Search NASA⌕ Search

SEARCH · Search NASA

Results for “parabolic reflectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The OMNIUM-G HTC-25 tracking concentrator

A point focusing, two axis tracking, high concentration ratio parabolic reflector is described. Field experience coupled with engineering improvements are shown to have manifested a design that is economic in the areas of manufacturing, packaging, delivering, installing, and commissioning the system into operation. The initial problems specifically with the OMNIUM-G model HTC-25 tracking concentrator are addressed.

Zelinger, S.↗

Design definition of a microwave power reception and conversion system for use on a high altitude powered platform

The design definition of a microwave power reception and conversion system for use on high altitude powered platform is presented. The study includes an initial design, construction and test effort on a thin film, printed circuit rectenna. A study of a low altitude demonstration of an airborne rectenna was made starting with the assumption that a fifty foot mechanically steerable parabolic reflector at the Wallops Flight Center would be retrofitted with a low microwave power source consisting of a five kilowatt commercially available magnetron and that a small blimp would be used to support the rectenna.

W. C. Brown↗

Radiometer for accurate (+ or - 1%) measurement of solar irradiance equal to 10,000 solar constants

The 10,000 solar constant radiometer was developed for the accurate (+ or - 1%) measurement of the irradiance produced in the image formed by a parabolic reflector or by a multiple mirror solar installation. This radiometer is water cooled, weighs about 1 kg, and is 5 cm (2 in.) in diameter by 10 cm (4 in.) long. A sting is provided for mounting the radiometer in the solar installation capable of measuring irradiances as high as 20,000 solar constants, the instrument is self calibrating. Its accuracy depends on the accurate determination of the cavity aperture, and absorptivity of the cavity, and accurate electrical measurements. The spectral response is flat over the entire spectrum from far UV to far IR. The radiometer responds to a measurement within 99.7% of the final value within 8 s. During a measurement of the 10,000 solar constant irradiance, the temperature rise of the water is about 20 C. The radiometer has perfect cosine response up to 60 deg off the radiometer axis.

Kendall, J. M., Sr.↗

Multiple beam offset antenna design processes

Both RF design steps and performance evaluation processes of multiple beam offset parabolic reflectors are described. Attempts are made to present the general methodology with a demonstration of the final results.

Source record↗

Parabolic Solar Collectors

Paper presents tutorial overview of point focusing parabolic reflectors for solar-energy collectors. Optical and thermal characteristics of collectors discussed in detail.

Truscello, V. C.↗

Wrap-rib antenna concept development overview

The wrap rib antenna design of a parabolic reflector large space antenna is discussed. Cost estimates, design/mission compatibility, deployment sequence, ground based tests, and fabrication are discussed.

Woods, A. A., Jr.↗

State and model error estimation for elliptic systems: Applications to large antenna static shape determination

This paper outlines the application of various estimation approaches to the problem of static shape determination for large antenna systems. The problem consists of estimating the shape of an antenna surface from measurements of its static deflection. The estimation schemes are based on any one of the modeling options of a single PDE for early insight and understanding, coarse-resolution multiple-PDE models for parametric studies and fine-resolution piecewise-continuum models for detailed design. For any one of these three models, estimator design can be developed using an infinite-dimensional approach, where the necessary finite-element truncation and approximation is conducted after the analytical design has taken place, or it can be based on a finite-dimensional approach, where the model is truncated before the estimation problem is formulated. One of the main objectives of the paper is to develop both approaches while simultaneously investigating their differences and similarities. Simulation results of an application of the finite-dimensional approach to a large parabolic reflector are presented.

Rodriguez, G.↗

LAMMR: A new generation satellite microwave radiometer - Its concepts and capabilities

Definition studies and baseline design are summarized for the proposed, and now discontinued, LAMMR. The instrument is an offset parabolic reflector with Cassegrain feeds. The three-meter aperture reflector, to be constructed using graphite-epoxy technology, rotates continuously at 0.833 rps. The scan drive subsystem includes momentum compensation for the rotating mass which includes the reflector, the support arm and Cassegrain subreflector, feed horns and radiometer. Two total power radiometers are recommended for each frequency, one each for horizontal and vertical polarizations. The selection plan, definition study specifications, LAMMR performance specifications, and predicted accuracies and resolutions after processing are shown.

Walton, W. T.↗

Cassegrainian concentrator solar array exploratory development module

A miniaturized Cassegrainian concentrator solar array concept is under development to reduce the cost of multi-kW spacecraft solar arrays. A primary parabolic reflector directs incoming solar energy to a secondary, centrally mounted inverted hyperbolic reflector and down onto a solar cell mounted on an Mo heat spreader on a 0.25 mm thick Al heat fin. Each unit is 12.7 mm thick, which makes the concentrator assembly roughly as thick as a conventional panel. The output is 100 W/sq and 20 W/kg, considering 20% efficient Si cells at 100 suns. A tertiary light catcher is mounted around the cell to ameliorate optic errors. The primary reflector is electroformed Ni with protective and reflective coatings. The cells have back surface reflectors and a SiO antireflective coating. An optical efficiency of 80% is projected, and GaAs cells are being considered in an attempt to raise cell efficiencies to over 30%.

Patterson, R. E.↗

Ten Thousand Solar Constants Radiometer

"Radiometer for Accurate (+ or - 1%) Measurement of Solar Irradiances Equal to 10,000 Solar Constants," gives additional information on radiometer described elsewhere. Self-calibrating, water-cooled, thermopile radiometer measures irradiance produced in solar image formed by parabolic reflector or by multiple-mirror solar installation.

Kendall, J. M., Sr.↗

Study of multi-kilowatt solar arrays for Earth orbit applications

A miniaturized Cassegrainian concentrator (MCC) solar array concept is being developed with the objective of significantly reducing the recurring cost of multikilowatt solar arrays. The desired cost reduction is obtained as a result of using very small high efficiency solar cells in conjuction with low cost optics. The MCC single element concept incident slar radiation is reflected rom a primary parabolic reflector to a secondary hyperbolic reflector and finally to a 4 millimeter diameter solar cell. A light catcher cone is used to improve off axis performance. The solar cell is mounted to a heat fin. An element is approximately 13 millimeters thick which permits efficient launch stowage of the concentrator system panels without complex optical component deployments or retractions. The MCC elements are packed in bays within graphite epoxy frames and are electrically connected into appropriate series-parallel circuits. A MCC sngle element with a 21 sq cm entrance aperture and a 20 efficient, 0.25 sq cm gallium arsenide solar cell has the same power output as 30 sq cm of 11-percent efficiency (at 68 C) silicon solar cells.

Patterson, R. E.↗

Design, performance investigation and delivery of a miniaturized Cassegrainian concentrator solar array

A miniaturized Cassegrainian concentrator (MCC) solar array concept is being developed with the objective of significantly reducing the recurring cost of multikilowatt solar arrays. The desired cost reduction is obtained as a result of using very small high efficiency solar cells in conjunction with low-cost optics. In the MCC single element concept and panel concept, incident solar radiation is reflected from a primary parabolic reflector to a secondary hyperbolic reflector and finally to a 4-millimetr diameter solar cell. A light catcher cone is used to improve off-axis performance. An element is approximately 13-millimeters thick which permits efficient launch stowage of the concentrator system panels without complex optical component deployments or retractions. The MCC elements are packed in bays within graphite epoxy frames and are electrically connected into appropriate series-parallel circuits. A MCC single element with a 21 sq cm entrance aperture and a 20 percent efficient, 0.25 sq cm gallium arsenide solar cell has the same power output as 30-sq cm of 11-percent efficiency (at 68 C) silicon solar cells. The MCC concept provides the potential for a significant reduction in array cost due to a 99 percent reduction in required cell area and a 30 percent reduction in array area relative to planar array of equivalent power.

Patterson, R. E.↗

Kalman-like estimation for static distributed systems Antenna shape from radiation measurements

This paper advances an approach to the determination of shape of static distributed systems. It also illustrates the application of the approach to the problems of surface diagnosis of large parabolic reflectors. The estimation methods developed combine in an optimal sense the information from an elliptic model of the structure and from measurements of the structural deflection and of the far-field pattern changes due to the structural deformation. The estimators have a predictor-corrector structure, quite similar to that of a Kalman filter. The system model is first used to obtain a predicted estimate. A correction term is then added to the prediction to obtain the final state estimate. The relative weighting between prediction and correction terms is determined by an estimator gain. As in a Kalman filter, the estimator gain can be expressed in terms of the state estimation error covariance.

Rodriguez, G.↗

Curved edge modification of compact range reflector

For many years, the compact range has successfully been used to design and evaluate many electromagnetic radiation and scattering systems. However, it has had limited use for large structures because of the large discrepancy between the reflector and target zone sizes. The limitation results from the large edge diffracted signal which emanates from the termination of the reflector. Previous attempts to solve this problem have involved using serrated edges to diffuse the diffracted field. While this reduces the edge diffracted field in the target zone, it is not eliminated. In addition, one has introduced many new corners which also diffract into the target zone. A curved edge modification is presented which reduces the edge diffraction by an order of magnitude or more and in the process does not create new mechanisms which perturb the plane wave in the target zone. Using this curved modification, one is able to design a compact range reflector whose target zone cross section approaches the size of the reflector parabolic surface. This makes the compact range ideal for scale model measurements since larger targets (antennas) can be measured. It also makes it more practical to consider systems which can measure full scale vehicles.

Burnside, Walter D.↗

High throughput X-ray optics - An overview

Techniques for the production of high-throughput modular arrays of telescopes with net collecting areas exceeding 10 to the 5th sq cm and 20-arsec angular resolution are discussed. Techniques considered include the automated figuring of flats as parabolic reflectors, the replication of cylindrical shells, the alignment of thin lacquer-coated conical foils, electroforming, and the use of large diamond turning machines. High-throughput programs are described, and it is noted that future missions will emphasize high resolution spectroscopy.

Gorenstein, Paul↗

Concentration of off-axis radiation by solar concentrators for space power

Off-axis radiation is radiation from any direction not parallel to the axis of the solar concentrator. It will be reflected to regions other than the focus of the parabolic concentrator and possibly concentrated there. Four types of off-axis radiation are discussed. These are: (1) small off-axis angles during walk-off; (2) large off-axis angles; (3) an extended off-axis source such as Earth albedo; and (4) miscellaneous off-axis sources including radio frequency sources and local point sources. A previous analytical study used a computer code named PIXEL to predict concentration of off-axis radiation and a previous experimental study used an 11-m diameter multifaceted dish concentrator to validate the PIXEL analysis. The PIXEL code was limited in that it represented concentration by an ideal parabolic reflector of light from a point source. Another code named OFFSET has been developed to represent the solar concentrator being developed for Space Station Freedom. It is a detailed, ray tracing model which represents 50 ray originating points on the Sun and reflections from 10 points on each of the 456 concentrator facets. Results of this code are generally similar to the PIXEL results although there are small differences due to the more detailed representations of the Sun and concentrator that were used in the OFFSET code.

Jefferies, Kent S.↗

A planar near-field scanning technique for bistatic radar cross section measurements

A progress report on the development of a bistatic radar cross section (RCS) measurement range is presented. A technique using one parabolic reflector and a planar scanning probe antenna is analyzed. The field pattern in the test zone is computed using a spatial array of signal sources. It achieved an illumination pattern with 1 dB amplitude and 15 degree phase ripple over the target zone. The required scan plane size is found to be proportional to the size of the desired test target. Scan plane probe sample spacing can be increased beyond the Nyquist lambda/2 limit permitting constant probe sample spacing over a range of frequencies.

Tuhela-Reuning, S.↗