Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample collections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Hybridization capture sequencing for Vibrio spp. and associated virulence factors

ABSTRACT Proliferation ofVibriospp. in aquatic ecosystems is associated with climate change and, concomitantly, increased incidence of vibriosis. They are autochthonous to aquatic environments globally, but traditional metagenomic methods for detecting and typing pathogenicVibriospp. are challenged by their presence in relatively low abundance and ability to persist in a viable but nonculturable state. In the study reported here, hybridization capture sequencing (HCS) was employed to profile low-abundanceVibriospp. in environmental samples. The HCS panel targeted a family of molecular chaperones (CPN60) specific to 69Vibriospp. and 162Vibrio-specific virulence factors. This approach was evaluated in parallel with traditional whole-community shotgun sequencing in a metagenomic analysis of water and oyster samples collected from the Chesapeake Bay. In addition,Vibrio parahaemolyticusandVibrio vulnificusstrains isolated from the samples were subjected to whole-genome sequencing to determine the genetic characteristics of pathogenicVibriospp. circulating in an aquatic environment. HCS, employed to determine the incidence and characterization of specificVibriospp., yielded significantly greater metagenomic insight, notably a variety of otherVibriospp., including detection ofVibrio cholerae,Vibrio fluvialis, andVibrio aestuarianus, in addition toVibrio parahaemolyticusandVibrio vulnificus, and also important virulence factors not detectable using traditional molecular methods. Thus, pathogenicVibriospp. in aquatic ecosystems may be far more common than currently understood. It is concluded that environmental surveillance should include HCS, a valuable tool for the detection and characterization of pathogenic agents in aquatic ecosystems, notably vibrios. IMPORTANCE The increasing prevalence of pathogenicVibriospp. in aquatic ecosystems, driven by climate change, is closely linked to a rise in cholera and vibriosis cases, emphasizing the need for improved environmental surveillance. Vibrios are naturally occurring in aquatic environments globally, but traditional metagenomic methods for detecting and typing pathogenicVibriospp. are challenged by their presence in relatively low abundance and ability to persist in a viable but nonculturable state. In the study reported here, hybridization capture sequencing was employed to profile low-abundanceVibriospp. in metagenomic samples, namely water and oysters collected from the Chesapeake Bay. This approach was evaluated in parallel with traditional whole-community shotgun sequencing and whole-genome sequencing ofVibrio parahaemolyticusandVibrio vulnificusstrains isolated from the samples. Results suggest pathogenicVibriospp. in aquatic ecosystems may be far more common than currently understood, when multiple methods are considered for environmental surveillance.

Microbiology↗

Evaluating the feasibility of LA-ICP-TOF-MS for the analysis of environmental particle collections

Laser ablation-inductively coupled plasma-time-of-flight-mass spectrometry (LA-ICP-TOF-MS) was employed to rapidly analyze environmental particle samples collected using aerosol contaminate extractors (ACE). The ACE particle collectors were placed at various distances (0.5, 1.3, and 4.5 km) from a source that released Ru-bearing particles. Samples for measurement were then generated (as sub-samples) from the ACE collection plates via particle “lift off” with gunshot residue (GSR) tabs. The LA-ICP-TOF-MS method was employed such that 10+ samples could be analyzed in a single unattended analytical session. A 3 × 1 mm area of individual GSR tab samples were analyzed in less than 30 minutes. This provided spatially resolved elemental and isotopic measurements of the particulate content and confirmed the presence of Ru-bearing particles within the complex background environmental particle loading. As anticipated, measurements showed collectors closest to the source had the highest concentration of the released Ru-bearing particles, while all collectors, regardless of distance, contained similar levels of background particles (e.g., Fe and Sr). Sequential scanning electron microscopy – automated particle analysis (SEM-APA) and LA-ICP-TOF-MS analysis was employed for method validation and a demonstration of the multi-modal approach. The same 2-dimensional region was analyzed by both methods and the particles identified via SEM-APA were also detected using LA-ICP-TOF-MS, with 100% accuracy. Overall, LA-ICP-TOF-MS demonstrated its utility for rapid elemental and isotopic particle analysis from environmental air samples.

Manard, Benjamin T. [Oak Ridge National Laboratory↗

Spatial Study 2022: Water Column, Sediment, and Total Ecosystem Respiration Rates across the Yakima River Basin, Washington, USA (v2)

This dataset supports a broader study examining the drivers of spatial variability in sediment respiration rates in the Yakima River Basin and is associated with the manuscript “Sediment-associated processes account for most of the spatial variation in ecosystem respiration in the Yakima River basin” submitted to Nature Communications Earth & Environment (Garayburu-Caruso et al., in review). The dataset provides ecosystem metabolism estimates generated from streamMetabolizer (Appling et al.; 2018) using data collected during the same five-week period at 48 sites within multiple rivers throughout the Yakima River Basin in Washington, USA. Additionally, it includes the scripts used for the analysis and producing the figures in the manuscript. The contents include streamMetabolizer inputs and outputs and additional relevant data needed to generate the main manuscript results. The data included are: total ecosystem respiration, water respiration, calculated sediment-associated respiration, gross primary production outputs from the river corridor model for the Yakima River Basin, median grain size (d50), depth, dissolved oxygen, water temperature, pressure, and annual oxygen consumption. The associated GitHub repository can be found at https://github.com/river-corridors-sfa/SSS_metabolism. Samples collected during this study were labeled as “Second Spatial Study” or “SSS.” Raw time series sensor data, total suspended solids, and depth data from SSS were published at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1969566. A subset of data from the SSS samples were published in the contiguous United States (CONUS)-Scale Model-Sample (CM) study data package available at https://data.ess-dive.lbl.gov/view/doi:10.15485/1923689 that presents data from across the CONUS. They include dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC), total nitrogen (TN), grain size, aerobic sediment respiration, dissolved oxygen (DO), and temperature. Parent IDs and Site IDs are consistent between the SSS and CM data packages, and they can be mapped directly so data across packages can be used together. Field metadata for the samples in this da This dataset is comprised of one main data folder with four subfolders. The main data folder contains of (1) file-level metadata; (2) data dictionary; (3) total/water column/sediment respiration; (4) gross primary production (GPP); (5) median grain size (d50); and (6) annual oxygen consumption. The “Figures” subfolder contains the figures used in the paper and all intermediate files (including geospatial files). The “Published_Data” contains a readme directing the user to download the public data to reproduce analyses and figures. The “Scripts” folder contains all scripts used in the analyses that were not part of running StreamMetabolizer. Lastly, the “Stream_Metabolizer” folder contains all files associated with running StreamMetabolizer including (1) model input files, (2) model output files, (3) processing scripts, (4) histogram plots of the outputs, and (5) an R project. All files are .csv, .pdf, .R, .Rmd, .Rproj, .html, .png, .txt, .qgz, .cpg, .dbf, .prj, .shp, .shp.ea.iso.xml, .shp.iso.xml, .shx, .sbn. ta package can be found at either link. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Temporal Study 2021-2022: Sample-Based Surface Water Chemistry and Organic Matter Characterization across Watersheds in the Yakima River Basin, Washington, USA (v3)

This dataset supports a broader study examining the drivers of temporal variability in sediment respiration rates in the Yakima River Basin. The dataset provides geochemistry and organic matter characterization data generated from samples collected at weekly or bi-weekly intervals at six sites across the Yakima River Basin in Washington, USA. Related sensor data will be published separately and can be used to link sediment respiration rates to biogeochemical processing rates. The data package was originally published in November 2022. It was updated in November 2023 (v2; modified files) and April 2025 (new and modified files). See the change history section in readme for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) dissolved inorganic carbon (DIC), dissolved organic carbon (DOC; reported as non-purgeable organic carbon; NPOC), total nitrogen (TN), total suspended solids (TSS), and ions; (5) averaged values from water chemistry data; (6) surface water sampling protocol; (7) sensor protocol; (8) readme; (9) methods codes; (10) international generic sample number (IGSN) mapping file; and (11) folder of high resolution characterization of organic via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). This folder contains two subfolders, one containing the .xml data files and the other containing instructions for using Formularity (https://omics.pnl.gov/software/formularity) and an R script to process the data based on the user's specific needs. All files are .csv, .pdf, .R, .ref, or .xml. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected our data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Samoa Updater: An Application of the Levenberg-Marquardt Method to Update DELFIC Predictions Using Field Measurements

The US Department of Energy (DOE) Forensics Operations (DFO) is a member of the Ground Collections Task Force (GCTF), which is responsible for sample collection of radiological debris for attribution should a nuclear detonation ever occur in the United States. The DFO runs the Defense Land Fallout Interpretive Code (DELFIC) Fallout Planning Tool to predict the deposition of fallout from a nuclear detonation. This prediction is refined using the DELFIC Updater tool, which takes ground measurements and adjusts DELFIC inputs to minimize the difference between prediction and observation, yielding improved predictions of fallout in locations both measured and not yet measured. Samoa, a framework for uncertainty analysis and optimization, is used to improve DELFIC predictive fallout modeling. This new capability using Samoa, dubbed “Samoa Updater,” is compared with the current DELFIC Updater, a brute-force sampling approach. Samoa Updater uses the Levenberg– Marquardt (LM) method, a gradient-based nonlinear least squares approach that uses the functional shape of the input space to increase optimization speed. In simulated test cases Samoa Updater yields faster and more accurate solutions than the current Updater.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Sources and Variability of Nitrate on an Alaskan Hillslope Dominated by Alder Shrubs, Kougarok, Alaska, 2017 and 2018

Data provided include results of analyses of soil pore-water, soil moisture, and leaf litter samples collected at a Kougarok Hillslope site dominated by alder shrubs (KG_MM64) in the Seward Peninsula, Alaska during July and September 2017 and 2018. Samples were from surface soils in close proximity to 5 alder patches, collected upslope, within, and downslope of the alder patches. Pore water was analyzed for a comprehensive set of anions, cations, elemental analyses, and oxygen and nitrogen isotopes. Soil samples were collected for soil moisture determination. Leaf litter extracts were analyzed for carbon and nitrogen content and carbon and nitrogen isotopes. This dataset contains 3 *.csv files and 1 *.pdf file. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Phosphorus and cover crop management practices affect phosphorus speciation in soils and eroded sediments

Abstract Agricultural runoff often contains P in dissolved and sediment‐bound forms, decreasing surface water quality. No‐till and cover cropping conservation practices have been recommended for reducing erosion and nutrient loss from cropping systems. The overall aims of this study were to characterize and evaluate the effects of fertilizer (placement and source) and cover crop management on P speciation in surface runoff sediments and source soil. In 2014, a field‐scale experiment was established in a no‐till, corn (Zea maysL.)–soybean (Glycine maxL.) cropping system with two cover crop treatments (with and without a winter crop; winter wheat [Triticum aestivumL.], rapeseed [Brassica napusL.], hairy vetch [Vicia villosaRoth], winter triticale [×Triticosecale Wittm.], and cereal rye [Secale cerealeL.]) and three P fertilizer management treatments (no P, fall broadcast diammonium phosphate, and spring subsurface injected ammonium polyphosphate). Phosphorus fractionation in the source soil collected in the fall of 2019 and sediment samples collected throughout 2020 were analyzed using a modified sequential P extraction method to evaluate the cumulative effects of imposing the treatment factors over 5 years. The direct P speciation was done using X‐ray absorption near edge structure spectroscopy. The indirect P speciation (fractionation) results showed that the management practices affected the exchangeable, organic matter‐associated, and Fe‐bound P fractions in sediments and the exchangeable and residual fractions in source soil. Direct P speciation results showed a depletion of Fe‐associated P in soil and sediment from cover crop treatment, suggesting that Fe‐associated P species were affected by cover crops. Changes in soil and runoff sediment P speciation would change the proportions and forms of soluble and particulate P in runoff sediments and may influence P bioavailability in aquatic ecosystems. Developing P fertilizer and cropping system management options with an understanding of soil P transformations helps maintain environmental sustainability.

Environmental Sciences & Ecology↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 1

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford BY-108 and BY-110 waste storage tanks. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge tests were conducted over two days from February 23-25, 2018, using headspace vapors from Hanford tanks BY-108 and BY-110. Headspace vapors from the BY-108 tank were fed to the PAPR respirator cartridge test stand, while vapors from the BY-110 headspace were fed to the APR respirator cartridge test stand. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Two different cartridges were assessed on each tank. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed for vapors from BY-110 using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—also were assessed for vapors from BY-108 over the same two days using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 Volume 1

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in powered air-purifying respirators (PAPR) to determine the period of time that the cartridges would provide adequate performance for PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, from headspace vapors from Hanford tank SX-101 and from June 23-24, 2017, from Hanford tank SX-104. Headspace vapors were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota) were assessed on separate days. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Defining Lipidomic Responses to Coronavirus Infection

Highly pathogenic human coronavirus infection can cause a severe atypical, rapid onset pneumonia with a mortality rate of up to 10% for severe acute respiratory syndrome coronavirus 1 (SARS-CoV 1), 35% for Middle East respiratory syndrome coronavirus (MERS-CoV), or 1% for severe acute respiratory syndrome coronavirus 2 (SARS-CoV 2 causative agent of COVID 19). While medical countermeasures successfully controlled the worldwide SARS-CoV epidemic, the MERS-CoV epidemic is still ongoing and continues to be a concern for travelers in the Middle East and the multi-year SARS-CoV 2 pandemic underscore the importance of defining biomarkers that are diagnostic and/or predictive of severe disease outcomes for respiratory viruses. Systems biology approaches provide global snapshots of infection induced changes in host cells/tissues and provide extremely rich datasets for understanding host pathogen interactions. Metabolites, especially lipids, are critical for viral replication but less is understood about infection induced changes to lipids due to limits in lipid species detection and identification. To characterize how individual lipid species and proteins with lipid associated functions contribute to highly pathogenic human coronavirus replication and disease severity, existing datasets were probed to determine cell type specific lipid responses to MERS-CoV infection and verification studies were performed to determine if modification of the host lipid signature (by inhibiting enzymatic functions that produce specific lipid species) can perturb CoV replication in human lung cells. MERS-CoV infects human lung epithelial, endothelial and fibroblast cells. All three cell types were infected with MERS-CoV and samples collected to analyze lipids, proteins, metabolites, and transcripts from 12 to 48 hours post infection. Time matched mock-infected cells were collected in parallel for each cell type. Following sample and statistical analysis, functional enrichment and bioinformatic analysis was performed to identify differentially expressed lipids and proteins. Two lipid species were found to be significantly upregulated following MERS-CoV infection, ceramides, and triacylglycerol both of which are indicative of cells undergoing apoptotic cell death. In contrast, sphingomyelins (lipid molecules that can serve as a precursor for one pathway for ceramide synthesis) had significantly decreased expression in MERS-CoV infected cells. An inhibitor of acid sphingomyelinase (that converts sphingomyelin to ceramides and phosphorylcholine) reduced MERS-CoV replication suggesting that production of ceramides is key for successful viral replication and transmission. Acyl-CoA-synthetase 3 (ACSL3), the only protein whose function is lipid associated and had increased differential expression in our dataset, regulates the synthesis of triacylglycerol (increased expression). Inhibitors that directly block ACSL3 (Triacsin C) but not steps later in the triacylglycerol synthesis pathway (Etomoxir) inhibit MERS-CoV replication suggesting that triacylglycerol production and/or ACSL3 activity is also key for viral replication. ACSL3 expression is also upregulated in lung cancer cells and is predicted to promote continued cell viability which would also enhance viral replication. The differentially expressed lipid and lipid-associated protein species identified in our studies suggest that MERS-CoV infection is activating cellular death pathways to limit the number of cells that become infected but also stimulating the production of lipid-associated enzymes that can prolong host cell viability and the amount of time progeny virions can be produced and released. As the inhibitors that worked against MERS-CoV infection were also efficacious against SARS-CoV 2 infection, countermeasures that target these host pathways may provide novel ways to block highly pathogenic human coronavirus infection and/or prevent severe disease outcomes.

59 BASIC BIOLOGICAL SCIENCES↗

SPRUCE 13C-Phospholipid Fatty Acid (13C-PLFA) Abundances, June 2014-June 2015

This data set provides the results of 13C phospholipid fatty acid analysis (13C-PLFA) of peat samples collected from ambient and experimental plots in the SPRUCE experiment site. The samples used to generate this data set were collected just prior to initiation of deep peat heating (DPH; 03 June 2014), after 3 months (09 September 2014), and after 10 months (16 June 2015). This data set includes the abundances and delta-13C isotopic signatures of individual lipids and of groups of lipids indicating total biomass, fungi, Gram-positive bacteria, Gram-negative bacteria, actinomycetes, and anaerobic bacteria. This dataset contains two files in comma separate (*.csv) format. Cores extending to 250 cm (200 cm in June 2015) were collected and subsampled at 10 cm intervals from 0 and 100 cm and 25 cm intervals below 100 cm depth. During the lipid extraction procedure, samples were pooled into the following depth increments in order to obtain sufficient material to achieve adequate lipid yield: 0-20, 20-50, 50-100, 100-150, 150-200, and 200-250cm.

actinomycetes↗

COMBLE-ISLAS water isotopes in precipitation (COMBLEISLASISO)

During the measurement period, precipitation was sampled on daily to sub-daily basis with a sampling kit consiting of a clear plastic box (60x40x40 cm) mounted to a ground structure. Daily sampling lasted from 22 Feb to 24 Mar 2020. At a fixed time of day (10 UTC), samples were collected and the sampling box cleaned for the next sample. Additionally, during intense observations periods (IOPs) announced by ISLAS, ARMS scientists increased sampling frequency to sub-daily sampling. During the campaign period, 2 IOPs were conducted, with in total 12 samples taken. IOP1 lasted from 27 Feb 10 to 02 Mar 2020, and IOP2 lasted from 12 Mar to 14 Mar 2020. Solid precipitation in the box was then melted, transferred to an 8 ml glass vial, sealed and shipped to FARLAB (University of Bergen, Norway) for stable water isotope analysis. Measured stable isotope composition of precipitation samples will be related to conditions at other sampling locations, and at the evaporation site to inform about conservation of water isotope quantities. In the period from 22 Feb to 24 Mar, 23 daily samples were collected at 10 UTC for stable water isotope analysis. During the entire sampling period, a high variability of precipitation phase was encountered. Most samples were recovered in the form of graupel/snow (12 samples), as rain (7 samples), and the remaining samples fell as graupel, snow, rain or frozen rain. Precipitation amounts varied between <1 mm (26 Feb) and 140 mm (25 Feb) within the sampling box. Furthermore, higher-resolution sampling was conducted during 2 intense observation periods (IOPs). During IOP1, lasting from 27 Feb 10 UTC to 02 Mar 10 UTC, 7 samples were collected, all of them as solid phase precipitation. IOP2 lasted from 12 Mar 10 UTC to 14 Mar 09 UTC, and 5 samples (all as graupel/snow) were collected. Samples were processed according to FARLAB standard measurement procedures. In short, samples were transferred to 1.5 ml glass vials with rubber/PTFE septa (part #548-0907, VWR, USA). An autosampler (A0325, Picarro Inc) transferred ca. 2&micro;l per injection into a high-precision vapourizer (A0211, Picarro Inc, USA) heated to 110&deg;C. After blending with dry N2 (< 5 ppm H2O) the gas mixture was directed into the measurement cavity of a Cavity-Ring Down Spectrometer (L2140-i, Picarro Inc) for about 7 min with a typical water concentration of 20 000 ppm. Memory effects were reduced by two times measuring a vapour mixture at a mixing ratio of 50 000 ppm, obtained from 2 injections of 2 &micro;l for 5 min at the beginning of each new sample vial. Thereafter, another 6 injections of 2 &micro;l per sample were measured individually as described above, and averages of the last 5 injections were used for further processing. Three standards were measured at the beginning and end of each batch, including a drift standard DI2 (&delta;D: -50.72&plusmn;0.73 permil, &delta;18O: -7.63&plusmn;0.10 permil), and for calibration the laboratory standards GLW (&delta;D: -307.79&plusmn;0.75 permil, &delta;18O: -40.02&plusmn;0.07 permil) and EVAP2 (&delta;D: 9.52&plusmn;0.65 permil, &delta;18O: 1.81&plusmn;0.13 permil). A detailed calibration report is included with the final uploaded data set.

54 ENVIRONMENTAL SCIENCES↗

Data Report: Pore Water Geochemistry at Green Canyon 955, deepwater Gulf of Mexico

Two holes were drilled in Green Canyon Block 955 (GC 955) in the deepwater Gulf of Mexico: Hole GC 955 H002 (H002) and Hole GC 955 H005 (H005). Here we present the solute concentrations and oxygen and hydrogen isotope ratios of pore water extracted from sediment whole-round samples collected from these holes. The analytical methods, degree of sample contamination, and the method for contamination correction are discussed as are the general trends in the geochemical data.

03 NATURAL GAS↗

Stable Isotope and Geochemical Evidence for Hydrological Isolation in an Arctic Coastal Plain Landscape, Barrow, Alaska, 2013

Data include results from water chemistry and water isotope analyses for samples collected in Barrow, Alaska during July and September 2013. Samples were from surface and soil pore waters from 15 locations: 3 locations from interlake polygonal terrain, 6 locations associated with interlake drainages, and 6 locations within or at the outlets of different aged drained thaw lake basins (DTLBs). Samples were taken in different drainage flow types at three different depths at each location in and around the Barrow Environmental Observatory. This dataset includes one .csv data file and one .pdf user guide.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Geophysical Characterization and Monitoring of the 200 Area Treated Effluent Disposal Facility to Support Permit Renewal; TEDF Geophysical Monitoring

The Treated Effluent Disposal Facility (TEDF), located in the 200 East Area of the Hanford Site, is a site where non-hazardous and non-radioactive liquid wastes are disposed into two state-permitted infiltration basins. In 2016, the Washington State Department of Ecology denied a permit renewal request for TEDF due to the inability to adequately assess the impact of TEDF discharge water on the underlying groundwater quality. TEDF overlies the relatively impermeable Ringold Lower Mud (RLM) unit, whose upper contact lies in the vadose zone approximately 30 m below ground surface and approximately 10 m above the water table boundary. The RLM is assumed to isolate TEDF discharge water from the natural groundwater aquifer, which is monitored using wellbores screened below the RLM. Therefore, samples collected from monitoring wells near TEDF are not considered representative of TEDF discharge water. Rather, TEDF discharge water is assumed to mound on top of the RLM to form a perched aquifer. To support permitting of the TEDF, a new monitoring well is required that can be used to sample water from the presumed perched water aquifer above the RLM. Ideally, the screened section of the well would be located at the peak of the perched water mound(s), which presumably occurs at the point of maximum vertical flux from TEDF to the RLM, or equivalently where the dominant infiltration flow paths reach the RLM. This report describes how time-lapse 3D electrical resistivity tomography (ERT) was used in conjunction with nominal TEDF discharge operations to image the dominant flow paths from each pond to the RLM. Results are summarized in Figure ES.1. Figure ES.1A shows a satellite image of the TEDF overlain by an array of surface ERT electrodes. The solid and dashed black circles denote the zones of maximum vertical flux at the RLM within the south and north ponds, respectively, and presumably the regions where perched water peaks during discharge. Figure ES.1B shows time-lapse difference imaging results approximately 15 days after switching discharge from the south pond to the north pond. Blue iso-surfaces beneath the north pond denote regions of increasing bulk electrical conductivity caused by increasing saturation due to infiltrating water. Red iso-surfaces beneath the south pond denote regions that were previously saturated during the south pond discharge and are now de-saturating, causing a decrease in bulk electrical conductivity. In both cases, the zones of maximum change mark the dominant flow paths to the RLM. Figure ES.1C shows time-lapse imaging results approximately 15 days after switching discharge from the north pond to the south pond. In this case, blue iso-surfaces mark the dominant flow paths to the RLM from the south pond. The red iso-surfaces mark the dominant flow paths that existed during discharge to the north pond. The regions of maximum change in bulk conductivity (due to saturation or desaturation) that mark the primary flow paths are equivalent in both cases and denoted by the dashed solid and black circles. If a perched water zone forms on the RLM, it is likely to mound within or near the dashed circle during discharge to the north pond, and in the solid circle during discharge to the south pond. In other words, if perched water mounding occurs, the circles mark the optimum locations suggested by the ERT imaging for monitoring boreholes to be placed, enabling samples to be collected that are representative of TEDF discharge impacts on groundwater quality.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monthly Sewer Monitoring Report for LLNL Livermore Site, April 2020

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyzes these compliance samples, and results (Tables 1–3) are used to establish LLNL compliance with the 2019–2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported (Table 4) for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L). The results are presented in Table 5. In addition to the sampling noted above, the SMS continuously monitors LLNL sewage effluent in real-time for flow rate, pH, metals, and radioactivity. Standard measurement methods are used to monitor flow and pH to determine permit compliance. Unique nonstandard analytical methods monitor for the presence of metals and radioactivity using x-ray fluorescence (XRF) and gamma spectroscopy, respectively. If an anomalous condition is detected by the monitoring system, an alarm activates LLNL’s Sewer Diversion Facility (SDF) and Livermore Water Reclamation Plant (LWRP) operators are notified that a potential release has occurred.

54 ENVIRONMENTAL SCIENCES↗