At least 127 records · Page 7

Gimbaled-mirror scanning system capable of spiral pattern

Gimbaled-mirror infrared radiation scanner, with a lightweight torque motor direct coupled to each axis, is capable of scanning in a highly efficient spiral pattern. The scanner is lightweight and can be remotely positioned in previously inaccessible areas because the radiometer head and the gimbaled-mirror scanner can be separated.

Haertsch, O. C.↗

Variable voltage electron microscopy: Toward atom-by-atom fabrication in 2D materials

The precisely focused electron beam (e-beam) in scanning transmission electron microscopy has been found to be a versatile tool for patterning matter on the atomic level and enabling atom-by-atom fabrication, however, beam-induced phenomena are known to be extremely sensitive to the e-beam energy and are closely correlated with the proximity of the knock-on threshold. Here we provide a method to control the energy transferred to the sample while facilitating much faster changes in accelerating voltages by maintaining a nearly constant temperature in the electron microscope lenses. We use this method to demonstrate in-situ nano-milling of a graphene film followed rapidly by “gentler” imaging at lower energy. Additionally, the insertion and controlled movement of silicon dopants in graphene is demonstrated by employing a different e-beam energy during each process. We believe the incorporation of variable e-beam energy will broaden the potential for atomic scale e-beam fabrication.

36 MATERIALS SCIENCE↗

A system for simulating aerial or orbital TV observations of geographic patterns

A system which simulates observation of the earth surface by aerial or orbiting television devices has been developed. By projecting color slides of photographs taken by aircraft and orbiting sensors upon a rear screen system, and altering scale of projected image, screen position, or TV camera position, it is possible to simulate alternatives of altitude, or optical systems. By altering scan line patterns in COHU 3200 series camera from 525 to 945 scan lines, it is possible to study implications of scan line resolution upon the detection and analysis of geographic patterns observed by orbiting TV systems.

Latham, J. P.↗

Vibration Pattern Imager (VPI): A control and data acquisition system for scanning laser vibrometers

The Vibration Pattern Imager (VPI) system was designed to control and acquire data from scanning laser vibrometer sensors. The PC computer based system uses a digital signal processing (DSP) board and an analog I/O board to control the sensor and to process the data. The VPI system was originally developed for use with the Ometron VPI Sensor, but can be readily adapted to any commercially available sensor which provides an analog output signal and requires analog inputs for control of mirror positioning. The sensor itself is not part of the VPI system. A graphical interface program, which runs on a PC under the MS-DOS operating system, functions in an interactive mode and communicates with the DSP and I/O boards in a user-friendly fashion through the aid of pop-up menus. Two types of data may be acquired with the VPI system: single point or 'full field.' In the single point mode, time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and is stored by the PC. The position of the measuring point (adjusted by mirrors in the sensor) is controlled via a mouse input. The mouse input is translated to output voltages by the D/A converter on the I/O board to control the mirror servos. In the 'full field' mode, the measurement point is moved over a user-selectable rectangular area. The time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and converted to a root-mean-square (rms) value by the DSP board. The rms 'full field' velocity distribution is then uploaded for display and storage on the PC.

Rizzi, Stephen A.↗

The Seasat scanning multichannel microwave radiometer /SMMR/: Antenna pattern corrections - Development and implementation

The antenna temperatures measured by the Seasat scanning multichannel microwave radiometer (SMMR) differ from the true brightness temperatures of the observed scene due to antenna pattern effects, principally from antenna sidelobe contributions and cross-polarization coupling. To provide accurate brightness temperatures convenient for geophysical parameter retrievals the antenna temperatures are processed through a series of stages, collectively known as the antenna pattern correction (APC) algorithm. A description of the development and implementation of the APC algorithm is given, along with an error analysis of the resulting brightness temperatures.

Njoku, E. G.↗

Microbial Community Characteristics Largely Unaffected by X-Ray Computed Tomography of Sediment Cores

X-ray computed tomography (CT) scanning is used to study the physical characteristics of soil and sediment cores, allowing scientists to analyze stratigraphy without destroying core integrity. Microbiologists often work with geologists to understand the microbial properties in such cores; however, we do not know whether CT scanning alters microbial DNA such that DNA sequencing, a common method of community characterization, changes as a result of X-ray exposure. Our objective was to determine whether CT scanning affects the estimates of the composition of microbial communities that exist in cores. Sediment cores were extracted from a salt marsh and then submitted for CT scanning. We observed a minimal effect of CT scanning on microbial community composition in the sediment cores either when the cores were examined shortly after recovery from the field or after the cores had been stored for several weeks. In contrast, properties such as sediment layer and marsh location did affect microbial community structure. While we observed that CT scanning did not alter microbial community composition as a whole, we identified a few amplicon sequence variants (13 out of 7,037) that showed differential abundance patterns between scanned and unscanned samples among paired sample sets. Our overall conclusion is that the CT-scanning conditions typically used to obtain images for geological core characterization do not significantly alter microbial community structure. We stress that minimizing core exposure to X-rays is important if cores are to be studied for biological properties. Future investigations might consider variables, such as the length and energy of radiation exposure, the volume of the core, or the degree, to which microbial communities are stressed as important factors in assessing the impact of X-rays on microbes in geological cores.

59 BASIC BIOLOGICAL SCIENCES↗

High Thermoelectric Performance in 2D Sb 2 Te 3 and Bi 2 Te 3 Nanoplate Composites Enabled by Energy Carrier Filtering and Low Thermal Conductivity

Thermoelectrics are an important class of materials with great potential in alternative energy applications. In this study, two-dimensional (2D) nanoplates of the layered chalcogenides, Sb 2 Te 3 and Bi 2 Te 3 , are synthesized and composites of the two are investigated for their thermoelectric properties. The two materials, Sb 2 Te 3 and Bi 2 Te 3 , were synthesized as hexagonal, 2D nanoplates via a colloidal polyol route. The as-synthesized Sb 2 Te 3 and Bi 2 Te 3 vary drastically from one another in their lateral and vertical dimensions as revealed by scanning electron microscopy and atomic force microscopy. The single crystalline nanoplate nature is deduced by high-resolution transmission electron microscopy and selected area electron diffraction. Nanoplates have well-defined hexagonal facets as seen in the scanning and transmission electron microscopy images. The nanoplates were consolidated as an anisotropic nanostructured pellet via spark plasma sintering. Preferred orientation observed in the powder X-ray diffraction pattern and scanning electron microscopy images of the fractured pellets confirm the anisotropic structure of the nanoplates. Thermoelectric properties in the parallel and perpendicular directions were measured, revealing strong anisotropy with a significant reduction to thermal conductivity in the perpendicular direction due to increased phonon scattering at nanoplate interfaces. All compositions, except that of the 25% Bi 2 Te 3 nanoplate composite, behave as degenerate semiconductors with increasing electrical resistivity as the temperature increases. The Seebeck coefficient is also increased dramatically in the nanocomposites, the highest reaching 210 μV/K for 15% Bi 2 Te 3 . The increase in Seebeck is attributed to energy carrier filtering at the nanoplate interfaces. Overall, these enhanced thermoelectric properties lead to a drastic increase in the thermoelectric performance in the perpendicular direction, with zT ~ 1.26, for the 15% Bi 2 Te 3 nanoplate composite at 450 K.

36 MATERIALS SCIENCE↗

Time-Resolved Measurements Of Laser Far-Field Patterns

Computer-controlled scanning photometric instrumentation system measures intensity pattern in far field of pulsed laser as function of time during each pulse (provided that pulse is at least 1 ns long). Such measurements important in studying dynamics of laser operation: they reveal such previously unobservable phenomena as oscillations of undesired spatial modes of radiation pattern during pulse, steering of beam during pulse, and instability of intensity of laser beam. Principal advantages of system are its relatively low cost and its ability to function under normal lighting conditions without incurring damage.

Forrest, Kathrine↗

Electronic recording of holograms with applications to holographic displays

The paper describes an electronic heterodyne recording which uses electrooptic modulation to introduce a sinusoidal phase shift between the object and reference wave. The resulting temporally modulated holographic interference pattern is scanned by a commercial image dissector camera, and the rejection of the self-interference terms is accomplished by heterodyne detection at the camera output. The electrical signal representing this processed hologram can then be used to modify the properties of a liquid crystal light valve or a similar device. Such display devices transform the displayed interference pattern into a phase modulated wave front rendering a three-dimensional image.

Claspy, P. C.↗

Measuring residual stress in Ti-6Al-4V with HR-EBSD, using reference patterns from annealed material

In this study, elastic strain and residual stress values in an engineering material were determined by high-resolution EBSD (HR-EBSD) using reference patterns from annealed, recrystallized material. Specifically, rolled Ti-6Al-4V sheet was analyzed using HR EBSD in both an as-annealed and a strained state, the latter established via a static two-point bend fixture. The commercial software CrossCourt4 (CC4) was used to evaluate the relative intragranular strain tensor components of the alpha grains mapped by HR-EBSD. The intragranular reference patterns identified in each grain by the software were then replaced with similarly-oriented patterns from scans of the as-annealed, recrystallized material. The CC4 analysis was then repeated to provide calibrated strain and residual stress values. Elastic strains on the order of 10–3 were detected, with corresponding residual stress values on the order of 1 GPa. Subsequent analyses using high energy synchrotron x-ray diffraction showed good correlation with the elastic strains measured by HR-EBSD using the annealed reference patterns. Additionally, the maximum macroscopic stress analytically predicted for two-point bending was in agreement with the residual stress observed. Good repeatability of the methodology and insight into the state of individual grains were also observed. The findings provide encouraging evidence that accurate intragranular and long-range residual stress measurements of engineering significance can be made with HR-EBSD using a physical reference pattern library.

36 MATERIALS SCIENCE↗

Multibeam Antenna Design and Development for NASA Advanced Communications Technology Satellite (ACTS)

The design of the ACTS multibeam antenna is described, and its performance is evaluated. The multibeam antenna is designed to cover the continential U.S. and provides three fixed spot beams for high burst rate operations and two scanning beams for low burst rate operations. The antenna has one main reflector, a dual polarized subreflector, and two orthogonal feed assemblies. The feed system is to receive a linearly polarized communication signal from 28.9-30.0 GHz and to provide the elevation and azimuth error tracking signals at 29.975 GHz with a 0.01 deg tracking accuracy. The feed system uses a single multiflare conical horn and a multimode coupler to provide a symmetric primary pattern for the communication signal. The sidelobe characteristics of the reflector, and the relation between the sidelobe level and surface distortion are studied. It is noted that the performance measurements for the multibeam antenna correlate well with predictions for secondary patterns and scan characteristics.

Choung, Youn H.↗

Synthesis strategies toward improved ordering of [MnO 6 ] octahedra in tunnel structured 2 × 3 and 2 × 4 MnO 2

Improved homogeneity of tunnel size in Na-stabilized 2 × 3 and 2 × 4 MnO 2 structures was achieved by identifying and controlling critical synthesis parameters. 2 × 3 and 2 × 4 MnO 2 tunnel manganese oxide nanowires were obtained by hydrothermal treatment of Na-birnessite, a layered manganese oxide that undergoes a layer-to-tunnel transition under high pressure and temperature. Herein, the improved ordering of [MnO 6 ] octahedra is revealed via a combined analysis of X-ray diffraction patterns and scanning transmission electron microscopy images. Furthermore, we show that crystallinity of the Na-birnessite precursor and the chemical composition of the system during hydrothermal treatment are crucial for achieving the targeted size of the structural tunnels with adequate uniformity.

36 MATERIALS SCIENCE↗

Effects of Ionizing Radiation on the Thermodynamic Stability of Boehmite and Gibbsite

Here, in this study, we examined the effect of gamma radiation on the stabilities of aluminum hydroxide (gibbsite) and aluminum oxyhydroxide (boehmite) nanoparticles in relation to their thermal decomposition. X-ray diffraction (XRD) patterns and scanning electron microscopy (SEM) images revealed no significant differences in mineral components or morphology before and after radiation. However, thermogravimetric and differential scanning calorimetry (TGA/DSC) analyses showed that both boehmite and gibbsite nanoparticles experienced decreased mass loss following irradiation. Raman and attenuated total reflection-Fourier transfer infrared (ATR-FTIR) spectra indicated that a fraction of the hydroxyl content in both cases was selectively cleaved by radiation, primarily at the particle surfaces. Quantitative analyses of thermal mass loss behavior demonstrated that irradiated boehmite and gibbsite nanoparticles had higher activation energies than their pristine counterparts, with the extent of the increase dependent on the total dose. Taken together, these findings suggest that exposure to a sufficient dose of ionizing radiation alters these materials such that they are less prone to decomposition by dehydration. This increased stability may be due to the decreased hydrous nature of the samples after radiation exposure, which was supported by further high temperature drop calorimetry. Additionally, a radiation-induced amorphous phase on the nanoparticle surfaces appears to have a permanent and positive influence on their thermodynamic stabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Iterative Learning Control for High-Speed Rosette Trajectory Tracking

We demonstrate high-speed tracking of a selfrepeating non-raster scan AFM pattern known as rosette. To generate this pattern, the lateral axes of the scanner trace a sum of two sinusoids with different frequencies but identical amplitudes. A feedback controller is combined with an iterative learning controller (ILC) to track this repetitive pattern. The feedback controller is designed based on the internal model principle and incorporates the fundamental reference frequencies. The ILC eliminates the repeating deterministic disturbances that appear in the tracking error. To verify the efficacy of the control approach, an experiment is conducted using a two degrees-of-freedom microelectromechanical system nanopositioner to track a rosette pattern sequentially at the rate= of five frames per second. The experimental results show that the root-mean-square value of tracking error has been reduced by more than 50% owing to the ILC

42 ENGINEERING↗

Lamb wave imaging with actuator network for damage quantification in aluminum plate structures

Lamb waves have been widely used for damage detection on plate-like structures. However, there are still considerable interests on quantifying damage with complex profile. In this article, quantification of complex damage in plate-like structures using a network of actuators and time-space Lamb wavefield is investigated. The actuator network inspection system is implemented with multiple PZT transducers for Lamb wave actuation in round robin pattern and scanning laser Doppler vibrometer for wavefield sensing. The PZT network is arranged in a way that the target area is fully enclosed and Lamb waves come to the damage from all directions. Waves induced by the damage are subsequently obtained through frequency-wavenumber filtering, using the experimentally acquired dispersion curves presented in the paper. The filtered waves from all wave actuators are then used to generate a synthetic image of the damage being inspected. Two cases of complex damage are evaluated on aluminum plates, mass loss with triangular profile and mass addition with a three-letter cluster profile. Our results show that the damages are not only detected but also their profiles are clearly outlined in the images. We believe the subject methods provide improved evaluation of damage profile for Lamb wavefield based damage quantification.

Materials Science↗

Antenna pattern correction procedures for the Scanning Multichannel Microwave Radiometer /SMMR/

Procedures for correcting antenna temperature measurements and retrieving the true brightness temperatures are developed for the Scanning Multichannel Microwave Radiometer (SMMR) flown on the Seasat-A and Nimbus-G satellites. These procedures are necessary to meet the measurement accuracies required for deriving sea surface temperatures and wind speeds. It is shown that sidelobe contributions and polarization cross-coupling are major effects to be accounted for, in addition to some unique features of the SMMR instrument such as integration times and antenna scan characteristics. Methods are presented for data averaging and data reformatting, these are to be used with geophysical parameter retrieval algorithms.