Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Combined Effect of Contraction Ratio and Chamber Pressure on the Performance of a Gaseous Hydrogen-Liquid-Oxygen Combustor for a Given Propellant Weight Flow and Oxidant-Fuel Ratio

The effect of contraction ratio and chamber pressure on the combustion performance of a gaseous-hydrogen-liquid-oxygen combustor was investigated analytically and experimentally. The experiment was conducted with a "two-dimensional" gaseous-hydrogen-liquid-oxygen engine of about 150-pound thrust. The contraction ratio was varied from 1.5 to 6 by changing the nozzle throat area. This variation resulted in a chamber pressure variation of about 25 to 120 pounds per square inch. The experimental results were corrected for heat transfer to the engine walls and momentum pressure losses. The experimental performance, as evaluated in terms of characteristic exhaust velocity, was 98 percent of theoretical at contraction ratios greater than 3 but decreased very rapidly at smaller contraction ratios. The heat-transfer rate increased with increasing contraction ratio and chamber pressure; it was about 1 Btu per square inch per second at a contraction ratio of 1.5 and increased to about 3 at a contraction ratio of 6. The combined effects of contraction-ratio and chamber-pressure changes on performance were investigated analytically with a mixing model and a vaporization model. The mixing model predicted very poor mixing at contraction ratios below 3 and almost perfect mixing at higher contraction ratios. The performance predicted by the vaporization model was very close to 100 percent for all contraction ratios. From these results, it was concluded that the performance was limited by poor mixing at low contraction ratios and chamber pressures.

Hersch, Martin↗

Estimation of fan pressure ratio requirements and operating performance for the National Transonic Facility

The National Transonic Facility (NTF), a fan-driven, transonic, pressurized, cryogenic wind tunnel, will operate over the Mach number range of 0.10 to 1.20 with stagnation pressures varying from 1.00 to about 8.8 atm and stagnation temperatures varying from 77 to 340 K. The NTF is cooled to cryogenic temperatures by the injection of liquid nitrogen into the tunnel stream with gaseous nitrogen as the test gas. The NTF can also operate at ambient temperatures using a conventional chilled water heat exchanger with air on nitrogen as the test gas. The methods used in estimating the fan pressure ratio requirements are described. The estimated NTF operating envelopes at Mach numbers from 0.10 to 1.20 are presented.

Gloss, B. B.↗

Aerodynamic performances of three fan stator designs operating with rotor having tip speed of 337 meters per second and pressure ratio of 1.54. 1: Experimental performance

The aerodynamic performances of four stator-blade rows are presented and evaluated. The aerodynamic designs of two of these stators were compromised to reduce noise, a third design was not. On a calculated operating line passing through the design point pressure ratio, the best stator had overall pressure-ratio and efficiency decrements of 0.031 and 0.044, respectively, providing a stage pressure ratio of 1.483 and efficiency of 0.865. The other stators showed some correctable deficiencies due partly to the design compromises for noise. In the end-wall regions blade-element losses were significantly less for the shortest chord studied.

Gelder, T. F.↗

Performance of low-pressure-ratio fan stage at two off-design blade setting angles

The overall and blade-element performance of a low pressure ratio, low tip speed fan stage at design speed is presented for tow off-design rotor blade angle settings. The rotor design tip speed is 243.8 m/sec and weight flow per unit annulus area is 175.8 kg/sec. Design weight flow and pressure ratio are 29.9 kg/sec and 1.151, respectively.

Kovich, G.↗

Performance of low-pressure-ratio low-tip-speed fan stage with blade tip solidity of 0.65

The overall and blade-element performance of a low pressure ratio, low tip speed fan stage is presented over the stable operating range at rotative speeds from 90 to 120 percent of design speed. Stage peak efficiency of 0.927 was obtained at a weight flow of 32.4 kg/sec (190.31 kg/sec/sq m of annulus area) and a pressure ratio of 1.134. The stall margin at design speed and peak efficiency was 15.3 percent.

Kovich, G.↗

Performance of the Bowen ratio systems on a 22 deg slope

The Bowen ratio energy balance technique was used to assess the energy fluxes on inclined surfaces during the First ISLSCP Field Experiment (FIFE). Since air flow over sloping surface may differ from that over flat terrain, it is important to examine whether Bowen ratio measurements taken on sloping surfaces are valid. In this study, the suitability of using the Bowen ratio technique on sloping surfaces was tested by examining the assumptions that the technique requires for valid measurements. This was accomplished by studying the variation of Bowen ratio measurements along a selected slope at the FIFE site. In September 1988, four Bowen ratio systems were set up in a line along the 22 degree north-facing slope with northerly air flow (wind went up the slope). In July of 1989, six Bowen ratio systems were similarly installed with southerly air flow (the wind went down slope). Results indicated that, at distances between 10 to 40 meters from the top of the slope, no temperature or vapor pressure gradient parallel to the slope was detected. Uniform Bowen ratio values were obtained on the slope, and thus the sensible or latent heat flux should be similar along the slope. This indicates that the assumptions for valid flux measurements are reasonably met at the slope. The Bowen ratio technique should give the best estimates of the energy fluxes on slopes similar to that in this study.

Nie, D.↗

Multigrid convergence of an implicit symmetric relaxation scheme

Multigrid has been applied to an existing three-dimensional compressible Euler solver to accelerate the convergence of the implicit symmetric relaxation scheme. This lower-upper symmetric Gauss-Seidel implicit scheme is shown to be an effective multigrid driver in three-dimensions. A grid refinement study is performed including the effects of large cell aspect ratio meshes. Performance figures of the present multigrid code on Cray computers including the new C90 are presented. A reduction of three orders of of magnitude in the residual for a three-dimensional transonic inviscid flow using 920K grid points is obtained in less than 4 minutes on a Cray C90.

Yoon, Seokkwan↗

Multigrid convergence of an implicit symmetric relaxation scheme

The multigrid method has been applied to an existing three-dimensional compressible Euler solver to accelerate the convergence of the implicit symmetric relaxation scheme. This lower-upper symmetric Gauss-Seidel implicit scheme is shown to be an effective multigrid driver in three dimensions. A grid refinement study is performed including the effects of large cell aspect ratio meshes. Performance figures of the present multigrid code on Cray computers including the new C90 are presented. A reduction of three orders of magnitude in the residual for a three-dimensional transonic inviscid flow using 920 k grid points is obtained in less than 4 min on a Cray C90.

Yoon, Seokkwan↗

Multipurpose Rotating Rake Arrays for Integrated Inlet and Fan Stage Performance Measurement

Low-pressure-ratio fan stage performance measurement requires precise measurement of conditions upstream and downstream of the fan stage. This presentation will discuss the rotating rake arrays used for the recent Boundary Layer Ingesting Inlet-Distortion-Tolerant Fan experiment in the NASA Glenn 8 by 6 foot wind tunnel. To achieve precise measurements, simulations of the rake sampling from pre-test CFD (Computerized Fluid Dynamics) solutions were used to optimize the number and locations of rake instruments.

performanc↗

Aerodynamic performance of a 1.20-pressure ratio fan stage designed for low noise

The aerodynamic design and the overall blade element performance of a 51 centimeter diameter fan stage is presented. The stage was designed to minimize the noise generated by rotor stator interactions. The design pressure ratio was 1.20 at a flow of 30.6 kilograms per second and a rotor blade tip speed of 228.6 meters per second. At design speed the rotor peak efficiency was 0.935. The peak efficiency of the stage, however, was 0.824. The radial distribution of rotor performance parameters at peak efficiency and design speed indicated excellent agreement with design values.

Lewis, G. W., Jr.↗

Advances in materials and current collecting networks for AMTEC electrodes

Electrode materials for the Alkali Metal Thermal to Electric Converter (AMTEC) play a significant role in the efficiency of the device. RhW and PtW alloys have been studied to determine the best performing material. While RhW electrodes typically have power densities somewhat lower than PtW electrodes, PtW performance is strongly influenced by the Pt/W ratio. The best performing Pt/W ratio is about 3.4. RhW electrodes sinter more slowly than PtW and are predicted to have operating lifetimes up to 40 years; PtW electrodes are predicted to have lifetimes up to 7 years. Interaction with the current collection network can significantly decrease lifetime by inducing metal migration and segregation and by accelerating the sintering rate.

Ryan, M. A.↗

Experimental thrust performance of a high-area-ratio rocket nozzle

An experimental investigation was conducted to determine the thrust performance attainable from high-area-ratio rocket nozzles. A modified Rao-contoured nozzle with an expansion area of 1030 was test fired with hydrogen-oxygen propellants at altitude conditions. The nozzle was also tested as a truncated nozzle, at an expansion area ratio of 428. Thrust coefficient and thrust coefficient efficiency values are presented for each configuration at various propellant mixture ratios (oxygen/fuel). Several procedural techniques were developed permitting improved measurement of nozzle performance. The more significant of these were correcting the thrust for the aneroid effects, determining the effective chamber pressure, and referencing differential pressure transducers to a vacuum reference tank.

Pavli, Albert J.↗

Experimental thrust performance of a high area-ratio rocket nozzle

An experimental investigation was conducted to determine the thrust performance attainable from high-area-ratio rocket nozzles. A modified Rao-contoured nozzle with an expansion area of 1030 was test fired with hydrogen-oxygen propellants at altitude conditions. The nozzle was also tested as a truncated nozzle, at an expansion area ratio of 428. Thrust coefficient and thrust coefficient efficiency values are presented for each configuration at various propellant mixture ratios (oxygen/fuel). Several procedural techniques were developed permitting improved measurement of nozzle performance. The more significant of these were correcting the thrust for the aneroid effects, determining the effective chamber pressure, and referencing differential pressure transducers to a vacuum reference tank.

Pavli, A. J.↗

Numerical Investigation of Two-Stage Vapor Compression System with Simultaneous Vapor and Liquid Injection

Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.

component-based steady-state simulation↗