Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical transmission systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Methane monitoring and detection apparatus and methods

A low cost, low power, passive optical methane monitoring system for fixed-position installation at oil and gas production well pads and gathering centers is disclosed. The optical methane monitoring system disclosed can be a scannable field of view Near Infrared (NIR) filter photometer to detect and quantify methane concentration in a two dimensional or a three dimensional grid above and around a facility. A randomized fiber optic bundle is disclosed that can be used to direct the total optical power from a collection lens to two or more isolated optical channels. Band pass filters isolate a desired wavelength range for transmission measurements for the two or more channels. Also disclosed is an absorption algorithm which accounts for variable background spectral intensity as well as correcting for water vapor and overall scattering effects to measure methane concentration for a given field of view.

Lievois, John↗

When do molecular polaritons behave like optical filters?

This review outlines several linear optical effects featured by molecular polaritons arising in the collective strong light–matter coupling regime. Under weak laser irradiation and when the single-molecule light–matter coupling can be neglected (often in the limit when the number of molecules per photon mode is large), we show that the excited-state molecular dynamics under collective strong coupling can be exactly replicated without the cavity using a shaped (or “filtered”) laser, whose field amplitude is enhanced by the cavity quality factor, shining on the bare molecules. As a consequence, the absorption within a cavity can be understood as the overlap between the polariton transmission and the bare molecular absorption, suggesting that polaritons act in part as optical filters. This framework demystifies and provides a straightforward explanation for a large class of experiments and theoretical models in molecular polaritonics, highlighting that the same effects can be achieved without the cavity with shaped laser pulses. With a few modifications, this simple conceptual picture can also be adapted to understand the incoherent nonlinear response of polaritonic systems. This review establishes a clear distinction between polaritonic phenomena that can be fully explained through classical linear optics and those that require a quantum electrodynamics approach. It also highlights the need to differentiate between effects that necessitate polaritons (i.e., hybrid light–matter states) and those that can occur in the weak coupling regime. Here, we further discuss that certain quantum optical effects like fluorescence can be partially described as optical filtering, whereas some others like cavity-induced Raman scattering go beyond this. Further exploration in these areas is needed to uncover novel polaritonic phenomena beyond optical filtering.

Schwennicke, Kai [University of California, San Di↗

Electromagnetic waves in an optical photonic lattice

Laser light propagation in a photonic lattice consisting of two parallel waveguide arrays is theoretically studied using the coupled mode method, with the interaction of each waveguide with the nearest neighbours and between the waveguides of the arrays being taken into account. Analytical expressions are obtained that make it possible to accurately predict the presence of localisation of light depending on the coupling constants. Particular solutions of a system of coupled waves are found, which describe strongly localised light propagating without transverse diffraction along the entire lattice at certain values of the coupling constants. The emergence of spatially limited transverse diffraction of light is predicted. (integral optics)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Conceptual design and performance predictions for 2D beam emission spectroscopy turbulence measurements at Wendelstein 7-X

A conceptual design for a 2D beam emission spectroscopy diagnostic system to measure ion gyro-scale plasma turbulence at Wendeslstein 7-X is described. The conceptual design identifies field-aligned viewing geometries and ports for cross-field turbulence measurements in the neutral beam volume. A 2D sightline grid covers the outer plasma region, and the grid configuration provides sufficient k-space coverage in radial and poloidal directions for ion temperature gradient and trapped-electron mode turbulence measurements. Emission intensity estimates, optical transmission losses, and detector noise levels indicate that the measurements will be sensitive to plasma density fluctuations as small as δn/n ≈ 0.5% with a bandwidth of 1 MHz. Implementation challenges include a small beam emission Doppler shift due to nearly radial heating beams and reduced optical throughput due to collection aperture limitations.

47 OTHER INSTRUMENTATION↗

Linear response of molecular polaritons

In this article, we show that the collective light–matter strong coupling regime where N molecular emitters couple to the photon mode of an optical cavity can be mapped to a quantum impurity model where the photon is the impurity that is coupled to a bath of anharmonic transitions. In the thermodynamic limit where N ≫ 1, we argue that the bath can be replaced with an effective harmonic bath, leading to a dramatic simplification of the problem into one of the coupled harmonic oscillators. We derive simple analytical expressions for linear optical spectra (transmission, reflection, and absorption) where the only molecular input required is the molecular linear susceptibility. This formalism is applied to a series of illustrative examples, showing the role of temperature, disorder, vibronic coupling, and optical saturation of the molecular ensemble, explaining that it is useful even when describing an important class of nonlinear optical experiments. For completeness, we provide Appendixes A–C that include a self-contained derivation of the relevant spectroscopic observables for arbitrary anharmonic systems (for both large and small N) within the rotating-wave approximation. While some of the presented results herein have already been reported in the literature, we provide a unified presentation of the results as well as new interpretations that connect powerful concepts in open quantum systems and linear response theory with molecular polaritonics.

Chemistry↗

Ab Initio Polariton Spectra of ZnTPP Molecules Collectively Coupled Inside an Optical Cavity

Exciton-polaritons are quasi-particles formed by the quantum mechanical hybridization of electronic and photonic excitations. Despite extensive investigations, a fundamental understanding of molecular polariton spectra and the polariton delocalization from an ab initio theoretical perspective remains elusive. We simulate experimentally measured linear transmission spectroscopy of many Zinc(II) tetraphenylporphyrin (ZnTPP) molecules collectively coupled to a cavity from first principles. Our theoretical approach incorporates many low-lying electronic excitations in ZnTPP molecules, as well as collective light-matter couplings between ZnTPP and the quantized radiation modes, both of which are shown to be the key to accurately recovering the experimental spectra. We further analyzed to what extent the polariton and dark states are delocalized over many molecules, for the first time, using fully ab initio descriptions of the molecules. We finally investigate the line width as a function of detuning, providing new theoretical insights into the experimentally observed motional narrowing behavior. Our work presents first-ofits- kind theoretical studies on molecular polariton spectra, offering a new perspective on molecular polariton formation in realistic ab initio molecular systems whose rich, many-state nature provides spectral features enabled by the high density of electronic states beyond simple quantum optics models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of the High Rigidity Spectrometer at FRIB

A High Rigidity Spectrometer (HRS) has been designed for experiments at the Facility for Rare-Isotope Beams (FRIB) at Michigan State University (MSU). The HRS will allow experiments to be performed with the most exotic neutron-rich isotopes at high beam energies (≳100 MeV/u). The HRS consists of an analysis beamline called the High-Transmission Beamline (HTBL) and the spectrometer proper called the Spectrometer Section. Here, the maximum magnetic rigidity of the HRS is 8 Tm, which corresponds to the rigidities at which rare-isotope beams are optimally produced at FRIB. The resolving power, angular acceptance, and momentum acceptance are set to match the anticipated scientific program. An ion-optical design developed for the HRS is described in detail, along with the specifications of the associated magnet and detector systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultra: Underwater Laser Telecommunications & Remote Access (Final Report)

High speed wireless communication has proven elusive in subsea environments due to the inherent bandwidth limitations of acoustics and range limitations of other transmission modalities. A truly connected subsea system necessitates a high-speed, resilient architecture that can enable the integration of new sensor technologies and edge analytics and allow closed-loop monitoring and control of subsea operations for integrity monitoring and optimization. Like terrestrial Internet of Things applications, the realization of this “digital subsea” vision requires the application of high speed, point-to-point wireless technologies to complement rather than replace “hard-wired” communications such as optical fiber or acoustic systems. This work addresses the development of ULTRA (Underwater LASER Telemetry and Remote Access), an ultra-long range underwater laser communications system for use in critical points of the subsea communications architecture to increase reliability, operational flexibility, and reduce communication system maintenance associated with physical subsea connections.

02 PETROLEUM↗

First Offline Results from the S3 Low-Energy Branch

We present the first results obtained from the S3 Low-Energy Branch, the gas cell setup at SPIRAL2-GANIL, which will be installed behind the S3 spectrometer for atomic and nuclear spectroscopy studies of exotic nuclei. The installation is currently being commissioned offline, with the aim to establish optimum conditions for the operation of the radio frequency quadrupole ion guides, mass separation and ion bunching, providing high-efficiency and low-energy spatial spread for the isotopes of interest. Transmission and mass-resolving power measurements are presented for the different components of the S3-LEB setup. In addition, a single-longitudinal-mode, injection-locked, pumped pulsed-titanium–sapphire laser system has been recently implemented and is used for the first proof-of-principle measurements in an offline laser laboratory. Laser spectroscopy measurements of erbium, which is the commissioning case of the S3 spectrometer, are presented using the 4f126s23H6→4f12(3H)6s6p optical transition.

Romans, Jekabs (ORCID:0000000197427745)↗

Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry

Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett’s advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. Here, this phenomenon is illustrated with both tobacco mosaic virus (0.6–2.7 MDa) and AAV9 (3.7–4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calcined Polyethyleneimine Coated Optical Fibers for Distributed pH Monitoring at High Pressures and Temperatures

In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Building off of earlier TiO2 based pH sensors and the known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. The sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1000 psi) and temperatures (80 °C). A calibration curve with strong differentiation between acidic and alkaline pH was developed for both transmission-based and distributed pH measurements, using fixed wavelength transmission and integrated linear amplitude of backscattered light for distributed measurements.

Shumski, Alexander↗

Laser-free GHz stroboscopic transmission electron microscope: Components, system integration, and practical considerations for pump–probe measurements

In this work a 300 keV transmission electron microscope was modified to produce broadband pulsed beams that can be, in principle, between 40 MHz and 12 GHz, corresponding to temporal resolution in the nanosecond to picosecond range without an excitation laser. The key enabling technology is a pair of phase-matched modulating and de-modulating traveling wave metallic comb striplines (pulsers). An initial temporal resolution of 30 ps was achieved with a strobe frequency of 6.0 GHz. The placement of the pulsers, mounted immediately below the gun, allows for preservation of all optical configurations, otherwise available to the unmodified instrument, and therefore makes such a post-modified instrument for dual-use, i.e., both pulsed-beam mode (i.e., stroboscopic time-resolved) and conventional continuous waveform mode. In this article, we describe the elements inserted into the beam path, challenges encountered during integration with an in-service microscope, and early results from an electric-field-driven pump–probe experiment. We conclude with ideas for making this class of instruments broadly applicable for examining cyclical and repeatable phenomena.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum statistical plasmonic metacrystals

Engineering materials that control quantum many-body dynamics remains challenging, as multiparticle interactions typically produce complex emergent behaviour that is difficult to predict. Here we introduce quantum statistical plasmonic metacrystals, structures in which the multiparticle dynamics mediated by optical near fields produce forbidden quantum statistical bands that enable selective transmission of different types of light. This functionality arises from a plasmonic structure composed of nanoantennas acting as meta-atoms. Multiphoton fields with statistics within the allowed bands propagate without distortion, whereas fields in forbidden bands are suppressed or driven towards the nearest accessible statistical state. We show that these bands are determined by the geometry and collective arrangement of the meta-atoms, providing a deterministic route to engineering quantum statistical transport. This platform establishes a room-temperature quantum material intrinsically sensitive to the quantum coherence of many-body photonic systems, enabling their robust manipulation and transport. Our results have implications for coherence-sensitive photonic materials for energy harvesting and scalable many-body quantum technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring Local Turbulence Along the Optical Path: Multi-Beam Optical Seeing Sensor

Deflection of light along the optical path is a major source of image degradation for ground-based telescopes. Methods have been developed to measure upper atmospheric seeing based on models of the turbulence in the atmosphere, but due to boundary conditions, transmission within telescope enclosures is more complex. The Multi-beam Optical Seeing Sensor (MOSS) directly measures the component of the image quality degradation from inhomogeneity of the index of refraction within the telescope dome. MOSS outputs four near-parallel beams of light that travel along the optical path and are imaged by the telescope’s detector, landing like starlight on the telescope’s focal plane. By using a strobed light source, we can ‘freeze’ the instantaneous index variations transverse to the optical path. This system captures both ‘dome’ and ‘mirror’ seeing. Through plotting the standard deviation of differential motion between pairs of beams, MOSS enables characterization of the length scale of turbulence within the dome. The temporal coherence of temperature gradients can be probed with different pulse lengths, and the spatial coherence by comparing pairs at different separations across the aperture of the telescope. Optical path turbulence measurements, alongside other telemetry metrics, will guide thermal and airflow management to optimize image quality. A MOSS prototype was installed in the 1.2[Formula: see text]m Auxiliary Telescope (AuxTel) at the Vera C. Rubin Observatory in Chile, and preliminary data constrain the optical path turbulence with a lower bound of 1.4 arcsec. The optical path turbulence varied throughout the night of observing.

Astronomical seeing↗

Signal Processing of Multiplexed Optical PWM Signals for Sensor Arrays in Nuclear Environments

Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.

Sweeney, Dan↗

High-Frequency 3D Photoacoustic Computed Tomography Using an Optical Microring Resonator

3D photoacoustic computed tomography (3D-PACT) has made great advances in volumetric imaging of biological tissues, with high spatial-temporal resolutions and large penetration depth. The development of 3D-PACT requires high-performance acoustic sensors with a small size, large detection bandwidth, and high sensitivity. In this work, we present a new high-frequency 3D-PACT system that uses a microring resonator (MRR) as the acoustic sensor. The MRR sensor has a size of 80 μ m in diameter and was fabricated using the nanoimprint lithography technology. Using the MRR sensor, we have developed a transmission-mode 3D-PACT system that has achieved a detection bandwidth of ~23 MHz, an imaging depth of ~8 mm, a lateral resolution of 114 μ m, and an axial resolution of 57 μ m. We have demonstrated the 3D PACT’s performance on in vitro phantoms, ex vivo mouse brain, and in vivo mouse ear and tadpole. The MRR-based 3D-PACT system can be a promising tool for structural, functional, and molecular imaging of biological tissues at depths.

47 OTHER INSTRUMENTATION↗

Precision-controlled ultrafast electron microscope platforms. A case study: Multiple-order coherent phonon dynamics in 1T-TaSe2 probed at 50 fs–10 fm scales

We report on the first detailed beam tests attesting the fundamental principle behind the development of high-current-efficiency ultrafast electron microscope systems where a radio frequency (RF) cavity is incorporated as a condenser lens in the beam delivery system. To allow for the experiment to be carried out with a sufficient resolution to probe the performance at the emittance floor, a new cascade loop RF controller system is developed to reduce the RF noise floor. Temporal resolution at 50 fs in full-width-at-half-maximum and detection sensitivity better than 1% are demonstrated on exfoliated 1T-TaSe2 system under a moderate repetition rate. To benchmark the performance, multi-terahertz edge-mode coherent phonon excitation is employed as the standard candle. The high temporal resolution and the significant visibility to very low dynamical contrast in diffraction signals via high-precision phase-space manipulation give strong support to the working principle for the new high-brightness femtosecond electron microscope systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗