has been resynchronized to the orbit clock frequency giving a highly stable trigger pulse. A transverse kicker system is used to improve bunch purity from 10{sup 2} to 10{sup 6}. The decay curves of the XEOL of nanostructured ZnO and a high pressure form of SiO{sub 2} have been measured and demonstrate the unique capabilities of this instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Simple Approach of CCD Camera Calibration for Optical Diagnostics Instrumentation

Solid State array sensors are ubiquitous nowadays for obtaining gross field images in numerous scientific and engineering applications including optical diagnostics and instrumentation. Linear responses of these sensors are often required as in interferometry, light scattering and attenuation measurements, and photometry. In most applications, the linearity is usually taken to be granted without thorough quantitative assessment or correction through calibration. Upper-grade CCD cameras of high price may offer better linearity: however, they also require linearity checking and correction if necessary. Intermediate- or low-grade CCD cameras are more likely to need calibration for linearity . Here, we present two very simple approaches: one for quickly checking camera linearity without any additional setup and one for precisely correcting nonlinear sensor responses. It is believed that after calibration, those sensors of intermediate or low grade can function as effectively as their expensive counterpart.

Cha, Soyoung Stephen↗

Modular removable precision mechanism for alignment of an FUV spatial heterodyne interferometer

Spaceflight optical instruments have two conflicting requirements. They need to be both rigid and lightweight. In addition, for interferometric far ultraviolet spectrometers, the requirements for precision positioning are more severe than for conventional spectrometers. To meet the challenge of lightweight optical instruments, a modular adjustment mechanism was developed to position two orthogonal axes of a universal three-axis gimbal support system with a positioning accuracy on the order of 10 arc seconds. The mechanism was designed as a self-contained assembly which can be removed after final alignment of a spacebound optical instrument to reduce its in-flight mass. To demonstrate the concept, a number of these assemblies were made and mounted on two of the positioning axes of a far ultraviolet spatial heterodyne interferometer. A shaft clamp was used on each positioning axis to retain the adjusted position. This paper describes the design of the mechanism and presents optical test results.

Tom, James L.↗

SLAC All Access: Atomic, Molecular and Optical Science Instrument

John Bozek, a staff scientist at SLAC's Linac Coherent Light Source (LCLS) X-ray laser who manages the LCLS Soft X-ray Department, takes us behind the scenes at the Atomic, Molecular and Optical Science (AMO) instrument, the first of six experimental stations now operating at LCLS. Samples used in AMO experiments include atoms, molecules, clusters, and nanoscale objects such as protein crystals or viruses. Science performed at AMO includes fundamental studies of light-matter interactions in the extreme X-ray intensity of the LCLS pules, time-resolved studies of increasingly charged states of atoms and molecules, X-ray diffraction imaging of nanocrystals, and single-shot imaging of a variety of objects.

36 MATERIALS SCIENCE↗

Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems

A technique was created to measure the pupil alignment of instruments in situ by measuring calibrated pupil alignment references (PARs) in instruments. The PAR can also be measured using an alignment telescope or an imaging system. PAR allows the verification of the science instrument (SI) pupil alignment at the integrated science instrument module (ISIM) level of assembly at ambient and cryogenic operating temperature. This will allow verification of the ISIM+SI alignment, and provide feedback to realign the SI if necessary.

Hagopian, John G.↗

Laser beam centering and pointing system

An optical instrument aligns an optical beam without the need for physical intervention of the instrument within the apparatus or platforms from which the trajectory of the beam to be ascertained. The alignment apparatus and method enable the desired function to be realized without the placement of physical apertures or sensors directly in the path of the beam through the system whose spatial position and slope is to be sought. An image plane provides the observer with a pair of well-defined images that are indicative of the beam centering and pointing alignment parameters. The optical alignment can be realized without the need for referencing to an external or fixed set of coordinates or fiducials. The instrument can therefore service situations where adverse environments would otherwise prohibit the use of such instruments, including regions of high radiation, high temperature, vacuum and/or cryogenic atmospheres.

42 ENGINEERING↗

Experimental Estimation of CLASP Spatial Resolution: Results of the Instrument's Optical Alignment

The Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) is a sounding-rocket experiment currently being built at the National Astronomical Observatory of Japan. This instrument aims to probe for the first time the magnetic field strength and orientation in the solar upper-chromosphere and lower-transition region. CLASP will measure the polarization of the Lyman-Alpha line (121.6nm) with an unprecedented accuracy, and derive the magnetic field information through the Hanle effect. Although polarization accuracy and spectral resolution are crucial for the Hanle effect detection, spatial resolution is also important to get reliable context image via the slit-jaw camera. As spatial resolution is directly related with the alignment of optics, it is also a good way of ensuring the alignment of the instrument to meet the scientific requirement. This poster will detail the experiments carried out to align CLASP's optics (telescope and spectrograph), as both part of the instrument were aligned separately. The telescope was aligned in double-pass mode, and a laser interferometer (He-Ne) was used to measure the telescope's wavefront error (WFE). The secondary mirror tilt and position were adjusted to remove comas and defocus aberrations from the WFE. Effect of gravity on the WFE measurement was estimated and the final WFE derived in zero-g condition for CLASP telescope will be presented. In addition, an estimation of the spot shape and size derived from the final WFE will also be shown. The spectrograph was aligned with a custom procedure: because Ly-light is absorbed by air, the spectrograph's off-axis parabolic mirrors were aligned in Visible Light (VL) using a custom-made VL grating instead of the flight Ly- grating. Results of the alignment in Visible Light will be shown and the spot shape recorded with CCDs at various position along the slit will be displayed. Results from both alignment experiment will be compared to the design requirement, and will be combined in order to estimate CLASP spatial resolution after its alignment in visible light.

spatial resolution↗

KC-135 aero-optical turbulent boundary layer/shear layer experiment revisited

The aero-optical effects associated with propagating a laser beam through both an aircraft turbulent boundary layer and artificially generated shear layers are examined. The data present comparisons from observed optical performance with those inferred from aerodynamic measurements of unsteady density and correlation lengths within the same random flow fields. Using optical instrumentation with tens of microsecond temporal resolution through a finite aperture, optical performance degradation was determined and contrasted with the infinite aperture time averaged aerodynamic measurement. In addition, the optical data were artificially clipped to compare to theoretical scaling calculations. Optical instrumentation consisted of a custom Q switched Nd:Yag double pulsed laser, and a holographic camera which recorded the random flow field in a double pass, double pulse mode. Aerodynamic parameters were measured using hot film anemometer probes and a five hole pressure probe. Each technique is described with its associated theoretical basis for comparison. The effects of finite aperture and spatial and temporal frequencies of the random flow are considered.

Craig, J.↗

Cryogenic Test Capability at Marshall Space Flight Center's X-ray Cryogenic Test Facility

Marshall Space Flight Center's X-ray & Cryogenic Test Facility (XRCF) has been performing sub-liquid nitrogen temperature testing since 1999. Optical wavefront measurement, thermal structural deformation, mechanism functional & calibration, and simple cryo-conditioning tests have been completed. Recent modifications have been made to the facility in support of the James Webb Space Telescope (JWST) program. The chamber's payload envelope and the facility s refrigeration capacity have both been increased. Modifications have also been made to the optical instrumentation area improving access for both the installation and operation of optical instrumentation outside the vacuum chamber. The facility's capabilities, configuration, and performance data will be presented.

Kegley, Jeffrey↗

NGST OTA Optical Metrology Instrumentation and Conceptual Approaches

An Integrated Product Team (IPT) was formed to develop a detailed concept for optical test methodology for testing of the NGST individual primary, secondary and tertiary mirrors and the full telescope system on the ground. Optical testing is a significant cost driver therefore the testing has to understood in detailed fashion early. A brief summary of the preliminary metrology test plan at the mirror component and telescope system level is presented.

Keski-Kuha, R.↗

Space telescope optical telescope assembly/scientific instruments. Phase B: -Preliminary design and program definition study; Volume 2A: Planetary camera report

Development of the F/48, F/96 Planetary Camera for the Large Space Telescope is discussed. Instrument characteristics, optical design, and CCD camera submodule thermal design are considered along with structural subsystem and thermal control subsystem. Weight, electrical subsystem, and support equipment requirements are also included.

Source record↗

Improved Cryogenic Optical Test Capability at Marshall Space Flight Center's X-ray Cryogenic Test Facility

Marshall Space Flight Center's X-ray & Cryogenic Test Facility (XRCF) has been performing optical wavefront testing and thermal structural deformation testing at subliquid nitrogen cryogenic temperatures since 1999. Recent modifications have been made to the facility in support of the James Webb Space Telescope (JWST) program. The test article envelope and the chamber's refrigeration capacity have both been increased. A new larger helium-cooled enclosure has been added to the existing enclosure increasing both the cross-sectional area and the length. This new enclosure is capable of supporting six JWST Primary Mirror Segment Assemblies. A second helium refrigeration system has been installed essentially doubling the cooling capacity available at the facility. Modifications have also been made to the optical instrumentation area. Improved access is now available for both the installation and operation of optical instrumentation outside the vacuum chamber. Chamber configuration, specifications, and performance data will be presented.

Kegley, Jeffrey↗

Remote Synchrotron Light Instrumentation Using Optical Fibers

By coupling the emitted synchrotron light into an optical fiber, it is possible to transmit the signal at substantial distances from the light port, without the need to use expensive beamlines. This would be especially beneficial in all those cases when the synchrotron is situated in areas not easily access because of their location, or due to high radiation levels. Furthermore, the fiber output can be easily switched, or even shared, between different diagnostic instruments. We present the latest results on the coupling and dispersion measurements performed at the Advanced Light Source in Berkeley. In several cases, coupling synchrotron light into optical fibers can substantially facilitate the use of beam diagnostic instrumentation that measures longitudinal beam properties by detecting synchrotron radiation. It has been discussed in with some detail, how fiberoptics can bring the light at relatively large distances from the accelerator, where a variety of devices can be used to measure beam properties and parameters. Light carried on a fiber can be easily switched between instruments so that each one of them has 100% of the photons available, rather than just a fraction, when simultaneous measurements are not indispensable. From a more general point of view, once synchrotron light is coupled into the fiber, the vast array of techniques and optoelectronic devices, developed by the telecommunication industry becomes available. In this paper we present the results of our experiments at the Advanced Light Source, where we tried to assess the challenges and limitations of the coupling process and determine what level of efficiency one can typically expect to achieve.

43 PARTICLE ACCELERATORS↗