Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A fifty channel electrically scanned pressure module

A unique miniature pressure sensor system consisting of an array of fifty integrated sensor pressure transducers with integral electronic logic and switching is described. Solid state processing of the piezoresistive array is combined with hybrid microelectronics to produce a very small, dense (80 cc displacement), high reliability pressure measuring system. Application to high speed data acquisition, energy conservation in wind tunnels and flight test is discussed. Test data are presented typifying system performance.

Mallon, J. R.↗

Thermally Stable, Piezoelectric and Pyroelectric Polymeric Substrates

A thermally stable, piezoelectric and pyroelectric polymeric substrate was prepared. This thermally stable, piezoelectric and pyroelectric polymeric substrate may be used to prepare electromechanical transducers, thermomechanical transducers, accelerometers. acoustic sensors, infrared sensors, pressure sensors, vibration sensors, impact sensors, in-situ temperature sensors, in-situ stress/strain sensors, micro actuators, switches, adjustable fresnel lenses, speakers, tactile sensors. weather sensors, micro positioners, ultrasonic devices, power generators, tunable reflectors, microphones, and hydrophones. The process for preparing these polymeric substrates includes: providing a polymeric substrate having a softening temperature greater than 1000 C; depositing a metal electrode material onto the polymer film; attaching a plurality of electrical leads to the metal electrode coated polymeric substrate; heating the metal electrode coated polymeric substrate in a low dielectric medium; applying a voltage to the heated metal electrode coated polymeric substrate to induce polarization; and cooling the polarized metal electrode coated polymeric electrode while maintaining a constant voltage.

Simpson, Joycely O.↗

Method of Making Thermally Stable, Piezoelectric and Proelectric Polymeric Substrates

A thermally stable, piezoelectric and pyroelectric polymeric substrate was prepared. This thermally stable, piezoelectric and pyroelectric polymeric substrate may be used to prepare electromechanical transducers, thermomechanical transducers, accelerometers, acoustic sensors, infrared sensors, pressure sensors, vibration sensors, impact sensors. in-situ temperature sensors, in-situ stress/strain sensors, micro actuators, switches, adjustable fresnel lenses, speakers, tactile sensors, weather sensors, micro positioners, ultrasonic devices, power generators, tunable reflectors, microphones, and hydrophones. The process for preparing these polymeric substrates includes: providing a polymeric substrate having a softening temperature greater than 100 C; depositing a metal electrode material onto the polymer film; attaching a plurality of electrical leads to the metal electrode coated polymeric substrate; heating the metal electrode coated polymeric substrate in a low dielectric medium: applying a voltage to the heated metal electrode coated polymeric substrate to induce polarization; and cooling the polarized metal electrode coated polymeric electrode while maintaining a constant voltage.

Simpson, Joycelyn O.↗

Thermally Stable, Piezoelectric and Pyroelectric Polymeric Substrates and Method Relating Thereto

A thermally stable, piezoelectric and pyroelectric polymeric substrate was prepared, This thermally stable, piezoelectric and pyroelectric polymeric substrate may be used to prepare electromechanical transducers, thermomechanical transducers, accelerometers, acoustic sensors, infrared sensors, pressure sensors, vibration sensors, impact sensors. in-situ temperature sensors, in-situ stress/strain sensors, micro actuators, switches. adjustable fresnel lenses, speakers, tactile sensors, weather sensors, micro positioners, ultrasonic devices, power generators, tunable reflectors, microphones, and hydrophones. The process for preparing these polymeric substrates includes: providing a polymeric substrate having a softening temperature greater than 100 C; depositing a metal electrode material onto the polymer film; attaching a plurality of electrical leads to the metal electrode coated polymeric substrates; heating the metal electrode coated polymeric substrate in a low dielectric medium; applying a voltage to the heated metal electrode coated polymeric substrate to induce polarization; and cooling the polarized metal electrode coated polymeric electrode while maintaining a constant voltage.

Joycelyn O Simpson↗

Measuring Absolute Oxygen Pressure

Sensor determines absolute pressure of oxygen without reference pressure source. Absolute oxygen pressure transducer with control circuit enables measurement without reference pressure. Transducer, two part device, combines solid electrolyte membranes sensor with diffusional orifice. Device adapted for direct control of oxygen pressure in combustion mixtures.

Richter, R.↗

Overview of Dragonfly Entry Aerosciences Measurements (DrEAM)

NASA Ames Research Center (ARC) leads the Dragonfly Entry Aerosciences Measurements (DrEAM) project, which is an aeroshell instrumentation suite on the Dragonfly mission that fulfills the Engineering Science Investigation requirement for the New Frontiers mission. NASA ARC is partnering with NASA Langley Research Center (LaRC) and the German Aerospace Center (DLR) to provide a comprehensive sensor suite, including a DLR-provided Data Acquisition System (DAS). DrEAM will provide key aerothermodynamic data and performance analysis for Dragonfly’s forebody and backshell Thermal Protection System (TPS). Titan’s atmosphere predominantly consists of ni-trogen (~98% by mole) with small amounts of me-thane (~2% by mole) and other trace gases. CN is a strong radiator, and is found in nonequilibrium con-centrations for Titan entry. The accurate modeling of nonequilibrium CN radiation has proven to be a diffi-cult task. Prompted by the Huygens mission, many experimental campaigns and analyses were performed to better understand the aerothermal environments experienced by the probe during Titan entry [1]. How-ever, the Huygens probe carried no heatshield instru-mentation. Therefore, the DrEAM sensor suite will sig-nificantly advance the state-of-the-art not only by documenting the environment and performance of Dragonfly’s entry system but also by making key in situ measurements in Titan’s atmosphere for the first time. Aerothermal environments and TPS response will be measured using sensors whose flight heritage is tak-en from the Mars Entry, Descent, and Landing In-strumentation 2 (MEDLI2) thermocouple plugs and the COMbined Aerothermal and Radiometer Sensor (COMARS) suite [2], with the latter supplied by DLR. The MEDLI2 project used embedded thermocouples to directly measure the in-depth TPS temperature-time history at several locations on the heat shield and backshell of the Mars 2020 entry vehicle. These tem-perature measurements, in turn, can be used to infer surface environments via an inverse analysis proce-dure analogous to that used for MEDLI. For DrEAM, the thermocouple plug subsystem will be known as Dragonfly Sensors for Aero-Thermal Reconstruction (DragSTR). On Schiaparelli, the COMARS suite in-cluded three total surface-mounted heat flux sensors, three pressure sensors, and one radiometer. For DrEAM, the COMARS package will be known as the COmbined Sensor System for Titan Atmosphere (COSSTA). Since the methane concentration in the Titan atmos-phere is directly proportional to the radiative heat flux, the COSSTA measurements will be used to reduce the current uncertainty in the methane volume fraction. Atmospheric density measurements and capsule aero-dynamic data will be obtained through the onboard Inertial Measurement Unit (IMU), supplemented by pressure transducers similar to those used by the MEDLI and MEDLI2 projects. The DrEAM pressure sensors will be known as the Dragonfly Atmospheric Flight Transducers. (DrAFT). The pressure measure-ments, when combined with data from the on-board IMU, will allow for reconstruction of such quantities as vehicle Mach number, freestream density, and atmos-pheric winds. DrAFT measurements will enhance Dragonfly trajectory reconstruction and enable a sepa-ration of the aerodynamics from the atmosphere, as was done for MEDLI [3] and is currently in process for the MEDLI2 flight data set.

EDL↗

Overview of the Dragonfly Entry Aerosciences Measurements (DrEAM) Suite

NASA Ames and Langley arepartnering with DLR to propose acomprehensive instrumentation suite known as the Dragonfly Entry Aerosciences Meas-urements (DrEAM). DrEAM being the first competed mission to fly EDL instrumentation as part of NASA’s Engineering Science Investigation (ESI).DrEAM will provide key aerothermodynamicdata and performance analysisfor Dragonfly’s forebody and backshell therma lprotection system (TPS),and also includes a DLR-provided Data Acquisition System(DAS).Titan’s atmosphere predominantly consists of nitro-gen (~98% by mole) with small amounts of methane(~2% by mole)and other trace gases. CN is a strong ra-diator and is found in nonequilibriumconcentrationsfor Titan entry. The accurate modeling of nonequilibrium CN radiation has proven to be a difficult task. Prompted by the Huygensmission, many experimental campaigns and analyses were performed to better understand the aerothermal environments experience by the probe dur-ing Titan entry[1].However, the Huygens probe carried no heatshieldinstrumentation. Therefore,the DrEAM instrumentation suite will significantly advance the state-of-the-art not only by documenting theenviron-ment and performance of Dragonfly’sentry system but also by making keymeasurements in Titan’s atmos-phere for thefirst time, thus providing new benchmark dataapplicable to entry science more generally. Current Measurement Goals: Aerothermal envi-ronments and TPS responsewill be measured using sen-sors similarto the Mars Entry, Descent, and Landing In-strumentation2 (MEDLI2) Integrated Sensor Plug(MISP) and the COMbined Aerothermaland Radiome-ter Sensor (COMARS)suite[2], with the latter supplied by DLR.For MEDLI2, MISP usedembedded thermo-couples (TCs) todirectly measure in-depth temperature of theTPS at several locations,which can also be used to infer surface environmentsvia inverse analysis. For DrEAM, the MISPstyle plugswill be known as Drag-onfly Sensors for Aero-Thermal Reconstruction (Drag-STR)plugs. On Schiaparelli, the COMARSsuite in-cludedthree total surface-mounted heatflux sensors, three pressure sensors, and one radiometer. For DrEAM, the COMARS package will be known as COmbined Sensor System for Titan Atmosphere (COSSTA). Atmospheric density measurements and capsuleaerodynamic data will be obtained throughthe onboard Inertial Measurement Unit (IMU),supple-mented by pressure transducers similar tothose used by the MEDLI Mars Entry AtmosphericData System (MEADS).The DrEAM pressure sensors will be known as Dragonfly Atmospheric Flight Transducers(DrAFT) Both DragSTR and DrAFThave flight heritagefrom MISP and MEADS on the MSLand Mars 2020mis-sions, and the COMARS suite successfullyflew on the ESA Schiaparelli EDMlander. A preliminary layout of the sensors is shown in Fig. 1. Because Dragonflyuses the same aeroshell provider (i.e., LockheedMartin) and materials for the TPS,with what are expected to be sim-ilar thicknesses as MSL and Mars 2020on both the heat shield and backshell, theDrEAMinstrumentation will look to utilize the same techniques and processes as de-veloped byMEDLI and MEDLI2for vehicle integra-tion. This commonality alsoenables DrEAMto lever-age the extensiveground test qualifications performed forMEDLI and MEDLI2 and claim substantial heritagefor this system.

A Brandis↗

Systems and methods for measuring component matching

Systems and methods for measuring a contour match between adjacent components are disclosed. In one embodiment, at least two pressure sensors are located between adjacent components. Each pressure sensor is adapted to obtain a pressure measurement at a location a predetermined distance away from the other pressure sensors, and to output a pressure measurement for each sensor location. An output device is adapted to receive the pressure measurements from at least two pressure sensors and display the pressure measurements. In one aspect, the pressure sensors include flexible thin film pressure sensors. In accordance with other aspects of the invention, a method is provided for measuring a contour match between two interfacing components including measuring at least one pressure applied to at least one sensor between the interfacing components.

Courter, Kelly J.↗

Orion Flight Test-1 Thermal Protection System Instrumentation

The Orion Crew Exploration Vehicle (CEV) was originally under development to provide crew transport to the International Space Station after the retirement of the Space Shuttle, and to provide a means for the eventual return of astronauts to the Moon. With the current changes in the future direction of the United States human exploration programs, the focus of the Orion project has shifted to the project s first orbital flight test, designated Orion Flight Test 1 (OFT-1). The OFT-1 is currently planned for launch in July 2013 and will demonstrate the Orion vehicle s capability for performing missions in low Earth orbit (LEO), as well as extensibility beyond LEO for select, critical areas. Among the key flight test objectives are those related to validation of the re-entry aerodynamic and aerothermal environments, and the performance of the thermal protection system (TPS) when exposed to these environments. A specific flight test trajectory has been selected to provide a high energy entry beyond that which would be experienced during a typical low Earth orbit return, given the constraints imposed by the possible launch vehicles. This trajectory resulted from a trade study that considered the relative benefit of conflicting objectives from multiple subsystems, and sought to provide the maximum integrated benefit to the re-entry state-of-the-art. In particular, the trajectory was designed to provide: a significant, measureable radiative heat flux to the windward surface; data on boundary transition from laminar to turbulent flow; and data on catalytic heating overshoot on non-ablating TPS. In order to obtain the necessary flight test data during OFT-1, the vehicle will need to have an adequate quantity of instrumentation. A collection of instrumentation is being developed for integration in the OFT-1 TPS. In part, this instrumentation builds upon the work performed for the Mars Science Laboratory Entry, Descent and Landing Instrument (MEDLI) suite to instrument the OFT-1 ablative heat shield. The MEDLI integrated sensor plugs and pressure sensors will be adapted for compatibility with the Orion TPS design. The sensor plugs will provide in-depth temperature data to support aerothermal and TPS model correlation, and the pressure sensors will provide a flush air data system for validation of the entry and descent aerodynamic environments. In addition, a radiometer design will be matured to measure the radiative component of the reentry heating at two locations on the heat shield. For the back shell, surface thermocouple and pressure port designs will be developed and applied which build upon the heritage of the Space Shuttle Program for instrumentation of reusable surface insulation (RSI) tiles. The quantity and location of the sensors has been determined to balance the needs of the reentry disciplines with the demands of the hardware development, manufacturing and integration. Measurements which provided low relative value and presented significant engineering development effort were, unfortunately, eliminated. The final TPS instrumentation has been optimized to target priority test objectives. The data obtained will serve to provide a better understanding of reentry environments for the Orion capsule design, reduce margins, and potentially reduce TPS mass or provide TPS extensibility for alternative missions.

Kowal, T. John↗

Microfabricated pressure and shear stress sensors

A microfabricated pressure sensor. The pressure sensor comprises a raised diaphragm disposed on a substrate. The diaphragm is configured to bend in response to an applied pressure difference. A strain gauge of a conductive material is coupled to a surface of the raised diaphragm and to at least one of the substrate and a piece rigidly connected to the substrate.

Liu, Chang↗

Influence of Actuator Movement Rate During Acquisition of Inlet Characterization Data

This report considers using a process to acquire performance data for supersonic mixed-compression inlets that is faster and less costly than the previous process. In the previous process for acquiring data during wind tunnel experiments, actuators for backpressuring an inlet moved in discrete increments, paused for dynamics to dampen, measured data for 5 s, recorded the data, and then reduced the data to graphic plots of pressure recovery versus mass capture ratio. This discrete data acquisition procedure was methodical, reliable, and accurate. However, acquiring data to characterize the inlet consumed significant wind-on time. Wind tunnel operation was costly when considering maintenance, energy, and human resources (operators and research team); therefore, the price for each data point was high. This report presents a quicker method to obtain all measurements, one which can also be used in blowdown wind tunnels. This approach, identified as the dynamic inlet characteristic data acquisition procedure, uses in situ dynamic high-speed pressure sensors to measure pressure signals. The backpressuring actuator moves continuously, and measurements from high-speed pressure sensors are recorded as the actuator progresses to and past the incremental points. Despite its advantages, the approach raised the following questions: (1) Will the new process be as accurate as the previous process? and (2) Are there any hidden costs? These concerns are addressed in this report. This report reviews a study that was undertaken to compare wind tunnel experiment data taken using the previous discrete data acquisition procedure with data recorded using the dynamic inlet characterization data acquisition procedure. In this report, the wind tunnel experiment and the study objectives are described. The processes to reduce the data for analysis are explained, and a discussion of the results is given. Finally, conclusions from this study that may guide further work in this area are presented.

Inlet Characterization Curves↗

Electronically scanned multichannel pressure transducer system for cryogenic environments

Research into the application of custom doped piezoresistive silicon pressure sensors has led to a multichannel pressure sensor design that will operate accurately and reliably at cryogenic temperatures. The thermal effects upon multichannel pressure sensors are mapped by thermal calibrations and are represented by sets of nth order coefficients specific to each sensor. The thermal offset and sensitivity variations are corrected by computer algorithms which scan the sensors, recall correction coefficients from thermally induced sensor variations, and apply these to correct the sensor's output measurement uncertainty to within 0.5 percent of full scale output for combined offset and sensitivity. A prototype sensor system has been fabricated, and performance test data are presented.

Chapman, John J.↗

Test Structures Applied to the Rapid Prototyping of Sensors

Recently, test structures were used to aid in the rapid development of a gas sensor and pressure sensor. These sensors were fabricated using co-fired ceramic technology and a multiproject approach. This talk will describe results obtained from a ceramic substrate which contained 36 chips with six variants including the sensors, process control monitors, and an interconnect chip. As far as the authors know, this is the first implementation of multi-projects in co-fired ceramic substrate. The gas sensor is being developed for the Space Shuttle and the pressure gage is being developed as a Martian barometer.

sensors ceramic substrate prototyping↗

Power assist EVA glove development

Structural modeling of the EVA glove indicates that flexibility in the metacarpophalangeal (MCP) joint can be improved by selectively lowering the elasticity of the glove fabric. Two strategies are used to accomplish this. One method uses coil springs on the back of the glove to carry the tension in the glove skin due to pressurization. These springs carry the loads normally borne by the glove fabric, but are more easily deformed. An active system was also designed for the same purpose and uses gas filled bladders attached to the back of the EVA glove that change the dimensions of the back of the glove and allow the glove to bend at the MCP joint, thus providing greater flexibility at this joint. A threshold control scheme was devised to control the action of the joint actuators. Input to the controller was provided by thin resistive pressure sensors placed between the hand and the pressurized glove. The pressure sensors consist of a layer of polyester film that has a thin layer of ink screened on the surface. The resistivity of the ink is pressure dependent, so an extremely thin pressure sensor can be fabricated by covering the ink patch with another layer of polyester film and measuring the changing resistance of the ink with a bridge circuit. In order to sense the force between the hand and the glove at the MCP joint, a sensor was placed on the palmar face of the middle finger. The resultant signal was used by the controller to decide whether to fill or exhaust the bladder actuators on the back of the glove. The information from the sensor can also be used to evaluate the effectiveness of a given control scheme or glove design since the magnitude of the measured pressures gives some idea of the torque required to bend a glove finger at the MCP joint. Tests of this actuator, sensor, and control system were conducted in an 57.2 kPa glove box by performing a series of 90 degree finger bends with a glove without an MCP joint assembly, a glove with the coil spring assembly, and with the four fingered actuated glove. The tests of these three glove designs confirm the validity of the model.

Main, John A.↗

Sensor Development for Active Flow Control

Presented are the developmental efforts for MEMS sensors for a closed-loop active flow control in a low-speed wind tunnel evaluation. The MEMS sensors are designed in-house and fabricated out of house, and the shear sensors are a thermal type that are collocated with temperature and pressure sensors on a flexible polyimide sheet, which conforms to surfaces of a simple curvature. A total of 6 sensors are located within a 1.5 by 3 mm area as a cluster with each sensor being 300 pm square. The thickness of this sensor cluster is 75 pm. Outputs from the shear sensors have been compared with respect to those of the Preston tube for evaluation of the sensors on a flat plate. Pressure sensors are the absolute type and have recorded pressure measurements within 0.05 percent of the tunnel ESP pressure sensor readings. The sensors and signal conditioning electronics have been tested on both a flat plate and a ramp in Langley s 15-Inch Low-Turbulence Tunnel. The system configuration and control PC is configured with LabView, where calibration constants are stored for desired compensation and correction. The preliminary test results are presented within.

Kahng, Seun K.↗

Packaging Technologies for High Temperature Electronics and Sensors

This paper reviews ceramic substrates and thick-film metallization based packaging technologies in development for 500degC silicon carbide (SiC) electronics and sensors. Prototype high temperature ceramic chip-level packages and printed circuit boards (PCBs) based on ceramic substrates of aluminum oxide (Al2O3) and aluminum nitride (AlN) have been designed and fabricated. These ceramic substrate-based chiplevel packages with gold (Au) thick-film metallization have been electrically characterized at temperatures up to 550degC. A 96% alumina based edge connector for a PCB level subsystem interconnection has also been demonstrated recently. The 96% alumina packaging system composed of chip-level packages and PCBs has been tested with high temperature SiC devices at 500degC for over 10,000 hours. In addition to tests in a laboratory environment, a SiC JFET with a packaging system composed of a 96% alumina chip-level package and an alumina printed circuit board mounted on a data acquisition circuit board was launched as a part of the MISSE-7 suite to the International Space Station via a Shuttle mission. This packaged SiC transistor was successfully tested in orbit for eighteen months. A spark-plug type sensor package designed for high temperature SiC capacitive pressure sensors was developed. This sensor package combines the high temperature interconnection system with a commercial high temperature high pressure stainless steel seal gland (electrical feed-through). Test results of a packaged high temperature capacitive pressure sensor at 500degC are also discussed. In addition to the pressure sensor package, efforts for packaging high temperature SiC diode-based gas chemical sensors are in process.

Electronic packaging↗