Search NASASearch

SEARCH · Search NASA

Results for “sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Uniform sampling analysis of a hybrid phase-locked loop with a sample-and-hold phase detector

Phase-locked-loop (PLL) bit synchronizers often employ integrate-and-dump type phase detectors that provide phase error information only at discrete points in time. Usually these phase detectors are followed by sample-and-hold circuits to produce a stairstep error voltage as the input to a standard analog circuit loop filter. When the loop is configured in this manner, it is referred to as a hybrid PLL. Sampled-data analysis methods (Z transforms) are used to determine the stability and transient response of this loop.

Barab, S.

Sample size and sampling errors as the source of dispersion in chemical analyses

The paper describes a Monte Carlo model for simulation of two-dimensional representations of thin sections of some of the more common igneous rock textures. These representations are extrapolated to three dimensions to develop a volume of 'rock'. The model (here applied to a medium-grained high-Ti basalt) can be used to determine a statistically significant sample for a lunar rock or to predict the probable errors in the oxide contents that can occur during the analysis of a sample that is not representative of the parent rock.

Clanton, U. S.

Krypton and xenon in Apollo 14 samples - Fission and neutron capture effects in gas-rich samples

Gas-rich Apollo 14 breccias and trench soil are examined for fission xenon from the decay of the extinct isotopes Pu-244 and I-129, and some samples have been found to have an excess fission component which apparently was incorporated after decay elsewhere and was not produced by in situ decay. Two samples have excess Xe-129 resulting from the decay of I-129. The excess is correlated at low temperatures with excess Xe-128 resulting from neutron capture on I-127. This neutron capture effect is accompanied by related low-temperature excesses of Kr-80 and Kr-82 from neutron capture on the bromine isotopes. Surface correlated concentrations of iodine and bromine are calculated from the neutron capture excesses.

Drozd, R.

A Mars sample return mission using a rover for sample acquisition

Mission and vehicle concepts are discussed for obtaining surface and subsurface samples of Mars, acquired by a roving vehicle, and returning those samples to earth for detailed analyses in scientific laboratories. Mission options that were traded off in order to arrive at a baseline mission considered most worthy of further study comprised the following: (1) direct entry vs entry out of Mars orbit; (2) direct return from the Mars surface vs rendezvous in Mars orbit and return to earth from there; and (3) propulsive orbit injection and aeroballistic entry (similar to Viking) vs aerocapture into Mars orbit and aeromaneuvering entry. After a comparison of relative merits - based primarily on mass and cost estimates and secondarily on configurational constraints - a baseline mission was selected: out-of-orbit entry, return after Mars orbit rendezvous, and aerocapture/aeromaneuvering. Trajectory design is based on the 1996 launch opportunity. Launch mass requirements for eight mission options, a mission and vehicle description for the baseline mission, and the outline of a mission sequence of events are presented.

De Vries, J. P.

Analyses at High Spatial Resolution of Organic Molecules in Extraterrestrial Samples: Two-Step Laser Mass Spectrometry: Search for Polycyclic Aromatic Hydrocarbons in Antarctic Meteorite and Micrometeorite Samples

Perhaps the best way to summarize the past three-year grant period is to cite the publications and present a brief synopsis of each: 1. "Indigenous Polycyclic Aromatic Hydrocarbon Molecules in Circumstellar Graphite Grains." Bulk C-12/C-13 isotope ratios observed in some graphite grains extracted from primitive meteorites point strongly to a circumstellar origin. By applying our technique of microprobe two-step laser desorption laser ionization mass spectrometry ((mu)L(sup 2)MS) to individual circumstellar graphite grains we have measured the C-12/C-13 isotope ratio of various polycyclic aromatic hydrocarbons (PAHS) found in these grains. 2. "Deuterium Enrichments in Cluster IDPS," Large enrichments in the D/H isotope ratios in IDPs likely arise from the preservation of presolar molecules. 3. "Evidence for thermalization of surface-disorder molecules at heating rates of 10(exp 8) K/s". A careful study of the ((mu)L(sup 2)MS) of aniline-d(sub 7) from a single-crystal surface (0001) of sapphire (al2O3) shows that all measured properties are consistent with a thermal mechanism for desorption. 4. "Search for past life on Mars; possible relic biogenic activity in Martian meteorite ALH 84001. The authors examined the Martian meteorite ALH 84001 and found several lines of evidence compatible with existence of past primitive (single-cell) life on early Mars. 5. "Microprobe two-step laser mass spectrometry as an analytical tool for meteorite samples". THis paper presents a comprehensive review of (mu)L(sup 2)MS and how this technique can be applied to meteoritic samples. 6. "Indigenous polycyclic aromatic hydrocarbons in circumstellar graphite grains from primitive meteorites". The C-12/C-13 isotope ratios were measured for PAHs in a total of 89 spherical graphite grains. 7. "Observation of indigenous polycyclic aromatic hydrocarbons in "Giant" carbonaceous antarctic micrometeorites." The (mu)L(sup 2)MS method was used to establish the nature and distribution of PAHs in fragments of fifteen (approx. 200 microns) carbonaceous antarctic micrometeorites (AMMs). 8. "Evidence for the extraterrestrial origin of polycyclic aromatic hydrocarbons in the Martian meteorite ALH 84001" We have undertaken additional contamination studies of ALH 84001.

Zare, Richard N.

Lunar Sample Quarantine & Sample Curation

The main goal of this presentation is to discuss some of the responsibility of the lunar sample quarantine project. The responsibilities are: flying the mission safely, and on schedule, protect the Earth from biohazard, and preserve scientific integrity of samples.

Allton, Judith H.

Preliminary Sample Analysis Plan for the Cometary and Interstellar Samples Being Returned by the Stardust Spacecraft

The NASA Stardust comet sample return mission is proceeding very well, and the science team breathed a collective sigh of relief following the successful comet sample collection phase which occurred during a 6.1 km/s, 340km-close flyby of comet Wild-2 on Jan 2 of this year. Multiple images of the comet nucleus were obtained and a variety of onboard instruments returned in situ data on the spatial distribution, particle size frequency and composition of the dust in the comet s coma. These data are currently being processed and analyzed. It is expected that 500-1000 comet particles >15 m were collected by impact into low density silica aerogel, as well as many more smaller grains. Previous tests with hypervelocity guns firing small particles into aerogel indicate that material should have successfully been collected by the Stardust aerogel [1&2]. In addition, many (~100) grains of interstellar material newly entering the Solar System should have been collected by the spacecraft during its cruise phase to the comet.

Zolensky, M.

Stardust Curation at Johnson Space Center: Photo Documentation and Sample Processing of Submicron Dust Samples from Comet Wild 2 for Meteoritics Science Community

Dust particles released from comet 81P/Wild-2 were captured in silica aerogel on-board the STARDUST spacecraft and successfully returned to the Earth on January 15, 2006. STARDUST recovered thousands of particles ranging in size from 1 to 100 micrometers. The analysis of these samples is complicated by the small total mass collected ( < 1mg), its entrainment in the aerogel collection medium, and the fact that the cometary dust is comprised of submicrometer minerals and carbonaceous material. During the six month Preliminary Examination period, 75 tracks were extracted from the aerogel cells , but only 25 cometary residues were comprehensively studied by an international consortium of 180 scientists who investigated their mineralogy/petrology, organic/inorganic chemistry, optical properties and isotopic compositions. These detailed studies were made possible by sophisticated sample preparation methods developed for the STARDUST mission and by recent major advances in the sensitivity and spatial resolution of analytical instruments.

Nakamura-Messenger, K.

Sample Handling Considerations for a Europa Sample Return Mission: An Overview

The intent of this abstract is to provide a basic overview of mission requirements for a generic Europan plume sample return mission, based on NASA Curation experience in NASA sample return missions ranging from Apollo to OSIRIS-REx. This should be useful for mission conception and early stage planning. We will break the mission down into Outbound and Return legs and discuss them separately.

Fries, M. D.

Cleaning Genesis Sample Return Canister for Flight: Lessons for Planetary Sample Return

Sample return missions require chemical contamination to be minimized and potential sources of contamination to be documented and preserved for future use. Genesis focused on and successfully accomplished the following: - Early involvement provided input to mission design: a) cleanable materials and cleanable design; b) mission operation parameters to minimize contamination during flight. - Established contamination control authority at a high level and developed knowledge and respect for contamination control across all institutions at the working level. - Provided state-of-the-art spacecraft assembly cleanroom facilities for science canister assembly and function testing. Both particulate and airborne molecular contamination was minimized. - Using ultrapure water, cleaned spacecraft components to a very high level. Stainless steel components were cleaned to carbon monolayer levels (10 (sup 15) carbon atoms per square centimeter). - Established long-term curation facility Lessons learned and areas for improvement, include: - Bare aluminum is not a cleanable surface and should not be used for components requiring extreme levels of cleanliness. The problem is formation of oxides during rigorous cleaning. - Representative coupons of relevant spacecraft components (cut from the same block at the same time with identical surface finish and cleaning history) should be acquired, documented and preserved. Genesis experience suggests that creation of these coupons would be facilitated by specification on the engineering component drawings. - Component handling history is critical for interpretation of analytical results on returned samples. This set of relevant documents is not the same as typical documentation for one-way missions and does include data from several institutions, which need to be unified. Dedicated resources need to be provided for acquiring and archiving appropriate documents in one location with easy access for decades. - Dedicated, knowledgeable contamination control oversight should be provided at sites of fabrication and integration. Numerous excellent Genesis chemists and analytical facilities participated in the contamination oversight; however, additional oversight at fabrication sites would have been helpful.

Allton, J. H.

An MBSE-based Approach to Architecting a Robotic Sample Capture System Concept for Potential Mars Sample Return

A model-based systems engineering (MBSE) approach was applied to architecting an orbiting sample Capture and Orient Module (COM) system concept for a Capture, Contain, and Return System (CCRS) payload concept for the notional Mars Sample Return (MSR) campaign at the NASA Jet Propulsion Laboratory. An architecture framework was established, covering multiple organizational layers of the system, along with structural, behavioral, data, and requirements perspectives. A workflow process to implement the architecting activities within the COM engineering team was established. The approach helped maintain consistency in terminology, helped ensure alignment of structural, behavioral, data, and requirements elements within each organization layer, and guided the engineering team through an architecting process that helped develop the architecture for a Capture and Orient Module system concept.

Younse, Paulo

Quasiclassical sampling and Wigner sampling of initial vibrational coordinates and momenta for polyatomic molecules in Monte Carlo molecular dynamics simulations

In a quasiclassical trajectory simulation, the vibrational modes are initialised with quantised vibrational energies, but vibrational phases are sampled by Monte Carlo. This requires an algorithm to assign coordinates and momenta to the various atoms. In this work, we present two methods for implementing this for nonrotating polyatomic molecules, namely, fixed-energy vibrational-state-selected initial conditions and thermal initial conditions. We also present a method for initiating classical trajectories with a ground-state Wigner distribution. These vibrational treatments are sufficient to initialise trajectories for unimolecular processes, and we also show how they can be applied to simulate bimolecular collision processes. The treatments of unimolecular and bimolecular collision processes are available in two Python codes called wigner_state_selected.py and bimolecular_collision.py, respectively, which will generate initial condition files that are recognisable by the SHARC and SHARC-MN computer programs for dynamics calculations. Both codes are available as standalone programs, as well as being included in SHARC-MN, and they will be included in future versions of SHARC. Here, the methods implemented in these codes are mostly also available in the ANT computer program, and those that are not available in ANT will be incorporated in future versions of ANT.

Wigner distribution

LLNL measurements of thermally irradiated HEU sample and saltwater-matrixed HEU sample

Two scintillation vials, kindly provided by the PNNL team, were received in the LLNL radiochemistry building on June 10, 2024; one containing approximately 2 mL dissolved thermally-irradiated HEU, and the other containing dried salt from irradiated seawater. A quick, semiquantitative screening count of the salt showed that the activation product activities were very low, with the highest activity being ~1 Bq 24 Na. The dissolved HEU solution was transferred to a Prindle vial (LLNL standard counting geometry) and weighed. Approximately 2 mL 3 M HNO 3 was added so that the solution completely covered the bottom of the vial and Gamanal software would be able to accurately generate an efficiency curve. This sample, called “PNNLFP24” is the irradiated HEU solution received, gravimetrically diluted by a factor of 1.7356 ± 0.0003, and was sent for quick gamma counting prior to further modification. Meanwhile the salt was quantitatively transferred to a 250 mL polyethylene bottle and dissolved in 160 mL 3 M HNO 3 . After counting, 50 µL PNNLFP24 was aliquoted for Resonance Ionization Mass Spectrometry (RIMS) analysis, and then 10.0 mL of the salt solution (6.03% of the total salt, gravimetrically) was added to the remaining PNNLFP24 solution to make “PNNLFPSW24”. After weighing, two 100 µL aliquots were removed for RIMS and DES, and 3 mL was aliquoted for microfluidic chemistry. The remaining “PNNLFPSW24” solution was weighed and proceeded for singles and coincidence counting on the MCBOS system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH