Search NASA⌕ Search

SEARCH · Search NASA

Results for “peak load management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE↗

The first field application of a low-cost MPC for grid-interactive K-12 schools: Lessons-learned and savings assessment

K-12 schools are the largest energy consumers in the public sector, with their HVAC energy consumption representing the largest portion of their total energy use. While transitioning these schools to grid-interactive HVAC system operation through advanced controls offers significant financial and environmental benefits, and model predictive control (MPC) has been identified as a promising solution to achieve that, very few MPCs are affordable and have been deployed in K-12 schools. This situation raises concerns about the unclear real-world benefits of MPC technology among facility managers and industries. To address this gap, this paper presents a low-cost MPC solution that requires minimal control infrastructure costs and a unique field demonstration at a K-12 school, conducted for both cooling and heating seasons. This work adopted a previously developed MPC and extended it for use in the school application. The MPC aims to coordinate multiple packaged units to eliminate unnecessary peaks and shift cooling or heating loads in response to grid signals based on load conditions, while maintaining thermostat temperatures within school-defined bounds. Throughout the field tests, the MPC achieved a 24% reduction in peak demand during the cooling season and shifted cooling or heating loads by up to 16% in response to the school's utility tariff, considering load conditions, while also allowing end-users to override thermostat setpoints. Further, the paper also discusses the limitations of this study and future research directions for better performance of the MPC at K-12 schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Early Research in Load-Following Management for HPC-Nuclear Integration

With the rising demand for high performance computing (HPC) and artificial intelligence (AI) systems, maintaining a stable and efficient power supply is increasingly critical. The HPC team at Idaho National Laboratory is spearheading efforts to seamlessly integrate HPC systems with nuclear reactors. This lightning talk explores one early strategy for managing power fluctuations using software-defined controls. To effectively harness nuclear reactors for power generation, control mechanisms are essential to address the slow load-following capabilities of reactors, which are typically around 5% per minute. While this rate is sufficient for many uses, large HPC systems can experience rapid power consumption changes by tens of megawatts when jobs start or stop running. A reactor could overproduce power and match the peak power rating for the HPC system, however when the system is not running a job or a job unexpectedly stops, the load-following of the system would be affected leading to power being wasted and the likelihood of power transient occurrences increases. Controlling the increase or decrease of power consumption on these systems at the same rate as the load-following of reactors is one piece of the puzzle to properly utilizing nuclear reactors as a power source for HPC systems.

97 - MATHEMATICS AND COMPUTING↗

Best Practices for Shielding Analyses of Activated Metals and Spent Resins from Reactor Operation

This report investigated best practices for performing shielding evaluations of Type B waste packages, as defined in 10 CFR Part 71 regulations on packaging and transportation of radioactive material, or packages for which the contents are not defined before loading and may include a broad range of nuclides, geometries, and non-fuel materials. The following non-fuel waste streams were analyzed: Activated metals from decommissioned commercial power reactors, including Type 304 stainless steel, reactor vessel steel, and Inconel, Control blades from boiling water reactors, Neutron-activated corrosion products on surfaces of activated metals, and Spent resins from power plant operations. Measured elemental compositions, including major constituents and impurities, for steel and Inconel samples from commercial power reactors were used in activation calculations to determine radionuclide inventories in activated metals. For a simplified cask model, 60 Co contribution to the total external package dose rate at 30 days after shutdown varied from approximately 60% to 95%, depending on the activated metal, initial cobalt impurity concentration in the metal, and the thickness of the overpack gamma shield. Its maximum contribution to the total external package dose rate of approximately 100% was reached within the time interval of 2 to 5 years after shutdown and was maintained for up to 45 to 60 years after shutdown, depending on material, initial cobalt impurity concentration, and shield thickness. Thereafter, the 60 Co contribution to external package dose rate decreased with increasing decay time. Cobalt-60 is primarily produced by neutron reactions with the cobalt impurity in steel and Inconel. Other important radionuclides in activated metals contributing to package external dose rate are radionuclides with relatively short decay times, including 51 Cr, 59 Fe, 58 Co, and 54 Mn. These radionuclides may be represented as an equivalent 60 Co activity/source because 60 Co gamma ray emissions are bounding in terms of source strength and energy to other important radionuclides identified in the analyzed activated metals. Approaches for modeling the neutron-activated corrosion products that may be attached to activated reactor components were analyzed in this report. It was demonstrated that a surface source is more conservative than a uniform volumetric source for the treatment of neutron-activated corrosion products with respect to external package dose rates. An analysis of the maximum radionuclide loadings reported on spent resins identified the radionuclides 137 Cs, 60 Co, 134 Cs, 65 Zn, and 58 Co as the primary contributors to external package dose rate. For a resin cooled for 3.08 years, the external package dose rate was entirely produced by the reported 137 Cs and 60 Co inventory. The neutron sources from actinides found on spent resins or activated metals produced negligible dose rates and may be ignored in dose rate analyses. Effects of idealized waste material, source geometry, and spatial material/source distributions on external package dose rates were determined based on dose rate results for a simplified cask model under normal conditions of transport. Type 304 stainless steel, zirconium, and aluminum with adjusted mass densities based on a maximum content weight were analyzed for material modeling effects on external package dose rate. These materials produced identical external package dose rates within the statistical uncertainties of the dose rate estimates. Among four different source geometry configurations with homogeneous material of different mass densities, uniform volumetric source distribution, and the same source strength, the geometry configuration with lowest mass density (i.e., minimum self-shielding effect among the four cases) was most conservative. Spatial source distributions that better represent localized peak 60 Co activity values were more conservative than a uniform volumetric source distribution, assuming the same weight and total source strength per package. The increase in external dose rate caused by localized source peaks can be as much as the ratio between source peak activity density to average activity density, depending on the location of the activated metal with peak activity density. Therefore, the shielding analysis may be simplified if localized peak activities and the average activity per package can be measured/determined and documented at the time of cask loading. For simplicity, external package dose rates may be determined based on average source activity and a uniform volumetric source distribution. The dose rate results from that calculation model multiplied by the ratio of peak activity density to average activity density will produce maximum dose rate values for conservative estimates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

An 802pW 93% Peak Efficiency Buck Converter with 5.5×10 6 Dynamic Range Featuring Fast DVFS and Asynchronous Load-Transient Control

Here this paper presents a buck converter with sub-nW quiescent power, high efficiency, and a wide dynamic range for ultra-low-power (ULP) IoT SoCs. To optimize the SoC power consumption, the buck converter supports fast dynamic voltage and frequency scaling (DVFS) and enables fast load-transient response (FLTR) through asynchronous control. In addition, the buck converter is fully self-contained with all features integrated on chip including a proposed adaptive deadtime controller. Fabricated in 65nm CMOS, measurement results show the buck converter has an 802pW quiescent power at 1.5V input voltage and a 93% peak efficiency. The measured dynamic range is from 0.5nW to 2.75mW, which is over 6 orders of magnitude. The measured voltage droop is 54mV for a 45nA-to-1mA load current step thanks to the asynchronous load-transient detector. The buck converter achieves the highest efficiency and widest dynamic range among all the state-of-the-art sub-nW switching voltage regulators, which makes it well suited for power management in ULP SoCs.

42 ENGINEERING↗

Smart and Efficient Building Envelopes: Thermal Switches and Thermal Storage for Energy Savings and Load Flexibility

The building envelope has traditionally been seen as a static component. Much of the past thermal advancements in building envelopes has consisted of developing higher R/inch insulation. While a suitable approach for static situations, it does not consider the dynamic nature of the ambient environment or the varying needs of the electrical grid. This paper will examine three possible ways that building envelopes can be actively managed: 1. thermal switches, 2. thermal storage, and 3. the coupling of the two. Spurring innovation to make building envelopes smarter will help reduce building energy consumption and peak energy usage and contribute to flexibility in energy demand in the future.

Mumme, Sven↗

Industrial battery operation and utilization in the presence of electrical load uncertainty using Bayesian decision theory

Behind the meter battery storage is becoming increasing popular in all sectors, though enthusiasm has recently lagged in the industrial sector. Even though there may be many factors contributing to this including lack of innovation, prohibitive costs, and undesirable rate structures, a difficulty arises in accounting for uncertainty of electrical load in industrial facilities while still attempting to utilize battery storage as much as possible all while trying to achieve fiscal profitability. Here this study utilizes Gaussian process regression and Bayesian decision theory to organize load data and quantify electrical load uncertainty to properly and effectively discharge industrial battery storage. The study employs a simulation model to set battery load setpoints for the span of the utility billing period according to the degree of risk aversion. This combination of economic analysis according to utility billing period and utilization of degree of risk aversion to make decisions on the uncertainty of the data has not before been applied to battery storage. The method resulted in an annual average reduction of peak demand by 3.8 % at the lowest amount of savings and lowest risk aversion. The highest risk aversion resulted in an annual average reduction of peak demand of 7.5 %. The maximum reduction of peak load in any month was 13.8 % in the month of December with a relatively high risk aversion. With a the highest amount risk aversion tested, the model reduced demand ten of the twelve months of the year.

25 ENERGY STORAGE↗

Liquid metal walls

Here, the plasma performance of fusion devices depends strongly on the chosen wall materials. Solid plasma-facing components (PFCs) are predominantly used in present devices, and are the most investigated candidates for fusion designs. High-Z materials such as tungsten (W) are the leading solid PFC material candidates. To date, a material choice that scales to steady-state reactor conditions has not been identified. Moreover, if plasma transient events such as edge-localized modes and disruptions cannot be altogether avoided or sufficiently mitigated, the projected peak heat and particle loads far exceed the power exhaust capabilities of solids. Liquid metal (LM) PFCs represent an intrinsic self-healing boundary that are both resilient to surface damage from transients, and that could handle high steady-state heat and particle fluxes. Flowing LM PFCs can be designed to remove “slag,” the buildup of material erosion due to plasma-material interactions, including charge exchange sputtering in the main chamber. Further, LM offer the prospect to manage hydrogenic species otherwise retained in the PFCs, which is important from a safety and inventory standpoint. The two most promising LMs are lithium (Li) and tin (Sn), although Sn–Li eutectics may be considered. While Sn offers a higher temperature window with low vapor pressure and low hydrogen retention, Li offers the prospect of enhanced energy confinement and higher acceptable core contamination limits, and this section focuses on Li PFCs. An LM PFC development research program developed LM PFC concepts for a nuclear fusion device via engineering design calculations, single-effect experiments, and staged prototypical experiments. A self-consistent design window was identified with liquid Li flow speeds ~5–10 m/s; plasma contamination was negligible for predicted Li evolution rates. While these preconceptual designs hold promise, there is substantial R&D needed to advance the technical readiness levels of LM PFCs for application to fusion power plants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Buildings Sector Scenarios: Demand-side data to support energy system planning in the United States

The US energy system is in a period of high uncertainty about load growth, its implications for the energy generation mix, and downstream impacts on customer energy costs. In this context, there is a need for comprehensive, credible, and readily-customized projections of energy demand to ensure that planning decisions account for end-use management opportunities to improve system reliability and affordability. Here we introduce the Buildings Sector Scenarios (BSS) dataset, which includes a benchmark suite of such projections for the buildings sector — a key source of energy consumption, peak electricity demand, and consumer energy expenditures. The dataset contains projections through 2050 covering the contiguous United States (CONUS) resolved down to the county, hourly level by sector and end use for electricity demand and to the state, annual level by sector and end use for non-electric fuels. We summarize the BSS analysis workflow and the tools and datasets that support it, document key BSS scenario inputs and modeling assumptions, and outline BSS scenario outputs. We assess the technical quality of the dataset against historical surveys and projected estimates of buildings sector demand. Finally, we provide guidance on how stakeholders can access, use, and reproduce the dataset, and/or create new scenarios to explore their own analysis questions.

Langevin, Jared↗

Managing Power Systems-Induced Wildfire Risks Using Optimal Scheduled Shutoffs: Preprint

The growing demands for electricity and the increase in extreme weather conditions are putting unprecedented pressure on our electrical grids. Oftentimes, this pressure leads to electrical components failures which might ignite wildfires. This work develops a novel model to balance the reliability of power networks operations and risks of wildfires ignition by optimizing the operational schedule of power transmission networks considering time-varying risk measures that consider exogenous and operational factors. Energy storage systems are considered to deliver power during peak wildfire hours and enable temporal load shifting. The problem is formulated as a mixed-integer linear program that maximizes a weighted sum of the served power demand and the reduction in grid-induced wildfires risk. The results demonstrate the ability of the model to reduce wildfires risks significantly without considerable load shedding.

energy scheduling↗

Energy flexibility of residential buildings: A systematic review of characterization and quantification methods and applications

With building electric demand becoming increasingly dynamic, and a growing percentage of intermittent renewable power generation from solar photovoltaics and wind turbines, the power grid is facing increasing challenge to manage the real time balance between the supply and demand. With advancements in smart sensing and metering, smart appliances, electric vehicles, and energy storage technologies, demand side management of residential buildings can help the grid to improve stability by optimizing flexible loads. This paper reviews recent studies on residential building demand side management, with a focus on characterization and quantification of energy flexibility covering various types of flexible loads, metrics, methods, and applications. The reviewed studies showed four levels of applications: building level (45%), district or community level (29%), system level (19%), and building sector level (7%). Shifting loads is the dominant flexibility type in 60% of applications, followed by shedding (19%), generation (16%), and modulating (6%). Depending on the technology and application scope, flexible operations have a wide range of performance, with peak power reductions of 1%~65%, energy savings up to 60%, operational cost reduction of 1%~48%, and greenhouse gas emission reductions of up to29%. More than half (51%) of the studies employed control strategies to achieve flexibility; among those 72% used optimal controls, while 28% used rule-based controls. About 58% of the studies used mathematical formulation to quantify energy flexibility. Most studies were based on simulation, while less than 15% of the studies had measurements from experiments or field tests. The review reveals research opportunities to address significant gaps in the existing literature: (1) establishing a common definition and performance metrics for energy flexibility of buildings that are technology and application agnostic, (2) developing an ontology to standardize representation of flexibility resources for interoperability, (3) integrating occupant impacts into the quantification and optimization of energy flexibility, and (4) developing requirements and credits of energy flexibility in building energy codes and standards. Findings from the review can inform future research and development of energy flexible buildings which are essential to a reliable and resilient power grid.

Li, H↗

Scaled Implementation of Smart Charge Management for Electric Vehicles

Smart charge management (SCM) has become a critical strategy for mitigating potential grid impacts and reducing electricity costs for all customers. This study will evaluate the economics of implementing light-duty EV SCM at scale across the United States. This work will enhance distribution system analysis by estimating SCM implementation costs, exploring viable business cases, and developing a framework for national-level applications. The primary methodology involves leveraging detailed grid modeling from a specific service territory and using spatial extrapolation techniques to generalize findings to other regions. The analysis will develop key metrics to quantify the costs and benefits of SCM, including implementation costs relative to strategy and scale, the cost of distribution system upgrades with and without SCM, and the percentage of peak-load reduction. The objective is to produce a comprehensive report and a parameterized framework that enables utilities to self-assess the value of SCM in their own service territories. This will support the development of cost-effective charging strategies, accelerate the energization of new EV chargers, and facilitate the seamless integration of EVs into the nation's power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Path to 100 Percent Renewable Energy: Grid-Forming Inverters will Give Us the Grid We Need Now

This is a more urgent problem than it might sound. The westernmost Hawaiian island of significant size, Kauai is home to around 70,000 residents and 30,000 tourists at any given time. Renewable energy accounts for 70 percent of the energy produced in a typical year - a proportion that's among the highest in the world and that can be hard to sustain for such a small and isolated grid. During the day, the local system operator, the Kauai Island Utility Cooperative, sometimes reaches levels of 90 percent from solar alone. But on 2 April, the 26-MW generator was running near its peak output, to compensate for the drop in solar output as the sun set. At the moment when it failed, that single generator had been supplying 60 percent of the load for the entire island, with the rest being met by a mix of smaller generators and several utility-scale solar-and-battery systems.

battery management systems↗

Model predictive control for demand flexibility: Real-world operation of a commercial building with photovoltaic and battery systems

Hundreds of studies have investigated Model Predictive Control (MPC) for the optimal operation of building energy systems in the past two decades. However, MPC field tests are still uncommon, especially for small- and medium-sized commercial buildings and for buildings integrated with onsite renewables. This paper describes the implementation and the long-term performance evaluation of an MPC controller in a small commercial building equipped with behind-the-meter photovoltaics and electrochemical batteries. MPC controls space conditioning, commercial refrigeration, and the battery system. We tested two types of demand flexibility applications in the field: electricity bill minimization under time-of-use tariffs and responses to grid flexibility events. Results show that the proposed controller achieves 12% of annual electricity cost savings and 34% peak demand reduction against the baseline, while respecting thermal comfort and food safety. The field tests also demonstrate the ability of the MPC controller to provide a multitude of grid services including real-time pricing, demand limiting, load shedding, load shifting, and load tracking, using the same optimization framework.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Understanding the Shift of Drivers of Soil Erosion and Sedimentation Based on Regional Process-Based Modeling in the Mississippi River Basin During the Past Century

Soil erosion and sedimentation problems remain a major water quality concern for making watershed management policies in the Mississippi River Basin (MRB). It is unclear whether the observed decreasing trend of stream suspended sediment loading to the mouth of the MRB over the last eight decades truly reflects a decline in upland soil erosion in this large basin. Here, for this work, we improved a distributed regional land surface model, the Dynamic Land Ecosystem Model, to evaluate how climate and land use changes have impacted soil erosion and sediment yield over the entire MRB during the past century. Model results indicate that total sediment yield significantly increased during 1980–2018, despite no significant increase in annual precipitation and runoff. The increased soil erosion and sediment yield are mainly driven by intensified extreme precipitation (EP). Spatially, we found notable intensified EP events in the cropland-dominated Midwest region, resulting in a substantial increase in soil erosion and sediment yield. Land use change played a critical role in determining sediment yield from the 1910s to the 1930s, thereafter, climate variability increasingly became the dominant driver of soil erosion, which peaked in the 2010s. This study highlights the increasing influences of extreme climate in affecting soil erosion and sedimentation, thus, water quality. Therefore, existing forest and cropland Best Management Practices should be revisited to confront the impacts of climate change on water quality in the MRB.

54 ENVIRONMENTAL SCIENCES↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Transactive Control of Flexible Building Loads Under Distribution LMP

With grid modernization efforts, future distribution networks, which consist of various distributed generators and flexible loads, will be more flexible and active. All new network components of distributed energy resources (DERs) drive and enable the transition towards a market-based distribution net-work that seeks the optimal allocation of all DERs. To address challenges associated with DERs, one promising solution is to utilize demand-side flexibility of building loads facilitated by demand response (DR) programs and provide ancillary grid services through distribution-level markets. Under this new paradigm, this paper proposes an efficient DR management strategy incorporating emerging price signals of distribution markets, i.e., distribution locational marginal price (DLMP), based on a hierarchical transactive control approach. The proposed approach establishes a two-layer decision-making framework; the upper layer formulates a bilevel model to obtain an optimal demand response (ODR) under DLMP, and the lower layer employs model-free control to dispatch the (aggregated) ODR to individual end users. Numerical case studies using a modified IEEE 33 test network are performed to verify the effectiveness of the proposed approach; load shifting and peak shaving for the distribution system operator and payments’ reduction for end users while maintaining their comfort.

Park, Byungkwon↗