Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiation detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

System and method for passive assay of holdup deposits in nuclear piping

Disclosed herein are a method, apparatus, and software for passive, non-destructive assay of holdup deposits in nuclear piping by in-pipe apparatus. A detector deployed within a pipe is collimated to observe radiation impinging radially inward from decay of deposits that lie on the pipe wall. A radiation detector is centered in the pipe and collimated by a pair of coaxial shielding discs disposed equidistant from the detector. This arrangement causes radiation from a truncated cylinder of pipe deposit within a field of regard to impinge on the detector, while precluding radiation emanating from pipe walls beyond the field of regard from reaching the detector. Hence, observations are unique to a known cylindrical length of pipe. The detector assembly is translated through pipes by an autonomous mobile robotic apparatus. Computer software controls the robotic apparatus, logs data, and post-processes to assay deposits.

Whittaker, William Lawrence↗

A sensitive and robust thin-film x-ray detector using 2D layered perovskite diodes

Solid-state radiation detectors, using crystalline semiconductors to convert radiation photons to electrical charges, outperform other technologies with high detectivity and sensitivity. Here, we demonstrate a thin-film x-ray detector comprised with highly crystalline two-dimensional Ruddlesden-Popper phase layered perovskites fabricated in a fully depleted p-i-n architecture. It shows high diode resistivity of 10 12 ohm·cm in reverse-bias regime leading to a high x-ray detecting sensitivity up to 0.276 C Gy air –1 cm –3 . Such high signal is collected by the built-in potential underpinning operation of primary photocurrent device with robust operation. The detectors generate substantial x-ray photon–induced open-circuit voltages that offer an alternative detecting mechanism. Furthermore, our findings suggest a new generation of x-ray detectors based on low-cost layered perovskite thin films for future x-ray imaging technologies.

47 OTHER INSTRUMENTATION↗

Effects of natural zeolites on field-scale geologic noble gas transport

Improving predictive models for noble gas transport through natural materials at the field-scale is an essential component of improving US nuclear monitoring capabilities. Several field-scale experiments with a gas transport component have been conducted at the Nevada National Security Site (Non-Proliferation Experiment, Underground Nuclear Explosion Signatures Experiment). However, the models associated with these experiments have not treated zeolite minerals as gas adsorbing phases. This is significant as zeolites are a common alteration mineral with a high abundance at these field sites and are shown here to significantly fractionate noble gases during field-scale transport. This fractionation and associated retardation can complicate gas transport predictions by reducing the signal-to-noise ratio to the detector (e.g. mass spectrometers or radiation detectors) enough to mask the signal or make the data difficult to interpret. Omitting adsorption-related retardation data of noble gases in predictive gas transport models therefore results in systematic errors in model predictions where zeolites are present.Herein is presented noble gas adsorption data collected on zeolitized and non-zeolitized tuff. Experimental results were obtained using a unique piezometric adsorption system designed and built for this study. Data collected were then related to pure-phase mineral analyses conducted on clinoptilolite, mordenite, and quartz. These results quantify the adsorption capacity of materials present in field-scale systems, enabling the modeling of low-permeability rocks as significant sorption reservoirs vital to bulk transport predictions.

58 GEOSCIENCES↗

Tl+-based and mixed halide A3B2X9-type scintillators

Inorganic halides (e.g., inorganic halide scintillators) of the general formula A3B2X9, including inorganic halides comprising thallium monovalent cations and/or combinations of different halides, are described. Radiation detectors including the inorganic halide scintillators and methods of using the detectors to detect high energy radiation are also described. In some cases, the scintillators can include a gadolinium cation, a boron cation, a lithium cation, a chloride ion, or combinations thereof and the scintillator can be used to detect neutrons.

Rutstrom, Daniel↗

Radiation monitoring devices and associated methods

Radiation monitoring devices and associated methods are described. According to one aspect, a radiation monitoring device includes a housing configured to pass radiation emitted from a radiological source located in proximity to the radiation monitoring device, a radiation detector configured to receive the radiation emitted from the radiological source and to generate information regarding the radiation, and communications circuitry configured to communicate the information regarding the radiation in a plurality of communications at a plurality of different moments in time externally of the radiation monitoring device.

Burghard, Brion J.↗

Cadmium Magnesium Telluride for Next-Generation X-Ray Free Electron Laser, Synchrotron, and Many Other Applications

We developed a picosecond photodetector based on our Bridgman-grown and specially engineered cadmium magnesium telluride (Cd 1–x MgxTe) single crystal that is sensitive to both optical and X-ray pulses for coarse timing in free-electron laser applications. Cd 1–x MgxTe is a widebandgap semiconductor with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma-ray radiation, thermal neutrons, and medical imaging. For femtosecond optical and X-ray crosscorrelation, the material must have a very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have a very low bulk leakage current, in the 10–90 nA range for voltages to even 1000 V. Hence, the ability to tailor or engineer the material is very crucial. Picosecond response and the crystal growth of this specially engineered Cd 1–x MgxTe material are presented. Furthermore, other characterization and transient measurements are discussed along with room-temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

Characterization of CdZnTeSe Nuclear Detector Chemically Etched in Bromine Methanol

Semiconductor nuclear radiation detectors made from tertiary and quaternary compounds of cadmium telluride (CdTe) can operate at room temperature without cryogenic cooling. One of such materials that have become of great interest is cadmium zinc telluride selenide (CdZnTeSe). Compared to other CdTe-based materials, such as cadmium zinc telluride (CdZnTe), CdZnTeSe can be grown with much less Te inclusions and sub-grain boundary networks. Chemical etching is often used to smoothen wafer surfaces during detector fabrication. This paper presents the characterization of CdZnTeSe that is chemically etched using bromine methanol solution. Infrared imaging shows that the wafer has no sub-grain boundary networks that often limit detector performance. The current-voltage (I-V) characterization experiment gave a resistivity of 4.6 × 10 10 Ω-cm for the sample. The I-V curve was linear in the ±10 to ±50 volts range. An energy resolution of 7.2% was recorded at 100 V for the 59.6-keV gamma line of 241 Am.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cadmium Magnesium Telluride for Next Generation X-Ray Free Electron Laser, Synchrotron and Many Other Applications

We developed a picosecond photodetector based on our Bridgman grown and specially engineered Cadmium Magnesium Telluride (Cd 1-x Mg x Te) single crystal that is sensitive to both optical and x-ray pulses for coarse timing in Free Electron Laser applications. Cd 1-x Mg x Te is a wide bandgap semiconductor material with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma ray radiation, thermal neutrons, and medical imaging. However, for femtosecond optical and x-ray cross correlation, the material has to have very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have very low bulk leakage current, in the 0.10 pA range. Hence the ability to tailor or engineer the material is very crucial. In this paper, picosecond response and the crystal growth of this specially engineered cadmium magnesium telluride material will be presented. Other material characterization and transient measurements will also be discussed along with room temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

Thallium Bromide Semiconductor Radiation Materials and Detectors Characterization Studies

Two overarching requirements of crucial importance for the commercial and scientific establishment of semiconductor radiation detectors are: (1) exceptionally high-purity crystals with impurity concentrations less than 1 part-per-billion and (2) single crystals that are relatively free from subgrain boundaries, secondary phases, dislocations, and other electrically-active defects. We investigated the properties of thallium bromide (TlBr) material that affect its performance with the goal of increasing the material's commercial viability for radiation detection applications. For this purpose, we used beamlines at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL), performing Micron-scale X-ray Detector Mapping, White Beam X-ray Diffraction Topography, and Micron-scale X-ray Fluorescence. These characterization methods improve the industry's understanding of TlBr and lead to the production of improved instrumentation. In this particular study we report electro-migration measurements of positive-ion Cu, Ag, and Au impurities in TlBr detectors under electric field strengths typically used for device operation. BNL improved TlBr detectors with an electrode design that corrects the response non-uniformities caused by crystal defects. This design can achieve improved energy resolution while using typical-grade, commercial crystals with relaxed quality requirements, thus reducing the overall cost of detectors. Additional characterization will be necessary to fully understand the structure and performance of TlBr with the ultimate goal to achieve the highest energy resolution. Our findings from past work will be presented along with our recommendations for additional investigation.

36 MATERIALS SCIENCE↗

Point Source Likelihood Framework (psl) v1.0

PSL is a software framework for localizing radiation point sources in a 3D environment using a freely moving radiation detector system. The framework assumes a single point source of radiation is in the environment and uses known detector positions and orientations along with their radiation measurements to find the most likely location of the point source. This approach to the problem enables analyses that improve upon the capability of a standard Maximum Likelihood Expectation Maximization (MLEM) approach, such as setting a source detection threshold, finding a likelihood interval for the position of the source, finding a likelihood interval for the activity (intensity) of the source, determining whether more than one point source may be present, and generating a map of Minimum Detectable Activity (MDA) for a given source type. Applications include radiological and nuclear security, consequence management, decontamination and decommissioning of nuclear facilities, and radiological emergency response.

Joshi, Tenzing↗

Recovery of coincident frequency domain multiplexed detector pulses using sequential deconvolution

Multiplexing of radiation detector signals into a single channel significantly reduces the need for a large number of digitizer channels, which reduces the cost and the power consumption of a data acquisition system. We previously demonstrated frequency domain multiplexing by convolution using a prototype system that multiplexed two EJ-309 organic scintillators signals into a single channel. Each detector pulse was converted to a damped sinusoid which was then combined into a single channel. The combined signal was digitized and the original detector signal was recovered from the damped sinusoid by deconvolution. In this paper, we demonstrate the recovery of multiple detector signals that arrive during the same digitized record via a new sequential deconvolution method. Here, when two detectors produce signals in the same digitized record and their pulses do not overlap in time, we found that the charge, arrival time, and particle type can be estimated fairly precisely for the first pulse, but the second pulse exhibits substantial degradation in the precision of the estimated charge and arrival time. When the pulses overlap in time, we demonstrate both theoretically and experimentally that the part of the first pulse that does not overlap with the second can be recovered accurately, so the arrival time and amplitude of the first pulse can be estimated fairly precisely, but not the charge or particle type. None of these quantities can be estimated precisely for the second pulse when the two pulses overlap.

47 OTHER INSTRUMENTATION↗

Integration of the Kromek D3S Detector and Spot Robot For Secondary Inspections

Inspecting vehicles and containers for the presence of nuclear material is a challenging task for border control and security. When performed manually by inspectors, this task also has an associated risk of exposing the inspectors to unknown radiation. With the advent of agile, easy-to-program, quadruped robots like the Boston Dynamics Spot, automation of secondary inspection can improve the efficiency of the inspection process and alleviates the radiation risks to inspectors. In this project, Brookhaven National Laboratory and the University of Massachussetts at Lowell explored how to automate a simple secondary inspection mission. The Spot robot comes with its own software development kit (SDK) that allows clients/users to write custom code in the Python programming language to control the robot. Spot also has a payload computer called Spot-CORE, which runs the Ubuntu Linux operating system and allows users to integrate external sensors, such as a radiation detector, with Spot. In this study, the Kromek D3S detector has been integrated with Spot via the Spot-CORE, allowing Spot to capture gamma spectra and neutron counts for a specified acquisition period. Two custom routines, search and confirmation, have been developed and executed in this specified order. The search routine directs Spot to go around the nearest obstacle, e.g., vehicle and container, in a preset distance and step to collect gamma and neutron gross counts with the D3S detector. The radiation data and the robot location corresponding to each step are stored and fed to the confirmation routine at the end of the search. The confirmation routine then navigates Spot to the locations of the highest gamma or neutron counts to perform a long, e.g., one minute, measurement, and gives the operators the signature gamma spectra and neutron counts at the hotspots. This paper presents a detailed description of this automated system along with results of the preliminary tests in identifying the location and signature of a 137Cs radiation source in a vehicle.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Charge carrier mobility of halide perovskite single crystals for ionizing radiation detection

Halide perovskites have recently emerged as promising semiconductor materials for several applications including solar cells, light-emitting diodes (LEDs), and radiation detectors. The charge carrier transport properties, which could be evaluated by the mobility-lifetime (mu-tau or μ-г) product, serve an important role for the development of halide perovskites for radiation detection applications. In this perspective, we firstly explain the charge transport mechanism and the limiting factors that determine the intrinsic charge carrier mobility in halide perovskite single crystals. Then, we overview the techniques and methods that have been employed for evaluating the charge carrier mobility (for both electrons and holes). Lastly, we discuss the discrepancy between the experimentally determined carrier mobility from the literature for halide perovskite single crystals and a perspective on future developments for carrier mobility enhancement is provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-of-flight experiments for nuclear structure and astrophysics

Neutron-rich isotopes are atomic nuclei with a large neutron excess compared to their stable counter parts. Their study provides essential information to understand the properties of the nuclear interaction, and to model nuclear processes in extreme astrophysical environments where neutron-rich isotopes drive the chains of nuclear reactions. Experimentally, these unstable isotopes are difficult to study because of their short half-lives and low production yields at particle accelerator laboratories. The TOF-Bρ technique is a mass measurement technique specialized for experiments with fast beams of short-lived radioactive isotopes. In this project we used the technique for two experiments performed at the National Superconducting Cyclotron Laboratory to measure new masses of isotopes in the region of 112 Mo and 46 S. The experiments at the NSCL were complemented by the development of new timing radiation detectors and experimental techniques to improve the performance and reach of mass measurements on neutron-rich isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Semi-empirical simulation of in-motion radiation detection systems

The Replicative Assessment of Spectroscopic Equipment (RASE) is an open-source software that uses experimental data as the basis to simulate the response of commercial radiation detectors to sources in various situations, particularly in the context of nuclear security and safeguards applications. Dynamic RASE introduces the capability to simulate scenarios where sources and detector are in relative motion. Position-dependent experimentally acquired gamma spectra are ingested by Dynamic RASE to build maps that describe the detector response over all space. These response maps are used to replicate the time-dependent energy spectra collected as sources move on a path near the detector. Here, a Gaussian process is used to build each map, incorporating a novel kernel adapted to the special case of radiation detection. The approach has been validated against experimental data acquired using a NaI-based detector for 137 Cs and 54 Mn sources. The capability to create accurate simulations using either long-dwell static measurements or dynamic pass-by measurements as source data has been demonstrated. Quantitative relative performance, benefits, and shortcomings are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optically induced quantum transitions in direct probed mesoscopic NbSe 2 for prototypical bolometers

Superconducting transition-edge sensors (TES) have emerged as fascinating devices to detect broadband electromagnetic radiation with low thermal noise. The advent of metallic transition metal dichalcogenides, such as NbSe 2 , has also created an impetus to understand their low-temperature properties, including superconductivity. Interestingly, NbSe 2 -based sensor within the TES framework remains unexplored. In this work, direct-probed superconducting NbSe 2 absorbers led to a proof-of-concept demonstration for the transduction of incoming light to heat, where a thermodynamic superconducting phase transition in NbSe 2 was evident to switch it to the normal-state, when biased below its superconducting transition temperature. A wavelength-dependent response of its optical absorption properties was observed, based on the incident optical excitation source used. Furthermore, extensive optical characterization studies were conducted using Raman spectroscopy, where the in-plane and out-of-plane thermal conductivity was empirically determined. Our results open new possibilities for the use of NbSe 2 in superconducting radiation detectors, including in a TES framework

47 OTHER INSTRUMENTATION↗