Search NASA⌕ Search

SEARCH · Search NASA

Results for “purity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Effect of Rest Periods on Fatigue of High-Purity Aluminum

The effect of rest periods on the fatigue life of high-purity aluminum was investigated under two conditions. In one the specimens were tested at elevated temperatures and the rest periods were given at room temperature; in the second the specimens were tested at room temperature and the rest periods were given at elevated temperature. The results obtained indicated that the increase of life was negligible in the first condition, but an increase of life may be obtained in the second. In order to check this increase in fatigue life a second series of tests has been carried out on a different lot of specimens and again an increase in life was found. This increase of life appeared to be from 30 to 60 percent from the average of the results of 20 tests for each test condition.

Berry, J. W.↗

Realization of Ultra-High Spectral Purity with the Opto-Electronic Oscillator

Recent results with the Opto-Electronic Oscillator (OEO) have led to the realization of very high spectral purity. Experimental results have produced a performance characterized by a noise as low as by -50 dBc/Hz at 10 Hz for a 10 GHz OEO. The unit was built in a compact package containing an integrated DFB laser and the modulator. This performance is significant because the oscillator is free running, and since the noise in an OEO is independent of the oscillation frequency, the same result can also be obtained at higher frequencies. The result also demonstrates that high frequency, high performance, low cost, and miniature OEO can be realized with the integrated photonic technology. We have also developed a novel carrier suppression technique to reduce the 1/f phase noise of the oscillator even further. The technique is based on the use of a long fiber delay, in place of the high Q cavity, to implement carrier suppression. Our preliminary experimental results indicate an extra 10 to 20 dB phase noise reduction of the OEO with this novel technique. Further noise reduction beyond this value is expected with improved circuit design and longer reference fiber.

Yao, Steve↗

High-Purity Aluminum Magnet Technology for Advanced Space Transportation Systems

Basic research on advanced plasma-based propulsion systems is routinely focused on plasmadynamics, performance, and efficiency aspects while relegating the development of critical enabling technologies, such as flight-weight magnets, to follow-on development work. Unfortunately, the low technology readiness levels (TRLs) associated with critical enabling technologies tend to be perceived as an indicator of high technical risk, and this, in turn, hampers the acceptance of advanced system architectures for flight development. Consequently, there is growing recognition that applied research on the critical enabling technologies needs to be conducted hand in hand with basic research activities. The development of flight-weight magnet technology, for example, is one area of applied research having broad crosscutting applications to a number of advanced propulsion system architectures. Therefore, NASA Marshall Space Flight Center, Louisiana State University (LSU), and the National High Magnetic Field Laboratory (NHMFL) have initiated an applied research project aimed at advancing the TRL of flight-weight magnets. This Technical Publication reports on the group's initial effort to demonstrate the feasibility of cryogenic high-purity aluminum magnet technology and describes the design, construction, and testing of a 6-in-diameter by 12-in-long aluminum solenoid magnet. The coil was constructed in the machine shop of the Department of Physics and Astronomy at LSU and testing was conducted in NHMFL facilities at Florida State University and at Los Alamos National Laboratory. The solenoid magnet was first wound, reinforced, potted in high thermal conductivity epoxy, and bench tested in the LSU laboratories. A cryogenic container for operation at 77 K was also constructed and mated to the solenoid. The coil was then taken to NHMFL facilities in Tallahassee, FL. where its magnetoresistance was measured in a 77 K environment under steady magnetic fields as high as 10 T. In addition, the temperature dependence of the coil's resistance was measured from 77 to 300 K. Following this series of tests, the coil was transported to NHMFL facilities in Los Alamos, NM, and pulsed to 2 T using an existing capacitor bank pulse generator. The coil was completely successful in producing the desired field without damage to the windings.

Goodrich, R. G.↗

Measured Attenuation of Coplanar Waveguide on 6H, p-type SiC and High Purity Semi-Insulating 4H SiC through 800 K

Wireless sensors for high temperature applications such as oil drilling and mining, automobiles, and jet engine performance monitoring require circuits built on wide bandgap semiconductors. In this paper, the characteristics of microwave transmission lines on 4H-High Purity Semi-Insulating SiC and 6H, p-type SiC is presented as a function of temperature and frequency. It is shown that the attenuation of 6H, p-type substrates is too high for microwave circuits, large leakage current will flow through the substrate, and that unusual attenuation characteristics are due to trapping in the SiC. The 4H-HPSI SiC is shown to have low attenuation and leakage currents over the entire temperature range.

Ponchak, George E.↗

Enhanced quantum efficiency of high-purity silicon imaging detectors by ultralow temperature surface modification using Sb doping

A low temperature process for Sb doping of silicon has been developed as a backsurface treatment for high-purity n-type imaging detectors. Molecular beam epitaxy (MBE) is used to achieve very high dopant incorporation in a thin, surface-confined layer. The growth temperature is kept below 450 (deg)C for compatibility with Al-metallized devices. Imaging with MBE-modified 1kx1k charge coupled devices (CCDs) operated in full depletion has been demonstrated. Dark current is comparable to the state-of-the-art process, which requires a high temperature step. Quantum efficiency is improved, especially in the UV, for thin doped layers placed closer to the backsurface. Near 100% internal quantum efficiency has been demonstrated in the ultraviolet for a CCD with a 1.5 nm silicon cap layer.

charged coupled devices (CCDs)↗

Delta-Doped High Purity Silicon UV-NIR CCDs with High QE and Low Dark Current

Delta doping process was developed on p-channel CCDs for MIDEX-Orion and JDEM/SNAP and was applied to large format (2k x4k) CCDs. Delta doping is applied to fully-fabricated CCDs (complete with Al metallization). High QE and low dark current is demonstrated with delta doped p-channel CCDs. In-house AR coating is demonstrated. Advantages include: Delta doping enables high QE and stability across the entire spectral range attainable with silicon. Delta doping is a low temperature process and is compatible with fully-fabricated detector arrays. Same base device for Orion two channels. High radiation tolerance and no thinning requirements of high purity p-channel. CCDs are additional advantages.

Orion↗

Process for the production of ultrahigh purity silane with recycle from separation columns

Tri- and dichlorosilanes formed by hydrogenation in the course of the reaction of metallurgical silicon, hydrogen and recycle silicon tetrachloride are employed as feed into a separation column arrangement of sequential separation columns and redistribution reactors which processes the feed into ultrahigh purity silane and recycle silicon tetrachloride. A slip stream is removed from the bottom of two sequential columns and added to the recycle silicon tetrachloride process stream causing impurities in the slip streams to be subjected to reactions in the hydrogenation step whereby waste materials can be formed and readily separated.

Coleman, Larry M.↗

The Atacama Cosmology Telescope: Physical Properties and Purity of a Galaxy Cluster Sample Selected Via the Sunyaev-Zel'Dovich Effect

We present optical and X-ray properties for the first confirmed galaxy cluster sample selected by the Sunyaev-Zel'dovich Effect from 148 GHz maps over 455 square degrees of sky made with the Atacama Cosmology Telescope. These maps. coupled with multi-band imaging on 4-meter-class optical telescopes, have yielded a sample of 23 galaxy clusters with redshifts between 0.118 and 1.066. Of these 23 clusters, 10 are newly discovered. The selection of this sample is approximately mass limited and essentially independent of redshift. We provide optical positions, images, redshifts and X-ray fluxes and luminosities for the full sample, and X-ray temperatures of an important subset. The mass limit of the full sample is around 8.0 x 10(exp 14) Stellar Mass. with a number distribution that peaks around a redshift of 0.4. For the 10 highest significance SZE-selected cluster candidates, all of which are optically confirmed, the mass threshold is 1 x 10(exp 15) Stellar Mass and the redshift range is 0.167 to 1.066. Archival observations from Chandra, XMM-Newton. and ROSAT provide X-ray luminosities and temperatures that are broadly consistent with this mass threshold. Our optical follow-up procedure also allowed us to assess the purity of the ACT cluster sample. Eighty (one hundred) percent of the 148 GHz candidates with signal-to-noise ratios greater than 5.1 (5.7) are confirmed as massive clusters. The reported sample represents one of the largest SZE-selected sample of massive clusters over all redshifts within a cosmologically-significant survey volume, which will enable cosmological studies as well as future studies on the evolution, morphology, and stellar populations in the most massive clusters in the Universe.

Menanteau, Felipe↗

Spectroscopic Determination of Trace Contaminants in High-Purity Oxygen

Oxygen used for extravehicular activities (EVAs) must be free of contaminants because a difference in a few tenths of a percent of argon or nitrogen content can mean significant reduction in available EVA time. These inert gases build up in the extravehicular mobility unit because they are not metabolized or scrubbed from the atmosphere. A prototype optical emission technique capable of detecting argon and nitrogen below 0.1% in oxygen has been developed. This instrument uses a glow discharge in reduced-pressure gas to produce atomic emission from the species present. Because the atomic emission lines from oxygen, nitrogen, and argon are discrete, and in many cases well-separated, trace amounts of argon and nitrogen can be detected in the ultraviolet and visible spectrum. This is a straightforward, direct measurement of the target contaminants, and may lend itself to a device capable of on-orbit verification of oxygen purity. A glow discharge is a plasma formed in a low-pressure (1 to 10 Torr) gas cell between two electrodes. Depending on the configuration, voltages ranging from 200 V and above are required to sustain the discharge. In the discharge region, the gas is ionized and a certain population is in the excited state. Light is produced by the transitions from the excited states formed in the plasma to the ground state. The spectrum consists of discrete, narrow emission lines for the atomic species, and broader peaks that may appear as a manifold for molecular species such as O2 and N2, the wavelengths and intensities of which are a characteristic of each atom. The oxygen emission is dominated by two peaks at 777 and 844 nm.

Hornung, Steven↗

Use of Aquaporins to Achieve Needed Water Purity On ISS for the EMU Space Suit System

Use of Aquaporins to Achieve Needed Water Purity On ISS for the EMU Space Suit System. With the U.S. Space Shuttle fleet retired, the supply of extremely high-quality water "super-Q" - required for the EMU Space suit cooling on this ISS - will become a significant operational hardware challenge in the very near future. A proposed potential solution is the use of a filtration system consisting of a semi-permeable membrane embedded with aquaporin proteins. Aquaporins are a special class of trans-membrane proteins that facilitate passive transport of water and other substances across a membrane. The specificity of these proteins is such that only water is allowed through the protein structure, and this novel property invites their adaptation for use in water filtration systems, specifically usage on the ISS for the EMU space suit system. These proteins are found in many living systems and have been developed for commercial use today.

Hill, Terry↗

Dielectric Performance of High Purity HTCC Alumina at High Temperatures - A Comparison Study with Other Polycrystalline Alumina

A very high purity (99.99+) high temperature co-fired ceramic (HTCC) alumina has recently become commercially available. The raw material of this HTCC alumina is very different from conventional HTCC alumina, and more importantly there is no glass additive in this co-fired material. Previously, selected HTCC and LTCC (low temperature co-fired ceramic) alumina materials were evaluated at high temperatures as dielectric and compared to a regularly sintered 96 polycrystalline alumina (96 Al2O3), where 96 alumina was used as the benchmark. A prototype packaging system based on regular 96 alumina with Au thick-film metallization successfully facilitated long term testing of high temperature silicon carbide (SiC) electronic devices for over 10,000 hours at 500C. In order to evaluate this new HTCC alumina for possible high temperature packaging applications, the dielectric properties of this HTCC alumina substrate were measured and compared with those of 96 alumina and a LTCC alumina from room temperature to 550C at frequencies of 120 Hz, 1 KHz, 10 KHz, 100 KHz, and 1 MHz. A parallel-plate capacitive device with dielectric of the HTCC alumina and precious metal electrodes were used for measurements of the dielectric constant and dielectric loss of the co-fired alumina material in the temperature and frequency ranges. The capacitance and AC parallel conductance of the capacitive device were directly measured by an AC impedance meter, and the dielectric constant and parallel AC conductivity of the dielectric were calculated from the capacitance and conductance measurement results. The temperature and frequency dependent dielectric constant, AC conductivity, and dissipation factor of the HTCC alumina substrate are presented and compared to those of 96 alumina. Other technical advantages of this new co-fired material for possible high packaging applications are also discussed.

High temperature↗

Infrared Properties of High-Purity Silicon

High-purity silicon is a readily available material of utility in realizing a variety of long-wavelength optical and guided wave components. The transmittance of uncompensated for silicon is measured in the far- and mid-infrared regimes at room and cryogenic temperatures. The experimental and analysis techniques used to extract the refractive index from 100-1000 per cm (100–10µm) are presented, and the results are compared to the literature. An average refractive index below 300 per cm, n̂(300 K)=3.417 + i 8.9 x10(exp -5), which transitions in cooling to n̂(10 K)=3.389 + i 4.9 x 10(exp -6), is observed.

Edward J. Wollack↗

Effect of Reactant Purity on Proton Exchange Membrane Fuel Cell Performance

NASA has set a goal to return to the Moon and to establish a sustained lunar presence. Many applicable lander and upperstage vehicle concepts utilize cryogenic H2 and O2 propellants. This propellant selection enables appealing potential mission concepts wherein electricity is generated by operating a fuel cell on residual H2 and O2 propellants. This concept depends on the capability of the fuel cell to utilize dry, propellant-grade reactants with concentrations of up to 30 percent He present. This study consists of the evaluation of a 12-cell non-flow-through proton exchange membrane fuel cell stack of 50 sq. cm active area with passive water removal. This stack was supplied with three levels of reactant purity: >99.999, 99.1, and 70 mol%, with the remainder made up of He. The reactant humidity and flow-through rate were also assessed as performance factors, and the fuel stack repeatedly supported a load profile with current densities up to 500 mA/sq. cm (25 A). The fuel cell performed consistently over the course of testing, with cell voltages decreasing approximately 50 mV at the maximum current density when supplied with reactants with 30 percent He present.

electrochemistry↗

Enhanced quantum efficiency of high-purity silicon imaging detectors by ultralow temperature surface modification using Sb doping

A low temperature process for Sb doping of silicon has been developed as a backsurface treatment for high-purity n-type imaging detectors. Molecular beam epitaxy (MBE) is used to achieve very high dopant incorporation in a thin, surface-confined layer. The growth temperature is kept below 450 °C for compatibility with Al-metallized devices. Imaging with MBE-modified 1kx1k charge coupled devices ((CCDs) operated in full depletion has been demonstrated. Dark current is comparable to the state-of-the-art process, which requires a high temperature step. Quantum efficiency is improved, especially in the UV, for thin doped layers placed closer to the backsurface. Near 100% internal quantum efficiency has been demonstrated in the ultraviolet for a CCD with a 1.5 nm silicon cap layer.

Nikzad, Shouleh↗

Ultrapure Water System at JSC for High Purity Cleaning of Flight Hardware, Astromaterial Handling Tools and Solar Wind Samples

Use of Ultrapure Water (UPW) for cleaning of astromaterial sample handling tools and containers was driven by the discontinuation of Freon 113 as a cleaning solvent, due to environmental concerns. Freon 113, recycled using distillation, was very effective at removing organic residues from sample handling hardware. The initial switch to high purity water for astromaterial tool cleaning was modeled after efforts at White Sands Test Facility (WSTF) and current semiconductor UPW production practices in the early 1990s. JSC curation’s first system was comprised of ion exchange polishing cylinders, 55 gallon PVDF-lined storage tank, a few tens of feet of PVDF piping, UV and particle filtration, and this system supported cleaning for lunar, meteorite and Cosmic Dust collectors lab operations. By 2000 a major expansion and upgrade was providing UPW of quality E-1 (ASTM D5127-90) or better at 10 gpm for cleaning of the Genesis solar wind payload for flight, in addition to sample handling tools for other astromaterials. This expansion included a 1000 gallon storage tank and several hundred feet of PVDF piping located in B. 31 and 31N. An extra reverse osmosis process unit was added to incoming water in 2005. Subsequently several major components were replaced, and in anticipation of adding new labs, an enlarged UPW system was designed in 2018 and completed in 2019. This system produces grade E1.1 UPW at 15 gpm in a continuous 1100 ft. loop with 5000 gal. storage tank, supplying 8 laboratories.

Ultrapure water↗