Search NASA⌕ Search

SEARCH · Search NASA

Results for “pinhole”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A Study of the Ultraviolet Radiation of Hybrid X-Pinches

The results of an experimental study of hybrid X-pinches (HXPs) as sources of vacuum ultraviolet (VUV) radiation within the wavelength range of λ < 2000 Å are presented here. A KING compact low-voltage generator (45 kV, 200 kA, 190 ns) was used to feed the X-pinches. The dynamics of forming the radiating plasma of HXPs of different materials were studied using pinhole cameras with radiation receivers based on microchannel plates with a time resolution of 5 ns and a spatial resolution of 150 µm. The time structure and energy characteristics of the radiation were studied using diamond photoconducting detectors (PCDs). The spectral composition of UV radiation was investigated using a spectrograph based on the transmission grating. It has been shown that the efficiency of conversion of the capacitor-stored energy to the VUV radiation may reach 5%, whereas the fraction of soft X-rays (SXR) with quanta energies above 800 eV is no more than 3%. In this case, the source brightness reaches 2 × 10 9 W/(sr cm 2 ).

plasma UV-spectroscopy↗

Investigation of Membrane Chemical Degradation as a Function of Catalyst Platinum Loading

Membrane chemical degradation is one of many factors that can impact fuel cell durability. Additionally, the fuel cell’s lifetime heavily depends on the membrane and its ability to maintain chemical and mechanical integrity. Previous studies indicate that chemical degradation is due to the formation of hydroxyl radicals that attack the polymer structure resulting in membrane thinning, pinhole formation, and the release of fluoride and sulfate ions. Membrane durability was investigated using ultra-low Pt electrode loadings (≤ 0.1 mg Pt cm -2 ). Accelerated stress testing (US-DOE protocols) demonstrated that the degradation rate was found to increase with higher Pt loadings. This is most likely due to more heterogeneous sites for radical formation due to hydrogen crossover to the cathode. We also explored membrane degradation rates while varying catalyst layer thickness, ionomer to carbon ratio, and types of carbon support. All of the aforementioned variables impact the membrane degradation rates.

25 ENERGY STORAGE↗

Development of a position–velocity–time-modulated two-dimensional ion beam figuring system for synchrotron x-ray mirror fabrication

With the rapid evolution of synchrotron x-ray sources, the demand for high-quality precision x-ray mirrors has greatly increased. Single nanometer shape accuracy is required to keep imaging capabilities at the diffraction limit. Ion beam figuring (IBF) has been used frequently for ultra-precision finishing of mirrors, but achieving the ultimate accuracy depends on three important points: careful alignment, accurate dwell time calculation and implementation, and accurate optical metrology. The Optical Metrology Group at National Synchrotron Light Source II has designed and built a position–velocity–time-modulated two-dimensional IBF system (PVT-IBF) with three novel characteristics: (1) a beam footprint on the mirror was used as a reference to align the coordinate systems between the metrology and the IBF hardware; (2) the robust iterative Fourier transform-based dwell time algorithm proposed by our group was applied to obtain an accurate dwell time map; and (3) the dwell time was then transformed to velocities and implemented with the PVT motion scheme. In this study, the technical aspects of the PVT-IBF systems are described in detail, followed by an experimental demonstration of the figuring results. In our first experiment, the 2D RMS in a 50mm×5mm clear aperture was reduced from 3.4 to 1.1 nm after one IBF run. In our second experiment, due to a 5 mm pinhole installed in front of the source, the 2D RMS in a 50mm×5mm clear aperture was reduced from 39.1 to 1.9 nm after three IBF runs, demonstrating that our PVT-IBF solution is an effective and deterministic figuring process.

47 OTHER INSTRUMENTATION↗

Robust COTS objective for diffraction-limited, high-NA, long front working distance imaging

We present a robust objective lens optimized for applications requiring both high numerical aperture (NA) and long front working distance imaging, comprised of all commercial-off-the-shelf (COTS) spherical singlet lenses. Unlike traditional designs that require separate collimation and refocusing stages, our approach directly converges imaged light to the back focal plane using a single lens group. Our configuration corrects spherical aberrations and efficiently collects light to achieve diffraction-limited performance across a wide range of wavelengths while simplifying alignment and assembly. Using this approach, we design and construct an example objective lens that features a long front working distance of 61 mm and a clipped NA of 0.30 (limited by an aperture in our experimental setup). We experimentally verify that it achieves monochromatic diffraction-limited resolution at wavelengths from 375 nm to 866 nm without requiring replacement of the lenses or changing the inter-lens spacings, and its performance remains robust across a 46 mm range variation in total length (by adjusting mainly the back working distance). Additionally, we develop a quantitative method to measure the field of view (FOV) using an experimentally calibrated pinhole target. Under 397 nm illumination (i.e., from 40 Ca + ion fluorescence), the objective achieves a resolution of 0.87 μm with a 540 μm FOV. This robust, all-COTS, and versatile design is well-suited for a broad range of experiments, supporting high-precision measurements and exploring quantum phenomena.

Cui, Jiafeng [Oak Ridge National Laboratory (ORNL)↗

ENGR 399 Final Report for NIS1U Manipulator

This summer project focused on the design and analysis of a device, denoted the manipulator, that can produce pitch and yaw manipulations to precisely align the pinhole array to the target chamber center within the National Ignition Facility. This manipulation device is limited by many factors and expected to meet strict performance requirements, so rigorous design work was done to ensure a robust concept was formed. This design work included the preliminary analysis ofthree diverse concepts, developing each concept to meet necessary requirements, secondary analysis, creation ofPugh matrix to support final concept choice, and optimization ofthe final choice. To do so, three concepts with diverse driving mechanisms were developed, analyzed, scored and the best performing concept was chosen.

42 ENGINEERING↗

Kinetics of TATB and LX-17 Decomposition by Thermal Analysis

The kinetics of TATB decomposition have been investigated by thermal analysis (thermogravimetric analysis, TGA, and differential scanning calorimetry, DSC) at both LLNL and the University of Alabama Birmingham. This report summarizes progress in understanding from those results within the context of identifying the global reaction mechanism, i.e., sequential, autocatalytic, competitive, or some mixture thereof. A particularly important issue is how pressure affects both the reaction rate and enthalpy. The effect of pressure helps identify dominant mechanisms and construct and constrain a global mechanism that will work over a wide range of conditions. This memorandum is simply a snapshot of current progress and not a definitive interpretation. I have written it to organize work of others and my interpretations in a systematic manner with the intention of stimulating further advances in understanding. SDT data comes from Jen Montgomery at LLNL, and high-pressure DSC comes from Victoria Stanford and Sergey Vyazovkin at University of Alabama at Birmingham. Major observations and conclusions, some new and some not, are (1) outgassing below 150 °C prior to decomposition releases adsorbed water vapor, (2) outgassing between 150 and 250 °C may come primarily from intercalated water (3) initial thermal decomposition above 250 °C or so involves dehydration of TATB to create furazans, (4) quickly heating to higher temperatures in open pans with flowing gas leads primarily to TATB evaporation between 270 and 390 °C, (5) using a pinhole crucible at atmospheric pressure largely eliminates TATB sublimation, (6) at typical thermal analysis heat rates, the main stage of decomposition is described by a single mass loss process, and decomposition of residual material is spread over a wide range of thermal severity, (7) at typical thermal analysis heat rates and constant temperatures above 300 °C, heat release occurs in two overlapping peaks, with the first one a little faster than mass loss and the second on a little slower than mass loss, (8) total heat release increases significantly with heating rate and substantially with increased pressure, and (9) isothermal experiments at 340 °C indicate that the first exotherm increases by more with LX-17 than TATB, which suggests a possible chemical role of Kel-F decomposition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Throughput In-Line Coating Metrology Development for Solid Oxide Fuel Cell Manufacturing

Coatings play key roles in solid oxide fuel cell (SOFC) stack durability. For example, diffusion barrier coatings on Cr-containing interconnect and balance of plant (BOP) components protect electrodes from Cr poisoning over the long operational lifetimes (>10,000 hours) of the fuel cell stack. Common defects in coatings, such as cracks, pinholes, and porosity, result in a failure to protect the electrodes, resulting in shorter operational lifetime and thus higher cost. It is very unlikely, even in the best coating process, that all these defects can be mitigated, hence identifying critical defects in parts, and removing defective parts from production before they can damage the stack, becomes paramount. Furthermore, these quality control techniques must be operational in the production/assembly line (in-line), i.e., high throughput and non-destructive, and cost effective. Redox Power Systems, LLC (Redox) together with the National Renewable Energy Laboratory (NREL) developed much needed high throughput, in-line metrology techniques for protective coatings. The overall goal of the project is to lower cost while increasing robustness, reliability, and endurance of SOFC stacks. To accomplish this, we had several objectives, including: to identify key coating and substrate defects that lead to coating failure through the use of detailed characterization methods (e.g., microscopy, XRD, EDS, electrochemistry); to assess capabilities of in-line metrology techniques, e.g., optical profilometry (Redox) and thermography (NREL), to probe these defects, or evidence thereof; demonstrate long-term performance of “defect-free” protective coatings, as identified by in-line metrology, in solid oxide fuel cell (SOFC) stack operation. In the first part of this project, the ability to identify key defects expected to lead to coating and SOFC degradation using in-line metrology tools were evaluated. Coated interconnect samples with controlled defect types and populations were tested under conditions similar to SOFC operation, followed by detailed post-test analysis to reveal the defects responsible for observed degradation. In the second part of the project, the optimal in-line metrology techniques and methodologies were used to map the defect distribution in full-size interconnects with critical defects intentionally allowed to exist in some cases. These interconnects underwent SOFC testing for extended periods (up to ~3,000 hours) followed by post-test analysis to evaluate the effectiveness of in-line metrology techniques in mitigating MCO coating related degradation. Key accomplishments in this project included the following: Demonstrated ASR of < 0.05 ohm-cm 2 at 650 °C for 1,000 hours with low defect (determined by in-line metrology) interconnect samples (average ASR=37 milliohms-cm 2 after over 1,000 hours). Demonstrated that low defect coatings on interconnects (as screened using in-line metrology) have low volatilization of chromium at ~650 °C for 1,000 hours as detected using Cr-getter material (< 5 at% increase above baseline); 1022 hour duration tests under humidified, elevated temperature (750 °C rather than 650 °C) compared a base case against different coating thicknesses. Demonstrated capability to identify initial key defects of interest with in-line metrology techniques using up to 8 cm by 10 cm having coatings with and without intentional defects of interest using thermal imaging and optical profilometry. Correlated key defects identified using metrology techniques with observed coating performance (e.g., ASR and Cr volatility). Conducted several 4 cm by 4 cm cell tests using MCO-interconnects that were pre-screened using some of the metrology techniques developed in the project (e.g., optical profilometry). An analysis of ASR measurements were able to show that defect-free coatings resulted in the anticipated performance in the cell tests.

01 COAL, LIGNITE, AND PEAT↗

An X-ray Intensity Operations Monitor (AXIOM) (Final LDRD Project Report)

The Saturn accelerator has historically lacked the capability to measure time-resolved spectra for its 3-ring bremsstrahlung x-ray source. This project aimed to create a spectrometer called AXIOM to provide this capability. The project had three major development pillars: hardware, simulation, and unfold code. The hardware consists of a ring of 24 detectors around an existing x-ray pinhole camera. The diagnostic was fielded on two shots at Saturn and over 100 shots at the TriMeV accelerator at Idaho Accelerator Center. A new Saturn x-ray environment simulation was created using measured data to validate. This simulation allows for timeresolved spectra computation to compare the experimental results. The AXIOM-Unfold code is a new parametric unfold code using modern global optimizers and uncertainty quantification. The code was written in Python, uses Gitlab version control and issue tracking, and has been developed with long term code support and maintenance in mind.

43 PARTICLE ACCELERATORS↗

Reducing roughness and improving efficiency of MAPbI3 perovskite solar cells made by high-throughput photonic curing

For perovskite solar cells (PSCs) to be commercially viable, the slow and energy-insufficient thermal annealing step must be eliminated. Among the photo-irradiation methods proposed to replace thermal annealing, photonic curing is the fastest conversion method. Photonic curing delivers short (20 μs to 100 ms) but intense light pulses from a broadband (200-1500 nm) xenon flash lamp, making it the only method to convert perovskite under 20 ms. This processing time can be extrapolated to a roll-to-roll web speed of 40 m/min based on laboratory processing conditions. However, most reported PSCs made by photonic curing under 1 second have inferior performance (~10% PCE). Although SEM images show dense and pinhole-free perovskite films, AFM images indicate secondary wavy features of 500 nm-wide ridge and 80 nm-deep trenches on photonically cured perovskite films, the existence of which correlates with poor device performance. We suggest that this morphology feature is produced by volatile solvent evaporation during the fast photonic curing process. Two approaches have been made to remedy this issue: (1) adding CH2I2 as the third solvent in the conventional DMF-DMSO system and (2) applying a controlled air-blowing step before photonic curing to remove excess solvent further. Combining these two approaches produces photonically- cured perovskite films with a comparable film roughness and device performance. Alkyl halide additives have been reported to enhance PSC performance by modulated solvent-solute interactions and C-X (X = Cl, Br, and I) cleavage. Photonic curing can cleave CH2I2, producing disassociated iodide ions to replenish iodine loss induced by photonic curing, which is confirmed by EDX. As a co-solvent, the high boiling point of CH2I2 can also make the solvent less volatile, reducing surface roughness in photonically cured perovskite films. Additionally, photonically-cured perovskite films have longer PL lifetimes and a higher recombination resistance compared to thermally-annealed counterparts. As a result, we demonstrate that photonic curing is a suitable method to replace thermal annealing in high-throughput PSC fabrication.

14 SOLAR ENERGY↗

Specifications of FIPD Fission Gas Release Data

All fission gas release data stored in the Fuels Irradiation & Physics Database (FIPD) was originally measured using the Gas Assay, Sample and Recharge (GASR) System in the Hot Fuel Examination Facility (HFEF). It is therefore called GASR data in FIPD. During the measurement of a sample, such as an irradiated EBR-II fuel element/capsule, a pinhole-sized region near the top of the element plenum was melted by a laser. Plenum gas then expanded into a calibrated volume (note: in this document, “sample” and “capsule/element” are used interchangeably consistent with GASR documents in FIPD). The pressure rise in the volume was recorded. Helium backfilling and expansion was then performed to determine the sample (e.g., fuel element plenum) volume using Boyle’s Law and assuming ideal gas behavior at constant temperature. With the plenum volume and the recorded pressure rise, the sample (e.g., fuel element plenum) pressure was derived with assumption of ideal gas law behavior. The plenum volume and pressure as well as the cladding temperature during the measurement were collected (GASR data in FIPD). Other records associated with the fission gas release data include: raw GASR data records including volumes and post-puncture pressures of seal head/sealing head and manifold, calibration data, backfilling gas pressure data, and the data analysis records. A sample(s) of the fission gas released from the plenum was collected by the GASR system into sample bottles. The chemical and isotopic composition of the gas sample was analyzed separately from GASR data, and will be discussed in a separate specification. The plenum volume, pressure, and cladding temperature during the measurement are typically utilized to determine the number of moles of gas in the plenum. This quantity is often compared to the number of moles of gas generated by fission events. However, calculating these values and their associated uncertainty is beyond the scope of this document, as it necessitates additional assumptions. The most important document to understand the FIPD fission gas data is the GASR operational manual (title: Gas Assay, Sample and Recharge System (GASR) operation and maintenance manual, HFEF/N OMM 4381, DOC. NO. W0018-0032-ES-00). This manual provides: (1) description of the GASR and the functions of each component (laser drilling, welding, seal head/sealing head, manifold, vacuum system, sample system, purge and gas tag system, etc.); (2) step-by-step guidance on calibrations, operations, and measurements; and (3) maintenance procedures and other details relating to the structure and operation of the GASR. Note that the original GASR operated until 2020. A new GASR with the same design and measurement methodology was installed in 2021. The specifications of the GASR presented on the HFEF website at this time are consistent with the ones given in the operational manual. The methods to calculate the plenum volume and pressures were not included in the operational manual, but were recorded in the legacy data analysis files. Details of the methods are given in Chapter 3.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Short-Pulse Laser-Based Diagnostics for Pulsed Power-Driven Warm Dense Matter

This report summarizes a research project conducted at the Physics Department’s Zebra Pulsed Power Laboratory (ZPPL) at the University of Nevada Reno, aimed at developing short-pulse laser-based diagnostics to probe pulsed-power-driven warm dense matter. ZPPL combines a MegaAmpere (MA) pulsed power generator, Zebra, and a relativistic intensity, short-pulse laser, Leopard, offering a unique university-scale platform for high energy density physics, laboratory astrophysics, and inertial fusion energy research. The project focused on establishing a hard X-ray radiographic capability using high-intensity, short-pulse laser-generated X-rays to probe warm dense matter created by the Zebra current. Initial experiments produced X-ray radiographs of a static (cold) aluminum wire using silver and gold foil and wire targets, but intense background radiation from Zebra shots overwhelmed the laser-produced X-rays. To mitigate this, a radiationhardened detector housing was designed and implemented. Additional diagnostic, including a filter stack bremsstrahlung spectrometer and an X-ray pinhole camera, were developed to characterize laser-produced hard X-ray spectra and locate hard X-ray sources in the vacuum chamber. These revealed that strong hard X-rays (> 20 keV) originated near the anode cap, bombarded by energetic electrons. Due to laser unavailability during some experiments, detector performance was successfully tested using hard X-ray sources from the Zebra current, demonstrating their readiness for coupled experiments. The project supported one Ph.D. student (Dr. Lei Chen), who conducted experimental and numerical research, and provided training opportunities and data for three undergraduate senior theses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hard x-ray imaging and characterization of staged z-pinch plasmas in order to exclude ion beams as cause of fusion

Prior to the start of the INFUSE project, a 1-D x-ray device had been developed to detect > 5 keV x-rays and, by using the device as a pinhole camera, determine the location of the source of these x-rays. The system was also used in a non-camera mode to measure the energy of the X-rays by having different thicknesses of attenuating material on different pixels. This dual-purpose had been used in three plasma experiments: the laboratory magnetized plasma jet at Caltech, the laboratory solar nanoflare at Caltech, and at the 500 kA staged Z-pinch (CESZAR) at UCSD. Preliminary measurements at the UCSD facility indicated that hard x-rays with energies ranging from ~27 to over 100 keV were created and that these x-rays likely originated at the Z-pinch’s anode. These preliminary data also indicated that the x-rays’ origin was coincident with the moment of peak compression. The major goal of the INFUSE proposal was to confirm these preliminary results. This confirmation was to be made by improving the imaging capability to two dimensions, increasing the time resolution of the camera, and using the x-ray diagnostic alongside time-resolved neutron detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fitness For Service Assessment of a Corroded Heat Exchanger

Within the Fermi National Accelerator complex, there exist various water systems that support accelerator operations. One of these systems is extremely vital to the operation of the machine; that is the cooling system. The cooling system consists of nine relatively large heat exchangers that take untreated pond water and use it to cool the process fluid that further cools machine components. Over the 30 years these heat exchangers have been in operation, they have undergone significant material loss on the channels. This material loss, due to various forms of corrosion such as galvanic and microbiologically influenced corrosion (MIC) and possibly others, has deteriorated more than 80% of the nominal wall thickness of some of the exchangers and placed them in a questionable state. ASME FFS-1 (API 579) has been applied to address the condition of the heat exchangers due to their noncompliance with the governing code, BPVC Sec. VIII Div. 1. The assessments encompassed ASME FFS-1 parts 4: General Metal Loss and 9: Crack Like Flaw using level 1, 2, and 3 analysis techniques based on inspection data obtained by API 510 inspections. Level 1 and 2 assessments were deemed unfit for the corroded regions due to their location relative to a major structural discontinuity (channel to tube-sheet joint), so a level 3 analysis was conducted according to ASME Sec. VIII Div. 2 (design by analysis) rules for pressure vessels. Supplemental information included pond water tests to determine an accurate future corrosion allowance due to lacking inspection history. A leak before break (LBB) route was chosen to evaluate the possibility of leaking prior to the onset of failure. The analysis of one heat exchanger shows that the possibility the channel will develop a pinhole leak over 2.5 more years of operation should not be overlooked, but burst was unlikely from operation. The use of fracture mechanics show, that if a through-wall crack were to develop, it would not propagate further than the channel geometry and cause a leak not greater than 35 GPM. Using ASME Section XI Code Case N-705-1, allowing us to operate with a leak until the next outage given certain operating conditions and developing a leak mitigation procedure, this heat exchanger is deemed fit-for-service.

Humenik, Alex [Fermilab]↗

Investigating the Impact of Absorbed Surface Impurities (CO, CO 2 , CH 4 , and H 2 O) on Getter Rate Performance

This report provides an overview of engineering and experimental efforts to establish a new capability for measuring H2 uptake rates for Tritium Producing Abosrber Rod (TPBAR) getter materials. This new system was used to gain a better understanding of the impact of contaminant species (CO 2 , CO, CH 4 , and H 2 O) on getter performance under relevant hydrogen uptake conditions (350 °C, 20 torr). Herein, we successfully established a high-resolution gravimetric sorption (HRGS) system in a flow through configuration that can measure sample mass changes with high resolution (1 µg or 10 µg) over long experiment times (days), high temperature, and varying pressures. We coupled this capability with an in-line universal gas analyzer (UGA) system to characterize potential surface chemistry side reactions occurring after contaminant gas exposure. The major findings of this study suggest that methane and CO have the most detrimental effects on getter H 2 uptake performance showing large changes in rate after exposure compared to CO 2 and water. The effect of these contaminant species did not influence getter sample capacity (~ 1.8 wt% H 2 ). After CO and methane exposure, changes in getter rate were accompanied by observable Ni-surface defects and pinholes via SEM imaging suggesting possible Ni- layer corrosion. Additionally, the increase in C and O signal in the zircaloy layer, observed via EDX, point to C and O species transport through the getter sample resulting in the formation of carbides and oxide species. Thus, co-exposure studies where mixed gases or water vapor are introduced together will be important to further understand what mechanisms are contributing to Ni-layer corrosion and changes in getter performance.

36 MATERIALS SCIENCE↗

Complete time-resolved X-ray shape capability for a 10 MJ implosion: Milestone Report for MRT 8818

This report documents completion of MRT 8818, which established an upgraded equatorial time-resolved X-ray imaging capability for high-yield inertial confinement fusion experiments at the National Ignition Facility (NIF) using the equatorial Dilation X-ray Imager (DIXI). The need for this work arose from the sustained increase in fusion yield at NIF, which progressively intensified the neutron and gamma-ray environment experienced by target diagnostics. Although the existing polar imaging capability, particularly the Polar Dilation X-ray Imager (PDIXI), remained viable at high yields, the equatorial capability became inadequate because of radiation-induced failure of electronic readout hardware and increasing background levels that degraded image quality and ultimately caused saturation. The work performed under MRT 8818 addressed this limitation through a combination of hardware replacement, background characterization, and targeted mitigation. The DIXI backend was converted from CCD-based electronic readout to photographic film, and the principal sources of internally generated background were investigated using prior analyses, dedicated tests, and comparison with PDIXI performance on high-yield shots. This effort led to implementation of two principal improvements: a multilayer optical coating to suppress broadband radiation-induced background generated in the fiber-optic extension cylinder, and replacement of Kodak TMAX 400 film with Agfa Copex Rapid to reduce background generated directly in the film. These upgrades were completed in 2025 and performance assessment based on DT shot data since then, comparing with Polar DIXI and scaling of these experiments to 10 MJ indicates an expected signal-to-background ratio of approximately 34 for a single pinhole image, substantially exceeding the MRT 8818 completion criterion of SNR > 5.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Boride-Carbon Hybrid Technology for Ultra-Wear and Corrosive Conditions

This work discusses a study on a surface treatment for creating extremely durable low-friction, wear and corrosion-resistant surfaces for tribological components in harsh conditions. A duplex surface treatment was developed that combines the advantages of ultra-fast electrochemical boriding with those of hard tetrahedral amorphous carbon coatings. The friction and wear properties of the duplex treatment are compared to the boride-only treatment of AISI 1045 steel, while corrosion and contact fatigue behaviors of the duplex layer are compared to that of the single-layer carbon coating on low carbon steel. The duplex treatment yields wear rates as low as 6 × 10−8 mm3·N−1·m−1 and a coefficient of friction of 0.14 when tested against a steel counter face. The contact fatigue impact tests reveal that the high hardness of 1200 HV0.05 of the borided layer in the duplex treatment leads to higher resistance against indentation but is accompanied by a higher incidence of crack initiation, being in good agreement with the finite-element modeling of nanoindentation results. The duplex coatings exhibit resistance to pinhole corrosion as evidenced by a 3 h exposure to 15% HCl at room temperature.

36 MATERIALS SCIENCE↗

Influence of Oxygen Flow and Stoichiometry on Optical Properties and Damage Resistance of Hafnium Oxide Thin Films

Hafnium oxide (HfO 2 ) is predominantly used as a high-index material in multi-layer dielectric coatings for high-peak- and high-average-power lasers, but laser damage often initiates within the HfO 2 layers despite their wide bandgap. Oxygen deficiency during deposition can introduce vacancy-related sub-bandgap states and absorptive defects, lowering damage resistance. This study investigates how oxygen flow during HfO 2 deposition with ion beam sputtering (IBS) affects its stoichiometry, defect formation, and nanosecond laser-induced damage threshold (LIDT) and whether single-layer trends predict multilayer performance. Single layers were deposited at varying oxygen flows, characterized for optical and structural properties, and tested for the LIDT at 1064 nm and 355 nm. Increasing oxygen flow drove the layer toward near-stoichiometric HfO 2 , reduced the refractive index, and altered the density of surface pinhole-like features. The single-layer LIDT at 355 nm increased with oxygen, whereas the 1064 nm LIDT was comparatively less sensitive to oxygen flow, consistent with the wavelength-dependent roles of absorptive precursors and microstructural defects. In contrast, a HfO 2 -based high-reflector (HR) showed a higher LIDT at lower oxygen flow, indicating that the family of damage precursors changes between single layers and multilayers; in stacks, structural properties such as stress, gas entrapment and thermal dissipation may outweigh the isolated absorptive defects found in single layers. These results demonstrate that the optimal oxygen flow condition depends on both LIDT wavelength and film architecture. We identified, for single layers, a 15–35 sccm window for maximizing the 1064 nm LIDT and a high-flow optimum (45 sccm) for the 355 nm LIDT and, for 355 nm HR stacks, a distinct lower-flow regime (~10 sccm).

Optics and optical instruments↗

Reduction of Radiographic Spot Size with Dual Diameter Sub-mm Rods

Among the most dominant factors in x-ray radiographic image resolution is the radiographic spot size, which is primarily a function of the physical extent of the x-ray source, so the most marked improvements in image resolution come from modifying the pulse power driver’s diode configuration to reduce that extent. The smaller the size of the x-ray spot, the higher the image resolution potential. The U.S. Naval Research Laboratory’s Mercury pulsed power accelerator has been configured with a rod-pinch diode, and recent measurements were conducted to demonstrate the impact of anode rod geometry on x-ray spot size. The “standard” anode rod is a 0.75 mm diameter cylinder that is tapered down to 0.25 mm over a length of 5 mm, and, in this study, it was replaced by rods with a sharp step between their two diameters, rather than a taper. The effect on spot size was assessed by analyzing the edge and line spread functions calculated from high-mag rolled edge and pinhole camera images. For certain diameter pairs, a reduction in radiographic spot size is observed. In addition, the dual-diameter rods have provided unique insight into the electron-anode coupling dynamics that are at play in all diodes of this type.

X-ray radiography, spot size↗