SEARCH · Search NASA
Results for “radiation detection”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Proton Quenching in Rare-Earth Inorganic Scintillators: GAGG:Ce and YSO:Ce
Scintillator detectors are an integral component of radiation detection systems for a variety of applications such as medical imaging, accelerator diagnostics, and space science. Typically, a scintillator detector’s response is characterized using gamma sources to understand the detection response to different types of radiation, including charged particle detection. However, there exists a nonlinearity of the amount of light produced from an incident gamma ray of specific energy and the light produced from an incident charged particle of the same energy. This important effect, known as quenching, must be accounted for to interpret energies from charged particles incident on detectors. In this article, we present results of quenching parameterization for two types of cerium-doped inorganic scintillators, Y2SiO5:Ce (YSO:Ce) and Gd3Al2Ga3O12:Ce (GAGG:Ce). We measured the light output from incident proton energies from 1 to 25 MeV using a 3-MV tandem accelerator and two reactions: Au(p,p)Au and 3He(d,p)⁴He. Using gamma-ray sources to calibrate the detectors, we compared the measured electron-equivalent energy versus the incident energy expected. Using an adaptation of the Birks semi-empirical formula, we extracted the Birks parameter (kB) to understand quenching. For one of the GAGG:Ce samples, the kB parameter of 0.0072 [g cm-2 MeV-1] is comparable to a similar study where the value of kB was 0.0065 [g cm-2 MeV-1]. For YSO:Ce, no other kB values were found in the literature. Three different types of GAGG:Ce were used to collect measurements of kB as a function of dopant concentration.
Polimaster PM1401K-3 Test Report
Extensive testing, including measurements on large quantities of special nuclear material, were taken to assess the functionality of the Polimaster PM1401K-3 to other detectors used in the field. The Polimaster can detect alpha, beta, gamma, and neutron radiation. However, efficiency and accuracy has been sacrificed to accomplish this. Compared to the IdentiFINDER 2, SRM, and FH-40 alpha probe, the Polimaster underperforms in almost all categories regarding radiation detection. The Helium-3 neutron detector in the Polimaster, due to a larger volume, outperformed the IdentiFINDER 2 for neutron measurements. The alpha search mode showed higher efficiency than the FH-40 alpha probe, but uses a more complicated process. The user interface is relatively easy to navigate, clear, and comparable to other detectors. However, the detector has added complications when trying to detect alpha or beta radiation or save a spectrum.
Polysiloxane Scintillators for Efficient Neutron and Gamma-Ray Pulse Shape Discrimination
Plastic scintillators based on thermoplastics, such as polystyrene and poly(vinyl toluene) (PVT), are capable of neutron and γ radiation detection via pulse shape discrimination (PSD) when overdoped with select fluorescent molecules. This class of plastic scintillator has been extensively studied but is limited to applications suitable for thermoplastics. For applications requiring flexibility, scintillators composed of elastomers, such as polysiloxanes, offer an alternative to PVT scintillators. Polysiloxane scintillators are inherently flexible and have a short processing time on the order of 3 h in air and equivalent or better detection capability at reduced doping concentration (<5 wt %). This work presents polysiloxane-based scintillators, containing only 1–5 wt % of 2,5 diphenyl-oxazole (PPO) or 9,9-dimethyl-2-phenyl-9H-fluorene (PhF) as primary dopants and 9,9-dimethyl-2,7-distyryl-9H-fluorene (SFS) as a wavelength shifter. A 5 wt % PPO polysiloxane sample had improved neutron and gamma ray PSD and comparable light yield than EJ-299-33 tested under the same conditions, i.e., figure of merit (FoM) of 1.33 ± 0.03 at 450 keV ee and light yield of 94% relative to EJ-299-33. The 5 wt % PhF-polysiloxane sample had a higher light yield, 144% of EJ-299-33 but lower FoM under the same conditions (FoM of 1.09 ± 0.03). Furthermore, this work highlights the potential of polysiloxanes as a matrix for PSD capable plastic scintillators.
Long-length Scintillating Fibers for Nuclear Geological Repositories
This research focuses on the usage of plastic scintillating fibers as ruggedized detectors in long-length sections coupled to long-length standard optical fiber segments for the purpose of radiation detection and monitoring. This technology addresses a need for monitoring radiation in difficult-to-access or inaccessible areas, such as monitoring: radioactive waste within geological repositories, nuclear material storage facilities, spent fuel dry storage areas, inaccessible areas within nuclear facilities including reactors and reprocessing facilities, decommissioning of nuclear facilities, and other similar areas. The fiber can be placed along the tunnels of a geological repository to monitor the radiation field along its length. This can detect an increase of radiation due to movement, leakage, or unexpected opening of the containers, as well as decrease in the radiation due to removal of material. These capabilities have been demonstrated at INL’s Radioactive Scrap Waste Facility by successfully detecting the removal of an interim storage containers from the storage area. The poster focuses on explaining the technology and its capability in monitoring deep geological repositories (DGRs), especially in the domain of safety and international safeguards. As more countries consider the development of DGRs, technologies such as the one being presented can help establish continuity of knowledge of the material, maintain public confidence, and ensure safe operation of the facility. Furthermore, the poster looks at the future steps of the technology and its potential role in the international safeguards regime.
Experimental Testing of Personal Dosimetry Interference from a Portable X-ray Generator
The determination of the disposition route for a legacy drum in a nuclear facility at the Y-12 National Security Complex is supported by non-destructive testing of the drum and its contents. An advanced radiation measurements organization at the Y-12 National Security Complex proposed a series of active measurements using a portable x-ray generator, imaging the drum and its contents with 360-degree visualization. In rooms near the current storage location for the drum, Criticality Accident Alarm System (CAAS) annunciation is degraded, and Personal Radiation Dosimetry Instruments (PRDI’s) are routinely worn by personnel. The Y-12 Development Organization has procured advanced radiation detection devices and a variety of radiation sources for use in active measurements. These devices are being used to support Y-12 operations and safety engineering disciplines to safely address complex challenges throughout the complex. This paper presents the results of experimental testing of the PRDI’s used at Y-12 with the x-ray generator [1], and notes the unique utilization of a decommissioned facility for this work.
Methods and apparatus for improved thermal monitoring by correlating infrared emissivity to surface topography
Embodiments of the present disclosure provide an improved method and apparatus for thermal monitoring for a metal additive manufacturing system. An emissivity value of a top surface of an object to be manufactured is determined based, at least in part, on an arithmetic product of a predetermined roughness value and a predetermined slope-related value. The predetermined roughness value and slope-related values are predetermined based, at least in part, on measurements of a previously manufactured object. The system sinters a metal to form the top surface of the object to be manufactured. An infrared sensor detects radiation from at least a portion of the top surface of the object to be manufactured. A temperature is generated based, at least in part, on the detected infrared radiation and the emissivity value and the generated temperature is applied to a temperature utilization component of the system.
Radiation Detectors for DHS Applications
Presentation to be presented during the 2021 ANS Virtual Meeting, Radiation Detection for Homeland Security Technical Session, on June 14, 2021 (https://www.ans.org/meetings/am2021/session/view-582/).
Monte Carlo simulation of the passage of $\gamma$-rays and $\alpha$-particles in CsI
In this work, theoretical and computational methods for simulating the creation of ionization tracks by fast ions in solids were applied to the passage of a-particles in CsI, an inorganic scintillator commonly used for radiation detection. The methods were implemented in a Monte Carlo program to simulate the interaction of $\alpha$-particles, with incident energies of up to 1 MeV, with CsI. The simulations followed the fate of individual electron-hole pairs and thus allowed for a detailed description of the microscopic structure of ionization tracks created by incident radiation. Simulations were also performed with $\gamma$-rays of the same energy to compare and contrast the ionization tracks obtained with both types of particle. Intrinsic properties such as the mean energy per electron-hole pair, Fano factor, maximum theoretical light yield, and spatial distributions of electron-hole pairs were computed for both $\alpha$-particles and $\gamma$-rays. $\alpha$-particles created cylindrical tracks that were initially aligned with the incident direction and with initial radii of a few nanometers, whereas $\gamma$-rays showed significant scattering, resulting in probability distributions with lower intensities and much greater radial extents.
Fully depleted charge‐coupled device design and technology development
Abstract We describe the advancement of fully depleted charge‐coupled device (CCD) technology for scientific applications. Recent efforts on 650–725 m‐thick CCDs for direct dark‐matter and radiation detection with single‐electron sensitivity are described, as well as the technology transfer of the fully depleted CCD technology to 200 mm‐wafer fabrication facilities.
Mixed Material Scintillator Systems Particle ID Modelling Report
AMixed-Material Scintillator System (MMSS) is a radiation detector using a scintillator made of a heterogeneous, structured mixture of two or more materials. MMSSs are designed so that the structured mixing of materials encodes properties of the radiation detected in the scintillator. This allows for new radiation detectors with advantages over detectors using traditional homogeneous scintillators. This report contains results from this project’s second task, to model and quantify the promise of the MMSSs invented earlier in the project. Those inventions have been divided into two categories, and this report focuses on the first category: MMSS inventions the use zones of differently-colored scintillators to detect and characterize neutron sources. We call this category particle-ID, or PID, detectors. Inventions using gradients designed to encode the position of radiation interactions using gradients will be discussed in a future report.
Direct metal contacts printing on 4H-SiC for alpha detectors and inhomogeneous Schottky barriers
Electrical characterization of several 4H-SiC Schottky diodes with Aerosol-Jet printed gold (Au), silver (Ag), and platinum (Pt) contacts was performed using forward and reverse current–voltage (IV) measurements. From these measurements, device parameters such as Schottky barrier height and ideality factor were determined; however, many of the devices exhibited nonideal behavior and inferior performance characterized by ideality factors significantly greater than one, disproportionate low voltage leakage current and low barrier heights. Forward current–voltage (FIV) characteristics were fitted to an inhomogeneous barrier height theory to explain the abnormal behavior exhibited by the printed devices. Here, transmission electron microscopy (TEM) of the device cross-sections was performed to investigate the printed metal and semiconductor epitaxial layer interface, which revealed the imperfections in the metal–semiconductor contact. Despite these irregularities, alpha radiation detection capability of these devices was still achieved with an energy resolution of 1.89% at 5.486 MeV, and the best achievable resolution at 0.51% with no energy degradation of 5.486 MeV.
Improved light yield and growth of large-volume ultrafast single crystal scintillators Cs 2 ZnCl 4 and Cs 3 ZnCl 5
Due to their reported fast decay times, Cs 2 ZnCl 4 and Cs 3 ZnCl 5 are promising candidates for detection of gamma rays and X-rays in high count rate and fast timing applications. In this work, we show that single crystals with better optical quality than previously demonstrated – and larger in size – can be grown via the vertical Bridgman method. Highly transparent Ø7 mm crystals of undoped Cs 2 ZnCl 4 and Cs 3 ZnCl 5 are grown and measured to have light yields surpassing those previously reported, achieving 1980 ± 100 ph/MeV and 1460 ± 70 ph/MeV at 662 keV – a 55% and 232% improvement, respectively. We observe single-component scintillation decay times for both Cs 2 ZnCl 4 (1.66 ns) and Cs 3 ZnCl 5 (0.82 ns) and radioluminescence emission with maximum intensity at ~290 nm. Scalability of these materials is also evaluated based on growth of Ø22 mm crystals. Minimal cracking is observed, and the fast decay times are maintained at this size. Coincidence time resolution of 3 × 3 × 5 mm 3 and 7 × 7 × 10 mm 3 pixels cut from Ø22 mm Cs 2 ZnCl 4 are measured to be 148 ± 1 ps FWHM and 175 ± 1 ps FWHM, respectively. Here, the improved performance and ability to be fabricated in large sizes now place Cs 2 ZnCl 4 and Cs 3 ZnCl 5 on the map as potential contenders for radiation detection applications where BaF 2 – the most commonly used ultrafast inorganic scintillator – is typically considered.
TORONE: Total Characterisation by Remote Observation of Nuclear Environments - 20591
This paper describes the autonomous robotic systems developed in the TORONE project (Total Characterisation by Remote Observation of Nuclear Environments) for combined characterisation by remote techniques in nuclear environments. There are four main components to the system. Firstly, robot operation which uses a Robot Operating System (ROS) allowing ease of communication between hardware and software alongside robot vision systems such as Lidar and/or photogrammetry. Secondly, radiation detection instrumentation for gamma and neutron sources which is also collimated for spatial resolution. Thirdly, photonic characterisation instrumentation for remote material identification by means of Raman spectroscopy and Laser induced breakdown spectroscopy (LIBS). Finally, a data management system is described which contains the TORONE characterisation data with the ability to overlay material characterisation information onto 3D maps of the nuclear environment. Preliminary results are described alongside discussion of some of the synergies of the combined approach. There are many applications of such an autonomous system in nuclear decommissioning, waste management and asset management. (authors)
Crystal growth, scintillation properties & fast neutron-gamma discrimination of cubic halide perovskite CsCaCl 3 :(Eu 2+ , Tl + )
The vast variety of nuclear security applications require radiation detection materials tailored to their operational needs. A scintillator’s properties are strongly influenced by the choice of luminescent dopant, which facilitates customization to different applications. In this work, transparent Ø12 mm single crystals of undoped CsCaCl 3 , CsCaCl 3 :1% Eu, CsCaCl 3 :1% Tl, and CsCaCl 3 :1% Eu, 1% Tl were grown via the Vertical Bridgman method. Their scintillation properties and fast neutron-gamma discrimination capabilities were investigated. Undoped CsCaCl 3 had a light yield of 2,500 ph/MeV, which is the highest reported to date for this CVL material. The incorporation of Eu 2+ or Tl + into CsCaCl 3 as luminescence centers resulted in significantly higher light yields of ∼16,000 ph/MeV and energy resolutions of ∼8% at 662 keV. Compared to the single dopant counterparts, CsCaCl 3 :Eu, Tl had significantly suppressed afterglow; however, this came at the cost of reduced light yield. Among the materials tested, only CsCaCl 3 :Tl showed effective fast neutron and gamma discrimination capabilities, achieving a Figure of Merit of 3.2 between gamma-rays and fast neutron captures that produce protons and 1.6 between gamma-rays and fast neutron captures that produce alpha particles.
Unsupervised Learning for Improved Gamma-Ray Spectrometry in Pixelated Cadmium Zinc Telluride (CZT) Detectors
Machine learning has been found to be ubiquitously useful across many industries, presenting an opportunity to improve radiation detection performance using data-driven algorithms. Improved detector resolution can aid in the detection, identification, and quantification of radionuclides. Here, in this work, a novel, data-driven, unsupervised learning approach is developed to improve detector spectral characteristics by learning, and subsequently rejecting, poorly performing regions of the pixelated detector. Feature engineering is used to fit individual characteristic photo peaks to a Doniach lineshape with a linear background model. Then, principal component analysis is used to learn a lower-dimension latent space representation of each photo peak where the pixels are clustered, and subsequently ranked, based on the cluster mean distance to an optimal point. Pixels within the worst cluster(s) are rejected to improve the full-width at half-maximum (FWHM) by 10% to 15% (relative to the bulk detector) at 50% net efficiency when applied to training data obtained from measurements of a 100 μCi 154 Eu source using a H3D M400i pixelated cadmium zinc telluride detector. These results compare well with, but do not outperform, a greedy algorithm that accumulates pixels in order of FWHM from lowest to highest used as a benchmark. In the future, this approach can be extended to include the detector energy and angular response. Finally, the model is applied to newly seen natural and enriched uranium spectra relevant for nuclear safeguards applications.
Impurity-enhanced core valence luminescence via Zn-doping in cesium magnesium chlorides
Scintillators with faster timing capabilities are currently in high demand for use in radiation detection systems in the fields of nuclear and medical physics. The limited number of suitable materials that meet the performance criteria of next generation detection systems presents an opportunity for discovery of new fast scintillator materials. In this work, the effects of doping several ultrafast core-valence luminescent (CVL) scintillators with divalent Zn is explored. Three compounds are investigated – CsMgCl 3 , Cs 2 MgCl 4 , and Cs 3 MgCl 5 – and single crystals of each doped with 5 mol% Zn are grown via the Bridgman method. Additionally, mixing across the full range of concentrations (from 0 % to 100 % Zn) is explored in the Cs 2 Mg 1-x Zn x Cl 4 and Cs 3 Mg 1-x Zn x Cl 5 systems. For low concentrations of Zn, light yields of all three compounds are enhanced (by up to ~60 %) compared to the pure crystals, achieving what we believe to be the brightest known CVL, CsMgCl 3 :Zn 5 % (3400 ± 170 ph/MeV light yield). More importantly, Zn doping does not affect the ultrafast timing properties, with each composition maintaining a single-component decay time around 1–3 ns. A sub-100 ps coincidence time resolution (CTR) is also achieved with CsMgCl 3 :Zn 5 %. The results of this work reveal a new avenue towards obtaining brighter CVL materials, which could open up possibilities for more advanced ultrafast scintillators to be discovered moving forward.
Influence of fluorescent dopants on the vat photopolymerization of acrylate-based plastic scintillators for application in neutron/gamma pulse shape discrimination
Plastic scintillators, a class of solid-state materials used for radiation detection, were additively manufactured with vat photopolymerization. The photopolymer resins consisted of a primary dopant and a secondary dopant dissolved in a bisphenol A ethoxylate diacrylate-based matrix. The absorptive dopants significantly influence important print parameters, for example, secondary dopants decrease the light penetration depth by a factor > 12×. The primary dopant 2,5-diphenyloxazole had minimal impact on the printing process even when loaded at 25 % by mass of the resin. Working curve measurements, which relate energy dose to cure depth, were performed as a function of feature size to further assess the influence of dopants. Photopatterns smaller than 150 µm width had apparent increases in critical energy dose compared to larger photopatterns, while all resins maintained printed features in line gratings with 50 µm of separation. Printed scintillator monoliths were compared to scintillators cast by traditional molding, demonstrating that the layer-by-layer printing process does not decrease scintillation response. In conclusion, a maximum light output of 31 % of a benchmark plastic scintillator (EJ-200) and successful pulse shape discrimination were achieved with 20 % by mass 2,5-diphenyloxazole as the primary dopant and 0.1 % by mass 9,9-dimethyl-2,7-distyrylfluorene as the secondary dopant in printed scintillator samples.