Search NASA⌕ Search

SEARCH · Search NASA

Results for “polarization rotation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Rotational coherence dominates early-time dynamics and produces long-time revivals in the S 2 state of azulene

Here, the ultrafast dynamics of azulene have been debated for decades, with reported picosecond decay constants variously attributed to intramolecular vibrational redistribution (IVR), internal conversion, or rotational dephasing. Using polarization- and femtosecond time-resolved resonance-enhanced multiphoton ionization spectroscopy with a nanosecond delay window, we disentangle this long-standing inconsistency and show that the early 2–5 ps decay component arises entirely from the rotational dephasing of an excited-state wavepacket. Identical time constants extracted from the decay of the parallel signal and the rise of the perpendicular signal across multiple vibronic origins provide an unambiguous rotational anisotropy signature, eliminating the need for IVR-based interpretations. Extending the measurement window to 1.3 ns reveals well-structured J-type and C-type rotational coherence revivals in S 2 azulene on top of the well-documented fluorescence decay, demonstrating that both the short- and long-time dynamics contain information about the coherent rotational dynamics. These results show that azulene, and by extension polycyclic aromatic hydrocarbons, can sustain structured rotational coherence deep into the nanosecond regime, positioning PAHs as model systems for quantum-coherent wavepacket dynamics and providing a framework for probing coherence, decoherence, and rotational control in electronically rich molecular systems.

Zhan, Jie [University of Georgia, Athens, GA (Unit↗

Enhanced ionization of counter-rotating electrons via doorway states in ultrashort circularly polarized laser pulses

We have performed single-active-electron numerical calculations of neon- and argonlike atoms interacting with short, intense, circularly polarized laser pulses at wavelengths between 10 nm and 1000 nm. Our results reveal a surprisingly large change by a factor of about 100 in the ionization ratio of electrons in initial states counter-rotating with respect to the field over corotating electrons in the previously unexplored intermediate few-photon ionization regime. The physical mechanism behind this observation is related to resonant enhanced ionization via states close in energy to the initial states. These doorway states are accessible exclusively from the initial state for counter-rotating electrons within the respective wavelength regime. Furthermore, the results may open a new route for controlling the generation of spin-polarized electrons by ultrashort laser pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗

Unexpected symmetry breaking in ferroelectric wurtzite thin films on silicon observed by optical second harmonic generation

Optical second harmonic generation (SHG) exists as a popular tool for probing materials with broken inversion symmetry in the physical and biological sciences. SHG polarimetry can reveal material anisotropy with high sensitivity, including point group and phase transitions. Here, we probe ferroelectric wurtzite films with a nominal 6 mm symmetry under a normal reflection geometry using SHG microscopy and discover an unexpected symmetry breaking. Symmetry considerations would normally forbid the detection of the SHG signal when light propagates along the polar 6-fold rotation axis. Yet a uniquely anisotropic SHG response is observed in this geometry in Al 1-x B x N, Al 1-x Sc x N, Zn 1-x Mg x O, and AlN/Al 1-x Sc x N heterostructures grown on silicon that can be modeled by an average monoclinic symmetry of point group m. A significant enhancement of the SHG signal corresponding to up to a 5.3× increase in the SHG intensity (hence ∼2.3 × in effective SHG tensor coefficient) is observed at antiparallel polar domain walls, suggesting local cooperative alignment of symmetry-breaking structural distortions. Namely, it is found that the monoclinic mirror plane is oriented predominantly perpendicular to the walls. Such increases in domain wall SHG thus reveal that subtle symmetry breaking can be a pathway to large property enhancements.

36 MATERIALS SCIENCE↗

Understanding and Manipulating Helical Nanofilaments in Binary Systems with Achiral Dopants

Here, in this paper, we report the relationship between helical pitch of the helical nanofilament (HNF) phase formed by bent-core molecule NOBOW and the concentration of achiral dopants 5CB and octane, using linearly polarized resonant soft X-ray scattering (RSoXS). Utilizing theory-based simulation, which fits well with the experiments, the molecular helices in the filament were probed and the superstructure of helical 5CB directed by groove of HNFs was observed. Quantitative pitch determination with RSoXS reveals that helical pitch variation is related to 5CB concentration with no temperature dependence. Doping rodlike immiscible 5CB led to a pitch shortening of up to 30%, which was attributed to a change in interfacial tension. By shedding light not only on phase behavior of binary systems but also enabling control over pitch length, our work may benefit various applications of HNF-containing binary systems, including optical rotation devices, circularly polarized light emitters, and chirality transfer agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Corrosion-Resistant Non-Carbon Electrocatalyst Supports for PEFCS

Insufficient durability of commercial catalysts is a persistent issue for PEFC applications.1 Herein, Pt on Nb-doped-TiO 2 is reported as a highly durable electrocatalyst on which the direct 4-electron reduction of oxygen to water is more facile compared to Pt/C. All performance metrics are reported comparing Pt/Nb-TiO2 with a 15% Pt loading, against a commercial Pt/C catalyst (46.5% Pt loading, Tanaka, K. K.). Nb-doped-TiO 2 with high surface area and high electronic conductivity was synthesized using the supercritical fluid method. Initially, the durability of the catalyst was characterized using accelerated stability tests (ASTs) involving 10,000 high potential cycles (DOE/FCCJ protocol) and the Pt/Nb-TiO 2 was found to retain 78% of its initial electrochemically active surface area (ECSA) compared to the 57.6 % retained by Pt/C. These observations were in excellent agreement with previous reports that the Pt particle size of Pt/C grew from 2nm to 8nm during the AST protocol along with severe corrosion and amorphization of the carbon surface.2, 3 TEM and XPS studies of the Pt-Nb-doped-TiO 2 catalyst showed that the Pt particle size grew from 3nm to 6nm and the Nb(IV) and Ti(III) in the support were oxidized to Nb(V) and Ti(IV) after the durability test. Thus, the improvement in Pt/Nb-TiO 2 ECSA retention was attributed to the lower extent of particle growth and lack of oxidative support loss upon oxidation as compared to Pt/C. The oxygen reduction reaction (ORR) performance was characterized by linear polarization using a rotating disk electrode (RDE). The electrochemical surface areas of Pt/Nb-TiO 2 and Pt/C were found to be 48m2·g -1 and 83m2·g -1 respectively, and the mass activity for the ORR at 0.9V vs. RHE were found to be 150 mA·mg-1Pt and 124 mA·mg-1Pt respectively. The improved mass activity on Pt/Nb-TiO 2 was attributed to strong metal support interaction (SMSI) between the Nb-TiO 2 support and the Pt catalyst based on the 625 meV decrease in the binding energy of the Pt4f x-ray photo-electron spectroscopy (XPS) peaks of Pt/Nb-TiO 2 compared to Pt/C. To quantify the impact of the SMSI, a kinetic model was applied to calculate the elementary reaction rate constants for the various steps of the ORR on both catalysts. The reaction rate constant (k1) for the direct 4-electron transfer pathway to produce H 2 O was significantly larger in Pt/Nb-TiO 2 as compared to Pt/C. Thus, the reduction in the electron binding energy as observed in the XPS was found to aid the facile filling of the higher energy 2p orbitals of O 2 thereby leading to improved 4-electron transfer kinetics and improved overall activity.

08 HYDROGEN↗

The Influence of Structural Dynamics in Two-Dimensional Hybrid Organic–Inorganic Perovskites on Their Photoluminescence Efficiency — Neutron Scattering Analysis

Two-dimensional hybrid organic–inorganic perovskites (HOIPs) have emerged as promising materials for light-emitting diode applications. In this study, by using time-of-flight neutron spectroscopy we identified and quantitatively separated the lattice vibrational and molecular rotational dynamics of two perovskites, butylammonium lead iodide (BA)2PbI4 and phenethyl-ammonium lead iodide (PEA) 2 PbI 4 . By examining the corresponding temperature dependence, we found that the lattice vibrations, as evidenced by neutron spectra, are consistent with the lattice dynamics obtained from Raman scattering. We revealed that the rotational dynamics of organic molecules in these materials tend to suppress their photoluminescence quantum yield (PLQY) while the vibrational dynamics did not show predominant correlations with the same. Additionally, we observed photoluminescence emission peak splitting for both systems, which becomes prominent above certain critical temperatures where the suppression of PLQY begins. This study suggests that the rotational motions of polarized molecules may lead to a reduction in exciton binding energy or the breaking of degeneracy in exciton binding energy levels, enhancing non-radiative recombination rates, and consequently reducing photoluminescence yield. These findings offer a deeper understanding of fundamental interactions in 2D HOIPs and could guide the design of more efficient light-emitting materials for advanced technological applications.

Rajeev, Haritha Sindhu [Univ. of Virginia, Charlot↗

The storage ring proton EDM experiment

We describe a proposal to search for an intrinsic electric dipole moment (EDM) of the proton with a sensitivity of \targetsens, based on the vertical rotation of the polarization of a stored proton beam. The New Physics reach is of order $10^~3$TeV mass scale. Observation of the proton EDM provides the best probe of CP-violation in the Higgs sector, at a level of sensitivity that may be inaccessible to electron-EDM experiments. The improvement in the sensitivity to $\theta_{QCD}$, a parameter crucial in axion and axion dark matter physics, is about three orders of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hydrodynamic spin-orbit coupling in asynchronous optically driven micro-rotors

Abstract Vortical flows of rotating particles describe interactions ranging from molecular machines to atmospheric dynamics. Yet to date, direct observation of the hydrodynamic coupling between artificial micro-rotors has been restricted by the details of the chosen drive, either through synchronization (using external magnetic fields) or confinement (using optical tweezers). Here we present a new active system that illuminates the interplay of rotation and translation in free rotors. We develop a non-tweezing circularly polarized beam that simultaneously rotates hundreds of silica-coated birefringent colloids. The particles rotate asynchronously in the optical torque field while freely diffusing in the plane. We observe that neighboring particles orbit each other with an angular velocity that depends on their spins. We derive an analytical model in the Stokes limit for pairs of spheres that quantitatively explains the observed dynamics. We then find that the geometrical nature of the low Reynolds fluid flow results in a universal hydrodynamic spin-orbit coupling. Our findings are of significance for the understanding and development of far-from-equilibrium materials.

47 OTHER INSTRUMENTATION↗

Wastewater Disposal Has Not Significantly Altered the Regional Stress State in Southern Kansas

Wastewater disposal is primarily responsible for the increased seismicity rate since ~2013 in southern Kansas. Previous work that used shear-wave splitting (SWS) in southern Kansas interpreted an ~90° temporal rotation in the fast polarization direction and attributed it to increased pore pressures resulting from fluid injection. However, this interpreted rotation coincided with a change in the stations used to make the SWS measurements. We investigate the temporal variability of fast azimuths in southern Kansas by making SWS measurements on earthquake families with similar source–receiver paths recorded on a stable local seismic network. We select high-quality SWS measurements by investigating the stability of results across 65 different frequency bands between 0.5 and 15 Hz. We find that the fast polarization direction in southern Kansas is relatively constant with an average east-northeast (~N79°E) orientation between 2014 and 2017. Our fast polarization measurements are primarily a reflection of the maximum principal horizontal stress direction (SHmax). We observe a slight spatial change in SHmax to the northeast (~N55°E) near the Nemaha ridge in Oklahoma. However, we do not observe any significant temporal rotation of SHmax or variation in delay time (i.e., crack density) in southern Kansas, contrary to the earlier study. The previously interpreted ~90° rotation may either be a reflection of a very local stress change or a misinterpretation of SWS results potentially due to the use of inconsistent source–receiver paths. Our SWS measurements cover the period of peak wastewater disposal and seismicity rates and suggest an absence of significant temporal rotations in the local anisotropy and stress orientations associated with wastewater disposal.

Geochemistry & Geophysics↗

EIC'S HSR Rotator and Snake Configuration at IP6

The Electron-Ion Collider’s Hadron Storage Ring (HSR) will use a pair of spin rotators to achieve longitudinal polarization at IP6. Additionally there are to be six snakes located at azimuthal angles of 60 degrees from each other. Due to space constraints in the whole lattice, in order to achieve a 60 degree separation between the snakes, we are forced to place a snake near IP6 where the rotator normally would be. We explore if a powering scheme exists which would recover a longitudinal polarization at IP6 and the same spin rotation of a normal orthogonal snake at collision energies.

43 PARTICLE ACCELERATORS↗

Complete Stokes vector analysis with a compact, portable rotating waveplate polarimeter

Accurate calibration of polarization dependent optical elements is often necessary in optical experiments. A versatile polarimeter device to measure the polarization state of light is a valuable tool in these experiments. Here we report a rotating waveplate-based polarimeter capable of complete Stokes vector analysis of collimated light. Calibration of the device allows accurate measurements over a range of wavelengths, with a bandwidth of >30 nm in this implementation. A photo-interrupter trigger system supplies the phase information necessary for full determination of the Stokes vector. An Arduino microcontroller performs rapid analysis and displays the results on a liquid crystal display. The polarimeter is compact and can be placed anywhere on an optical table on a single standard post. The components to construct the device are only a fraction of the cost of commercially available devices while the accuracy and precision of the measurements are of the same order of magnitude.

47 OTHER INSTRUMENTATION↗

Selection of Target Thickness and Size of Drive Electron Beam for Ce+BAF Injector

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This concept is based on the generation of CW longitudinally polarized positrons by a high-current, polarized electron beam (1 mA, 130-370 MeV, and 90% longitudinal polarization) that passes through a rotating, water-cooled, tungsten target. The positron yield and longitudinal polarization are calculated for the 123 MeV Ce+BAF injector at the Low Energy Recirculator Facility (LERF). The longitudinal and transverse CEBAF acceptances, defined as an energy spread of less than 1% and a normalized emittance of less than 100 mm·mrad, have been used in these calculations. The impact of target thickness, transverse electron beam size, and electron beam energy on the yield and polarization of a positron injector is evaluated. The total energy deposited by the beams in the tungsten target and the peak energy density are calculated for different target thicknesses, electron beam sizes, and energies.

Ushakov, Andriy [Thomas Jefferson National Acceler↗

A Search for Polarized Thermal Emission from Directly Imaged Exoplanets and Brown Dwarf Companions to Nearby Stars

Aerosols in the atmospheres of cloudy gas giant exoplanets and brown dwarfs scatter and polarize these objects’ thermal emission. If such an object has an oblate shape or nonuniform cloud distribution, the net degree of linear polarization can show an increase ranging from several tenths of a percent to a few percent. Modern high-contrast imaging polarimeters are now poised to detect such low-polarization signals, opening up a new window into the rotational velocities and cloud properties of substellar companions to nearby stars. In this paper, we present the results of a near-IR survey searching for linearly polarized thermal emission from a sample of two planetary-mass companions and five brown dwarf companions using GPI and SPHERE-IRDIS. We probe the subpercent linear polarization regime that typifies polarized free-floating brown dwarfs and place limits on each object’s degree of linear polarization. We relate our upper limits on each target’s degree of linear polarization to its rotation rate, and place our results in the context of rotation rates measured using high-resolution spectroscopy.

79 ASTRONOMY AND ASTROPHYSICS↗

Octahedral rotations in Ruddlesden-Popper layered oxides under pressure from first principles

The combination of reduced dimensionality and tunable structural distortions in layered perovskite oxides makes these materials ideal platforms for designing novel properties and functionalities. One example is hybrid improper ferroelectricity in n = 2 Ruddlesden-Popper oxides, where the combination of a layered crystal structure and rotations of the metal-oxide octahedra break symmetry and induce a polarization. Precisely controlling the octahedral rotation distortions, for example by the application of hydrostatic pressure, provides a pathway to tune and optimize the properties of these materials. Here we combine group theoretic methods, density functional theory calculations, and Landau theory analysis to investigate how octahedral rotations respond to pressure in the hybrid improper ferroelectrics Sr 3 Zr 2 O 7 , Ca 3 Ti 2 O 7 , and Sr 3 Sn 2 O 7 . We find that factors that are known to control the pressure response of ABO 3 perovskites—the formal charge of the A- and B-site cations, tolerance factor, and B-site chemistry—also impact the pressure response of these layered perovskites. We also show that coupling between the octahedral rotation and strain order parameters plays a key role in determining the overall pressure response. Despite some similarities, we find that these layered perovskites display a distinct pressure response compared to their ABO 3 perovskite analogs. By identifying trends and underlying mechanisms that control octahedral rotations in Ruddlesden-Popper oxides under pressure, this work lays the foundation for tailoring the structure and properties of these materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A 2D chiral microcavity based on apparent circular dichroism

Abstract Engineering asymmetric transmission between left-handed and right-handed circularly polarized light in planar Fabry–Pérot (FP) microcavities would enable a variety of chiral light-matter phenomena, with applications in spintronics, polaritonics, and chiral lasing. Such symmetry breaking, however, generally requires Faraday rotators or nanofabricated polarization-preserving mirrors. We present a simple solution requiring no nanofabrication to induce asymmetric transmission in FP microcavities, preserving low mode volumes by embedding organic thin films exhibiting apparent circular dichroism (ACD); an optical phenomenon based on 2D chirality. Importantly, ACD interactions are opposite for counter-propagating light. Consequently, we demonstrated asymmetric transmission of cavity modes over an order of magnitude larger than that of the isolated thin film. Through circular dichroism spectroscopy, Mueller matrix ellipsometry, and simulation using theoretical scattering matrix methods, we characterize the spatial, spectral, and angular chiroptical responses of this 2D chiral microcavity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗