Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Quality Assurance Program Plan for SFR Metallic Fuel Data Qualification

This document contains an evaluation of the applicability of the current Quality Assurance Standards from the American Society of Mechanical Engineers Standard NQA-1 (NQA-1) criteria and identifies and describes the quality assurance process(es) by which attributes of historical, analytical, and other data associated with sodium-cooled fast reactor [SFR] metallic fuel will be evaluated. This process is being instituted to facilitate validation of data to the extent that such data may be used to support future licensing efforts associated with advanced reactor designs. The initial data to be evaluated under this program were generated during the US Integral Fast Reactor program between 1984-1994, where the data include, but are not limited to, research and development data and associated documents, test plans and associated protocols, operations and test data, technical reports, and information associated with past United States Nuclear Regulatory Commission reviews of SFR designs. It is recognized that managing the data generated by large research and development projects presents a significant challenge for retaining data integrity and availability. American Society of Mechanical Engineers Standard NQA-1 (NQA-1) 2008/2009a provides appropriate requirements for this plan.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quality Control of Silicon Sensor Modules for Particle Detectors

The High-Luminosity Large Hadron Collider (HL-LHC) will produce a higher rate of particle collisions than the current Large Hadron Collider (LHC), requiring important upgrades to the Compact Muon Solenoid (CMS) to handle an increased amount of data. An important upgrade is the Phase-2 Outer Tracker Upgrade, which consists of 13,000 silicon sensor modules made of two parallel silicon sensors and readout electronics. These modules undergo careful quality control checks both during and after module assembly to ensure precise and reliable detector performance. This project focuses on precision testing for quality control of silicon sensor modules at Fermilab. Hands-on work includes visual inspection, current-voltage testing, module testing, and ultraviolet (UV) light exposure of modules showing abnormal current-voltage behavior. The ultraviolet exposure process improves the abnormal sensor readout data by placing the selected sensor side of the module directly under the UV light inside a controlled box. In addition to laboratory testing and ultraviolet experiments, I developed a Python-based data tool that connects to a module database and allows selected testing conditions and module information to be retrieved and displayed efficiently. These different testing procedures, experimental processes, and computational tools support the broader goal of identifying module issues and improving modules that will be used in the CMS Outer Tracker Phase-2 Upgrade.

Siddiqui, Hooriya [DuPage Coll.] (ORCID:0009000151↗

FC Site 4.0 - NLR Scanning Lidar (Halo XR+ 235) / Standardized and Quality-Controlled Data

This dataset contains lidar data that have been standardized and quality-controlled through NatLabRockies/FIEXTA/LiDARGO (https://github.com/NatLabRockies/FIEXTA/tree/main/lidargo). Standardization rearranges the lidar data into convenient range vs beamID vs scanID coordinates that facilitate data analysis. The scan geometry (i.e., azimuth, elevation) is shifted on a regular grid based on the most likely angles within the scan file. Quality control of radial wind speed is performed through a generalized version of the dynamic lidar filter (Beck and Kuhn, 2017).

17 WIND ENERGY↗

FC Site 4.2 - NLR Scanning Lidar (Halo XR+ 199) / Standardized and Quality-Controlled Data

This dataset contains lidar data that have been standardized and quality-controlled through NatLabRockies/FIEXTA/LiDARGO (https://github.com/NatLabRockies/FIEXTA/tree/main/lidargo). Standardization rearranges the lidar data into convenient range vs beamID vs scanID coordinates that facilitate data analysis. The scan geometry (i.e., azimuth, elevation) is shifted on a regular grid based on the most likely angles within the scan file. Quality control of radial wind speed is performed through a generalized version of the dynamic lidar filter (Beck and Kuhn, 2017).

17 WIND ENERGY↗

FC Site 1.9 - NLR Scanning Lidar (Halo XR+ 200) / Standardized and Quality-Controlled Data

This dataset contains lidar data that have been standardized and quality-controlled through NatLabRockies/FIEXTA/LiDARGO (https://github.com/NatLabRockies/FIEXTA/tree/main/lidargo). Standardization rearranges the lidar data into convenient range vs beamID vs scanID coordinates that facilitate data analysis. The scan geometry (i.e., azimuth, elevation) is shifted on a regular grid based on the most likely angles within the scan file. Quality control of radial wind speed is performed through a generalized version of the dynamic lidar filter (Beck and Kuhn, 2017).

17 WIND ENERGY↗

Model Quality and Measurement Density Impact on Volt/Volt Ampere Reactive Optimization Performance

The operation of the utility grid is being reshaped by the continuous addition of distributed energy resources and advanced metering infrastructure, which challenge existing grid control strategies. Some utilities deploy advanced distribution management systems (ADMS) to assist with the consolidation of various applications and to augment situational awareness in response to the new power delivery dynamics. An ADMS is an integrated software platform that provides utilities with a way to enhance their reliability, control, and optimization with advanced applications, such as volt/VAR optimization (VVO). A VVO application could serve as a vehicle to deliver cost savings by providing the utility with a method to reduce rates by controlling the voltage and decreasing the energy usage in their service territory. Some utilities are reluctant to integrate an ADMS, because it is a significant investment that requires approval from the public regulatory commission and/or their customers. This paper evaluates the impact on VVO performance when using a lower-quality network model supplemented with additional measurements, which could provide an implementation for cost savings. The results show that a better model quality would provide the highest energy savings; however, some level of telemetry is necessary in all scenarios to prevent voltage exceedances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-quality Extragalactic Legacy-field Monitoring (HELM) with DECam

High-quality Extragalactic Legacy-field Monitoring (HELM) is a long-term observing program that photometrically monitors several well-studied extragalactic legacy fields with the Dark Energy Camera (DECam) imager on the CTIO 4m Blanco telescope. Since Feb 2019, HELM has been monitoring regions within COSMOS, XMM-LSS, CDF-S, S-CVZ, ELAIS-S1, and SDSS Stripe 82 with few-day cadences in the $(u)gri(z)$ bands, over a collective sky area of $\sim 38$ deg${\rm ^2}$. The main science goal of HELM is to provide high-quality optical light curves for a large sample of active galactic nuclei (AGNs), and to build decades-long time baselines when combining past and future optical light curves in these legacy fields. These optical images and light curves will facilitate the measurements of AGN reverberation mapping lags, as well as studies of AGN variability and its dependences on accretion properties. In addition, the time-resolved and coadded DECam photometry will enable a broad range of science applications from galaxy evolution to time-domain science. We describe the design and implementation of the program and present the first data release that includes source catalogs and the first $\sim 3.5$ years of light curves during 2019A--2022A.

79 ASTRONOMY AND ASTROPHYSICS↗

The HTAP_v3.2 emission mosaic: merging regional and global monthly emissions (2000–2020) to support air quality modelling and policies

This study, performed under the umbrella of the Task Force on Hemispheric Transport of Air Pollution (TF-HTAP), responds to the need of the global and regional atmospheric modelling community of having a mosaic emission inventory of air pollutants that conforms to specific requirements: global coverage, long time series, spatially distributed emissions with high time resolution, and a high sectoral resolution. The mosaic approach of integrating official regional emission inventories based on locally reported data, with a global inventory based on a globally consistent methodology, allows modellers to perform simulations of a high scientific quality while also ensuring that the results remain relevant to policymakers. HTAP_v3.2, an ad-hoc global mosaic of anthropogenic inventories, is an update to the HTAP_v3 global mosaic inventory and has been developed by integrating official inventories over specific areas (North America, Europe, Asia including China, Japan and Korea) with the independent Emissions Database for Global Atmospheric Research (EDGAR) inventory for the remaining world regions. The results are spatially and temporally distributed emissions of SO 2 , NO x , CO, NMVOC, NH 3 , PM 10 , PM 2.5 , Black Carbon (BC), and Organic Carbon (OC), with a spatial resolution of 0.1 × 0.1° and time intervals of months and years covering the period 2000–2020 (https://doi.org/10.5281/zenodo.17086684, Crippa, 2025, https://edgar.jrc.ec.europa.eu/dataset_htap_v32, last access: 27 October 2025). The emissions are further disaggregated to 16 anthropogenic emitting sectors. This paper describes the methodology applied to develop such an emission mosaic, reports on source allocation, differences among existing inventories, and best practices for the mosaic compilation. One of the key strengths of the HTAP_v3.2 emission mosaic is its temporal coverage, enabling the analysis of emission trends over the past two decades. The development of a global emission mosaic over such long time series represents a unique product for global air quality modelling and for better-informed policy making, reflecting the community effort expended by the TF-HTAP to disentangle the complexity of transboundary transport of air pollution.

Guizzardi, Diego [European Commission, Ispra (Ital↗

Energy Efficiency and Indoor Environmental Quality Assessment Guide

This report provides thorough guidance when preparing for an energy and indoor environmental quality (IEQ) assessment. It includes step-by-step instructions, detailed insights, and practical examples for the various phases of an energy and IEQ assessment. IEQ encompasses indoor building conditions—such as air quality, thermal comfort, acoustics, and lighting— and is a growing field of interest among a diverse range of stakeholders (e.g., building owners and managers) due to the effects it has on occupant health and productivity. IEQ improvement strategies often provide overlapping opportunities for increasing building energy efficiency, creating a win-win situation for building operations.

Esaki-Kua, Lauren↗

Quality Control of Silicon Sensor Modules for Particle Detectors

The High-Luminosity Large Hadron Collider (HL-LHC) will produce a higher rate of particle collisions than the current Large Hadron Collider (LHC), requiring significant upgrades to the Compact Muon Solenoid (CMS) to handle the increased amount of data. An important upgrade is the Phase-2 Outer Tracker Upgrade, which consists of 13,000 silicon sensor modules made of two parallel silicon sensors and readout electronics. These modules undergo careful quality control checks both during and after module assembly to ensure precise and reliable detector performance. This project focuses on precision testing for quality control of silicon sensor modules at Fermilab. Hands-on work includes visual inspection, current-voltage testing, module testing, and ultraviolet (UV) light exposure of modules showing abnormal current-voltage behavior. The ultraviolet exposure process improves the abnormal sensor readout data by placing the selected sensor side of the module directly under the UV light inside a controlled box. In addition to laboratory testing and ultraviolet experiments, I developed a Python-based data tool that connects to a module database and allows selected testing conditions and module information to be retrieved and displayed efficiently. These different testing procedures, experimental processes, and computational tools support the broader goal of identifying module issues and improving modules that will be used in the CMS Outer Tracker Phase-2 Upgrade.

Siddiqui, Hooriya [DuPage Coll.; Fermilab] (ORCID:↗

Quality and Loss Factor Characterization of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons under a strong magnetic field through resonant cavity techniques. The conversion produces an extremely small signal, requiring a cryogenic environment to reduce thermal noise, and low-loss superconducting transmission lines for minimal attenuation in the readout chain. Yttrium barium copper oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss cryogenic cables such as niobium (Nb) and niobium titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We characterized the quality and loss of five stripline resonators from the Brookhaven Technology Group: three YBCO, a copper reference, and a silver reference. Experimental methodology included collecting scattering parameter data on a vector network analyzer for the samples at 77 K along with room temperature baseline measurements, and employing both Lorentzian-fit and circle-fitting techniques to confirm the coupling regime and corroborate results. We achieved quality factors on the order of $10^3$ with corresponding loss factors on the order of $10^{-1}$ dB/m. Trends were comparable with literature data on Nb and NbTi at 4 K, which did have lower loss under these conditions, but suggested similar or perhaps better loss for YBCO when accounting for the temperature difference. We also developed a cryogenic probe for future measurements in a 14 T applied field at 30 mK. This will serve to directly evaluate YBCO's durability in magnetic fields, and we expect significantly improved performance at millikelvin temperatures.

Marinos, Z. [UCLA]↗

Local Air Quality Impacts of a Peak-Shaving Diesel Generator Unit in Waynesville, North Carolina

The Waynesville Electric Department in Waynesville, North Carolina, operates a 2,000-kW diesel generator with a 4% capacity factor, emitting less than 1 ton annually of PM2.5, VOCs, carbon monoxide (CO), and sulfur dioxide (SO2), and approximately 1.8 tons of NO. The National Laboratory of the Rockies (NLR) conducted high-resolution, near-source air-quality modeling to evaluate the generator's impacts. Results indicate minimal effects on ambient pollutant concentrations: annual PM2.5 increases are below 0.0004 microgrm/m3 for local census tracts, while CO and SO2 levels increase by less than 0.00004 ppm and 0.0002 ppb, respectively. Estimated annual premature mortality attributable to PM2.5 exposure is less than 0.001 cases across Haywood County, with an associated economic impact of approximately $12,000. This report complements a separate technoeconomic analysis to inform Waynesville's investment strategies for demand reduction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The health and indoor environmental quality impacts of residential building envelope retrofits: A literature review

Retrofitting existing buildings to improve energy efficiency is an important strategy to meet increasingly stringent energy efficiency targets. While the primary objective of energy efficiency retrofits is to reduce energy consumption and greenhouse gas emissions, retrofits can also result in non-energy impacts (NEIs), which contribute to decision-making processes and overall value of the retrofit. NEIs have been studied extensively in retrofitted residential buildings; however, these studies have historically grouped passive (i.e., building envelope) and active (i.e., heating, ventilation, and air conditioning (HVAC) and energy system) upgrades, making it difficult to identify the underlying mechanism(s) of action for each NEI and developing effective retrofit strategies, based on occupant need. The purpose of this study was to better account for NEIs, based on a literature review, summarizing the current state of knowledge on NEIs associated with residential building envelope retrofits. We limited our search to health- and indoor environmental quality-related NEIs. The review identified strong evidence that building envelope retrofits improve acoustic comfort, wintertime thermal comfort, and respiratory and cardiovascular health outcomes. IAQ outcomes were mixed, with studies reporting both increases and decreases to indoor contaminant concentrations following retrofits. The strength of the effect was generally governed by pre-retrofit contaminant concentrations and whether indoor concentrations were dominated by indoor or outdoor sources. Most studies evaluating summertime thermal comfort identified increased incidence of summertime overheating; however, none of these studies linked the change in thermal conditions to health outcomes. Recommendations for future work include expanding studies to include more market rate housing and the health impacts of summertime overheating in retrofitted buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Climate, air quality, and equity benefits from hydrogen substitution for fossil fuels used in process heat

Fossil fuel combustion for process heat in heavy industry accounts for ~15% of all United States CO 2 emissions and emits PM 2.5 and its precursors, emissions that have a disproportionate impact on minority populations. Decarbonizing process heat in the U.S. via hydrogen substitution presents an opportunity to reduce emissions of CO 2 and PM 2.5 and mitigate resulting exposure disparity. Here, we show that hydrogen substitution in steelmaking provides a large reduction in CO 2 emissions and air quality-related premature mortality, while hydrogen substitution in petroleum refining substantially benefits disadvantaged communities. When reductions in CO 2 emissions and premature mortality are monetized using standard regulatory values, we find that the sum of air pollution and climate benefits outweighs the difference in private cost associated with hydrogen substitution in steelmaking, regardless of the method of hydrogen production. The approach developed here can support evaluations of equity-focused decarbonization strategies in other industries and for specific sites.

08 HYDROGEN↗

Enhancing Drinking Water Quality Modeling: Leveraging Physics Informed Neural Networks for Learning with Imperfect Reaction Models and Partial Data

Chemical kinetics models, typically formulated as systems of ordinary or partial differential equations, are valuable tools for simulating drinking water quality. However, these models often face inaccuracies due to discrepancies between the laboratory and the real-world conditions, as well as limitations in experimental analytical methods, hindering the accurate representation of the true underlying chemical mechanisms. In this study, we propose a Physics Informed Neural Network (PINN), using the eXtreme Theory of Functional Connections, to improve the prediction of chemical concentrations over time. The PINN method accounts for imperfect chemical models and incorporates partial data to improve predictions. Focusing on reactions describing water disinfection residual and disinfectant byproduct formation, which are crucial for public health and regulatory compliance, we demonstrate that the PINN model is able to accurately predict the concentrations of chemical species across various pH values. Notably, the model extends its accuracy to predict concentrations of chemical species not originally included in its training data. The developed method can be extended to a variety of chemical systems, offering a wide array of potential applications.

13 HYDRO ENERGY↗

Meta‐Analysis and Regression Modeling of the Impacts of Four Indoor Environmental Quality Metrics on Office Performance

Awareness of how buildings interact with the occupant experience—especially human performance—is becoming more prevalent, as seen by increasing interest and investment in healthy built environments. However, there is a need to synthesize the wide array of existing indoor environmental assessment and performance research in a way that can translate directly to building design and operation. Existing research in this area typically focuses on a single isolated metric and has not focused on making the results utilizable by building practitioners. The aim of this research is to investigate existing office performance literature through meta‐analyses and produce regression models for four indoor environmental quality (IEQ) metrics to support critical decision‐making for building operation and renovation. To reach this aim, a literature review was conducted to identify studies that measure the impact of changing ventilation rate, temperature, horizontal illuminance, and noise level in offices on occupant task performance. This repository of field and laboratory studies was analyzed to visualize the trends between the selected IEQ metrics and task performance. The temperature, ventilation rate, and horizontal illuminance regression models showed clear improvement potential when modifying indoor conditions toward the defined high‐performance range, while the regression model for noise level was inconclusive. The discussion notes the importance of designing holistically for all components of these IEQ categories to utilize the results, for example, good filtration on outdoor air for quantifying ventilation impact and uniform overhead lighting with low contrast for quantifying horizontal illuminance impact. The novelty of this work is in considering multiple facets of the indoor environment under a single, unified analysis schema and producing IEQ‐based performance gains that can directly inform cost‐benefit analyses of building design and renovation.

60 APPLIED LIFE SCIENCES↗

Quality Guidelines for Energy System Studies: Process Modeling Design Parameters

The National Energy Technology Laboratory (NETL) conducts systems analysis studies that require a large number of inputs, from ambient conditions to parameters for Aspen Plus ® (Aspen) process blocks. The sheer number of assumptions required makes it impractical to document all of them in each issued report. The purpose of the Quality Guidelines for Energy System Studies (QGESS) is to document the assumptions most commonly used in system analysis studies and the basis for those assumptions. In order to develop the systems analysis models presented in various NETL reports, significant vendor data have been obtained, and these data enhance the model outputs. Much of the vendor data obtained are considered proprietary and not suitable for public release or attribution to a specific vendor. As such, several sub-systems common in NETL reports and their process parameter data are not reported in this document to protect proprietary vendor information. The values and ranges of values presented in this report represent assumptions that have been made in previous studies.

97 MATHEMATICS AND COMPUTING↗

Quality Guidelines for Energy System Studies: Capital Cost Scaling Methodology: Revision 4b Report

The National Energy Technology Laboratory (NETL) regularly updates legacy analysis with new studies and cases as the Department of Energy objectives change, technology performance improves, costs are reduced, regulations change, market drivers are established, fuel prices fluctuate, and any number of other relevant factors vary in the market. As legacy studies are updated by NETL, the underlying performance and cost of the cases presented changes, and as such, the methods for interpreting and scaling the cost estimates change. Therefore, it is important that NETL maintain public guidance documents associated with different sets of cost estimates that delineate how a specific set, based on report vintage and/or year published, should be scaled. This Quality Guidelines for Energy System Studies report, providing guidance on capital cost scaling, should generally be applied to NETL case costs included in the report “Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity Revision 4b,” (NETL, 2025) or any cases derived from the cases presented in the referenced report.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗