Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

118 records · Page 7

Comparative Analysis of Heat Exchangers for High Temperature High Pressure Helium Component Testing

Helium gas loops have been designed and built to gain a better understanding of the gas thermohydraulic phenomena that take place in a helium system. Some of these loops are used for validation and testing of components for high temperature gas-cooled reactors (HTGRs). However, most of them operate at lower pressure and temperature than an HTGR. While these loops can provide valuable information about gas-cooled reactor components, the operating envelope of the experiment is constrained by the maximum operating conditions of the helium loop. In response to the lack of an experimental facility that can provide the infrastructure needed to validate and test components at nominal pressures and temperatures of HTGRS, the HElium Component Testing Out-of-pile Research (HECTOR) facility was designed at Idaho National Laboratory with the assistance of University of Idaho and Walsh Engineering. With the capability to test at temperatures up to 800°C and pressures of 8MPa, HECTOR serves as a critical tool for the advancement of HTGR technology. The facility's primary role is to provide a controlled, high-fidelity environment for the assessment of component resilience and efficiency under nominal HTGR conditions. In the quest to enhance the efficiency and performance of HECTOR, a comparative analysis of three distinct types of heat exchangers—shell and tube, offset strip fin, and printed-circuit—was conducted, focusing primarily on two critical metrics: the required surface area and pressure drop characteristics. The shell and tube heat exchanger, renowned for its robust design and widespread industrial application, was evaluated against the offset strip fin and the cuttingedge printed-circuit heat exchangers, both of which are lauded for their compactness and thermal effectiveness. This comparative study aims to provide detailed insights into the thermal management capabilities of each heat exchanger type under the conditions inherent to HECTOR, thereby facilitating an informed selection for systems demanding high operational integrity and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

Orthogonal chemical genomics approaches reveal genomic targets for increasing anaerobic chemical tolerance in Zymomonas mobilis

Genetically engineered microbes have the potential to increase efficiency in the bioeconomy by overcoming growth-limiting production stress. Screens of gene perturbation libraries against production stressors can identify high-value engineering targets, but follow-up experiments needed to guard against false positives are slow and resource-intensive. In principle, the use of orthogonal gene perturbation approaches could increase recovery of true positives over false positives because the strengths of one technique compensate for the weaknesses of the other, but, in practice, two parallel screens are rarely performed at the genome scale. Here, we screen genome-scale CRISPRi (CRISPR interference) knockdown and transposon insertion libraries of the bioenergy-relevant Alphaproteobacterium, Zymomonas mobilis, against growth inhibitors commonly found in deconstructed plant material. Integrating data from the two gene perturbation techniques, we established an approach for defining engineering targets with high specificity. This allowed us to identify all known genes in the cytochrome bc1 and cytochrome c synthesis pathway as potential targets for engineering resistance to phenolic acids under anaerobic conditions, a subset of which we validated using precise gene deletions. Strikingly, this finding is specific to the cytochrome bc1 and cytochrome c pathway and does not extend to other branches of the electron transport chain. We further show that exposure of Z. mobilis to ferulic acid causes substantial remodeling of the cell envelope proteome, as well as the downregulation of TonB-dependent transporters. Our work provides a generalizable strategy for identifying high-value engineering targets from gene perturbation screens that is broadly applicable.

CRISPRi↗

Role of pore dilation in molecular transport through the nuclear pore complex: Insights from polymer scaling theory

The nuclear pore complex (NPC), a channel within the nuclear envelope filled with intrinsically disordered proteins, regulates the transport of macromolecules between the nucleus and the cytoplasm. Recent studies have highlighted the NPC’s ability to adjust its diameter in response to the membrane tension, underscoring the importance of exploring how variations in pore size influence molecular transport through the NPC. In this study, we investigated the relationship between pore size and transport rate and proposed a mathematical model describing this connection. We began by theoretically analyzing how the pore size scales with the characteristic dimensions of the mesh-like structure within the pore. By introducing key assumptions about how the meshwork structure influences molecular diffusion, we derived a mathematical expression for the transport rate based on the size of the pore and the transported molecules. To validate our model, we conducted Brownian dynamics simulations using a coarse-grained representation of the NPC. These simulations, performed across a range of pore sizes, demonstrated strong agreement with our model’s predictions, confirming its accuracy and applicability. Our model is specifically tailored for small-to-medium-sized molecules, approximately 5 nanometers in size, making it relevant to a wide range of transcription factors and signaling molecules. It also extends to molecules with weak and transient interactions with FG-Nups, such as importin-β. By presenting this model formula, our study offers a quantitative framework for analyzing the effects of pore dilation on nucleocytoplasmic transport.

Biochemistry & Molecular Biology↗

From models to reality: a systematic review on simulated and measured residential heat pump energy savings

High-performance HVAC solutions are central to residential energy management. A substantial share of these are electric, reversible-cycle systems, with heat pumps representing the largest portion of current and near-term adoption. This review synthesizes peer-reviewed and grey literature on residential space heating and cooling heat pumps. The academic literature is dominated by modeling (73.8%), with limited field measurement (13.1%). Grey literature from United States serve as a supplemental resource providing measured savings. Conversions from electric-resistance heating consistently show the largest site energy reductions, while oil/propane baselines yield moderate savings, and gas baseline scenario often deliver small and region-dependent savings. This study cross-checks the grey literature measured data with simulation data filtered from the ResStock dataset. The comparison indicates a discrepancy between simulations and measured data: simulated site EUIs are typically lower than measured EUIs, but percentage energy savings fall in similar ranges, implying simulations capture directional effects while underestimating energy use. Factors associated with variability and model–measurement differences include system characterization and control representation (e.g., backup heat engagement, thermostat/setpoint strategies, commissioning/installation quality), occupant behavior, weather normalization, metering scope, and envelope characterization. This paper also outlines the proposed methodology for comparing simulation and measured data for heat pumps. It emphasizes the metrics used for comparison and units harmonization, building characteristics matching, and compact metadata are needed for simulations to match measured data. The proposed methodology is expected to improve the credibility of simulated savings as measured evidence grows.

Yu, Lili↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

Thermal Performance of Spandrel Assemblies in Glazed Wall Systems: Laboratory Test Design – Challenges and Test Results

Accurate thermal performance calculation procedures for opaque spandrel areas in curtain wall and window wall systems are essential for rating systems when comparing spandrel systems. However, there is a lack of consensus in thermal modeling needed for accurately characterizing heat transfer through spandrel assemblies due to the complex arrangement of materials and structural components. Several studies indicate that conventional 2D thermal simulations may overestimate R-values by 30% compared to physical testing and 3D simulations. Detailed simulations and well-curated laboratory test data are necessary to build confidence in simulation models, which will later be used to develop correlations to improve widely used conventional 2D thermal simulations. This study aims to experimentally test heat transfer through various spandrel assemblies to validate 3D simulation models. Also, the challenges of conducting a thorough testing design along with the solutions would be documented. The team developed a design for testing spandrel assemblies, making appropriate modifications to the existing heat, air, and moisture (HAM) chamber to accommodate the testing needs. Two moveable baffles were designed and fabricated to guide airflow direction parallel to the test article surface. The data acquisition capabilities in the chamber were upgraded to add more than two hundred sensors to the climate and indoor side of the chamber. The goal is to provide a quality dataset for validating complex 3D modeling simulations, which will be used to develop improved thermal simulation techniques that more accurately represent the thermal behavior of spandrel assemblies and their integration within the building envelope. This paper will summarize the results for the boundary conditions of the testing and the temperature variation across different locations of the spandrel assemblies.

Kunwar, Niraj [ORNL] (ORCID:0000000263457652)↗

Hydrodynamical Simulations of Proton Ingestion Flashes in Type I X-Ray Bursts

We perform the first multidimensional fluid simulations of thermonuclear helium ignition underneath a hydrogen-rich shell. This situation is relevant to Type I X-ray bursts on neutron stars that accrete from a hydrogen-rich companion. Using the low-Mach number fluid code MAESTROeX, we investigate the growth of the convection zone due to nuclear burning, and the evolution of the chemical abundances in the atmosphere of the star. We also examine the convective boundary mixing processes that cause the evolution to differ significantly from previous one-dimensional simulations that rely on mixing-length theory. We find that the convection zone grows outward as penetrating fluid elements cool the overlying radiative layer, rather than directly from the increasing entropy of the convection zone itself. Simultaneously, these flows efficiently mix composition, carrying carbon out of and protons into the convection zone even before contact with the hydrogen shell. We discuss the implications of these effects for future modeling of these events and observations.

astrophysical fluid dynamics↗

Geometrical optics without singularities: using the ray time as the coordinate space

Geometrical optics (GO) is widely used for reduced modelling of waves in plasmas, but it fails near reflection points, where it predicts a spurious singularity of the wave amplitude. We show how to avoid this singularity by adopting a different representation of the wave equation. Instead of the physical coordinate 𝑥 and the wavevector 𝑘, we use the ray time 𝜏 as the new canonical coordinate and the ray energy ℎ as the associated canonical momentum. To derive the envelope equation in the 𝜏-representation, we construct the Weyl symbol calculus on the (𝜏,ℎ) space and show that the corresponding Weyl symbols are related to their (𝑥,𝑘) counterparts by the Airy transform. This allows us to express the coefficients in the envelope equation through the known properties of the original dispersion operator. When necessary, solutions of this equation can be mapped to the 𝑥-space using a generalised metaplectic transform. However, the field per se might not even be needed in practice. Instead, knowing the corresponding Wigner function usually suffices for linear and quasilinear calculations. As a Weyl symbol itself, the Wigner function can be mapped analytically, using the aforementioned Airy transform. We show that the standard Airy patterns that form in regions where conventional GO fails are successfully reproduced within metaplectic GO (MGO) simply by remapping the field from the 𝜏-space to the 𝑥-space. An extension to mode-converting waves is also presented. This formulation, which we call generalised MGO, can be particularly useful, for example, for reduced modelling of the O–X conversion in inhomogeneous plasma near the critical density, an effect that is important for fusion applications and also occurs in the ionosphere. Overall, MGO can replace GO for any practical purposes, because it better handles cutoffs and is similar otherwise.

plasma waves↗

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($\$$434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗