Search NASA⌕ Search

SEARCH · Search NASA

Results for “prototype buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Cellular Shade Energy Savings in a Commercial Setting

Windows cause approximately 1.7 quad of heating and cooling energy consumption in the United States. This energy consumption can be reduced by using high-efficiency window attachments. Common Venetian blinds and planar shades, such as roller shades, might block solar radiation, but they do not provide a significant improvement to window system thermal transmittance. Cellular shades have better thermal performance compared to other shading devices because of the honeycomb structure that traps air in pockets to create thermal insulation. However, evaluating the energy savings potential of cellular shades using experimental testing in commercial settings is limited. Moreover, the effect of cellular shades on daylighting and glare is yet to be evaluated using field testing. In this study, experimental testing of cellular shades was performed in a real building with emulated occupancy for both a cooling and a heating season. Compared with a room without shades, the use of cellular shades in experimental testing showed incremental energy savings of 4.6% to 9.4% for cooling and higher than 20% for heating. The experimental data were used to calibrate the baseline energy model and validate the cellular shades model. Annual simulation of cellular shades was performed for a medium office prototype building using the validated cellular shades model. The annual simulation was performed in Phoenix, Nashville, and Rochester. The annual savings for HVAC energy was 25% for Phoenix, 27% for Nashville, and 19% for Rochester.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of strategies to meet ASHRAE S241 infectious aerosol control targets by space type and region using EnergyPlus™ simulations

Professional organizations, such as ASHRAE, have recently proposed new voluntary standards for controlling infectious aerosols. Specifically, ASHRAE Standard 241 (S241) defines equivalent clean air targets for a range of space types that can be met through combinations of mitigation measures. This paper seeks to inform the selection of measures by space type and climate zone through building simulations that quantify the impacts of increased outdoor air ventilation; increasing filtration and/or adding germicidal ultraviolet (GUV) in the central heating, ventilation, and air-conditioning (HVAC) systems; or using portable air cleaners (PACs), upper room GUV, or whole room GUV approaches to increase equivalent clean air delivery. The measures are assessed individually and in practical combinations for their ability to meet S241 in four space types (offices, classrooms, dining areas, and healthcare waiting rooms) using prototype buildings modeled using EnergyPlus. The mitigation measures are compared holistically against baseline building operations using metrics for equivalent clean air, energy, and comfort. The results in this study show that single measures can meet S241 for offices with minimal impacts on energy and comfort, while either upper room GUV systems or combinations of measures such as MERV 13 HVAC filtration with PACs are needed to meet S241 for classrooms. The dining area and healthcare waiting room targets cannot be met in this study when assuming design occupancy and MS2 as the challenge agent, even when combining multiple measures together. This paper provides valuable considerations when designing measures to meet S241 for a range of spaces and scenarios.

GUV↗

How will United States commercial building energy use be impacted by IPCC climate scenarios?

Climate change and anthropogenically-forced shift of weather in the future will impact energy use and resilience of both the built environment and the electric grid. The aim of this analysis is to understand how future climate scenarios will impact electricity and natural gas use of commercial buildings in the United States. Here, this study analyzes this impact for 2030, 2045, and 2100 using Representative Concentration Pathways (RCP) scenarios defined in Intergovernmental Panel on Climate Change (IPCC) Assessment Report 5. The large, gridded simulation of meteorological variables for RCPs 2.6, 4.5, 6.0, and 8.5 are selected and downscaled to make available hourly Future Meteorological Year (FMY) weather files for use and improvement in subsequent studies. High performance computing resources use these FMYs to simulate commercial prototype buildings in every American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) climate zone of the United States (US), and results are scaled to nation-wide energy use using conditioned floor area multipliers. The analysis is conducted without speculating the physical and performance traits of future buildings or the grid characteristics. This analysis quantifies the impact of climate change on source electrical and natural gas usage for commercial buildings in the United States over the next 80 years. If US commercial floorspace remained constant, total energy use by 2100 is predicted between an 1.75% decrease under the greatest emission scenario (8.5) and a 1.76% increase under the lowest emission scenario (2.6). When adjusted for anticipated urban growth by 2100, the predicted range is 65% increase (8.5) and 71% increase (2.6). Under a global temperature rise climate scenario, the warmest US climate zones will see a large increases in electricity use derived from space cooling while the coldest US climate zones will see significant decreases in natural gas use caused by the decrease in heating necessary. While climate change may ultimately require adaptations of the built environment to withstand its effects and because the United States is a country that requires more heating than cooling, from a building energy perspective, climate change (average temperature rise) is a net energy saver for the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Modeling Framework to Support Control Investigations of Sailcraft Missions A First Cut: ABLE Sailcraft Dynamics Model

Solar Sailcraft, the stuff of dreams of the H.G. Wells generation, is now a rapidly maturing reality. The promise of unlimited propulsive power by harnessing stellar radiation is close to realization. Currently, efforts are underway to build, prototype and test two configurations. These sails are designed to meet a 20m sail requirement, under guidance of the In-Space Propulsion (ISP) technology program office at MSFC. While these sails will not fly , they are the first steps in improving our understanding of the processes and phenomena at work. As part of the New Millennium Program (NMP) the ST9 technology validation mission hopes to launch and fly a solar sail by 2010 or sooner. Though the Solar Sail community has been studying and validating various concepts over two decades, it was not until recent breakthroughs in structural and material technology, has made possible to build sails that could be launched. With real sails that can be tested (albeit under earth conditions), the real task of engineering a viable spacecraft has finally commenced. Since it is not possible to accurately or practically recreate the actual operating conditions of the sailcraft (zero-G, vacuum and extremely low temperatures), much of the work has focused on developing accurate models that can be used to predict behavior in space, and for sails that are 6-10 times the size of currently existing sails. Since these models can be validated only with real test data under "earth" conditions, the process of modeling and the identification of uncertainty due to model assumptions and scope need to be closely considered. Sailcraft models that exist currently, are primarily focused on detailed physical representations at the component level, these are intended to support prototyping efforts. System level models that cut across different sail configurations and control concepts while maintaining a consistent approach are non-existent. Much effort has been focused on the areas of thrust performance, solar radiation prediction, and sail membrane behavior vis-a-vis their reflective geometry, such as wrinkling/folding/furling as it pertains to thrust prediction. A parallel effort has been conducted on developing usable models for developing attitude control systems (ACS), for different sail configurations in different regimes. There has been very little by way of a system wide exploration of the impact of the various control schemes, thrust prediction models for different sail configurations being considered.

Sarathy, Sriprakash↗

Translating climate change and heating system electrification impacts on building energy use to future greenhouse gas emissions and electric grid capacity requirements in California

Climate change and increased electrification of space and water heating in buildings can significantly affect future electricity demand and hourly demand profiles, which has implications for electric grid greenhouse gas emissions and capacity requirements. We use EnergyPlus to quantify building energy demand under historical and under several climate change projections of 32 kinds of building prototypes in 16 different climate zones of California and imposed these impacts on a year 2050 electric grid configuration by simulation in the Holistic Grid Resource Integration and Deployment (HIGRID) model. We find that climate change only prompted modest increases in grid resource capacity and negligible difference in greenhouse gas emissions since the additional electric load generally occurred during times with available renewable generation. Heating electrification, however, prompted a 30-40% reduction in greenhouse gas emissions but required significant grid resource capacity increases, due to the higher magnitude of load increases and lack of readily available renewable generation during the times when electrified heating loads occurred. Overall, this study translates climate change and electrification impacts to system-wide endpoint impacts on future electric grid configurations and highlights the complexities associated with translating building-level impacts to electric system-wide impacts.

54 ENVIRONMENTAL SCIENCES↗

Analyzing the Impact of Future Weather Data on Energy Consumption in Weatherization Assistant

This study supports the mission of the U.S. Department of Energy’s Weatherization Assistance Program (WAP), which aims to increase the energy efficiency of dwellings and reduce their total residential expenditures. Specifically, we examine how projected future climate conditions may affect residential building energy performance by integrating future weather data into the National Energy Audit Tool (NEAT). Since WAP evaluates the cost-effectiveness of retrofit measures over lifespans of up to 30 years, accounting for evolving climate conditions is increasingly important. To reflect future household energy demands, this study replaces historically based Typical Meteorological Year (TMY3) weather inputs with Future Typical Meteorological Year (fTMY) datasets derived from global climate model (GCM) projections. A simulation-based framework was established to enable NEAT analysis under future weather conditions. This workflow involves converting EPW-format weather files into JSON inputs compatible with NEAT and generating degree-hour metrics needed for load calculations. The fTMY dataset used in this study was developed by Oak Ridge National Laboratory through downscaling of six GCMs under different emission scenarios and covers the period from 2020 to 2100. In contrast, the TMY3 dataset is based on historical weather data from 1961 to 1990. Simulations were conducted for benchmark single-family prototype buildings across ASHRAE climate zones 1–7, which cover all regions of the U.S. except the subarctic Zone 8 in northern Alaska, evaluating both heating and cooling loads under TMY3 and fTMY conditions. Four foundation types were tested, while heating systems were standardized, as NEAT does not differentiate thermal energy load by HVAC system type in its load calculations. Results show that fTMY weather input consistently yield lower heating loads and higher cooling loads across most locations, aligning with expected climate warming trends. Notably, colder regions such as zones 6A, 6B, and 7 experience marked reductions in heating load, while warmer and transitional zones, such as 2A (Lufkin, TX) and 3C (San Francisco, CA), have substantial increases in cooling loads. Although this study does not directly assess the performance of retrofit measures under future climate conditions, it provides a critical foundation for doing so. By quantifying shifts in baseline (i.e., pre-retrofit case) energy loads between historical and future weather files, the study highlights the importance of integrating climate-responsive data into audit tools. These findings will inform future efforts to evaluate the long-term effectiveness and cost-effectiveness of weatherization measures under changing climate conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Research and Development for Off-Road Fuel Cell Applications U.S. Department of Energy Grant DE-FG36-04GO14303 - Final Report

Off-road concerns are related to the effects of shock and vibration and air quality on fuel cell power requirements. Mechanical stresses on differing material makeup and mass distribution within the system may render some components susceptible to impulse trauma while others may show adverse effects from harmonic disturbances or broad band mechanical agitation. One of the recognized challenges in fuel cell systems air purification is in providing a highly efficient particulate and chemical filter with minimal pressure drop. PEM integrators do not want additional parasitic loads added to the system as compensation for a highly efficient yet highly restrictive filter. Additionally, there is challenge in integrating multiple functions into a single air intake module tasked with effectively filtering high dust loads, diesel soot, pesticides, ammonias, and other anticipated off-road contaminants. This project has investigated both off-road associated issues cumulating in the prototype build and testing of two light duty off-road vehicles with integrated fuel cell power plant systems.

08 HYDROGEN↗

Energy Storage and Generation for Extreme Temperature and Pressure and Directional Measurement While Drilling Applications

FastCAP Systems Corporation has successfully completed all milestones defined by the award DE-EE0005503. Under this program, FastCAP developed three critical subassemblies to TRL3 demonstrating proof of concept of a geothermal MWD power source. This power source includes an energy harvester, electronics and a novel high temperature ultracapacitor (“ultracap”) rechargeable energy storage device suitable for geothermal exploration applications. FastCAP’s ruggedized ultracapacitor (ultracap) technology has been proven and commercialized in oil and gas exploration operating to rated temperatures of 150°C. Characteristics of this technology are that it is rechargeable and relatively high power. This technology was the basis for the advancements in rechargeable energy storage under this project. The ultracap performs reliably at 250°C and beyond and operates over a wide operating temperature range: -5°C to 250°C. The ultracap has significantly higher power density than lithium thionyl chloride batteries, a non-rechargeable incumbent used in oil and gas drilling today. Several hermetically sealed, prototype devices were tested in our laboratories at constant temperatures of 250°C showing no significant degradation over 2000 hours of operation. Other prototypes were tested at Sandia National Lab in the month of April, 2015 for a third party performance validation. These devices showed outstanding performance over 1000 hours of operation at three rated temperatures, 200°C, 225°C and 250°C, with negligible capacitance degradation and minimal equivalent series resistance (ESR) increase. Similarly, FastCAP’s ruggedized electronics have been proven and commercialized in oil and gas exploration operating to rated temperatures of 150°C. This technology was the basis for the advancements in downhole electronics under this project. Principal contributions here focused on design for manufacture innovations that have reduced the prototype build cycle time by a factor of 10x. The electronics have demonstrated a substantially reduced design cycle time by way of process and material selection innovations and have been qualified for 250°C / 10 Grms for at least 200 hours. FastCAP has also invented a rotary inertial energy generator (RIEG) to harvest various mechanical energy sources that exist downhole. This device is flow-independent and has been demonstrated as a proof of concept to survive geothermal well temperatures under this project. The herein energy harvester has been developed to provide operational power by harvesting rotational mechanical energy that exists downhole in geothermal drilling. The energy harvester has been tested at 250°C / 10 Grms for 200 hours. Deployment of these technologies in geothermal drilling and exploration applications could have an immediate and significant impact on the effectiveness and efficiency of drilling processes, particularly with regard to use of advanced logging and monitoring techniques. The ultimate goal of this work is to reduce drilling risk to make geothermal energy more attractive and viable to the customer. Generally speaking, we aim to support the transfer of MWD techniques from oil and gas to geothermal exploration with considerations toward the practical differences between the two. One of the most significant obstacles to the deployment of advanced drilling and production techniques in the geothermal context are limitations related to the maximum operating temperatures of downhole batteries used to provide power for downhole sensors, steering tools, telemetry equipment and other MWD/LWD technologies. FastCAP’s higher temperature ultracapacitor technology will provide power solutions for similar advanced drilling and production techniques, even in the harsher environments associated with geothermal energy production. This ultracapacitor will enable downhole power solutions for the geothermal industry capable of the same reliable and safe operation our team has demonstrated in the oil and gas context. Without batteries, geothermal MWD is left without a downhole power source. Some very high temperature turbines exist but provide unsteady, intermittent power and no power when the flow is off. In high loss formations common to geothermal exploration, it will be auspicious to support air drilling in which case there is no flow to power a turbine at all. In the best case, rechargeable energy storage will help to buffer unsteady power from non-battery power sources and in the worst case it will be needed to store energy from highly intermittent sources to provide a continuously operable power source to the tool.

15 GEOTHERMAL ENERGY↗

“A System for Automatically Maintaining Pressure in a Commercial Truck Tire”

Under-inflated tires significantly reduce a vehicle’s fuel efficiency by increasing rolling resistance (drag force). The Air Maintenance Technology (“AMT”) system developed through this project replenishes lost air and maintains optimal tire cavity pressure whenever the tire is rolling in service, thus improving overall fuel economy by reducing the tire’s rolling resistance. The system consists of an inlet air filter, an air pump driven by tire deformation during rotation, and a pressure regulating device. Pressurized air in the tire cavity naturally escapes by diffusion through the tire and wheel, leaks in tire seating, and through the filler valve and its seating. As a result, tires require constant maintenance to replenish lost air. Since manual tire inflation maintenance is both labor intensive and time consuming, it is frequently overlooked or ignored. By automating the maintenance of optimal tire pressure, the tire’s contribution to the vehicle’s overall fuel economy can be maximized. The work was divided into three phases. The objectives of Phase 1, Planning and Initial Design, resulted in an effective project plan and to create a baseline design. The objectives for Phase 2, Design and Process Optimization, were: to identify finalized design for the pump, regulator and filter components; identify a process to build prototype tires; assemble prototype tires; test prototype tires and document results. The objectives of Phase 3, Design Release and Industrialization, were to finalize system tire assembly, perform release testing and industrialize the assembly process.

42 ENGINEERING↗

Modular Hydropower Engineering and Pilot Scale Manufacturing

Emrgy has developed, prototyped and tested a modular hydropower system for renewable energy generation. ORNL worked with Emrgy to demonstrate the use of additive manufacturing in the production of the hydrofoils and spokes for the hydrokinetic system. Specifically, during Phase 1 of this effort, ORNL printed and finished machined patterns for both the hydrofoils and spokes that were subsequently used in a sand casting manufacturing process. Emrgy utilized the sand castings for a pilot installation in Denver, CO, where the parts represented an 80% cost savings from the previous prototype build that was manufactured using subtractive manufacturing. In addition, the castings were completed with ORNL’s newly developed AlCeMg alloy that will be tested for performance improvements including higher corrosion resistance in a water application than the 6160 alloy used previously

13 HYDRO ENERGY↗

Design and Field Testing of Manufacturable Advanced Low-Cost Receiver for Parabolic Trough Solar Power

This project addresses the 30-yr service life, ease of manufacturability for low cost, and low Operations and Maintenance (O&M) costs for our novel parabolic trough receiver, SunTrap. Current trough-based commercial power plants operate at 400°C or below, in part due to poor performance and lifetime of existing receivers at higher temperatures. Thermal losses from such receivers are dominated by radiation; by the Stefan- Boltzmann law, radiative losses have a component that scales as T 4, challenging high-temperature efficiency. Our novel SunTrap receiver offers increased reliability by eliminating the need to operate in a vacuum, while improving performance at higher temperatures by using high-performance insulation on exposed sections of the receiver that absorb negligible solar flux. As a result, SunTrap offers comparable optical efficiency to currently available technology while reducing thermal losses at higher temperatures. In this project, our novel receiver and all subcomponents have been designed to be compatible with molten salts to enable operation at next generation trough-based exit temperatures between 500 and 550°C. Norwich Technologies, with collaborators from Creare, Thermodyne, Solar Dynamics (previously Abengoa Solar), and the University of Louisiana – Lafayette successfully iterated the design of the SunTrap receiver through a series of modelling efforts, cost analyses, prototype builds, and performance and lifetime tests to minimize the levelized cost of energy (LCOE). The final design (1) realized predicted receiver performance in a series of field optical efficiency, laboratory thermal efficiency and freeze/thaw recovery tests, (2) optimized the receiver with respect to integration with standard collector systems, receiver-to-receiver connections, and receiver-to-mirror connections, (3) demonstrated 30-yr service life of receiver and all components of the receiver, (4) developed commercialization and manufacturing plans to enable rapid deployment, and (5) demonstrated durability of an air-stable solar-selective coating. NT’s disruptive technology marshals diverse advances in design, materials and coatings to revolutionize key aspects of the CSP trough solar field. By enabling significant operational and cost advances, this technology offers potential decreases in LCOE of over 20% compared to traditional parabolic trough systems.

14 SOLAR ENERGY↗

Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010

This report documents the progress indicator (PI) process and analysis that Pacific Northwest National Laboratory (PNNL) developed to evaluate the potential energy savings from the application of ASHRAE Standard 90.1-2010 to building design and construction compared to the application of ASHRAE Standard 90.1-2004. The report describes PNNL’s EnergyPlus simulation framework, and the building prototype simulation models. The combined upgrades from ASHRAE Standard 90.1 -2004 to ASHRAE Standard 90.1-2010 are described, and consist of a total of 153 approved addenda (44 addenda to ASHRAE Standard 90.1-2007 and 109 addenda to ASHRAE Standard 90.1-2010). PNNL reviewed and considered all 153 addenda for quantitative analysis in the PI process. Fifty-three of those addenda are included in the quantitative analysis. This report provides information on the categorization of all of the addenda, a summary of the content, and a more in-depth explanation of the impact and modeling of the 53 identified addenda and their quantitative savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Price-Informed Operation of a Battery Storage System in an Office Building

New prescriptive efficiency requirements amended to US model energy codes historically have been evaluated using an average, blended electricity rate, which obscures demand charges. Post 2019, new measures can be evaluated using a representative time-of-use (TOU) tariff yet more sophisticated analysis methods are needed to consider a variety of TOU tariffs and assess price-informed control. To address these needs, this study couples building prototype simulation model with varying-in-sophistication battery storage operating strategies for different electricity TOU tariffs. The analysis compares the impact of operating a battery storage system following simpler rule-of-thumb methods versus a semi-optimized priced-informed heuristic approach. The investigation demonstrates that the heuristic approach results in greater electricity cost savings and is practical to implement.

Lei, Xuechen↗

Heavy-Duty Nonroad Material Handler Electrification Part 1: Real-World Drive Cycle Development

Knowing a detailed operating cycle is critical for developing and testing equipment. Operating cycles can be separated by two clear distinctions: (1) regulatory or non-regulatory and (2) application at the engine-only or full machine level. The Environmental Protection Agency’s (EPA) Nonroad Transient Cycle (NRTC) may be a good representation of engine use in many types of equipment, but there is a gap in standardized and validated drive cycles specifically for nonroad material handlers. Lacking a standardized drive cycle makes it difficult to accurately benchmark machine performance and validate new powertrain technologies. The objective of this investigation is to illustrate the development of a custom drive cycle augmented with real-world customer use data that serves multiple purposes: (1) understand the range of operation and utilization that formulated inputs for electrified architecture analysis and (2) develop a repetitive and consistent maneuver to establish baseline energy consumption enabling equivalent comparison to future electrified prototype builds. This article presents a solution specifically for a 23-ton nonroad material handler in which material handling, machine transport, and extended idle were homologated to form representative short cycles defined by machine velocity and hydraulic cylinder position. The most intensive material handling short cycles had a load factor of 40% and an average fuel rate of 16 L/h. Combined with a visual aid, the short cycles exhibited low variability, having less than 5% root mean square (RMS) error in lift and reach position with respect to the average. The machine’s performance on these short cycles at the Advanced Power Systems Research Center (APSRC) was compared to results from two real-world customer locations operating the instrumented test machine in a cyclical manner, and for similar ground conditions were found to be comparable in fuel consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical and classical analysis of V/STOL aircraft using selected propulsion systems

The development needed for the evolution of selected V/STOL research vehicles into optimized antisubmarine warfare (ASW) aircraft configurations, using numerical procedures and traditional analytical methods, has been examined. Three propulsion systems, which represent state-of-the-art development aimed at solving the thrust-vectoring and attitude-control problems of V/STOL aircraft, are analyzed. The use of NASA computer programs for aircraft synthesis (ACSYNT), and for optimizing configurations (COMMIN), coupled with contractor-supplied propulsion system data provides for accurate performance prediction of the selected ASW configurations. Particular emphasis on the transition phase between the research vehicle and the optimized configuration demonstrates the strengths and weaknesses of using generic research aircraft instead of building prototypes to demonstrate new technology

Wilson, S. B., III↗

Designing Cool Components

A NASA SBIR contract served as the beginning for the development of Daat Research Corporation's Coolit software. Coolit is a unique computational fluid dynamics (CFD) application aimed at thermal and cooling design problems. Coolit can generate 3-D representations of the thermofluid environment and "sketch" the component on the computer. The software modeling reduces time and effort in prototype building and testing.

Source record↗

Dropping in on Mars

Here I was: 26 years old, I had never worked on a flight project before, and all eyes were on me. Every time I walked by the Pathfinder project office, Tony Spear, the project manager, would throw his arm around me and announce, 'Hey everybody, the whole mission is riding on this guy right here.' Our task was to design and build airbags for Pathfinder s landing on Mars - an approach that had never been used on any mission. Airbags may seem like a simple, low-tech product, but it was eye-opening to discover just how little we knew about them. We knew that the only way to find out what we needed to learn was to build prototypes and test them. We just didn t know how ignorant we were going to be. Airbags seemed like a crazy idea to a lot of people. Nobody ever said that, mind you, but there seemed to be a widespread feeling that the airbags weren t going to work. 'We ll let you guys go off and fool around until you fall flat on your faces.' That was the unspoken message I received day after day.

Rivellini, Tommaso P.↗

Implementation of an Antenna Array Signal Processing Breadboard for the Deep Space Network

The Deep Space Network Large Array will replace/augment 34 and 70 meter antenna assets. The array will mainly be used to support NASA's deep space telemetry, radio science, and navigation requirements. The array project will deploy three complexes in the western U.S., Australia, and European longitude each with 400 12m downlink antennas and a DSN central facility at JPL. THis facility will remotely conduct all real-time monitor and control for the network. Signal processing objectives include: provide a means to evaluate the performance of the Breadboard Array's antenna subsystem; design and build prototype hardware; demonstrate and evaluate proposed signal processing techniques; and gain experience with various technologies that may be used in the Large Array. Results are summarized..

array↗