Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Use of Fisher's Ratio assisted multivariate curve resolution- alternating least squares for discovery-based analysis using ultrahigh pressure liquid chromatography-high resolution mass spectrometry

Non-targeted analysis of complex chemical mixtures can be difficult considering the convoluted nature of the matrix and the potential unknown chemical differences between samples or classes of samples. Ultrahigh pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) is an ideal technique to probe chemical differences for a wide variety of samples. While UHPLC-QTOF can discover minute chemical differences down to low part per billion (ppb) concentrations with a high degree of confidence, the application of high-resolution mass spectrometry can yield massive amounts of information (∼ 10 gb per sample) that cannot be analyzed manually. Therefore, the application of chemometric techniques is mandatory for the interrogation of complex samples. Fisher's ratio (FR) assisted multivariate curve resolution-alternating least squares (MCR-ALS) was used to the discover and identify the chemical differences between two classes of materials: 1) a pond water matrix and 2) the matrix spiked with a pharmaceutical standard mix containing 17 compounds. Thirteen of the seventeen spiked compounds were discovered using FR analysis, and then five were successfully deconvoluted using MCR-ALS wherein the number of curves chosen were automatically determined using singular value decomposition (SVD). In conclusion, the use of an automated FR assisted MCR-ALS will aid in discovering trace levels of chemical components without the need for the researcher to provide potentially biased input which will aid in non-targeted workflow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multidimensional Distributional Neural Network Output Demonstrated in Super‐Resolution of Surface Wind Speed

Accurate quantification of uncertainty in neural network predictions remains a central challenge for scientific applications involving high-dimensional, correlated data. While existing methods capture either aleatoric or epistemic uncertainty, few offer closed-form, multidimensional distributions that preserve spatial correlation while remaining computationally tractable. In this work, we present a framework for training neural networks with a multidimensional Gaussian loss, generating a closed-form predictive distribution over outputs informed by non-identically distributed training data. Our approach captures aleatoric uncertainty by iteratively estimating the means and covariance matrices, and is demonstrated on a super-resolution example out-of-training-sample. We leverage a Fourier representation of the covariance matrix to stabilize network training and preserve spatial correlation. We introduce a novel regularization strategy—referred to as information sharing—that interpolates between image-specific and global covariance estimates, enabling convergence of the super-resolution downscaling network trained on image-specific distributional loss functions. This framework allows for efficient sampling, explicit correlation modeling, and extensions to more complex distribution families all without disrupting prediction performance. We demonstrate the method on a surface wind speed downscaling task and discuss its broader applicability to uncertainty-aware prediction in scientific models.

17 WIND ENERGY↗

Analyzer-free linear dichroic ptychography

Linear dichroism is an important tool to characterize the transmission matrix and determine the crystal or orbital orientation in a material. To achieve high-resolution mapping of transmission properties, we introduce the linear-dichroism scattering model in ptychographic imaging and develop an efficient two-stage reconstruction algorithm. Using the proposed algorithm on a uniaxial material, the dichroic transmission matrix can be recovered without an analyzer by using ptychography measurements with as few as three different polarization angles, with the help of an empty region to remove phase ambiguities.

97 MATHEMATICS AND COMPUTING↗

A solid-state extrusion pathway extensible to upcycling aluminum scrap and end-of-life permanent magnets into ductile Al-6061/SmCo 5 structural magnetic composites

Permanent magnets offer strong potential for multifunctional structural components, but their inherent brittleness limits direct integration. Here, SolidStir® Extrusion (SSE) is used to embed SmCo5 powder into AA6061 in the solid state, and the resulting microstructure, interfacial chemistry, mechanical properties, and magnetic response are systematically characterized. SSE fragments the initial SmCo 5 powder into predominantly fine particles dispersed within an ultrafine Al matrix, with a volume fraction of ∼ 4–6 % in this proof-of-concept study. Interfacial reactions form a continuous Al–Co reaction layer, with local atomic-resolution indexing consistent with Al 13 Co 4 , together with Sm–Si-rich reaction products, while the matrix contains Sm–Co–Si-rich precipitates and Mg 2 Si, producing features from nanometers to micrometers. Compared with an Al extrudate, this architecture increases yield strength by ∼ 42 % and tensile strength by ∼ 31 %, while preserving uniform elongation, and it sustains work hardening in compression from 150 to 400 °C. The composite retained hard-magnetic behavior, with axial magnetization of 12.7 A·m 2 kg −1 at 6 T and intrinsic coercivity of 9.6 kOe. These findings demonstrate that SSE can produce Al-based load-bearing magnetic composites while preserving useful SmCo5 functionality.

36 MATERIALS SCIENCE↗

Time-resolved lidar fluorosensor for sea pollution detection

A contemporary time and spectral analysis of oil fluorescence is useful for the detection and the characterization of oil spills on the sea surface. Nevertheless the fluorosensor lidars, which were realized up to now, have only partial capability to perform this double analysis. The main difficulties are the high resolution required (of the order of 1 nanosecond) and the complexity of the detection system for the recording of a two-dimensional matrix of data for each laser pulse. An airborne system whose major specifications were: time range, 30 to 75 ns; time resolution, 1 ns; spectral range, 350 to 700 nm; and spectral resolution, 10 nm was designed and constructed. The designed system of a short pulse ultraviolet laser source and a streak camera based detector are described.

Ferrario, A.↗

Focused‐beam X‐ray fluorescence and diffraction microtomographies for mineralogical and chemical characterization of unsectioned extraterrestrial samples

Abstract This study describes the application of new synchrotron X‐ray fluorescence (XRF) and diffraction (XRD) microtomographies for the 3‐D visualization of chemical and mineralogical variations in unsectioned extraterrestrial samples. These improved methods have been applied to three compositionally diverse chondritic meteorite samples that were between 300 and 400 μm in diameter, including samples prepared from fragments of the CR2 chondrite LaPaz Icefield (LAP) 02342, H5 chondrite MacAlpine Hills (MAC) 88203, and the CM2 chondrite Murchison. The synchrotron‐based XRF and XRD tomographies used are focused‐beam techniques that measure the intensities of fluorescent and diffracted X‐rays in a sample simultaneously during irradiation by a high‐energy microfocused incident X‐ray beam. Measured sinograms of the emitted and diffracted intensities were then tomographically reconstructed to generate 2‐D slices of XRF and XRD intensity through the sample, with reconstructed pixel resolution of 1–2 μm, defined by the resolution of the focused incident X‐ray beam. For sample LAP 02342, primary mineral phases that were visualized in reconstructed slices using these techniques included isolated grains of α‐Fe, orthopyroxene, and olivine. For our sample of MAC 88203, XRF/XRD tomography allowed visualization of forsteritic olivine as a primary mineral phase, a vitrified fusion crust at the sample surface, identification of localized Cr‐rich spinels at spatial resolutions of several micrometers, and imaging of a plagioclase‐rich glassy matrix. In the sample of Murchison, major identifiable phases include clinoenstatite‐ and olivine‐rich chondrules, variable serpentine matrix minerals and small Cr‐rich spinels. Most notable in the tomographic analysis of Murchison is the ability to quantitatively distinguish and visualize the complex mixture of serpentine‐group minerals and associated tochilinite–cronstedtite intergrowths. These methods provide new opportunities for spatially resolved characterization of sample texture, mineralogy, crystal structure, and chemical state in unsectioned samples. This provides researchers an ability to characterize such samples internally with minimal disruption of sample micro‐structures and chemistry, possibly without the need for sample extraction from some types of sampling and capture media.

Geochemistry & Geophysics↗

New Measurements of the Lyα Forest Continuum and Effective Optical Depth with LyCAN and DESI Y1 Data

Abstract We present the Ly α Continuum Analysis Network (LyCAN), a convolutional neural network that predicts the unabsorbed quasar continuum within the rest-frame wavelength range of 1040–1600 Å based on the red side of the Ly α emission line (1216–1600 Å). We developed synthetic spectra based on a Gaussian mixture model representation of nonnegative matrix factorization (NMF) coefficients. These coefficients were derived from high-resolution, low-redshift ( z < 0.2) Hubble Space Telescope/Cosmic Origins Spectrograph (COS) quasar spectra. We supplemented this COS-based synthetic sample with an equal number of DESI Year 5 mock spectra. LyCAN performs extremely well on testing sets, achieving a median error in the forest region of 1.5% on the DESI mock sample, 2.0% on the COS-based synthetic sample, and 4.1% on the original COS spectra. LyCAN outperforms principal component analysis (PCA) and NMF-based prediction methods using the same training set by 40% or more. We predict the intrinsic continua of 83,635 DESI Year 1 spectra in the redshift range of 2.1 ≤ z ≤ 4.2 and perform an absolute measurement of the evolution of the effective optical depth. This is the largest sample employed to measure the optical depth evolution to date. We fit a power law of the form τ ( z ) = τ 0 ( 1 + z ) γ to our measurements and find τ 0 = (2.46 ± 0.14) × 10 −3 and γ = 3.62 ± 0.04. Our results show particular agreement with high-resolution, ground-based observations around z = 2, indicating that LyCAN is able to predict the quasar continuum in the forest region with only spectral information outside the forest.

79 ASTRONOMY AND ASTROPHYSICS↗

Theoretical studies of Resonance Enhanced Stimulated Raman Scattering (RESRS) of frequency doubled Alexandrite laser wavelength in cesium vapor

The third phase of research will focus on the propagation and energy extraction of the pump and SERS beams in a variety of configurations including oscillator structures. In order to address these questions a numerical code capable of allowing for saturation and full transverse beam evolution is required. The method proposed is based on a discretized propagation energy extraction model which uses a Kirchoff integral propagator coupled to the three level Raman model already developed. The model will have the resolution required by diffraction limits and will use the previous density matrix results in the adiabatic following limit. Owing to its large computational requirements, such a code must be implemented on a vector array processor. One code on the Cyber is being tested by using previously understood two-level laser models as guidelines for interpreting the results. Two tests were implemented: the evolution of modes in a passive resonator and the evolution of a stable state of the adiabatically eliminated laser equations. These results show mode shapes and diffraction losses for the first case and relaxation oscillations for the second one. Finally, in order to clarify the computing methodology used to exploit the speed of the Cyber's computational speed, the time it takes to perform both of the computations previously mentioned to run on the Cyber and VAX 730 must be measured. Also included is a short description of the current laser model (CAVITY.FOR) and a flow chart of the test computations.

Lawandy, Nabil M.↗

Error analysis applied to several inversion techniques used for the retrieval of middle atmospheric constituents from limb-scanning MM-wave spectroscopic measurements

The formal retrieval error analysis of Rodgers (1990) allows the quantitative determination of such retrieval properties as measurement error sensitivity, resolution, and inversion bias. This technique was applied to five numerical inversion techniques and two nonlinear iterative techniques used for the retrieval of middle atmospheric constituent concentrations from limb-scanning millimeter-wave spectroscopic measurements. It is found that the iterative methods have better vertical resolution, but are slightly more sensitive to measurement error than constrained matrix methods. The iterative methods converge to the exact solution, whereas two of the matrix methods under consideration have an explicit constraint, the sensitivity of the solution to the a priori profile. Tradeoffs of these retrieval characteristics are presented.

Puliafito, E.↗

Active region seismology

Active region seismology is concerned with the determination and interpretation of the interaction of the solar acoustic oscillations with near-surface target structures, such as magnetic flux concentration, sunspots, and plage. Recent observations made with a high spatial resolution and a long temporal duration enabled measurements of the scattering matrix for sunspots and solar active regions to be carried out as a function of the mode properties. Based on this information, the amount of p-mode absorption, partial-wave phase shift, and mode mixing introduced by the sunspot, could be determined. In addition, the possibility of detecting the presence of completely submerged magnetic fields was raised, and new procedures for performing acoustic holography of the solar interior are being developed. The accumulating evidence points to the mode conversion of p-modes to various magneto-atmospheric waves within the magnetic flux concentration as being the unifying physical mechanism responsible for these diverse phenomena.

Bogdan, Tom↗

AGR-5/6/7 Fuel Fabrication Report

The U.S. Department of Energy Office of Nuclear Energy (DOE NE) and the Idaho National Laboratory (INL) Advanced Reactor Technologies (ART) Advanced Gas Reactor (AGR) Fuel Development and Qualification program (referred to as AGR Fuel program hereafter) are pursuing qualification of tristructural isotropic (TRISO) coated particle fuel for use in high temperature gas cooled reactors (HTGRs). The AGR Fuel program was established to provide a fuel qualification data set in support of the licensing and operation of an HTGR. BWX Technologies Nuclear Operations Group (BWXT-NOG) was subcontracted to fabricate the fuel for the AGR program. Several investments and innovations were realized in preparation to fabricate fuel for the AGR-5/6/7 irradiation experiments that brought fuel fabrication fully out of the laboratory and into engineering-scale operations. These included: • Increased the kernel fabrication line capacity and uniformity • Upgraded ancillary support equipment and processes for the tristructural isotropic (TRISO) coating furnace • Demonstrated efficient production of the matrix precursor powder by dry jet milling of co mingled components • Demonstrated an engineering-scale method for quick and efficient overcoating TRISO particles with the matrix precursor • Demonstrated an automated, multi cavity compacting system with a volumetric feed system • Demonstrated a combined-cycle thermal treatment furnace These changes increased production rates of some of these processes by an order of magnitude or more while eliminating the use of flammable solvents, multiple grinding and sorting operations, and the weighing out of individual die charges. Three fuel kernel lots were fabricated for production of the fuel for AGR-5/6/7. The initial lot (J52R-16-39316) was certified to fuel specifications but was not used because the kernels had a high fraction of internal fissures that caused an unacceptable fraction of the kernels to fragment when charged to the coating furnace where the TRISO coating would be deposited. Fragmented kernels increased the dispersed uranium in the particles and produced a worrisome fraction of dimpled particles with an elevated probability of in-pile failure. After some efforts to identify the cause of the fissure formation, two additional lots were produced with much lower fissure fractions, J52R-16-69317 and 69318. The latter kernel lot was a backup to the first and was not needed. Multiple kernel batches were composited to form each of the lots so as to simulate a commercial-scale operation where kernel batches would also be composited. Multiple TRISO coating runs were performed and the product characterized so that several could be composited into a TRISO lot. TRISO lot J52R-16-98005 conformed to all fuel specifications except the mean outer pyrocarbon (OPyC) layer thickness was thinner than specified. Furthermore, it was determined that the TRISO lot had a dispersed uranium fraction (DUF) that might result in the compacts not meeting the DUF specification. A review of the role of the OPyC layer and consequences of the DUF by the Technical Coordination Team and INL concluded that the fuel was acceptable for use in the AGR-5/6/7 irradiation experiment. The TRISO particles were overcoated with the matrix precursor that had been produced in a jet-milling operation. The overcoating was performed in equipment originally designed to coat pharmaceuticals. The overcoating process performed well; producing highly spherical and uniform overcoats requiring little upgrading and no recycle or rework. TRISO particles were overcoated with the matrix precursor to achieve nominal volumetric packing fractions (PFs) of TRISO particles of 25% and 40% for the irradiation experiments. The 40% PF compacts occupy the first and fifth test capsule in the test train while the inner three capsules are loaded with 25% PF compacts. The resinated graphite matrix precursor powder was a derivative of the German A3-27 matrix formulation, which differs from previous AGR irradiation campaigns that used an A3-3 formulation. Jet milling of the matrix powder precursor produced a finer mean graphite particle size than the milling operations used for the A3-3 matrix powder precursor. Changes made in the matrix formula and equipment yielded compacts with significantly higher matrix density than was attained in previous AGR irradiation campaigns. The changes in the matrix formulation and the means of milling the powders also complicated resolution of the three fuel compact defect fractions, DUF, exposed kernel fraction (EKF), and the silicon carbide defect fraction (SDF). Characterization data from BWXT-NOG had some anomalous results, so samples of the fuel compacts and overcoated TRISO particles were also analyzed by Oak Ridge National Laboratory (ORNL) to ensure that the defect fractions were accurately characterized.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm &#x00d7; 5mm &#x00d7; 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 &#x00d7; 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

IsoMatchMS : Open-Source Software for Automated Annotation and Visualization of High Resolution MALDI-MS Spectra

Due to its speed, accuracy, and adaptability to various sample types, matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has become a popular method to identify molecular isotope profiles from biological samples. Often MALDI-MS data do not include tandem MS fragmentation data, and thus the identification of compounds in samples requires external databases so that the accurate mass of detected signals can be matched to known molecular compounds. Most relevant MALDI-MS software tools developed to confirm compound identifications are focused on small molecules (e.g., metabolites, lipids) and cannot be easily adapted to protein data due to their more complex isotopic distributions. Here, we present an R package called IsoMatchMS for the automated annotation of MALDI-MS data for multiple datatypes: intact proteins, peptides, and glycans. This tool accepts already derived molecular formulas or, for proteomics applications, can derive molecular formulas from a list of input peptides or proteins including proteins with post-translational modifications. In conclusion, visualization of all matched isotopic profiles is provided in a highly accessible HTML format called a trelliscope display, which allows users to filter and sort by several parameters such as match scores and the number of peaks matched. IsoMatchMS simplifies the annotation and visualization of MALDI-MS data for downstream analyses.

47 OTHER INSTRUMENTATION↗

Multi-scale imaging of high-pressure hydrogen induced damage in EPDM rubber using X-ray microcomputed tomography, helium-ion microscopy and transmission electron microscopy

Ethylene propylene diene (EPDM) rubber has gained increasing interest for use in hydrogen infrastructure due to its excellent sealing performance and low temperature properties. However, severe structural damage has been observed in EPDM O-rings after exposure to high-pressure hydrogen. The origination and propagation mechanisms of this damage are poorly understood. Here, to address this knowledge gap, multi-scale imaging leveraging X-ray micro-computed tomography (micro-CT), helium ion microscopy (HeIM), and transmission electron microscopy (TEM) were used in this work to study a series of sulfur-cured ethylene propylene diene (EPDM) rubber materials with varying additives that were exposed to different hydrogen environments. Micro-CT captured the substantial structural damage due to hydrogen exposure; it revealed an association between zinc oxide (ZnO) particles and damage initiation. Further studies by TEM and scanning TEM with energy dispersive X-ray spectroscopy (EDS) were focused on these particles at the micro-to nano-scale range. TEM indicated that hydrogen causes void formation at the interface between ZnO and the rubber matrix. HeIM enabled imaging of surface morphology of the material at high resolution pre- and post-hydrogen exposure while providing information on chemical composition and that cannot be captured by either micro-CT or TEM.

08 HYDROGEN↗

Low-energy physics of isotropic spin-1 chains in the critical and Haldane phases

Using a matrix product state algorithm with infinite boundary conditions, we compute high-resolution dynamic spin and quadrupolar structure factors in the thermodynamic limit to explore the low-energy excitations of isotropic bilinear-biquadratic spin-1 chains. Haldane mapped the spin-1 Heisenberg antiferromagnet to a continuum field theory, the nonlinear sigma model (NLσM). In this work, we find that the NLσM fails to capture the influence of the biquadratic term and provides only an unsatisfactory description of the Haldane phase physics. But several features in the Haldane phase can be explained by noninteracting multimagnon states. The physics at the Uimin-Lai-Sutherland point is characterized by multisoliton continua. Moving into the extended critical phase, we find that these excitation continua contract, which we explain using a field-theoretic description. New excitations emerge at higher energies and, in the vicinity of the purely biquadratic point, they show simple cosine dispersions. Using block fidelities, we identify them as elementary one-particle excitations and relate them to the integrable Temperley-Lieb chain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated photonic Galton board and its application for photon counting

The Galton board is a desktop probability machine traditionally used to visualize the principles of statistical physics from classical particles. Here, we demonstrate a photonic Galton board that enables on-chip observation of statistics from single-photon interference. The photonic Galton board consists of a directional coupler matrix terminated by an array of superconducting nanowire detectors to provide spatiotemporal resolution. This design also allows for photon-number-resolving capability, making it suitable for high-speed photon counting. Our results demonstrate the compatibility between single-photon detector array and photonic integrated circuits, paving the way for implementing on-chip large-scale quantum optics experiments and photonic quantum computing.

Qin, Hezheng (ORCID:0009000139348800)↗