Search NASA⌕ Search

SEARCH · Search NASA

Results for “plug device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Catalytic Microtube Rocket Igniter

Devices that generate both high energy and high temperature are required to ignite reliably the propellant mixtures in combustion chambers like those present in rockets and other combustion systems. This catalytic microtube rocket igniter generates these conditions with a small, catalysis-based torch. While traditional spark plug systems can require anywhere from 50 W to multiple kW of power in different applications, this system has demonstrated ignition at less than 25 W. Reactants are fed to the igniter from the same tanks that feed the reactants to the rest of the rocket or combustion system. While this specific igniter was originally designed for liquid methane and liquid oxygen rockets, it can be easily operated with gaseous propellants or modified for hydrogen use in commercial combustion devices. For the present cryogenic propellant rocket case, the main propellant tanks liquid oxygen and liquid methane, respectively are regulated and split into different systems for the individual stages of the rocket and igniter. As the catalyst requires a gas phase for reaction, either the stored boil-off of the tanks can be used directly or one stream each of fuel and oxidizer can go through a heat exchanger/vaporizer that turns the liquid propellants into a gaseous form. For commercial applications, where the reactants are stored as gases, the system is simplified. The resulting gas-phase streams of fuel and oxidizer are then further divided for the individual components of the igniter. One stream each of the fuel and oxidizer is introduced to a mixing bottle/apparatus where they are mixed to a fuel-rich composition with an O/F mass-based mixture ratio of under 1.0. This premixed flow then feeds into the catalytic microtube device. The total flow is on the order of 0.01 g/s. The microtube device is composed of a pair of sub-millimeter diameter platinum tubes connected only at the outlet so that the two outlet flows are parallel to each other. The tubes are each approximately 10 cm long and are heated via direct electric resistive heating. This heating brings the gasses to their minimum required ignition temperature, which is lower than the auto-thermal ignition temperature, and causes the onset of both surface and gas phase ignition producing hot temperatures and a highly reacting flame. The combustion products from the catalytic tubes, which are below the melting point of platinum, are injected into the center of another combustion stage, called the primary augmenter. The reactants for this combustion stage come from the same source but the flows of non-premixed methane and oxygen gas are split off to a secondary mixing apparatus and can be mixed in a near-stoichiometric to highly lean mixture ratio. The primary augmenter is a component that has channels venting this mixed gas to impinge on each other in the center of the augmenter, perpendicular to the flow from the catalyst. The total crosssectional area of these channels is on a similar order as that of the catalyst. The augmenter has internal channels that act as a manifold to distribute equally the gas to the inward-venting channels. This stage creates a stable flame kernel as its flows, which are on the order of 0.01 g/s, are ignited by the combustion products of the catalyst. This stage is designed to produce combustion products in the flame kernel that exceed the autothermal ignition temperature of oxygen and methane.

Schneider, Steven J.↗

Free jet feasibility study of a thermal acoustic shield concept for AST/VCE application: Single stream nozzles

A technology base for the thermal acoustic shield concept as a noise suppression device for single stream exhaust nozzles was developed. Acoustic data for 314 test points for 9 scale model nozzle configurations were obtained. Five of these configurations employed an unsuppressed annular plug core jet and the remaining four nozzles employed a 32 chute suppressor core nozzle. Influence of simulated flight and selected geometric and aerodynamic flow variables on the acoustic behavior of the thermal acoustic shield was determined. Laser velocimeter and aerodynamic measurements were employed to yield valuable diagnostic information regarding the flow field characteristics of these nozzles. An existing theoretical aeroacoustic prediction method was modified to predict the acoustic characteristics of partial thermal acoustic shields.

Majjigi, R. K.↗

Rapidly Deployable Acoustic Monitoring and Localization System Based on a Low-Cost Wave Buoy Platform

The primary objective of this project is to develop a cost-effective, fit-for-purpose environmental monitoring system, “NoiseSpotter®,” that characterizes, classifies, and provides accurate location information for anthropogenic and natural sounds in near real-time. NoiseSpotter was developed to support the evaluation of potential acoustic effects of marine energy (ME) projects. By utilizing a compact array of three acoustic particle motion sensors, NoiseSpotter triangulates individual bearings to provide sound source localization to within 5% accuracy, allowing the ability to discern ME device sounds relative to other confounding sounds in the environment, while providing location estimates to nearby marine mammals for environmental mitigation purposes. The ME industry needs proven solutions to meet environmental impact assessment needs. The NoiseSpotter® includes off-the-shelf, modular components that are easy to assemble and disassemble. Its acoustic particle motion sensors are commercially available and the data logger and real-time telemetry system is designed to be plug-and-play. The entire system is relatively compact and can be deployed from small vessels. NoiseSpotter’s near real-time capability enables operational monitoring of ME sounds, particularly during early stages of technology adoption to facilitate mitigation of potential noise effects. Widespread adoption of the technology for acoustic monitoring of ME devices requires that it be cost effective; hence the anticipated commercial cost of system hardware is $35,000. This project contributes to reducing barriers to ME testing through support of scientific research focused on reducing or mitigating environmental risks and lowering costs and complexity of environmental monitoring. This project has developed an acoustic monitoring system, NoiseSpotter® (U.S. Patent No. 11,156,734 and U.S. Registered Trademark No. 6,442,313), to detect and characterize baseline noise and sounds from ME operations and support geolocation of detected sounds. The intended outcome of the project is to mitigate concerns about the potential for ME device noise to alter marine mammal or fish behavior. NoiseSpotter® enables cost-effective, near real-time acoustic monitoring of an operational ME device relative to ambient environmental noise and provides a technical basis for ME developers seeking to navigate the permitting process in an efficient manner.

16 TIDAL AND WAVE POWER↗

Extendible probe for atmosphere sampling

Sampling probe is extended through small plug in heat shield by loaded bellows to sample planetary atmosphere for compositional analysis and total pressure during entry of space probe. Assembly prevents contamination of sample by gases from pyrotechnic device and serves as sealed plenum for atmospheric pressure sensor.

Jones, W. J.↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗

Pressure Reducer for Coal Gasifiers

Quasi-porous-plug pressure reducer is designed for gases containing abrasive particles. Gas used to generate high pressure steam to drive electric power generators. In giving up heat to steam, gas drops in temperature. Device used for coal gasification plants.

Kendall, James M., Sr.↗

Engineered current-density profile diode laser

The present technology can be used to control the current injection profile in the longitudinal direction of a high-power diode laser in order to optimize current densities as a function of position in the cavity to promote higher reliable output power and increase the electrical to optical conversion efficiency of the device beyond the level which can be achieved without application of this technique. This approach can be utilized, e.g., in the fabrication of semiconductor laser chips to improve the output power and wall plug efficiency for applications requiring improved performance operation.

Leisher, Paul O.↗

Engineered current-density profile diode laser

The present technology can be used to control the current injection profile in the longitudinal direction of a high-power diode laser in order to optimize current densities as a function of position in the cavity to promote higher reliable output power and increase the electrical to optical conversion efficiency of the device beyond the level which can be achieved without application of this technique. This approach can be utilized, e.g., in the fabrication of semiconductor laser chips to improve the output power and wall plug efficiency for applications requiring improved performance operation.

Leisher, Paul O.↗

Plug-in Plan Tool v3.0.3.1

The role of PLUTO (Plug-in Port UTilization Officer) and the growth of the International Space Station (ISS) have exceeded the capabilities of the current tool PiP (Plug-in Plan). Its users (crew and flight controllers) have expressed an interest in a new, easy-to-use tool with a higher level of interactivity and functionality that is not bound by the limitations of Excel. The PiP Tool assists crewmembers and ground controllers in making real-time decisions concerning the safety and compatibility of hardware plugged into the UOPs (Utility Outlet Panels) onboard the ISS. The PiP Tool also provides a reference to the current configuration of the hardware plugged in to the UOPs, and enables the PLUTO and crew to test Plug-in locations for constraint violations (such as cable connector mismatches or amp limit violations), to see the amps and volts for an end item, to see whether or not the end item uses 1553 data, and the cable length between the outlet and the end item. As new equipment is flown or returned, the database can be updated appropriately as needed. The current tool is a macroheavy Excel spreadsheet with its own database and reporting functionality. The new tool captures the capabilities of the original tool, ports them to new software, defines a new dataset, and compensates for ever-growing unique constraints associated with the Plug-in Plan. New constraints were designed into the tool, and updates to existing constraints were added to provide more flexibility and customizability. In addition, there is an option to associate a "Flag" with each device that will let the user know there is a unique constraint associated with it when they use it. This helps improve the safety and efficiency of real-time calls by limiting the amount of "corporate knowledge" overhead that has to be trained and learned through use. The tool helps save time by automating previous manual processes, such as calculating connector types and deciding which cables are required and in what order.

Andrea-Liner, Kathleen E.↗

Engineering of Data Acquiring Mobile Software and Sustainable End-User Applications

The criteria for which data acquiring software and its supporting infrastructure should be designed should take the following two points into account: the reusability and organization of stored online and remote data and content, and an assessment on whether abandoning a platform optimized design in favor for a multi-platform solution significantly reduces the performance of an end-user application. Furthermore, in-house applications that control or process instrument acquired data for end-users should be designed with a communication and control interface such that the application's modules can be reused as plug-in modular components in greater software systems. The application of the above mentioned is applied using two loosely related projects: a mobile application, and a website containing live and simulated data. For the intelligent devices mobile application AIDM, the end-user interface have a platform and data type optimized design, while the database and back-end applications store this information in an organized manner and manage access to that data to only to authorized user end application(s). Finally, the content for the website was derived from a database such that the content can be included and uniform to all applications accessing the content. With these projects being ongoing, I have concluded from my research that the applicable methods presented are feasible for both projects, and that a multi-platform design for the mobile application only marginally drop the performance of the mobile application.

Smith, Benton T.↗

CO2 hydrate crystal thickening, morphology, and Raman spectroscopy in a microfluidic device

Gas hydrates are a solid, crystalline form of water that often form at low temperatures and high pressures. Carbon dioxide (CO2) hydrates may form during carbon dioxide capture and storage (CCS) processes. These solid compounds may form in CO2 pipelines, potentially leading to a full blockage and process shutdown for plug removal. On the other hand, formation of CO2 hydrates may be desired for CO2 capture and separation. In either case, understanding the growth behavior and nature of the hydrates is vital to managing these CCS processes. Using a high-pressure, transparent microfluidic reactor, the crystalline film thickening of CO2 hydrates was observed and measured through visual microscopy and Raman spectroscopy. The impact of subcooling, pressure, and CO2 flow rate was investigated, and only CO2 flow rate was found to have a significant impact on the overall thickness of the film. Visual observations and Raman spectroscopy measurements confirmed that two distinct hydrate layers formed during thickening, one which was more porous than the other. The capillary-like channels in the porous layer indicated a mechanism for mass transfer of water through the hydrate layer. A model was developed based on this observation, and it was fit to the thickening data in order to obtain mass transfer coefficients. Results of this study can be applied to CO2 hydrate formation in pipelines and near porous media used for CO2 capture.

Wadsworth, Lindsey [Colorado School of Mines, Gold↗

Sustained arc ignition system

Circuitry for maintaining an arc or spark across a spark gap for a desired length of time is disclosed. A high voltage, direct current source is connected in series with a secondary winding of a high voltage, stepup transformer or coil and a spark gap such as a spark plug for example. The high voltage source may be on continuously or may be turned on and off by a control circuit such as a solid state switch which is, in turn, responsive to a timing device such as a set of ignition contact points or a magnetic pulse generator operating in synchronism with a spark ignition engine. The timing device also provides signals to a current switching circuit which interrupts, current flow through a primary winding of the high voltage coil at the prescribed time that a spark is desired at the spark gap.

Birchenough, A. G.↗

Phase Separators And Fountain-Effect Pumps For He 11

Fused-glass microchannel arrays for use as HE 11 phase separators and fountain-effect pumps. Microchannel devices for use in low-gravity storage and cooling systems containing superfluid helium. Phase separators and pumps take advantage of thermomechanical effect peculiar to He 11 in restricted spaces. By creating thermal gradient in porous plug, direction of flow reversed, turning phase separator into pump. However, addition of heat disadvantage. Thermal gradient created by using Peltier effect to transfer heat across array, removing heat from He 11 supply and overcoming undesirable addition of heat.

Whitehouse, Paul L.↗

Control approach for power modulation of end-use loads

Methods, apparatus, and systems are disclosed herein for power modulation control of power grids using end-use loads. At the beginning of a coordination period typically lasting a few minutes, a population of end-use loads (water heaters, air conditioners, plug-in electric vehicles, etc.) is interrogated for their willingness to participate in power modulation by undergoing state transitions from on to off, or off to on. Distribution system flexibilities are calculated from the sums of device powers within distribution systems. Area flexibilities are calculated from the sums of device powers within areas. Thresholds for various devices to change state in response to inter-area oscillation damping or frequency regulation are derived from these flexibilities. Two power functions are monitored in real-time and compared with the device thresholds to trigger state changes which then remain locked throughout the remainder of the coordination period, then the devices are released from the lockout state.

Lian, Jianming↗

Microscale device and method for purification of radiopharmaceuticals

A microfluidic chip device for the purification of radiochemical compounds includes a chip having an injection channel and intersecting branch channels with a plurality of valves are located along the injection channel and branch channels and configured to retain a plug of solution containing the radiochemical compound. The chip further includes a serpentine channel segment (for separation) coupled to the output of the injection channel. A high voltage power source advances the plug of solution through the purification region and into the downstream fraction collection channel. The chip includes a downstream fraction collection channel coupled to the serpentine channel segment and having an optical and radiation detection regions. One or more branch fraction channels intersect with the fraction collection channel and include valves located therein so that the radiochemical compound that is detected using a radiation detector is directed into the desired branch fraction channel for subsequent use.

Van Dam, R. Michael↗

Accidental Disassembly of a Multi Branch Outlet Strip with Surge Protector (Investigation Report)

On December 16 a worker attempted to disconnect a computer plug from a multi outlet surge protector strip. The plastic housing of the surge protector disintegrated while the plug was pulled exposing the bare conductors of the internal wiring. The worker disconnected the wall plug on the multi outlet strip and de-energized the outlet strip. The worker contacted the FOD and the FOD called the ISR DESO for advice. The DESO collected the pieces and performed an autopsy on the device.

42 ENGINEERING↗

RF Manipulation of Ions in the High Performance Antiproton Trap (HiPAT)

The annihilation of antimatter provides the highest mass specific energy of any other known reaction. Proper harnessing of this energy holds great promise for future space propulsion systems. Many different propulsion concepts have been proposed that take advantage of antimatter, either using matter-antimatter as the primary fuel, or as a 'spark plug' for fusion and fission systems. In order to begin to address these concepts experimentally, a method of storing and transporting antimatter must be developed. The High Performance Antiproton Trap (HiPAT) is a first-generation storage and transportation device designed to store and transport 10(exp 12) antiprotons with a storage half-life of 18 days. It uses a Penning-Malmberg ion trap with a 4T magnetic field and 20 kV potential. This will enable researchers much more flexibility in the design of antimatter experiments related to propulsion. Ions cannot be stored indefinitely in a real trap, as ion cloud instabilities develop from imperfections in manufacturing and misalignments in assembly. Previous work has been done at both the National Institute of Standards and University of California in San Diego in using RF (radio frequency) signals to both diagnose and confine the ion cloud. Two electrodes in the trap have been segmented to allow both reception and transmission of RF waves in the ion cloud. Experiments are underway to determine the number of ions and density in the cloud by "listening" to protons contained in the HiPAT. Currently we believe the density of ions stored in the trap is roughly 10(exp 15) m(exp -3). Development of non-destructive techniques is vital to the project goals, enabling continuous monitoring of the quantities stored in the system. Experimental work is also being done in identifying RF transmission frequencies that can manipulate the density of the cloud, by exchanging energy and momentum between the RF wave and the ions. Preliminary experiments have demonstrated this interaction.

Pearson, J. Boise↗

Demonstration of multi-active region p-down green LEDs with high quantum efficiency

Abstract Longer wavelength emitters such as green LEDs display a pronounced efficiency drop at higher current densities, resulting in relatively low wall-plug efficiency (WPE). Multi-active region approach can improve the WPE significantly and tackle the “green gap” challenge. This work reports multi-active region p-down LEDs with high external efficiency operating entirely in the green wavelength. Devices were developed using p-down topology, where the PN junction is oriented such that electric fields from depletion and built-in polarization dipoles are aligned. Ga-polar multi-active region green LEDs with excellent voltage and external quantum efficiency scaling, and significantly higher WPE is demonstrated in this work.

Physics↗