Search NASA⌕ Search

SEARCH · Search NASA

Results for “programmatic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Taking Risk Assessment and Management to the Next Level: Program-Level Risk Analysis to Enable Solid Decision-Making on Priorities and Funding

A multi-level (facility and programmatic) risk assessment was conducted for the facilities in the Nevada National Security Site (NNSS) Readiness in Technical Base and Facilities (RTBF) Program and results were included in a new Risk Management Plan (RMP), which was incorporated into the fiscal year (FY) 2010 Integrated Plans. Risks, risk events, probability, consequence(s), and mitigation strategies were identified and captured, for most scope areas (i.e., risk categories) during the facilitated risk workshops. Risk mitigations (i.e., efforts in addition to existing controls) were identified during the facilitated risk workshops when the risk event was identified. Risk mitigation strategies fell into two broad categories: threats or opportunities. Improvement projects were identified and linked to specific risks they mitigate, making the connection of risk reduction through investments for the annual Site Execution Plan. Due to the amount of that was collected, analysis to be performed, and reports to be generated, a Risk Assessment/ Management Tool (RAMtool) database was developed to analyze the risks in real-time, at multiple levels, which reinforced the site-level risk management process and procedures. The RAMtool database was developed and designed to assist in the capturing and analysis of the key elements of risk: probability, consequence, and impact. The RAMtool calculates the facility-level and programmatic-level risk factors to enable a side-by-side comparison to see where the facility manager and program manager should focus their risk reduction efforts and funding. This enables them to make solid decisions on priorities and funding to maximize the risk reduction. A more active risk management process was developed where risks and opportunities are actively managed, monitored, and controlled by each facility more aggressively and frequently. risk owners have the responsibility and accountability to manage their assigned risk in real-time, using the RAMtool database.

Nelson, J. G.↗

Risk Assessment/Management Tool

RAMTool performs the following: • A tool to perform facility and programmatic risk assessments, produce risk registers, develop risk management plans (RMPs), link risks to improvement/risk-reduction projects, and actively manage risks • Ability to conduct risk assessments. Ease of determination of probability and consequence based on industry standard risk matrices. Complies with site risk management performance document. Provides multiple outputs/report for required risk forms. Conduct quick risk data analysis. • Performs/calculates a facility risk factor (RF) and a programmatic RF. Supports project and initiative prioritization and funding in order to make solid decisions on risk reduction. Assigns responsibility and accountability at a risk owner (RO) level. Monitors and tracks progress toward completing mitigation strategies. Ability to import massive amounts of data at the push of a button. Integrates development of a Risk Management Plan (RMP) Built for ease-of-use – design, built, and used by technical/management personnel. Can be customized (functions and/or reports) for further analysis

Carlos Castillo, Jerel Nelson↗

Test and Evaluation for Enhanced Security: A Quantitative Method to Incorporate Expert Knowledge into Test Planning Decisions.

Complex systems are comprised of technical, social, political and environmental factors as well as the programmatic factors of cost, schedule and risk. Testing these systems for enhanced security requires expert knowledge in many different fields. It is important to test these systems to ensure effectiveness, but testing is limited to due cost, schedule, safety, feasibility and a myriad of other reasons. Without an effective decision framework for Test and Evaluation (T&E) planning that can take into consideration technical as well as programmatic factors and leverage expert knowledge, security in complex systems may not be assessed effectively. Therefore, this paper covers the identification of the current T&E planning problem and an approach to include the full variety of factors and leverage expert knowledge in T&E planning through the use of Bayesian Networks (BN).

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

APPLICATION OF MATURITY MODELS FOR EVALUATING CYBERSECURITY PROGRAMS AT NUCLEAR AND RADIOLOGICAL FACILITIES

Maturity models can be used to provide government agencies, industry associations, and organizations operating nuclear facilities with the ability to quickly evaluate the maturity of their cybersecurity programs and identify areas to prioritize for improvement. The Cybersecurity Capability Maturity Model (C2M2) was developed by the U.S. Department of Energy to allow organizations in the energy sector to evaluate the programmatic capabilities of their cybersecurity programs in a consistent manner, communicate programmatic maturity information, prioritize cybersecurity investments in targeted areas of concern, and track how the maturity of their cybersecurity program evolves over time. The C2M2 is designed for use by any critical infrastructure organization regardless of ownership, structure, or size. The C2M2 can be easily fine-tuned to access the maturity of nuclear cybersecurity programs and their application at individual facilities. Built on a foundation of existing cybersecurity standards, frameworks, programs, and initiatives, the model features 10 security domains. Performance in each security domain is characterized using a structured set of cybersecurity practices that represent activities an organization can perform to improve cybersecurity in their domain. Each practice can be quickly evaluated as being either fully, largely, partially, or not implemented. Once practices are evaluated for each security domain, the model defines four maturity indicator levels that apply independently to each domain in the model. To earn a maturity level in a given domain, an organization must adequately perform all the practices for that maturity level and its predecessor level(s). A small assessment team can conduct a C2M2 assessment in a single day. A screening version of the C2M2 allows an initial look at the maturity of nuclear cybersecurity programs that could be completed in under an hour.

Cyber security, Nuclear security, maturity model↗

System Retrofits in Efficiency Programs: Track Record and Outlook

Commercial building retrofits are often limited to simple upgrades of individual building components such as equipment or lamp replacements. These equipment- or component-level retrofits have been shown to have less potential for whole building energy savings (50% less in studied cases) compared to comprehensive system-based approaches. System retrofits with their potential for much greater savings are critical to achieving aggressive energy reduction goals in the existing building stock but to date there has been little deep analysis of the track record and trends for systems retrofits in commercial buildings. This paper addresses several questions: 1. To what extent are systems retrofits taking place in the building retrofit marketplace today? 2. Do current systems retrofits in fact save more energy than component retrofits? 3. What kinds of efficiency measures are currently most prevalent in system retrofits? 4. Does systems adoption vary across different retrofit programmatic approaches (e.g. utility incentive programs, federal retrofit programs, ESCOs)? Findings, based on an analysis of retrofit data from 12,000 projects across the U.S. from custom utility incentive programs, federal retrofit programs, and Energy Service Companies (ESCOs), indicate the state of the current market with respect to adoption of systems technologies. A wide range of stakeholders were also interviewed to define the challenges and opportunities for greater deployment. A range of barriers is presented including technical and structural (i.e. programmatic, policy), along with recommendations to accelerate deployment of these strategic approaches.

Regnier, Cynthia↗

Sensitivity of ATF Experiments in the Center Flux Trap of the Advanced Test Reactor to Adjacent Experiments

Irradiation experiments conducted in the Idaho National Laboratory’s Advanced Test Reactor are typically assumed to have little effect on one another. This assumption does not hold true for certain experiments in close proximity. To evaluate the impacts on safety and programmatic parameters of experiments in the center flux trap, the contents of the adjacent H and inner-A positions were modeled with a range of possible irradiation targets. First, neutron flux maps with experiments in those positions were compared against a baseline configuration. Next, several safety and programmatic parameters for a generic accident-tolerant fuel test train were calculated. It was shown that these parameters can exhibit considerable sensitivity to the contents of the H and A experiment positions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ATF-2 Sensitivity M&C 2023 (Slides)

Irradiation experiments in the Idaho National Laboratory's Advanced Test Reactor are typically assumed to have little effect on one another. This assumption does not hold true for certain experiments in close proximity. To evaluate the impacts on safety and programmatic parameters of experiments in the center flux trap, the contents of the adjacent H and inner-A positions are modeled with a range of possible irradiation targets. First, neutron flux maps with experiments in those positions are compared to those of a water-filled configuration. Then, several safety and programmatic parameters for a generic accident-tolerant fuel test train are calculated. It is shown that these parameters can exhibit considerable sensitivity to the contents of the H and A experiment positions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Defining Nature and Extent of Contamination for the Waste Management Area C RCRA Corrective Action Process at the Hanford Site in Southeast Washington - 17403

Determination of the nature and extent of contamination is a critical task in any Resource Conservation and Recovery Act of 1976 (RCRA) Facility Investigation. Nature and extent are typically defined through field investigation results. In some cases, however, physical and/or programmatic limitations on field work can impede efforts to define nature and extent based on field work alone. Both physical and programmatic restrictions affected efforts to characterize soil contamination at Waste Management Area C, on the U.S. Department of Energy's Hanford Site. As a result, fate and transport modeling was undertaken to enhance the definition of the nature and extent of soil contamination at Waste Management Area C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Methodology for Loading the Advanced Test Reactor Driver Core for Experiment Analysis

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is one of the premier irradiation facilities in the world. The ATR hosts experiments from a variety of laboratories, companies, and disciplines. Because of its flexibility in providing customized irradiation conditions to experiments, such as coolant chemistry, temperature, and reactor power, analysis for experiments, both from a programmatic and safety perspective, can be a challenging endeavor. Because of these experiment variables, there is always an effort to improve upon the existing analysis methodology in order to provide the sponsor of any given experiment with the most accurate predictions possible. The paper discusses the effort to improve upon the methodology for loading the ATR driver core for experiment analysis. Experiment analysis at INL is generally broken up into three separate disciplines: neutronics, thermal-hydraulics, and structural. The focus of this paper is neutronics analysis. After the experiment has a preliminary design, the neutronics analyst will create a model in the Monte Carlo N-Particle (MCNP) transport code to calculate fuel and material heating rates from MCNP tallies and provide those to the thermal-hydraulics analyst, and calculate reactivity worths, perturbation on the axial fission profile of the ATR driver core by the experiment, void worths, and experiment backup worths. Also, there are usually several programmatic parameters that the experiment sponsor requests that the neutronics analyst calculates. These can include heat generation rates, burnup and displacements per atom (DPA). In order to accurately analyze these parameters, an important input into the physics analyst's MCNP model is the loading of the ATR driver core. The ATR driver core consists of 40, 19-plate highly-enriched uranium (HEU) fuel elements, arranged in a serpentine shape, as pictured in Figure 1. The ATR driver core is responsible for the vast majority of the thermal power of the reactor and the nuclear interactions with the experiments being irradiated in ATR. A unique feature of ATR is the 'power tilt' across the reactor. A power tilt means that the Northwest, Northeast, Southwest, and Southeast Lobes of ATR frequently operate at different powers, providing different irradiation conditions for the experiments in and around the lobes of the reactor. In order to achieve lobe power splits, different fuel elements for each of the 40 positions are chosen by ATR Reactor Engineering so that lobe power splits can be maintained during an operating cycle. A typical fuel loading for an ATR cycle consists of 14 to 18 new fuel elements and 2 to 26 depleted fuel elements. These loadings are typically chosen from three different types of fuel elements. All three ATR fuel element types share a common design, spelled out in Chapter 4 of the ATR Safety Analysis Report (SAR). The fuel element meat is HEU UAlx dispersion fuel sandwiched between aluminum cladding with a length of 121.92 cm (4 ft), with 19 plates per fuel element. The three variations of this common design are designated by the first two letters in their serial numbers: XA, YA, and NB. XA elements are most commonly used. These elements have nominally 1075 g of uranium-235 and 0.66 g of boron-10. The NB elements have the same uranium-235 loading as the XA elements, but no boron in any plates. These elements are used when excess reactivity is needed. The YA elements have the same loading as the XA elements, except that the outermost plate (Plate 19) has no boron or uranium. These elements are used to mitigate aged reflector damage. In order to accurately model the ATR driver core, all three types of fuel elements must be accounted for in the MCNP model. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Criticality Safety Controls and the Safety Basis at PFP

With the implementation of DOE Order 420.1B, Facility Safety, and DOE-STD-3007-2007, 'Guidelines for Preparing Criticality Safety Evaluations at Department of Energy Non-Reactor Nuclear Facilities', a new requirement was imposed that all criticality safety controls be evaluated for inclusion in the facility Documented Safety Analysis (DSA) and that the evaluation process be documented in the site Criticality Safety Program Description Document (CSPDD). At the Hanford site in Washington State the CSPDD, HNF-31695, 'General Description of the FH Criticality Safety Program', requires each facility develop a linking document called a Criticality Control Review (CCR) to document performance of these evaluations. Chapter 5, Appendix 5B of HNF-7098, Criticality Safety Program, provided an example of a format for a CCR that could be used in lieu of each facility developing its own CCR. Since the Plutonium Finishing Plant (PFP) is presently undergoing Deactivation and Decommissioning (D&D), new procedures are being developed for cleanout of equipment and systems that have not been operated in years. Existing Criticality Safety Evaluations (CSE) are revised, or new ones written, to develop the controls required to support D&D activities. Other Hanford facilities, including PFP, had difficulty using the basic CCR out of HNF-7098 when first implemented. Interpretation of the new guidelines indicated that many of the controls needed to be elevated to TSR level controls. Criterion 2 of the standard, requiring that the consequence of a criticality be examined for establishing the classification of a control, was not addressed. Upon in-depth review by PFP Criticality Safety staff, it was not clear that the programmatic interpretation of criterion 8C could be applied at PFP. Therefore, the PFP Criticality Safety staff decided to write their own CCR. The PFP CCR provides additional guidance for the evaluation team to use by clarifying the evaluation criteria in DOE-STD-3007-2007. In reviewing documents used in classifying controls for Nuclear Safety, it was noted that DOE-HDBK-1188, 'Glossary of Environment, Health, and Safety Terms', defines an Administrative Control (AC) in terms that are different than typically used in Criticality Safety. As part of this CCR, a new term, Criticality Administrative Control (CAC) was defined to clarify the difference between an AC used for criticality safety and an AC used for nuclear safety. In Nuclear Safety terms, an AC is a provision relating to organization and management, procedures, recordkeeping, assessment, and reporting necessary to ensure safe operation of a facility. A CAC was defined as an administrative control derived in a criticality safety analysis that is implemented to ensure double contingency. According to criterion 2 of Section IV, 'Linkage to the Documented Safety Analysis', of DOESTD-3007-2007, the consequence of a criticality should be examined for the purposes of classifying the significance of a control or component. HNF-PRO-700, 'Safety Basis Development', provides control selection criteria based on consequence and risk that may be used in the development of a Criticality Safety Evaluation (CSE) to establish the classification of a component as a design feature, as safety class or safety significant, i.e., an Engineered Safety Feature (ESF), or as equipment important to safety; or merely provides defense-in-depth. Similar logic is applied to the CACs. Criterion 8C of DOE-STD-3007-2007, as written, added to the confusion of using the basic CCR from HNF-7098. The PFP CCR attempts to clarify this criterion by revising it to say 'Programmatic commitments or general references to control philosophy (e.g., mass control or spacing control or concentration control as an overall control strategy for the process without specific quantification of individual limits) is included in the PFP DSA'. Table 1 shows the PFP methodology for evaluating CACs. This evaluation process has been in use since February of 2008 and has proven to be simple and effective. Each control identified in the applicable new/revised CSE is evaluated via the table. The results of this evaluation are documented in tables attached to the CCR as an appendix, for each CSE, to the base document.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dexterity test data contribute to reduction in leaded glovebox gloves use

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (T A-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes. Using an integrated approach, controls have been developed and implemented through an efficient Glovebox Glove Integrity Program. A key element of this program is to consider measures that lower the overall risk of glovebox operations. Line management who own glovebox processes through this program make decisions on which type of glovebox gloves (hereafter referred to as gloves), the weakest component of this safety-significant system, would perform best in these aggressive environments. As Low as Reasonably Achievable considerations must be balanced with glove durability and worker dexterity, both of which affect the final overall risk of the operation. In the past, lead-loaded (leaded) gloves made from Hypalon(reg.) were the primary glove for programmatic operations at TA55. Replacing leaded gloves with unleaded gloves for certain operations would lower the overall risk as well as reduce the amount of mixed transuranic waste. This effort contributes to the Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost-effectiveness, and formality of glovebox operations. In this report, the pros and cons of wearing leaded gloves, the effect of leaded gloves versus unleaded gloves on task performance using standard dexterity tests, the justification for switching from leaded to unleaded gloves, and the pollution prevention benefits of this dramatic change in the glovebox system are presented.

42 ENGINEERING↗

Multifamily Weatherization Resources: Getting Started

This presentation is part of a session providing an overview of the multifamily weatherization process from programmatic, technical, grantee, and Subgrantee perspectives and feature a panel discussion exploring the day-to-day activities of a multifamily program and how they differ from single-family weatherization projects.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Multifamily Weatherization Resources: Compliance and Scaling

This presentation is part of a session providing an overview of the multifamily weatherization process from programmatic, technical, grantee, and Subgrantee perspectives and feature a panel discussion exploring the day-to-day activities of a multifamily program and how they differ from single-family weatherization projects.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

On the origin of low-energy electrons in the inner magnetosphere: Fluxes and pitch-angle distributions

Correct knowledge of the plasma fluxes in the inner magnetosphere is crucial for both scientific and programmatic applications. Knowledge of the low-energy electrons (approximately tens to hundreds of eV) in the inner magnetosphere is particularly important since these electrons are acted upon by various physical processes, accelerating the electrons to higher energies, and also causing their loss. However, measurements of low-energy electrons are challenging, and as a result, this population has been somewhat neglected previously. This work concerns observations of low-energy electrons made by the Helium Oxygen Proton Electron instrument on board the Van Allen Probes satellites and also observations from geosynchronous orbit made by the Magnetospheric Plasma Analyzer on board Los Alamos National Laboratory satellites. The fluxes of electrons from ~30 eV to 1 keV are quantified as a function of pitch-angle, McIlwain L parameter, and local time for both quiet and active periods. Results indicate two sources for low-energy electrons in this energy range: the low-energy tail of the electron plasma sheet and the high-energy tail of the dayside ionosphere. These populations are identified primarily as a result of their different pitch-angle distributions. Field-aligned outflows from the dayside ionosphere are observed at all L shells during quiet and active periods. Our findings also demonstrate that the dayside electron field-aligned fluxes at ~30 eV are particularly strong between L values of 6 and 7, indicating an enhanced source within the polar ionosphere.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid Ultra‐Microporous Materials for Selective Xenon Adsorption and Separation

Abstract The demand for Xe/Kr separation continues to grow due to the industrial significance of high‐purity Xe gas. Current separation processes rely on energy intensive cryogenic distillation. Therefore, less energy intensive alternatives, such as physisorptive separation, using porous materials, are required. Herein we show that an underexplored class of porous materials called hybrid ultra‐microporous materials (HUMs) affords new benchmark selectivity for Xe separation from Xe/Kr mixtures. The isostructural materials, CROFOUR‐1‐Ni and CROFOUR‐2‐Ni, are coordination networks that have coordinatively saturated metal centers and two distinct types of micropores, one of which is lined by CrO 4 2− (CROFOUR) anions and the other is decorated by the functionalized organic linker. These nets offer unprecedented selectivity towards Xe. Modelling indicates that the selectivity of these nets is tailored by synergy between the pore size and the strong electrostatics afforded by the CrO 4 2− anions.

Mohamed, Mona H.↗

Crack detection in fuel cell electrodes using a spatial filtering technique for overcoming noisy backgrounds

Image processing is a powerful tool that allows for rapid and automated data parsing in settings that occupy large variable spaces and require large data sets. Feature detection on difficultly discerned backgrounds is a subset of image processing that facilitates the extraction of quantitative metrics from otherwise subjective data. Crack detection and quantification is an important capability in polymer electrolyte membrane fuel cell quality control, failure analysis, and optimization. This work presents a technique to perform crack detection and quantification which overcomes challenges faced by commonly used image segmentation techniques. We demonstrate the use of a geometrically filtered noise‐level detection technique to select a binary threshold value from which we then quantify how cracked a sample is. Furthermore, we demonstrate the accuracy of our technique using programmatically generated test images of known crack amounts and their performance on real‐world fuel cell catalyst layer samples.

30 DIRECT ENERGY CONVERSION↗

A projection-based method for topology optimization of structures with graded surfaces

Topology optimization (TO) is a generative design approach that is used to create new structures that are optimal for their purpose. Standard parameterizations of the TOproblem allow exploration of an arbitrarily complex design space, but must be constrained to ensure manufacturability; these constraints tend to be computationally expensive and intrusive to the design process. A relatively new parametrization of the TO problem uses geometry projection of known-manufacturable building blocksinto the design domain, but the existing library of building blocks compatible with projection is small. This project sought to expand this library with new shapes, and to determine whether theaddition of these new shapes could be used to design unit cells for micro-architected materials (MAMs) with improved stiffness-to-weight ratio compared with traditional designs,while retaining compatibility with additive manufacturing processes.Due to a reduction in scope, effort was focused on truss lattices with hollow, tapered, and curved struts. Hollowtruss lattices were found that outperform traditional designs like the octet truss in both stiffness and isotropy, as well as providing a decoupling between the stiffness and relative density. These new designs are expected to improve the performance of functionally graded structures in programmatic applications.

42 ENGINEERING↗

Long-term Biological Monitoring of an Impaired Stream: Synthesis and Environmental Management Implications

The long-term ecological recovery of an impaired stream in response to an industrial facility's pollution abatement actions and the implications of the biological monitoring effort to environmental management is the subject of this special issue of Environmental Management. This final article focuses on the synthesis of the biological monitoring program's components and methods, the efficacy of various biological monitoring techniques to environmental management, and the lessons learned from the program that might be applicable to the design and application of other programs. The focus of the 25-year program has been on East Fork Poplar Creek, an ecologically impaired stream in Oak Ridge, Tennessee with varied and complex stressors from a Department of Energy facility in its headwaters. Major components of the long-term program included testing and monitoring of invertebrate and fish toxicity, bioindicators of fish health, fish contaminant accumulation, and instream communities (including periphyton, benthic macroinvertebrate, and fish). Key parallel components of the program include water chemistry sampling and data management. Multiple lines of evidence suggested positive ecological responses during three major pollution abatement periods. Based on this case study and the related literature, effective environmental management of impaired streams starts with program design that is consistent across space and time, but also adaptable to changing conditions. The biological monitoring approaches used for the program provided a strong basis for assessments of recovery from remedial actions, and the likely causes of impairment. This case study provides a unique application of multidisciplinary and quantitative techniques to address multiple and complex regulatory and programmatic goals, environmental stressors, and remedial actions.

54 ENVIRONMENTAL SCIENCES↗