Search NASA⌕ Search

SEARCH · Search NASA

Results for “program implementation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Materials and Designs for High-Efficacy LED Light Engines

Cree, Inc. conducted a narrow-band downconverter (NBD) materials development and implementation program which will lead to warm-white LED light engines with enhanced efficacy via improved spectral efficiency with respect to the human eye response. New red (600-630nm) NBD materials could result in as much as a 20% improvement in warm-white efficacy at high color quality relative to conventional phosphor-based light sources. Key program innovations included: high quantum yield; narrow peak width; minimized component-level losses due to “cross-talk” and light scattering among red and yellow-green downconverters; and improved reliability to reach parity with conventional phosphors. NBD-enabled downconversion efficiency gains relative to conventional phosphors yielded an end-of-project LED light engine efficacy of >160 lm/W at room temperature and 35 A/cm2, with a correlated color temperature (CCT) of ~3500K and >90 CRI (Color Rending Index). NBD-LED light engines exhibited equivalent luminous flux and color point maintenance at >1,000 hrs. of highly accelerated reliability testing as conventional phosphor LEDs. A demonstration luminaire utilizing an NBD-based LED light engine had a steady-state system efficacy of >150 lm/W at ~3500K and >90 CRI, which exceeded the 2014 DOE R&D Plan luminaire milestone for FY17 of >150 lm/W at just 80 CRI.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Barriers and Opportunities to Broader Adoption of Integrated Demand Side Management at Electric Utilities: A Scoping Study

Integrated demand-side management (IDSM) is a strategic approach to designing and delivering a portfolio of demand side management (DSM) programs to customers. IDSM typically delivers customer centric strategies with the goal of increasing the amount of DSM in the field, but doing so in a way that integrates various measures and technologies to improve their collective performance and/or penetration. Specifically, IDSM can be defined as the integrated or coordinated delivery of three or more of: (1) energy efficiency (EE), (2) demand response (DR), (3) distributed generation (DG), (4) storage, (5) electric vehicle (EV) technologies, and (6) time-based rate programs to residential and commercial electric utility customers. The electric industry’s limited experience deploying IDSM to date suggests that significant barriers may exist. This report explores recent electric utility experience with IDSM to provide an assessment of the barriers and potential benefits perceived or experienced by program administrators in their attempts to implement integrated programs. The research draws on surveys and interviews with eleven staff from a sample of eight DSM program administrators and program implementers who were currently implementing or had previously attempted to implement an IDSM program or initiative. Respondents provided their perspectives on drivers for IDSM and barriers to broader deployment. They also reported on actions they had undertaken to promote expanded delivery of IDSM and provided their assessments of the most important under-tapped opportunities for expanding IDSM efforts, both for program administrator and regulatory organizations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance Evaluation of the CHKED Multi-Elemental Analysis and Software

The Hybrid K-edge Densitometer (HKED) is a high precision safeguards assay system developed by Ottmar and Eberle [1] for quantification of the U and Pu concentrations of dissolver solutions in spent nuclear fuel reprocessing. The HKED measurement supplements traditional destructive assay methods such as Isotope Dilution Mass Spectrometry (IDMS) and is an essential component of the international safeguards program implementation at these facilities. The Canberra Hybrid K-Edge Densitometry (CHKED) software was recently developed by Canberra Industries to better address the changing composition of the nuclear fuel cycle by addition of a multi-elemental analysis capability to the K-Edge transmission measurement. Our evaluation of the CHKED software was performed at the request of the International Atomic Energy Agency (IAEA) to examine the functionality and performance of the CHKED software and algorithms and identify potential areas for improvement of the software. The reader is assumed to be familiar with the HKED technique and its current implementation in safeguards assay of U and Pu in the nuclear fuel cycle. The Canberra Hybrid K-Edge Densitometry CHKED software replicates functionality of the older VMSbased Hybrid K-Edge Densitometer (HKED) software and incorporates additional analysis algorithms and tools. When the traditional HKED analyses are selected, the CHKED software appears to faithfully reproduce the measurement results as reported by the older software. The CHKED software includes a Multi-elemental K-Edge (MEKED) analysis based in part on algorithms devised at Los Alamos National Laboratory. In principle, the MEKED analysis represents a significant advancement over the traditional HKED analysis, providing a capability to analyze the actinide concentrations from complex solutions, such as low U:Pu ratios (e.g., U:Pu = 1:1) including additional minor actinide components such as Np and Am. However, this MEKED analysis is somewhat limited by reliance on a region of interest (ROI) analysis of the spectrum, the need for extensive calibration measurements and a simplistic interpretation of the KED transmission spectrum. Finally, the MEKED algorithm set associated with the CHKED software (V1.0) acquired by Oak Ridge National Laboratory (ORNL) from Canberra Industries does not seem to be “finished” (e.g., the MEKED analysis seems to only determine measurement results for two actinides with while results for the minor actinides appear to be highly dependent on declaration values).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

China Green Low-Carbon City Index

The main purpose of the new China Green Low-Carbon City Index (CGLCI, or City Index) is to evaluate the status of green and low-carbon development for a large number of Chinese cities. Chinese cities are formulating plans and implementing programs to address national initiatives, especially the national low-carbon pilot program for 36 cities and six provinces. However, there is not yet an established framework for measuring, reporting, or evaluating low-carbon progress across Chinese cities, despite the development of a number of Chinese and international city indicator systems. The new China City Index highlights energy use and carbon emissions of Chinese cities, along with environmental and socio-economic indicators. We selected metrics (indicators) that have data available in China’s statistical system, are commonly used internationally, and reflect Chinese policy goals. We then benchmarked and ranked Chinese cities in terms of their status and progress, identified potential areas for improvement, and identified top-runners.

54 ENVIRONMENTAL SCIENCES↗

Distributed Wind Resilience Metrics for Electric Energy Delivery Systems: Comprehensive Literature Review

While most people have a general concept of what it means to be “resilient,” an examination of definitions from different sources reveals that there are key commonalities but key differences as well. The lack of a generally accepted definition and application of resilience extends to electric energy delivery systems. Without an accepted definition, it is difficult to implement programs or processes to improve resiliency. In this paper, existing work from industry, regulatory bodies, and national laboratories to define and apply resilience to electric energy delivery systems is studied to understand the key components to define resilience and better understand associated metrics. This understanding is then applied to distributed wind for a specific example of how resilience of a system is affected by the technologies and generation sources used to support it. A key finding is that there is no “one size fits all” process for resilience. Each system has a “distinctiveness” characteristic, which qualifies the possibility of differences in resilience due to different threats, geography, stakeholders, risk tolerance, and mitigations. The distinctiveness characteristic extends to distributed wind, where different configurations may lend the distributed wind to contribute to the resilience of systems in a variety of ways. The findings of this research demonstrate the need for a resilience framework that can be readily applied by stakeholders to improve resilience based on the specific system, threat, risk tolerance and stakeholders.

17 WIND ENERGY↗

China Green Low-Carbon City Index: Report on the Performance of 100+ Cities (2010-2015)

The main purpose of the new China Green Low-Carbon City Index (CGLCI, or City Index ) is to evaluate the status of green and low-carbon development for a large number of Chinese cities. Chinese cities are formulating plans and implementing programs to address national initiatives, especially the national low-carbon pilot program for 36 cities and six provinces. However, there is not yet an established framework for measuring, reporting, or evaluating low-carbon progress across Chinese cities, despite the development of a number of Chinese and international city indicator systems. The new China City Index highlights energy use and carbon emissions of Chinese cities, along with environmental and socio-economic indicators. We selected metrics (indicators) that have data available in China’s statistical system, are commonly used internationally, and reflect Chinese policy goals. (See Table ES-1.) We then benchmarked and ranked Chinese cities in terms of their status and progress, identified potential areas for improvement, and identified top-runners. By “low-carbon” we mean reducing emissions of carbon dioxide (CO 2 ) and methane (CH 4 ), with a focus on energy-related CO 2 . The term “carbon” is used as short-hand for these GHGs throughout the report. By “green” we recognize multiple environmental parameters related to urbanization and climate change: air quality, water use, solid waste, transport networks, and urban green space. In early 2017, China expanded its low-carbon pilot cities program, adding 45 more cities.

54 ENVIRONMENTAL SCIENCES↗

Commercial Building Energy Code Field Study (Final Report)

What is the dollar value of increasing compliance with the energy code? Ultimately, this is the question that policy makers, funders, and program implementers care about. With this in mind, Pacific Northwest National Laboratory (PNNL) developed a new methodology capable of determining how much energy cost savings could potentially be gained through better compliance with the code (Rosenberg et al. 2016). On March 2, 2016 DOE issued Funding Opportunity Announcement (FOA) Number DE-FOA-0001532, requesting proposals to develop and test a methodology for identifying the commercial energy code requirements that can provide the maximum cost-effective energy and cost savings through increased compliance. Awarded to the Institute for Market Transformation, this report summarizes the development and testing of a commercial code compliance methodology, including a summary of results, statistical analysis of sample, and best practices for others implementing a commercial energy code compliance field study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing and benchmarking the fidelity of posterior inference methods for astrophysics data analysis

In this era of large and complex astronomical survey data, interpreting, validating, and comparing inference techniques becomes increasingly difficult. This is particularly critical for emerging inference methods like Simulation-Based Inference (SBI), which offer significant speedup potential and posterior modeling flexibility, especially when deep learning is incorporated. We present a study to assess and compare the performance and uncertainty prediction capability of Bayesian inference algorithms – from traditional MCMC sampling of analytic functions to deep learning-enabled SBI. We focus on testing the capacity of hierarchical inference modeling in those scenarios. Before we extend this study to cosmology, we first use astrophysical simulation data to ensure interpretability. We demonstrate a probabilistic programming implementation of hierarchical and non-hierarchical Bayesian inference using simulations derived from the DeepBench software library, a benchmarking tool developed by our group that generates simple and controllable astrophysical objects from first principles. This study will enable astronomers and physicists to harness the inference potential of these methods with confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electricity Subsector Transmission Resilience Maturity Model (TRMM) User Guide

The electric transmission sector is facing a range of threats to its functionality that are either new, more severe than experienced in earlier years, or more well understood. Such threats include more frequent and more severe extreme weather events, wildfires, droughts, and human-caused physical and cyberattacks. They also include geological, electromagnetic, and biological events. The novelty or increasing severity of these threats creates a significant need for transmission owners to implement programs to prevent, prepare for, respond to, and recover from such incidents. The national and economic security of the United States depends on the reliable functioning of the Nation’s critical infrastructure in the face of such threats, and the transmission networks are essential components of that infrastructure. The Electricity Subsector Transmission Resilience Maturity Model (TRMM) is a tool that a transmission organization can use to objectively evaluate and benchmark its currently established transmission resilience strategies, programs, policies, and investments, in order to target and prioritize enhancements where needed. The TRMM was developed to address the unique characteristics of the transmission system. The model can enable users to: • evaluate and benchmark their organization’s resilience capabilities, effectively and consistently • prioritize actions and investments to improve the resilience of their systems • share transmission-related knowledge, best practices, and relevant references within their organization and with business partners as a means to improve resilience capabilities • contribute to increasing the overall resilience of the Nation’s transmission systems. The TRMM provides descriptive rather than prescriptive industry-focused guidance. The model content is presented at a high level of abstraction so that it can be interpreted by transmission organizations of various types, structures, and sizes. The model is designed to an be easy-to-use, self-assessment tool.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Los Alamos National Laboratory new generation standard nuclear material storage container - the SAVY4000 design

Incidents involving release of nuclear materials stored in containers of convenience such as food pack cans, slip lid taped cans, paint cans, etc. has resulted in defense board concerns over the lack of prescriptive performance requirements for interim storage of nuclear materials. Los Alamos National Laboratory (LANL) has shared in these incidents and in response proactively moved into developing a performance based standard involving storage of nuclear material (RD003). This RD003 requirements document has sense been updated to reflect requirements as identified with recently issued DOE M 441.1-1 'Nuclear Material Packaging Manual'. The new packaging manual was issued at the encouragement of the Defense Nuclear Facilities Safety Board with a clear directive for protecting the worker from exposure due to loss of containment of stored materials. The Manual specifies a detailed and all inclusive approach to achieve a high level of protection; from package design & performance requirements, design life determinations of limited life components, authorized contents evaluations, and surveillance/maintenance to ensure in use package integrity over time. Materials in scope involve those stored outside an approved engineered-contamination barrier that would result in a worker exposure of in excess of 5 rem Committed Effective Does Equivalent (CEDE). Key aspects of meeting the challenge as developed around the SAVY-3000 vented storage container design will be discussed. Design performance and acceptance criteria against the manual, bounding conditions as established that the user must ensure are met to authorize contents in the package (based upon the activity of heat-source plutonium (90% Pu-238) oxide, which bounds the requirements for weapons-grade plutonium oxide), interface as a safety class system within the facility under the LANL plutonium facility DSA, design life determinations for limited life components, and a sense of design specific surveillance program implementation as LANL moves forward into production and use of the SAVY-3000 will all be addressed. The SAVY-3000 is intended as a work horse package for the DOE complex as a vented storage container primarily for plutonium in solid form.

99 GENERAL AND MISCELLANEOUS↗

An Authorized Container Program at the Nevada Test Site

An Authorized User of Containers Program was implemented for National Security Technologies, LLC (NSTec), at the Nevada Test Site (NTS). This paper and the associated presentation will address NSTec’s lessons learned for implementing this program. It will describe some of the major difficulties in performing this activity and how these challenges were addressed to allow NSTec to use the model DT-23 containers.

42 ENGINEERING↗

Overview of the U.S. DOE Accident Tolerant Fuel Development Program

The United States Fuel Cycle Research and Development Advanced Fuels Campaign has been given the responsibility to conduct research and development on enhanced accident tolerant fuels with the goal of performing a lead test assembly or lead test rod irradiation in a commercial reactor by 2022. The Advanced Fuels Campaign has defined fuels with enhanced accident tolerance as those that, in comparison with the standard UO2-Zircaloy system currently used by the nuclear industry, can tolerate loss of active cooling in the reactor core for a considerably longer time period (depending on the LWR system and accident scenario) while maintaining or improving the fuel performance during normal operations and operational transients, as well as design-basis and beyond design-basis events. This paper provides an overview of the FCRD Accident Tolerant Fuel program. The ATF attributes will be presented and discussed. Attributes identified as potentially important to enhance accident tolerance include reduced hydrogen generation (resulting from cladding oxidation), enhanced fission product retention under severe accident conditions, reduced cladding reaction with high-temperature steam, and improved fuel-cladding interaction for enhanced performance under extreme conditions. To demonstrate the enhanced accident tolerance of candidate fuel designs, metrics must be developed and evaluated using a combination of design features for a given LWR design, potential improvements to that design, and the design of an advanced fuel/cladding system. The aforementioned attributes provide qualitative guidance for parameters that will be considered for fuels with enhanced accident tolerance. It may be unnecessary to improve in all attributes and it is likely that some attributes or combination of attributes provide meaningful gains in accident tolerance, while others may provide only marginal benefits. Thus, an initial step in program implementation will be the development of quantitative metrics. A companion paper in these proceedings provides an update on the status of establishing these quantitative metrics for accident tolerant LWR fuel.1 The United States FCRD Advanced Fuels Campaign has embarked on an aggressive schedule for development of enhanced accident tolerant LWR fuels. The goal of developing such a fuel system that can be deployed in the U.S. LWR fleet in the next 10 to 20 years supports the sustainability of clean nuclear power generation in the United States.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Westinghouse Accident Tolerant Fuel Program

The PowerPoint presentation includes a timeline for the program implementation, the technical approach taken, a summary of testing results, a status of task 2, what has been done to share the results so far, and a summary of upcoming work.

ATR, HIFR, advanced test reactor, high flux isotop↗

Lessons Learned: Community Solar for Municipal Utilities

This report outlines the work that STAT has completed, discusses the range of approaches utilities are taking, and highlights several challenges municipal utilities face in deciding whether and how to pursue community solar. As this report shows, there is no 'silver bullet' in terms of municipal utility community solar design or implementation - programs vary significantly and are highly dependent on localized contexts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Innovative Open-Source Energy Software to Drive and Enable Energy Savings and Process Optimization

U.S. Department of Energy (DOE) energy system-analysis software tools have been used for years helping to identify over 170 TBTU/year of energy savings through the Save Energy Now “Energy Savings Assessment” and Better Plants “In-Plant Training” Programs. While most of the fundamental energy savings opportunities do not evolve much with time, computer technology never stops, leaving most of these software tools inoperable on modern computers.This has sparked an initiative to revitalize the DOE energy system analysis tools into a new, open-source, integrated software tool suite - MEASUR. Designed for industrial energy coordinators, engineers, utility-program implementers and individuals who are interested in improving system efficiency, MEASUR can aide users in identifying, assessing, and quantifying energy savings opportunities within pump, fan, process heating, steam, motors, and compressed air systems. In addition, the software contains over 40 equipment and property calculators for simple energy-related calculations and analyses.This paper will present a results comparison for each energy-consuming system using data from past DOE-sponsored energy assessments (to establish the accuracy of the savings algorithms) to validate and verify the accuracy of the energy and cost savings calculated by MEASUR. Additionally, an example highlighting 3rd-party development of the tool’s opensource framework into real-time sensor systems and efficiency-optimization will be presented.

Armstrong, Kristina↗

End-Use Load Profiles for the U.S. Building Stock: Technical Advisory Group Meeting #11

A technical advisory group guided the End-Use Load Profiles dataset development to ensure that the direction and outcomes of the work were aligned with market needs. The technical advisory group included roughly 100 representatives from organizations that were likely to use the resulting load profiles in their work, including utility companies, utility program implementers, grid operators, consultancies, research centers, state regulatory agencies, and regional energy efficiency organizations. This is the presentation from TAG Meeting #11.

buildings↗

Repackaging of High Fissile TRU Waste at the Transuranic Waste Processing Center - 13240

Twenty-six drums of high fissile transuranic (TRU) waste from Oak Ridge National Laboratory (ORNL) operations were declared waste in the mid-1980's and placed in storage with the legacy TRU waste inventory for future treatment and disposal at the Waste Isolation Pilot Plant (WIPP). Repackaging and treatment of the waste at the TRU Waste Packaging Center (TWPC) will require the installation of additional equipment and capabilities to address the hazards for handling and repackaging the waste compared to typical Contact Handled (CH) TRU waste that is processed at the TWPC, including potential hydrogen accumulation in legacy 6M/2R packaging configurations, potential presence of reactive plutonium hydrides, and significant low energy gamma radiation dose rates. All of the waste is anticipated to be repackaged at the TWPC and certified for disposal at WIPP. The waste is currently packaged in multiple layers of containers which presents additional challenges for repackaging activities due to the potential for the accumulation of hydrogen gas in the container headspace in quantities than could exceed the Lower Flammability Limit (LFL). The outer container for each waste package is a stainless steel 0.21 m{sup 3} (55-gal) drum which contains either a 0.04 m{sup 3} or 0.06 m{sup 3} (10-gal or 15-gal) 6M drum. The inner 2R container in each 6M drum is ∼12 cm (5 in) outside diameter x 30-36 cm (12-14 in) long and is considered to be a > 4 liter sealed container relative to TRU waste packaging criteria. Inside the 2R containers are multiple configurations of food pack cans, pipe nipples, and welded capsules. The waste contains significant quantities of high burn-up plutonium oxides and metals with a heavy weight percentage of higher atomic mass isotopes and the subsequent in-growth of significant quantities of americium. Significant low energy gamma radiation is expected to be present due to the americium in-growth. Radiation dose rates on inner containers are estimated to be 1-3 mSv/hr (100-300 mrem/hr) with an unshielded dose rate on the waste itself of over 10 mSv/hr (1 rem/hr). Additional equipment to be installed at the TWPC will include a new perma-con enclosure and a shielded/inert glovebox in the process building to repackage and stabilize the waste. All of the waste will be repackaged into Standard Pipe Overpacks. Most of the waste (21 of the 26 drums) is expected to be repackaged at the food-pack can level (i.e. the food-pack cans will not be opened). Five of the incoming waste containers are expected to be repackaged at the primary waste level. Three of the containers exceed the 200 gram Pu-239 Fissile Gram Equivalent (FGE) limit for the Standard Pipe Overpack. These three containers will be repackaged down to the primary waste level and divided into eight Standard Pipe Overpacks for shipment to WIPP. Two containers must be stabilized to eliminate any reactive plutonium hydrides that may be present. These containers will be opened in the inert, shielded glovebox, and the remaining corroded plutonium metal converted to a stable oxide form by using a 600 deg. C tube furnace with controlled oxygen feed in a helium carrier gas. The stabilized waste will then be packaged into two Standard Pipe Overpacks. Design and build out activities for the additional repackaging capabilities at the TWPC are scheduled to begin in Fiscal Year 2013 with repackaging, stabilization, and certification activities scheduled to begin in Fiscal Year 2014. Following repackaging and stabilization activities, the Standard Pipe Overpacks will be certified for disposal at WIPP utilizing Non-Destructive Examination (NDE) to verify the absence of prohibited items and Non-Destructive Assay (NDA) to verify the isotopic content under the TWPC WIPP certification program implemented by the Central Characterization Project (CCP). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗