Search NASA⌕ Search

SEARCH · Search NASA

Results for “photodiode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Resolution of 100 photons and quantum generation of unbiased random numbers

Macroscopic quantum phenomena, such as observed in superfluids and superconductors, have led to promising technological advancements and some of the most important tests of fundamental physics. At present, quantum detection of light is mostly relegated to the microscale, where avalanche photodiodes are very sensitive to distinguishing single-photon events from vacuum but cannot differentiate between larger photon-number events. Beyond this, the ability to perform measurements to resolve photon numbers is highly desirable for a variety of quantum information applications including computation, sensing, and cryptography. True photon-number resolving detectors do exist, but they are currently limited to the ability to resolve on the order of 10 photons, which is too small for certain proposals. In this work, we extend photon measurement into the mesoscopic regime by implementing a detection scheme based on multiplexing highly quantum-efficient transition-edge sensors to accurately resolve photon numbers between zero and 100. Further, we then demonstrate the use of our system by implementing a quantum random number generator with no inherent bias. This method is based on sampling a coherent state in the photon-number basis and is robust against environmental noise, phase and amplitude fluctuations in the laser, loss and detector inefficiency as well as eavesdropping. Beyond true random number generation, our detection scheme serves as a means to implement quantum measurement and engineering techniques valuable for photonic quantum information processing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated optical frequency division for microwave and mmWave generation

Abstract The generation of ultra-low-noise microwave and mmWave in miniaturized, chip-based platforms can transform communication, radar and sensing systems 1–3 . Optical frequency division that leverages optical references and optical frequency combs has emerged as a powerful technique to generate microwaves with superior spectral purity than any other approaches 4–7 . Here we demonstrate a miniaturized optical frequency division system that can potentially transfer the approach to a complementary metal-oxide-semiconductor-compatible integrated photonic platform. Phase stability is provided by a large mode volume, planar-waveguide-based optical reference coil cavity 8,9 and is divided down from optical to mmWave frequency by using soliton microcombs generated in a waveguide-coupled microresonator 10–12 . Besides achieving record-low phase noise for integrated photonic mmWave oscillators, these devices can be heterogeneously integrated with semiconductor lasers, amplifiers and photodiodes, holding the potential of large-volume, low-cost manufacturing for fundamental and mass-market applications 13 .

Science & Technology - Other Topics↗

Design and optimization of high temperature optocouplers as galvanic isolation

The commercial InGaN-based (blue and green) and AlGaInP-based (red) multiple quantum well (MQW) lighting emitting diodes (LEDs) were studied in a wide range of temperatures up to 800 K for their light emission and detection (i.e., LEDs operated under reverse bias as photodiodes (PDs)) characteristics. The results indicate the feasibility of integrating a pair of selected LEDs to fabricate high temperature (HT) optocouplers, which can be utilized as galvanic isolation to replace the bulky isolation transforms in the high-density power modules. A detailed study on LEDs and PDs were performed. The external quantum efficiency (EQE) of the LED and PDs were calculated. Higher relative external quantum efficiency (EQE) and lower efficiency droops with temperatures are obtained from the blue and green LEDs for display compared with the blue one for lighting and red LED for display. The blue for lighting and red for display devices show superior responsivity, specific detectivity (D*), and EQE compared with blue and green for display when operated as PDs. The results suggest that red LED devices for display can be used to optimize HT optocouplers due to the highest wavelength overlapping compared with others.

42 ENGINEERING↗

Carbon conversion on biophotonic leaf

A photodiode can trigger bias-free redox reactions but is often hindered by thermodynamic barriers. Now, a bacteria-conjugated silicon biophotochemical diode allows simultaneous conversion of various carbon molecules with high efficacy.

60 APPLIED LIFE SCIENCES↗

High-throughput feedback-enabled optogenetic stimulation and spectroscopy in microwell plates

Abstract The ability to perform sophisticated, high-throughput optogenetic experiments has been greatly enhanced by recent open-source illumination devices that allow independent programming of light patterns in single wells of microwell plates. However, there is currently a lack of instrumentation to monitor such experiments in real time, necessitating repeated transfers of the samples to stand-alone analytical instruments, thus limiting the types of experiments that could be performed. Here we address this gap with the development of the optoPlateReader (oPR), an open-source, solid-state, compact device that allows automated optogenetic stimulation and spectroscopy in each well of a 96-well plate. The oPR integrates an optoPlate illumination module with a module called the optoReader, an array of 96 photodiodes and LEDs that allows 96 parallel light measurements. The oPR was optimized for stimulation with blue light and for measurements of optical density and fluorescence. After calibration of all device components, we used the oPR to measure growth and to induce and measure fluorescent protein expression in E. coli . We further demonstrated how the optical read/write capabilities of the oPR permit computer-in-the-loop feedback control, where the current state of the sample can be used to adjust the optical stimulation parameters of the sample according to pre-defined feedback algorithms. The oPR will thus help realize an untapped potential for optogenetic experiments by enabling automated reading, writing, and feedback in microwell plates through open-source hardware that is accessible, customizable, and inexpensive.

59 BASIC BIOLOGICAL SCIENCES↗

meso -Ethynyl-extended push–pull type porphyrins for near-infrared organic photodetectors

We report natural porphyrins play a key role in a range of vital functions such as oxygen transport in the bloodstream and the conversion of light to chemical energy in plants. Likewise, synthetic porphyrin derivatives can be used to detect light and convert it into an electrical current in photodiodes. The versatility of porphyrinoid chemistry allows to extend the absorptivity (and hence detectivity) to the near-infrared while maintaining good solubility, suitable electrochemical properties, and compatibility with the electron acceptor molecules required to achieve a reasonable photocurrent. Here, our efforts on the design and synthesis of novel push–pull type meso-ethynyl-extended porphyrin compounds, both of A–D–A and D–A–D type (D = donor, A = acceptor), and their evaluation in prototype near-infrared organic photodetector devices are presented. The push–pull design with strongly electron-deficient building blocks results in absorption onsets up to 1200 nm, translating in an optical gap approaching 1 eV. Both A–D–A and D–A–D small molecules show good photodetector performance, with a peak specific detectivity near 2 x 10 11 and 4 x 10 11 Jones at 1000 nm (at -2 V bias), respectively. These values are among the best reported so far for small molecule based near-infrared organic photodetectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors: I. Observations, impact on science, and modeling

Context.The Mid-Infrared Instrument (MIRI) on board theJames WebbSpace Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims.We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods.We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the publicPoisson_CCDcode. Results.We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10–25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Astronomy & Astrophysics↗

Ion temperature and rotation fluctuation measurements with ultra-fast charge exchange recombination spectroscopy (UF-CHERS) in the DIII-D tokamak

An upgraded detector and several optimizations have significantly improved the Ultra-Fast Charge Exchange Recombination Spectroscopy (UF-CHERS) diagnostic sensitivity to ion temperature and parallel velocity fluctuations at turbulence relevant spatio-temporal scales. Normalized broadband ion temperature and parallel velocity fluctuations down to x̃x∼1% (x = Ti, v∥) and up to ∼450 kHz have been measured in a variety of plasmas. The multi-field nature of the CHERS technique also allows measurements of the cross-phase angles of the fluctuating fields. UF-CHERS is optimized to observe emissions from the electron exchange reaction between intrinsic C6+ and hydrogenic neutral beam injected particles near 529 nm. UF-CHERS consists of two chords separated by ∼1 cm radially, less than the turbulence correlation length in DIII-D plasmas, which enables correlated measurements to suppress incoherent electronic and photon noise. The optical components of the spectrometer include a volume-phase-holographic grating with >90% transmission between 528 and 530 nm and f/2 200-mm lenses, selected to maximize the optical efficiency and photon flux. Diffracted light from each chord is collected in eight spectral bins, each with a bandwidth of ∼0.25 nm, and detected and amplified by chilled avalanche photodiodes and custom high-gain, wide bandwidth low-noise preamplifiers to achieve the optimal signal-to-noise ratio. The resulting signals are digitized at 1 MHz, 103–104× faster than the conventional CHERS diagnostics. Spatial coverage is achieved by repositioning a motorized fiber tray between plasmas. UF-CHERS measurements will advance the understanding of turbulent ion transport and contribute to the validation of transport models and simulations.

Truong, D. D. (ORCID:0000000285732539)↗

Effect of insulator surface conditioning on the pinch dynamics and x-ray production of a Ne-filled dense plasma focus

The dense plasma focus (DPF) can be an intense source of x rays, wherein the insulator sleeve strongly dictates the electrical breakdown, which subsequently affects the formation of a plasma sheath and a collapse phase. Experiments on a 25 kJ DPF (operated at 4.4 kJ) are carried out to demonstrate the influence of insulator surface morphology on the pinch structure, dynamics, and x-ray yield using a Ne fill. Two borosilicate insulators are directly compared, one with a smooth finish and the other machined with four circumferential grooves traversing the perimeter of the exterior insulator surface. Comparisons are made through same-shot imaging diagnostics of the evolving plasma sheath during breakdown, rundown, and at the pinch in addition to the time-resolved measurements of emitted x rays via filtered photodiodes. The presence of structures on the insulator sleeve reduces x-ray production across all fill pressures by a factor of 2.8 ± 2.4 on average and reduces the highest x ray producing shots by a factor of 5. ± 1.8. Observations of sheath asymmetry and inhomogeneity at lift-off are observed and correlated with subsequent observations of off-axis radial collapse. Taken together, this suggests that local variations in the insulator surface decrease the spatial uniformity of the sheath, leading to an azimuthally asymmetric focus, reduced electron densities, and, ultimately, degraded x-ray production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of the sub-aperture backscatter system on OMEGA EP

The sub-aperture backscatter (SABS) diagnostic on the OMEGA EP Laser System is a diagnostic that is used to measure the backscattered and sidescattered light during laser–plasma interaction experiments that are relevant to high-energy-density physics and inertial confinement fusion. The diagnostic collects stimulated Brillouin scattering (SBS) UV light at around 351 nm and stimulated Raman scattering (SRS) in the visible-light regime in the 420–720-nm-wavelength range and provides spectrally and temporally resolved information. Five 1-in. light collectors, composed of a lens, ground glass diffuser, and coupling into a 300-μm fiber, are positioned behind the last steering mirror on one of the four beamlines to catch a portion of the beam cross section (~1.5%) of the emission that is scattered into the beamline. The SRS light is collected in two light collectors, combined, and transported via graded index fibers to a streaked spectrometer. The SABS-SRS streak spectrometer has a temporal and spectral resolution of 100 ps and 1 nm, respectively. Three other light collectors collect, combine, and transport the SBS signal to a Hamamatsu high-voltage photodiode, where an oscilloscope digitizes the data, providing a time resolution of better than 1 ns. To obtain an absolute energy calibration of SRS measurements, light signals of known energy and wavelength were injected into the light collectors one at a time. The resulting counts on the streak camera charge-coupled device for SRS are then correlated with the incident fluence of scattered light at the light collector in order to allow a quantitative assessment of streak camera sensitivity to determine the energy of the scattered light during experiments. The measurements were performed in situ from the light collectors to the detectors. Other offline measurements provided the transmission of the optics between the target chamber center and the light collectors.

47 OTHER INSTRUMENTATION↗

High-bandwidth density silicon photonic resonators for energy-efficient optical interconnects

The growth of artificial intelligence applications demands ever larger and more complex deep learning models, dominating today's—and tomorrow's—data center and high-performance computing systems. While traditional electronics are failing to keep pace with application demands, silicon photonic (SiPh) interconnects have emerged as a necessary technology to support these systems. SiPh-driven wavelength-division multiplexing (WDM) offers a particularly promising path toward supporting incredibly high-aggregate link bandwidth in a compact and efficient form factor. One of the basic building blocks of these integrated WDM interconnects is the SiPh resonator. Their inherent wavelength selectivity and compact footprint allow for efficient data transmission multiplexed across dozens of carrier wavelengths. Used as add-drop (AD) filters, SiPh resonators are critical to constructing integrated tunable wavelength-selective optical circuit switches as well as for demultiplexing the different carrier wavelengths toward independent wavelength-insensitive photodiodes in a dense wavelength-division multiplexing receiver. Resonators in the all-pass (AP) configuration are widespread as well, allowing for wavelength-selective modulation to drive aggregate link bandwidths far beyond the individual channel data rate. Unlike SiPh Mach–Zehnder modulators (MZM), resonant modulators can be driven using low, complementary metal-oxide-semiconductor drive voltages, allowing for tight co-integration between photonic integrated circuits, fabricated with larger process node technologies, and electronic integrated circuits, designed to exploit the advantages of the latest node. To push toward practical peta-scale interconnects, a comprehensive review of SiPh resonators is required, addressing bottlenecks and design constraints at both the architecture and device levels. We first describe the predominant integrated link architectures and identify their limits. We then discuss the device-level design considerations that can be made for both AD and AP configuration resonators to overcome the system level limits with novel resonator device designs. Analytical models and numerical simulation of resonators are validated by experimental measurement of devices fabricated in a commercial 300-mm foundry, showing a clear path toward volume manufacturing. The demonstrated resonant modulators and filters support the feasibility of increasing the aggregate bandwidth of resonator-driven SiPh interconnects into the peta-scale regime.

42 ENGINEERING↗

Fast and efficient Sb-based type-II phototransistors integrated on silicon

Increasing the energy efficiency and reducing the footprint of on-chip photodetectors enable dense optical interconnects for emerging computational and sensing applications. While heterojunction phototransistors (HPTs) exhibit high energy efficiency and negligible excess noise factor, their gain-bandwidth product (GBP) has been inferior to that of avalanche photodiodes at low optical powers. Here, we demonstrate that utilizing type-II energy band alignment in an Sb-based HPT results in six times smaller junction capacitance per unit area and a significantly higher GBP at low optical powers. These type-II HPTs were scaled down to 2 μm in diameter and fully integrated with photonic waveguides on silicon. Thanks to their extremely low dark current and high internal gain, these devices exhibit a GBP similar to the best avalanche devices (∼270 GHz) but with one order of magnitude better energy efficiency. Their energy consumption is about 5 fJ/bit at 3.2 Gbps, with an error rate below 10−9 at −25 dBm optical power at 1550 nm. These features suggest new opportunities for creating highly efficient and compact optical receivers based on phototransistors with type-II band alignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reward based optimization of resonance-enhanced piezoresponse spectroscopy

Dynamic spectroscopies in scanning probe microscopy (SPM) are critical for probing material properties, such as force interactions, mechanical properties, polarization switching, electrochemical reactions, and ionic dynamics. However, the practical implementation of these measurements is constrained by the need to balance imaging time and data quality. Signal to noise requirements favor long acquisition times and high frequencies to improve signal fidelity. However, these are limited on the low end by contact resonant frequency and photodiode sensitivity and on the high end by the time needed to acquire high-resolution spectra or the propensity for sample degradation under high field excitation over long times. The interdependence of key parameters such as instrument settings, acquisition times, and sampling rates makes manual tuning labor-intensive and highly dependent on user expertise, often yielding operator-dependent results. These limitations are prominent in techniques like dual amplitude resonance tracking in piezoresponse force microscopy that utilize multiple concurrent feedback loops for topography and resonance frequency tracking. Here, a reward-driven workflow is proposed that automates the tuning process, adapting experimental conditions in real time to optimize data quality. Furthermore, this approach significantly reduces the complexity and time required for manual adjustments and can be extended to other SPM spectroscopic methods, enhancing overall efficiency and reproducibility.

47 OTHER INSTRUMENTATION↗

A profile monitor for proton radiography experiments at the Los Alamos Neutron Science Center

The Proton Radiography (pRad) facility at the Los Alamos Neutron Science Center utilizes pulses of protons delivered by the 800 MeV linear accelerator to produce a series of radiographic images to study the dynamic behavior of materials under extreme conditions. Radiographs taken with an empty field of view, or beam pictures, are used to normalize transmission. However, because the center of the proton beam shifts between pulses, an in situ method for measuring beam position is required to normalize images for beam movement to perform absolute radiography. The beam profile monitor described here uses an array of scintillating fibers positioned in the beam path to produce light proportional to beam intensity across the beam cross section. This light is detected using fast photodiodes and a digital oscilloscope, providing a response time of several nanoseconds—suitable for measuring the 50-ns proton pulses used in pRad. The profile monitor achieves a measured position precision of 40 μm and an intensity precision of 0.7%, allowing for beam movement corrections to be applied to images, thereby improving data accuracy and image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introducing new resonant soft x-ray scattering capability in SSRL

Resonant soft x-ray scattering (RSXS) is a powerful technique for probing both spatial and electronic structures within solid-state systems. Here, we present a newly developed RSXS capability at beamline 13-3 of the Stanford Synchrotron Radiation Lightsource, designed to enhance materials science research. This advanced setup achieves a base sample temperature as low as 9.8 K combined with extensive angular motions (azimuthal ϕ and flipping χ), enabling comprehensive exploration of reciprocal space. Two types of detectors—an Au/GaAsP Schottky photodiode and a charge-coupled device detector with over 95% quantum efficiency—are integrated to effectively capture scattered photons. Extensive testing has confirmed the enhanced functionality of this RSXS setup, including its temperature and angular performance. The versatility and effectiveness of the system have been demonstrated through studies of various materials, including superlattice heterostructures and high-temperature superconductors.

Kuo, Cheng-Tai [SLAC National Accelerator Laborato↗

Microwave-photonic control of optically accessible spin defects in diamond

A growing variety of optically accessible spin qubits have emerged in recent years as key components for quantum sensors, computers, and memories. However, the scalability of conventional spin-based quantum architectures remains limited by direct microwave delivery, which introduces thermal noise, electromagnetic crosstalk, and design constraints for cryogenic, high-field, and distributed systems. In this work, we present a unified framework for RF-over-fiber (RFoF) control of spins accessible through optically detected magnetic resonance (ODMR) spectroscopy of nitrogen-vacancy (NV) centers in diamond. The RFoF platform relies on an intensity-modulated 1310 nm laser carrying microwave signals over fiber and a high-speed photodiode for optical-to-electrical conversion to drive NV spin transitions. We report an RFoF power-conversion efficiency of 3.42% for an RF output PRF,out=-5.5 dBm at 2.87 GHz, enabling clear resolution of Zeeman splitting in

Rahman, M Reefaz [ORNL] (ORCID:0000000323541611)↗

Identification of dislocation-related and point-defects in III-As layers for silicon photonics applications

Abstract The aim of this paper is to identify, analyze and compare the defects present in III-As, as a function of dislocation density, and as a function of the presence/absence of quantum dots (QDs). Such materials are of fundamental importance for the development of lasers and photodiodes for silicon photonics. The study is based on an extensive deep-level transient spectroscopy investigation, carried out on GaAs pin diodes grown on Si and on GaAs (that differ in the dislocation density), with and without embedded QDs. The original results described in this paper demonstrate that: (a) we were able to identify four different defects within the device grown on Si (three electron and one hole traps) and one defect (hole trap) in the device on GaAs, common to both samples; (b) all the majority carrier traps identified are located near midgap, i.e. are efficient non-radiative recombination centers; (c) such defects are absent (or non-detectable) in the sample grown on GaAs substrate, having a very low dislocation density; (d) the presence of QDs does not result in additional defects within the semiconductor material; (e) the analysis of the capture kinetics revealed that two of the identified traps are related to point defects, whereas the other two traps can be associated with point defects located near a dislocation; (f) a comparison with previous reports indicate that the detected traps are related to native III-As defects, or to oxygen-related complexes.

Physics↗

Synthetic modeling of soft x-ray emissivity for magnetic island analysis in LTX-β

We present a synthetic soft x-ray (SXR) forward-modeling framework that characterizes the emissivity structure of rotating magnetic islands in the Lithium Tokamak eXperiment-β across space and time. Magnetic islands associated with tearing modes produce modulations in line-integrated SXR brightness. Traditional tomographic methods struggle to resolve these structures in devices with limited sightlines, resulting in an under-determined inversion problem, or otherwise necessitate equilibrium reconstruction data, preventing their use in active control. Our approach removes this challenge by combining a fully three-dimensional ray-tracing model with a time-dependent emissivity prescription of a $m/n$ = 2/1 magnetic island. The model is validated through helical island geometry, rotation measured by magnetic diagnostics, and equilibrium constraints from PSI-Tri reconstructions. Synthetic brightness signals are generated for each photodiode sightline from a modeled emissivity profile and directly compared with experimental data from a tangential midplane SXR array. By fitting the synthetic diagnostic output to the observed brightness across time, we simultaneously infer key geometric parameters-such as island radial location, island width, and rotation frequency-without requiring full tomographic reconstruction, all with an average absolute deviation of less than 3%. This work demonstrates that forward modeling with a single tangential array can extract key island parameters in a spherical tokamak, providing a computationally efficient alternative to conventional SXR tomography and providing a pathway toward real-time magnetic-island characterization in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗