Search NASA⌕ Search

SEARCH · Search NASA

Results for “reflectance calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Initial vegetation species and senescience/stress indicator mapping in the San Luis Valley, Colorado using imaging spectrometer data

We analyzed AVIRIS data obtained over agricultural areas in the San Luis Valley of Colorado. The data were acquired on September 3, 1993. A combined method of radiative transfer modeling and ground calibration site reflectance was used to correct the flight data to surface reflectance. This method, called Radiative Transfer Ground Calibration, or RTGC, corrects for variable water vapor in the atmosphere and produces spectra free of artifacts with spectral channel to channel noise approaching the signal to noise of the raw data. The calibration site soil samples were obtained on the day of the overflight and measured on our laboratory spectrometer. The site was near the center of the AVIRIS scene and the spectra of the soil is spectrally bland, especially in the region of the chlorophyll absorption in the visible portion of the spectrum. The center of the scene is located at approximately 106 deg 03' longitude, 37 deg 23' latitude, and the scene covers about 92 square kilometers. This scene is one of 28 in the area for a general project to study the Summitville abandoned mine site, located in the mountains west of the San Luis Valley, and its effects on the surrounding environment.

Clark, Roger N.↗

Continuous Calibration Improvement in Solar Reflective Bands: Landsat 5 Through Landsat 8

Launched in February 2013, the Operational Land Imager (OLI) on-board Landsat 8 continues to perform exceedingly well and provides high science quality data globally. Several design enhancements have been made in the OLI instrument relative to prior Landsat instruments: pushbroom imaging which provides substantially improved Signal-to-Noise Ratio (SNR), spectral bandpasses refinement to avoid atmospheric absorption features, 12 bit data resolution to provide a larger dynamic range that limits the saturation level, a set of well-designed onboard calibrators to monitor the stability of the sensor. Some of these changes such as refinements in spectral bandpasses compared to earlier Landsats and well-designed on-board calibrator have a direct impact on the improved radiometric calibration performance of the instrument from both the stability of the response and the ability to track the changes. The on-board calibrator lamps and diffusers indicate that the instrument drift is generally less than 0.1% per year across the bands. The refined bandpasses of the OLI indicate that temporal uncertainty of better than 0.5% is possible when the instrument is trended over vicarious targets such as Pseudo Invariant Calibration Sites (PICS), a level of precision that was never achieved with the earlier Landsat instruments. The stability measurements indicated by on-board calibrators and PICS agree much better compared to the earlier Landsats, which is very encouraging and bodes well for the future Landsat missions too.

Nischal Mishra↗

Error Budget for a Calibration Demonstration System for the Reflected Solar Instrument for the Climate Absolute Radiance and Refractivity Observatory

A goal of the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is to observe highaccuracy, long-term climate change trends over decadal time scales. The key to such a goal is to improving the accuracy of SI traceable absolute calibration across infrared and reflected solar wavelengths allowing climate change to be separated from the limit of natural variability. The advances required to reach on-orbit absolute accuracy to allow climate change observations to survive data gaps exist at NIST in the laboratory, but still need demonstration that the advances can move successfully from to NASA and/or instrument vendor capabilities for spaceborne instruments. The current work describes the radiometric calibration error budget for the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. The goal of the CDS is to allow the testing and evaluation of calibration approaches, alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. The resulting SI-traceable error budget for reflectance retrieval using solar irradiance as a reference and methods for laboratory-based, absolute calibration suitable for climatequality data collections is given. Key components in the error budget are geometry differences between the solar and earth views, knowledge of attenuator behavior when viewing the sun, and sensor behavior such as detector linearity and noise behavior. Methods for demonstrating this error budget are also presented.

radiometric calibration↗

Relative radiometric calibration of LANDSAT TM reflective bands

A common scientific methodology and terminology is outlined for characterizing the radiometry of both TM sensors. The magnitude of the most significant sources of radiometric variability are discussed and methods are recommended for achieving the exceptional potential inherent in the radiometric precision and accuracy of the TM sensors.

Barker, J. L.↗

CLARREO: Reference Inter-Calibration on Orbit With Reflected Solar Spectrometer

The CLARREO approach for reference intercalibration is based on obtaining coincident highly accurate spectral reflectance and reflected radiance measurements, and establish an on-orbit reference for existing Earth viewing reflected solar radiation sensors: CERES and VIIRS on JPSS satellites, AVHRR and follow-on imagers on MetOp, and imagers on GEO platforms. The mission goal is to be able to provide CLARREO RS reference observations that are matched in space, time, and viewing angles with measurements from the aforementioned instruments, with sampling sufficient to overcome the random error sources from imperfect data matching and instrument noise. The intercalibration method is to monitor over time changes in targeted sensor response function parameters: effective offset, gain, nonlinearity, spectral degradation, and sensitivity to polarization of optics.

Lukashin, C.↗

A Traceable Ground to On-Orbit Radiometric Calibration System for the Solar Reflective Wavelength Region

This paper describes the combination of a Mie scattering spectral BSDF and BTDF albedo standard whose calibration is traceable to the NIST SIRCUS Facility or the NIST STARR II Facility. The Space-based Calibration Transfer Spectroradiometer (SCATS) sensor uses a simple, invariant optical configuration and dedicated narrow band spectral channel modules to provide very accurate, polarization-insensitive, stable measurements of earth albedo and lunar disk albedo. Optical degradation effects on calibration stability are eliminated through use of a common optical system for observations of the Sun, Earth, and Moon. The measurements from space would be traceable to SI units through preflight calibrations of radiance and irradiance at NIST's SIRCUS facility and the invariant optical system used in the sensor. Simultaneous measurements are made in multiple spectral channels covering the solar reflective wavelength range of 300 nm to 2.4 microns. The large dynamic range of signals is handled by use of single-element, highly-linear detectors, stable discrete electronic components, and a non imaging optical configuration. Up to 19 spectral modules can be mounted on a single-axis drive to give direct pointing at the Earth and at least once per orbit view of the Sun and Moon. By observing the Sun on every orbit, the most stringent stability requirements of the system are limited to short time periods. The invariant optical system for both radiance and irradiance measurements also give excellent transfer to-orbit SI traceability. Emerging instrumental requirements for remotely sensing tropospheric trace species have led to a rethinking by some of the paradigm for Systeme International d'Unites (SI) traceability of the spectral irradiance and radiance radiometric calibrations to spectral albedo (sr(exp -1)) which is not a SI unit. In the solar reflective wavelength region the spectral albedo calibrations are tied often to either the spectral albedo of a solar diffuser or the Moon. This new type of Mie scattering diffuser (MSD) is capable of withstanding high temperatures, and is more Lambertian than Spectralon(tm). It has the potential of covering the entire solar reflective wavelength region. Laboratory measurements have shown that the specular reflectance component is negligible, and indicate that internal absorption by multiple scattering is small. This MSD, a true volume diffuser, exhibits a high degree of radiometric stability which suggests that measurements at the National Institute of Standards and Technology (NIST) could provide a spectral albedo standard. Measurements have been made of its radiometric stability under a simulated space environment of high energy gamma rays, high energy protons, and UV radiation from ambient down to the vacuum ultraviolet H Lyman alpha at 121.6 nm for its eventual use in space as a solar diffuser.

Heath, Donald F.↗

On-Orbit Calibration and Performance of Aqua MODIS Reflective Solar Bands

Aqua MODIS has successfully operated on-orbit for more than 6 years since its launch in May 2002, continuously making global observations and improving studies of changes in the Earth's climate and environment. 20 of the 36 MODIS spectral bands, covering wavelengths from 0.41 to 2.2 microns, are the reflective solar bands (RSB). They are calibrated on-orbit using an on-board solar diffuser (SD) and a solar diffuser stability monitor (SDSM). In addition, regularly scheduled lunar observations are made to track the RSB calibration stability. This paper presents Aqua MODIS RSB on-orbit calibration and characterization activities, methodologies, and performance. Included in this study are characterizations of detector signal-to-noise ratio (SNR), short-term stability, and long-term response change. Spectral wavelength dependent degradation of the SD bidirectional reflectance factor (BRF) and scan mirror reflectance, which also varies with angle of incidence (AOI), are examined. On-orbit results show that Aqua MODIS onboard calibrators have performed well, enabling accurate calibration coefficients to be derived and updated for the Level 1B (L1B) production and assuring high quality science data products to be continuously generated and distributed. Since launch, the short-term response, on a scan-by-scan basis, has remained extremely stable for most RSB detectors. With the exception of band 6, there have been no new RSB noisy or inoperable detectors. Like its predecessor, Terra MODIS, launched in December 1999, the Aqua MODIS visible (VIS) spectral bands have experienced relatively large changes, with an annual response decrease (mirror side 1) of 3.6% for band 8 at 0.412 microns, 2.3% for band 9 at 0.443 microns, 1.6% for band 3 at 0.469 microns, and 1.2% for band 10 at 0.488 microns. For other RSB bands with wavelengths greater than 0.5 microns, the annual response changes are typically less than 0.5%. In general, Aqua MODIS optics degradation is smaller than Terra MODIS and the mirror side differences are much smaller. Overall, Aqua MODIS RSB on-orbit performance is better than Terra MODIS.

Xiong, Xiaoxiong↗

Optical Studies of Low Reflectance Materials at Solar Reflective Wavelengths in Support of Remote Sensing Instrument Development and Calibration

We report the Bidirectional Reflection Distribution Function (BRDF) and Total Hemispheric Reflectance (THR) results of several low reflectance materials using a Table-top Goniometer (TTG) and a commercial UV-VIS-NIR spectrophotometer in support of the NASA GSFC PACE project. The newly developed TTG was utilized to perform the BRDF measurements for several black candidate samples in in-plane and out-of-plane configurations from 300 nm to 2000 nm. These measurements demonstrated the BRDF capability of the TTG to calibrate the dim calibration target with a reflectance of approximately 2 % for the OCI of the PACE project. The spectral THR of the black samples from 200 nm to 2500 nm was determined using a 10 % reflectance diffuse black standard and a monochromator-based light source equipped with a 150 mm diameter integrating sphere. The THR measurement is used to compliment and validate the BRDF measurements acquired from these samples. In this presentation, we also show examples of UV induced BRDF and THR changes on two black coatings. We will discuss validation of the BRDF scale, source stability, measurement repeatability, instrument signature, and uncertainty components.

Bidirectional Reflection Distribution Function (BR↗

MODIS Solar Diffuser On-orbit Performance

MODIS is a key instrument for the NASA Earth Observing System (EOS), currently operated on both the Terra and Aqua missions. Each MODIS instrument has 20 reflective solar bands (RSBs) and 16 thermal emissive bands (TEBs). MODIS RSB on-orbit calibration is reflectance based using an on-board solar diffuser (SD). The SD bi-directional reflectance factors (BRFs) were characterized pre-launch using reference diffuser samples, which are traceable to NIST reflectance standards. The SD BRF on-orbit degradation (or change) is tracked by another onboard device, called the solar diffuser stability monitor (SDSM). The SDSM is operated during each scheduled SD calibration event, making alternate observations of direct sunlight and the diffusely reflected sunlight from the SD. The time series of the ratios of SDSM's SD view to its Sun view provide SD degradation information. This paper presents and compares the Terra and Aqua MODIS SD on-orbit performance. Results show that the SD on-orbit degradation depends on the amount of solar exposure of the SD plate. In addition, it is strongly wavelengthdependent, with a larger degradation rate at shorter wavelengths. For Terra MODIS, an SD door anomaly occurred in May 2003 that led to a decision to fix the door permanently at an "open" position. Since then, the SD degradation rate has significantly increased due to more frequent solar exposure. As expected, the SD on-orbit performance directly impacts the RSB calibration performance. The lessons learned from MODIS on-orbit calibration will provide useful insights into the development and operation of future SD calibration systems.

Xiong, Xiaoxiong↗

On-Orbit Performance of MODIS Solar Diffuser Stability Monitor

Moderate Resolution Imaging Spectroradiometer (MODIS) is currently operated on both the Terra and Aqua spacecraft. It collects data in 20 reflective solar bands (RSB) and 16 thermal emissive bands. MODIS RSB calibration is reflectance based via an on-board solar diffuser (SD). On-orbit changes in the SD bidirectional reflectance factor are tracked by an onboard solar diffuser stability monitor (SDSM). The SDSM functions as an independent ratioing radiometer with nine filtered detectors, covering wavelengths in the visible (VIS) and near-infrared (NIR) spectral regions. A brief overview of SDSM design functions, on-orbit operations, and performance for both Terra and Aqua MODIS is provided. In addition to the SD on-orbit degradation at different wavelengths, the changes in SDSM detector responses and their potential impact on tracking SD on-orbit degradation are examined. After more than 12 years of on-orbit operation, Aqua MODIS SD has shown degradation varying from 0.6% at 0.94 microns to 19.0% at 0.41 microns. Due to more frequent solar exposure and longer operation time, the Terra MODIS SD has experienced a much larger degradation, varying from 2.3% at 0.94 microns to 48.0% at 0.41 microns. For both Terra and Aqua MODIS, the SD has experienced more degradation at shorter wavelengths. Meanwhile, the SDSM detector responses have also experienced wavelength-dependent degradation. The largest change in the SDSM detector responses, however, occurred at longer NIR wavelengths. Since launch, the SDSM systems on both Terra and Aqua MODIS have continued their nominal operations, enabling critical parameters to be derived in support of the RSB on-orbit calibration. The calibration strategies developed for and lessons learned from MODIS SDSM operations, and a preliminary performance comparison with the S-NPP VIIRS SDSM are discussed.

MODIS↗

GOES-16 ABI Solar Reflective Channel Validation for Earth Science Application

This paper presents the validation results of GOES-16 Satellite's Advanced Baseline Imager (ABI) obtained from a reflectance-based field campaign undertaken at the Salar de Uyuni in Bolivia in June 2017. In situ ground measurements are used to characterize the surface reflectance and the atmosphere in order to constrain the radiative transfer code and predict at-sensor reflectance (also referred to as top-of-atmosphere (TOA) reflectance) to compare with concurrent GOES-16 ABI measurements. The five-day field campaign provided repeated TOA reflectance estimates, allowing assessment not only of the calibration accuracy of the ABI reflective channels 1, 2, 3, 5 and 6, but also of its stability over the duration of the campaign. The results show that the accuracy of the ABI reflective channels calibration is within specification for channels 1, 3, 5, and 6 - average biases within 2%; for channel 2 the bias is 5%. The estimated uncertainty on the derived biases is 2–2.4%. Some calibration stability issues were present in the ABI calibration at the time of the campaign: (i) a jump on the order of 2% in channels 1 and 6, coincident with an ABI solar calibration event, reflects an instability of the ABI gains in these channels, and (ii) short-term variability in channels 1 and 2 is due to striping (ABI detector-todetector calibration differences). Continued validation and subsequent reprocessing of ABI reflectance imagery would allow Earth scientists to fully benefit from the high spatial and spectral fidelity of the GOES-16 ABI diurnal measurements at the continental scale.

Joel McCorkel↗

TPSAS-NF1676L-17894-DND

Are domain-aggregated, long-term climate trends in retrieved reflected solar cloud properties detectable despite instrument related and algorithm-related aliasing errors? Science Question: By how much do changes in instrument calibration distort reflected solar cloud property decadal trends? Objective: Quantify how changes in calibration error feed into cloud property changes. Science Question: By how much do reflected solar cloud property retrieval assumptions distort trends in retrieved cloud properties? Objective: Quantify how the plane-parallel assumption in reflected solar satellite cloud retrievals distorts cloud optical thickness decadal trends by determining how and if the large-scale 3D optical thickness bias changes over time. - The three panel procedure below will be performed for each time (month), (zonal) region, set of solar and viewing geometries.

Yolanda Roberts↗

Multispectral Analysis of the Kasei Vallis-lanae Planum Region of Mars

The surficial geology of the Kasei Vallis - Lunae Planum region of Mars was investigated using the three color Viking Orbiter 1 data. Spatial resolution is 820m and Ls = 100 deg, a season of low atmospheric and and surface dustiness. This region was chosen for high quality color and thermal inertia data as well as for the diversity of volcanic plains and fluvial landform. The data was reformatted to Mercator projection and calibrated to normal reflectance using in flight calibration parameters and observed photometric properties. Color properties from this image are displayed in two forms: the Red Albedo vs. Violet Albedo two dimensional histogram, and representative 3 point spectra. Virtually the full range of regolith color properties known from prior research is represented, plus some new characteristics. Interpretations of the data are presented which address general composition and formation processes of channel and intracrater deposits.

Singer, R. B.↗

Reflectance stability analysis of Spectralon diffuse calibration panels

The Multi-angle Imaging SpectroRadiometer (MISR) plans to use deployable diffuse reflectance panels to provide periodic radiometric calibrations of its nine cameras while in-flight. Near-Lambertian reflectance characteristics are desirable to facilitate flat-field camera intercomparisons. Also required is panel spatial and spectral uniformity, and stability with time. Spectralon, a commercially available polytetrafluoroethylene (PTFE) compound, has been baselined in the MISR design. To assess the suitability of this material, a series of degradation tests were planned and implemented. These included UV vacuum exposure and proton bombardment tests which simulated the exposure levels to be encountered during the mission life. Proton levels are now considered too low to be of concern, but UV vacuum tests demonstrate sensitivity to material contamination. Material investigations have concluded that hydrocarbons are present in the bulk of the material, and that plastic packaging materials can introduce additional surface-layer contamination. It is found however, that these unwanted elements can be eliminated through vacuum pumping at elevated temperatures. Exposure to a UV source, while in vacuum, is again planned for a set of targets which have been vacuum baked. This will assess the stability of the pure PTFE form.

Bruegge, Carol J.↗

Modeling Spectralon's Bidirectional Reflectance for In-flight Calibration of Earth-Orbiting Sensors

The in-flight calibration of the EOS Multi-angle Imaging SpectroRadiometer (MISR) will be achieved, in part, by observing deployable Spectralon panels. This material reflects light diffusely, and allows all cameras to view a near constant radiance field. This is particularly true when a panel is illuminated near the surface normal. To meet the challenging MISR calibration requirements, however, very accurate knowledge of the panel reflectance must be known for all utilized angles of illumination, and for all camera and monitoring photodiode view angles. It is believed that model predictions of the panels Bidirectional Reflectance Distribution Function (BRDF) can be used in conjunction with a measurements program to provide the required characterization. This paper describes the results of a model inversion which was conducted using measured Spectralon BRDF data at several illumination angles. Four physical parameters of the material were retrieved, and are available for use with the model to predict reflectance for any arbitrary illumination or view angle. With these data the root mean square difference between the model and the observations is currently of the order of the noise in the data, at about +/- l%. With this success the model will now be used in a variety of future studies, including the development of a measurements test plan, the validation of these data, and the prediction of a new BRDF profile, should the material degrade in space.

Flasse, Stephane P.↗

Initial On-Orbit Radiometric Calibration of the Suomi NPP VIIRS Reflective Solar Bands

The on-orbit radiometric response calibration of the VISible/Near InfraRed (VISNIR) and the Short-Wave InfraRed (SWIR) bands of the Visible/Infrared Imager/Radiometer Suite (VIIRS) aboard the Suomi National Polar-orbiting Partnership (NPP) satellite is carried out through a Solar Diffuser (SD). The transmittance of the SD screen and the SD's Bidirectional Reflectance Distribution Function (BRDF) are measured before launch and tabulated, allowing the VIIRS sensor aperture spectral radiance to be accurately determined. The radiometric response of a detector is described by a quadratic polynomial of the detector?s digital number (dn). The coefficients were determined before launch. Once on orbit, the coefficients are assumed to change by a common factor: the F-factor. The radiance scattered from the SD allows the determination of the F-factor. In this Proceeding, we describe the methodology and the associated algorithms in the determination of the F-factors and discuss the results.

Lei, Ning↗

An Overview of MODIS On-orbit Operation, Calibration, and Lessons

Two nearly identical copies of the Moderate Resolution Imaging Spectroradiometer (MODIS) have successfully operated onboard the Terra and Aqua spacecraft for more than II years and 9 years since their launch in December 1999 and May 2002, respectively. MODIS is a key instrument for the NASA's Earth Observing System (EOS) missions. MODIS observations have produced an unprecedented amount and a broad range of data products and significantly benefited the science and user community. Its follow-on instrument, the Visible/Infrared Imager Radiometer Suite (VIIRS) on-board the NPOESS Preparatory Project (NPP) spacecraft, is currently scheduled for launch in late October, 2011. The NPP serves as a bridge mission between EOS and the Joint Polar Satellite System (JPSS). MODIS collects data in 36 spectral bands, covering spectral regions from visible (VIS) to long-wave infrared (L WIR), and at three different spatial resolutions. Because of its stringent design requirements, MODIS was built with a complete set of onboard calibrators, including a solar diffuser (SO), a solar diffuser stability monitor (SDSM), a blackbody (BB), a spectroradiometric calibration assembly (SRCA), and a space view (SV) port. Except for tbe SRCA, VIlRS carries the same set of onboard calibrators as MODIS. The SD/SDSM system is used together to calibrate tbe reflective solar bands (RSB). The BB is designed for the thermal emissive bands (TEB) calibration. Similar to Terra and Aqua MODIS, VIlRS will also make regular lunar observations to monitor RSB radiometric calibration stability. In this paper, we provide an overview of MODIS on-orbit operation and calibration activities and present issues identified and lessons learned from mission-long instrument operations and implementation of various calibration and characterization strategies. Examples of both Terra and Aqua MODIS instrument on-orbit performance, including their similarities and unique characteristics, are discussed in tbe context of what might be expected from and benefited to tbe NPP VIlRS operation and calibration. It is anticipated that MODIS experience and lessons will also provide valuable information for other earth observing missions/sensors.

Xiong, Jack↗