Search NASA⌕ Search

SEARCH · Search NASA

Results for “pyrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development of advanced Czochralski growth process to produce low cost 150 kg silicon ingots from a single crucible for technology readiness

Six growth runs used the Kayex-Hameo Automatic Games Logic (AGILE) computer based system for growth from larger melts in the Mod CG2000. The implementation of the melt pyrometer sensor allowed for dip temperature monitoring and usage by the operator/AGILE system. Use of AGILE during recharge operations was successfully evaluated. The tendency of crystals to lose cylindrical shape (spiraling) continued to be a problem. The hygrometer was added to the Furnace Gas Analysis System and used on several growth runs. The gas chromatograph, including the integrator, was also used for more accurate carbon monoxide concentration measurements. Efforts continued for completing the automation of the total Gas Analysis System. An economic analysis, based on revised achievable straight growth rate, is presented.

Lane, R. L.↗

Shock-wave properties and high-pressure equations of state of geophysically important materials

Shock wave (Hugoniot), shock temperature, and release data are presented for several geophysically important, refractory materials. A sensitive multichannel optical pyrometer was developed to measure shock temperatures (2500 to 5600 K at pressures from 48 to 117 GPa) in anorthite (CaAl2Si2O8) glass. Shock temperatures of 3750 to 6000 K at pressures from 140 to 182 GPa were measured in calcium oxide (CaO). Temperature data were used to constrain the energetics of the B1-B2 phase transition at 70 GPa in CaO, and to construct a finite strain equation of state for CaO consistent with previous Hugoniot data. The CaO equation of state was used with equation of state parameters of other oxides to construct a theoretical mixed oxide Hugoniot of anorthite, which is in agreement with new Hugoniot data above about 50 GPa, determined using experimental techniques developed. The mixed oxide model, however, overestimates the shock temperatures, and does not accurately predict measured release paths.

Boslough, M. B.↗

Evaluation of candidate Stirling engine heater tube alloys after 3500 hours exposure to high pressure doped hydrogen or helium

The heater head tubes of current prototype automotive Stirling engines are fabricated from alloy N-155, an alloy which contains 20 percent cobalt. Because the United States imports over 90 percent of the cobalt used in this country and resource supplies could not meet the demand imposed by automotive applications of cobalt in the heater head (tubes plus cylinders and regenerator housings), it is imperative that substitute alloys free of cobalt be identified. The research described herein focused on the heater head tubes. Sixteen alloys (15 potential substitutes plus the 20 percent Co N-155 alloy) were evaluated in the form of thin wall tubing in the NASA Lewis Research Center Stirling simulator materials diesel fuel fired test rigs. Tubes filled with either hydrogen doped with 1 percent CO2 or with helium at a gas pressure of 15 MPa and a temperature of 820 C were cyclic endurance tested for times up to 3500 hr. Results showed that two iron-nickel base superalloys, CG-27 and Pyromet 901 survived the 3500 hr endurance test. The remaining alloys failed by creep-rupture at times less than 3000 hr, however, several other alloys had superior lives to N-155. Results further showed that doping the hydrogen working fluid with 1 vol % CO2 is an effective means of reducing hydrogen permeability through all the alloy tubes investigated.

Misencik, J. A.↗

Contactless Calorimetry for Levitated Samples

Temperature and specific heat of hot sample measured with pyrometer in proposed experimental technique. Technique intended expecially for contactless calorimetry of such materials as undercooled molten alloys, samples of which must be levitated to prevent contamination and premature crystallization. Contactless calorimetry technique enables data to be taken over entire undercooling temperature range with only one sample. Technique proves valuable in study of undercooling because difference in specific heat between undercooled-liquid and crystalline phases at same temperature provides driving force to convert metastable undercooled phase to stable crystalline phase.

Lee, M. C.↗

Reusable rocket engine turbopump condition monitoring

Significant improvements in engine readiness with attendant reductions in maintenance costs and turnaround times can be achieved with an engine condition monitoring system (CMS). The CMS provides real time health status of critical engine components, without disassembly, through component monitoring with advanced sensor technologies. Three technologies were selected to monitor the rotor bearings and turbine blades: the isotope wear detector and fiber optic deflectometer (bearings), and the fiber optic pyrometer (blades). Signal processing algorithms were evaluated and ranked for their utility in providing useful component health data to unskilled maintenance personnel. Design modifications to current configuration Space Shuttle Main Engine (SSME) high pressure turbopumps and the MK48-F turbopump were developed to incorporate the sensors.

Hampson, M. E.↗

Heat Flux Sensor Calibrator

The heat flux to space shuttle main engine (SSME) turbopump turbine blades may be as high as 10 to the 7th power. The heat flux causes thermal transients that are of the order of 1 sec as temperature varies from perhaps 1500 K to 100 K. It is suspected that these transients cause durability problems in the turbine blades. To quantitatively evaluate the effect of these transients, heat flux sensors or gauges were developed to obtain data to verify analytical models. The objective is to design and fabricate a system for steady state and transient calibration and durability testing of heat flux sensors for use in SSME turbine blades. The calibrator consists of: (1) the arc lamp, (2) a high speed positioning table for placing standard and special heat flux sensors in the incident beam of radiant heat flux, (3) provision for cooling the blade and special sensors inserted in the blade, (4) a computer for controlling the positioning table, storing electrical output values from sensors, and calculating heat flux from these values, and (5) a pyrometer for measuring sensor surface temperatures.

Liebert, C. H.↗

Vapor deposited emittance/catalysis coatings for superalloys in heatshield applications

Statically oxidized Inconel 617 and MA 956 superalloys were prepared with vapor deposited aluminosilicate layers and exposed to temperatures which simulated reentry conditions. The aluminosilicate layers were 1-2 microns thick. The trials consisted of exposures to 1500-2300 F heat while surface temperatures were monitored with pyrometers. Analyses were then performed of the catalytic activity, oxidation phenomena, and radiative properties after thermal cycling the specimens for 8 hr. Both alloys were found to be catalytic to the recombination processes of dissociated species in the reentry environment. The coatings reduced the catalytic activity by 40 percent for both alloys but did not change the emittance. An enhanced Cr depletion zone was detected in the Inconel samples, implying that the coating did not prevent diffusion loss of Cr. The coated MA 956, on the other hand, gained weight over the course of the trials.

Clark, R. K.↗

Reusable rocket engine turbopump condition monitoring

Significant improvements in engine readiness with reductions in maintenance costs and turn-around times can be achieved with an engine condition monitoring systems (CMS). The CMS provides health status of critical engine components, without disassembly, through monitoring with advanced sensors. Engine failure reports over 35 years were categorized into 20 different modes of failure. Rotor bearings and turbine blades were determined to be the most critical in limiting turbopump life. Measurement technologies were matched to each of the failure modes identified. Three were selected to monitor the rotor bearings and turbine blades: the isotope wear detector and fiberoptic deflectometer (bearings), and the fiberoptic pyrometer (blades). Signal processing algorithms were evaluated for their ability to provide useful health data to maintenance personnel. Design modifications to the Space Shuttle Main Engine (SSME) high pressure turbopumps were developed to incorporate the sensors. Laboratory test fixtures have been designed for monitoring the rotor bearings and turbine blades in simulated turbopump operating conditions.

Hampson, M. E.↗

Measurement of High Temperature Thermophysical Properties

Technique development and the application of electromagnetic levitation to thermophysical property measurement, including determining heats of fusion, heat capacities, and enthalpy increment functions for extremely refractory materials are discussed. Tungsten properties and the development of an apparatus employing electromagnetic levitation and electron beam heating capable of melting levitating tungsten high temperature heat content measurements by drop calorimetry are emphasized. The development of a prototype microcomputer data acquisition system suitable for controlling the ground based system, with consequent improvement in system handling, which can serve as a model for the system needed for flight experiments is described, which include the development of techniques for imaging pyrometry at temperatures above 3500 K, a semiautomatic calorimeter system capable of handling liquid tungsten, and development of a two color imaging pyrometer system.

Bonnell, D. W.↗

Dynamic Thermophysical Measurements in Space

The objective is to develop techniques for the dynamic measurement of selected thermophysical properties (e.g., heat of fusion, heat capacity, electrical resistivity) of solids and liquids at temperatures above 2000 K in a near zero-gravity environment. The first phase involves establishing the stability (geometrical) limits of specimens when rapidly heated to temperatures beyond their melting point. A test equipment package was designed and constructed for this purpose, consisting of removable specimen cartridge cells, a battery-bank power supply, a high-speed framing camera, a single-wavelength pyrometer, and electronic switching and control equipment. The operation of the equipment package was tested in the laboratory in preparation for near zero-gravity experiments to be performed during a KC-135 flight in September, 1984.

Cezairliyan, A.↗

1700 deg C optical temperature sensor

A new gas temperature sensor was developed that shows promise of sufficient ruggedness to be useful as a gas turbine temperature sensor. The sensor is in the form of a single-crystal aluminum oxide ceramic, ground to a cone shape and given an emissive coating. A lens and an optical fiber conduct the thermally emitted light to a remote and near-infrared photodetector assembly. Being optically coupled and passive, the sensor is highly immune to all types of electrical interference. Candidate sensors were analyzed for optical sensor performance, heat transfer characteristics, stress from gas loading. This led to the selection of the conical shape as the most promising for the gas turbine environment. One uncoated and two coated sensing elements were prepared for testing. Testing was conducted to an indicated 1750 C in a propane-air flame. Comparison with the referee optical pyrometer shows an accuracy of + or - 25 C at 1700 C for this initial development. One hundred cycles from room temperature to 1700 C left the sapphire cone intact, but some loss of the platinum, 6% rhodium coating was observed. Several areas for improving the overall performance and durability are identified.

Mossey, P. W.↗

Ignition of bulk 302 stainless steel in oxygen by laser heating

The effect of oxygen pressure on the ignition temperature of cylindrical 302 SS specimens ignited by a focused CW CO2 laser beam in a cool, static, oxygen environment was investigated. The ignition temperature was determined quantitatively from the specimen temperature history obtained from a fast response, near infrared, two-color pyrometer, which recorded the temperature history of a spot approximately 0.5 mm in diameter and located at the center of the cylindrical 302 SS specimen's top surface. Ignition and combustion occurred in three stages. The first stage began with specimen heating and ended with ignition, the second stage corresponded to combustion, and the third stage represented cooling. The physical changes that occurred in the first stage are described.

Nguyen, K.↗

Advanced bearing materials for cryogenic aerospace engine turbopump requirements

The properties of eleven alloys were investigated to select an improved bearing material for the High Pressure Oxygen Turbo Pump which delivers liquid oxygen to the Space Shuttle Main Engine. The alloys, selected through detailed literature analysis, X 405, MRC-2001, T440V, 14-4/6V, D-5, V-M Pyromet 350, Stellite 3, FerroTic CS-40, Tribaloy 800, WD-65, and CBS-600. The alloys were tested in hardness, corrosion resistance, wear resistance, fatigue resistance, and fracture toughness tests, and their performance was compared with the baseline 440C test alloy. As a result, five alloys were eliminated, leaving the remaining six (X 405, MRC-2001, T440V, 14-4/6V, D-5, and WD-65 to be evaluated in the next phase of NASA tests which will include fracture toughness, rolling contact fatigue, wear resistance, and corrosion resistance. From these, three alloys will be selected, which will be made into ninety bearings for subsequent testing.

Friedman, G.↗

Laser ignition of bulk 1018 carbon steel in pure oxygen

Experiments were undertaken to study the ignition characteristics of bulk 1018 carbon steel in a pure oxygen environment. Cylindrical 1018 carbon steel specimens 5 mm in diameter and 5 mm high were ignited by a focused CW CO2 laser beam in a cool, static, pure oxygen environment at oxygen pressures ranging from 0.103 to 6.895 MPa. A two-color pyrometer was designed and used to measure the ignition temperatures of the specimens. The temperature history of a spot approximately 0.5 mm in diameter located at the center of the specimen top surface was recorded with a maximum time resolution of 25 microsec, and with an accuracy of a few percent. Ignition temperature of bulk 1018 carbon steel was identified from the temperature history curve with the aid of the light intensity curve. Results show that 1018 carbon steel specimens ignite at temperatures between 1388 and 1450 K, which are below the melting range of the alloy (1662-1685 K). The ignition temperature of 1018 carbon steel is mildly dependent on oxygen pressure over the range of oxygen pressure investigated in this study.

Nguyen, K.↗

Noncontacting Inspection Heads For Robots

Compact assembly for hand of robot includes group of sensors to monitor internal conditions of such complex equipment as turbines, pumps, motors, and generators. Inspection head includes sensors; for example, pyrometers, isotope wear analyzers, spectrometers, and interferometers. Conditions as overheating of turbines, wear of ball bearings and seals, erosion of blades and impellers, leakage of joints, and deformations of housings, monitored without disassembly or shutdown. Used in typical robot applications.

Barkhoudarian, Sarkis↗

Optical Sensor Of High Gas Temperatures

Contact pyrometer resists effects of heat, vibration, and moisture. New sensor consists of shielded sapphire rod with sputtered layer of precious metal on end. Metal layer acts as blackbody. Emits radiation having known dependence of spectral distribution with temperature of metal and temperature of hot gas flowing over metal. Fiber-optic cable carries radiation from sapphire rod to remote photodetector.

Hill, Arthur J.↗

Noncontact temperature measurement in glass and other transparent materials

The relationship between the optical properties of glass and temperature measurements in it by radiation pyrometry are described. Equations for the calculation of emissivity are presented and the transmittance, surface reflection and absorption characteristics of glass are defined. Recommendations are given regarding the selection of pyrometer wavelength sensitivity and the use of a blackbody radiator.

Doremus, Robert H.↗

Common but unappreciated sources of error in one, two, and multiple-color pyrometry

The most common sources of error in optical pyrometry are examined. They can be classified as either noise and uncertainty errors, stray radiation errors, or speed-of-response errors. Through judicious choice of detectors and optical wavelengths the effect of noise errors can be minimized, but one should strive to determine as many of the system properties as possible. Careful consideration of the optical-collection system can minimize stray radiation errors. Careful consideration must also be given to the slowest elements in a pyrometer when measuring rapid phenomena.

Spjut, R. Erik↗