Search NASA⌕ Search

SEARCH · Search NASA

Results for “selective heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Cyclical biodirectional rotary actuator

Thermally powered device flips magnetometer between one of two positions located 180 deg apart and permits instrument calibration. Pair of heat-extensible springs selectively rotate shaft from one position to other when electric heaters bonded to them are energized.

Stange, W. C.↗

A solar thermal electric power plant for small communities

A solar power plant has been designed with a rating of 1000-kW electric and a 0.4 annual capacity factor. It was configured as a prototype for plants in the 1000 to 10,000-kWe size range for application to small communities or industrial users either grid-connected or isolated from a utility grid. A small central receiver was selected for solar energy collection after being compared with alternative distributed collectors. Further trade studies resulted in the selection of Hitec (heat transfer salt composed of 53 percent KNO3, 40 percent NaNO2, 7 percent NaNO3) as both the receiver coolant and the sensible heat thermal stroage medium and the steam Rankine cycle for power conversion. The plant is configured with road-transportable units to accommodate remote sites and minimize site assembly requirements. Results of the analyses indicate that busbar energy costs are competitive with diesel-electric plants in certain situations, e.g., off-grid, remote regions with high insolation. Sensitivity of energy costs to plant power rating and system capacity factor are given.

Holl, R. J.↗

Assessment of solar-assisted gas-fired heat pump systems

As a possible application for the Goldstone Energy Project, the performance of a 10 ton heat pump unit using a hybrid solar gas energy source was evaluated in an effort to optimize the solar collector size. The heat pump system is designed to provide all the cooling and/or heating requirements of a selected office building. The system performance is to be augmented in the heating mode by utilizing the waste heat from the power cycle. A simplified system analysis is described to assess and compute interrrelationships of the engine, heat pump, and solar and building performance parameters, and to optimize the solar concentrator/building area ratio for a minimum total system cost. In addition, four alternative heating cooling systems, commonly used for building comfort, are described; their costs are compared, and are found to be less competitive with the gas solar heat pump system at the projected solar equipment costs.

Lansing, F. L.↗

Combination Heat-Flux and Temperature Gage

Instrument measures both temperature and temperature gradient in confined areas. With thermopile embedded in epoxy close to thermocouple, single unit measures both temperature and heat flow. Epoxy selected for low thermal conductivity and compatibility with test environment.

Knox, E. C.↗

Solar thermal vacuum tests of Magellan spacecraft

The Magellen solar/thermal/vacuum test involved a number of unique requirements and approaches. Because of the need to operate in orbit around Venus, the solar intensity requirement ranged up to 2.3 suns or Earth equivalent solar constants. Extensive modification to the solar simulator portion of the test facility were required to achieve this solar intensity. Venus albedo and infrared emission were simulated using temperature controlled movable louver panels to allow the spacecraft to view either a selectable temperature black heat source with closed louvers, or the chamber coldwall behind open louvers. The test conditions included widely varying solar intensities, multiple sun angles, alternate hardware configurations, steady state and transient cases, and cruise and orbital power profiles. Margin testing was also performed, wherein supplemental heaters were mounted to internal thermal blankets to verify spacecraft performance at higher than expected temperatures. The test was successful, uncovering some spacecraft anomalies and verifying the thermal design. The test support equipment experienced some anomalous behavior and a significant failure during the test.

Neuman, James C.↗

Carbon Nanotube-Enhanced Carbon-Phenenolic Ablator Material

This viewgraph presentation reviews the use of PICA (phenolic impregnated carbon ablator) as the selected material for heat shielding for future earth return vehicles. It briefly reviews the manufacturing of PICA and the advantages for the use of heat shielding, and then explains the reason for using Carbon Nanotubes to improve strength of phenolic resin that binds carbon fibers together. It reviews the work being done to create a carbon nanotube enhanced PICA. Also shown are various micrographic images of the various PICA materials.

Kikolaev, P.↗

High Spatial Resolution Thermal Infrared Remote Sensing Data for Analysis of the Atlanta, Georgia, Urban Heat Island Effect and Its Impacts on the Environment

The twenty-first century is the first "urban century" according to the United Nations Development Program. The focus of cities reflects awareness of the growing percentage of the world's population that lives in urban areas. In environmental terms, cities are the original producers of many of the global problems related to waste disposal, air and water pollution, and associated environmental and ecological challenges. Expansion of cities, both in population and areal extent, is a relentless process. In 2000, approximately 3 billion people representing about 40% of the global population, resided in urban areas. Urban population will continue to rise substantially over the next several decades according to UN estimates, and most of this growth will Occur in developing countries. The UN estimates that by 2025, 60% of the world's population will live in urban areas. As a consequence, the number of"megacities" (those cities with populations of 10 million inhabitants or more) will increase by 100 by 2025. Thus, there is a critical need to understand urban areas and what their impacts are on environmental, ecological and hydrologic resources, as well as on the local, regional, and even global climate. One of the more egregious side effects of urbanization is the increase in surface and air temperatures that lead to deterioration in air quality. In the United States, under the more stringent air quality guidelines established by the U.S. Environmental Protection Agency in 1997, nearly 300 counties in 34 states will not meet these new air quality standards for ground level ozone. Mitigation of the urban heat island (UHI) effect is actively being evaluated as a possible way to reduce ground ozone levels in cities and assist states in improving air quality. Foremost in the analysis of how the UHI affects air quality and other environmental factors is the use of remote sensing technology and data to characterize urban land covers in sufficient detail to quantifiably measure the impact of increased urban heating on air quality. The urban landscape impacts surface thermal energy exchanges that determine development of the UHI. This paper will illustrate how we are using high spatial remote sensing data collected over the Atlanta, Georgia metropolitan area in conjunction with other geographic information, to perform a detailed urban land cover classification and to determine the contribution of these land covers to the urban heat island effect. Also, the spatial arrangement of the land covers and the impact on urban heating from these selected patterns of development are evaluated. Additionally, this paper will show how these data are being used as inputs to improve air quality modeling for Atlanta, including potential benefits from UHI mitigation.

Quattrochi, Dale A.↗

Sensitivity of Hollow Fiber Spacesuit Water Membrane Evaporator Systems to Potable Water Constituents, Contaminants and Air Bubbles

The Spacesuit Water Membrane Evaporator (SWME) is the baseline heat rejection technology selected for development for the Constellation lunar suit. The first SWME prototype, designed, built, and tested at Johnson Space Center in 1999 used a Teflon hydrophobic porous membrane sheet shaped into an annulus to provide cooling to the coolant loop through water evaporation to the vacuum of space. This present study describes the test methodology and planning and compares the test performance of three commercially available hollow fiber materials as alternatives to the sheet membrane prototype for SWME, in particular, a porous hydrophobic polypropylene, and two variants that employ ion exchange through non-porous hydrophilic modified Nafion. Contamination tests will be performed to probe for sensitivities of the candidate SWME elements to ordinary constituents that are expected to be found in the potable water provided by the vehicle, the target feedwater source. Some of the impurities in potable water are volatile, such as the organics, while others, such as the metals and inorganic ions are nonvolatile. The non-volatile constituents will concentrate in the SWME as evaporated water from the loop is replaced by the feedwater. At some point in the SWME mission lifecycle as the concentrations of the non-volatiles increase, the solubility limits of one or more of the constituents may be reached. The resulting presence of precipitate in the coolant water may begin to plug pores and tube channels and affect the SWME performance. Sensitivity to macroparticles, lunar dust simulant, and air bubbles will also be investigated.

Bue, Grant C.↗

On Heatshield Shapes for Mars Entry Capsules

The 70deg sphere-cone - the standard geometry for all US Mars entry missions - is thoroughly examined via flow field simulations at a select few peak heating points along candidate flight trajectories. Emphasis is placed on turbulent heating based on the Baldwin- Lomax turbulence model. It is shown that increased leeward turbulent heating for a 70 sphere-cone flying at angle of attack is primarily due to the discontinuity in curvature between the spherical nose cap and the conical frustum - the attachment of the sonic line at this sphere-cone junction leads to a supersonic edge Mach number over the leeward acreage. In an attempt to mitigate this problem of elevated turbulent heating, alternate geometries, without any curvature discontinuities in the acreage, are developed. Two approaches, one based on nonlinear optimization with constraints, and one based on the use of non-uniform rational B-splines, are considered. All configurations examined remain axisymmetric. The aerothermal performance of alternate geometries is shown to be superior to that of the 70 sphere-cone.

Prabhu, DInesh K.↗

Flowfield Analysis of a Small Entry Probe (SPRITE) Tested in an Arc Jet

Results of simulations of flow of an arc-heated stream around a 14-inch diameter 45 sphere-cone configuration are presented. Computations are first benchmarked against pressure and heat flux measurements made using copper slug calorimeters of different shapes and sizes. The influence of catalycity of copper on computed results is investigated. Good agreements between predictions and measurements are obtained by assuming the copper slug to be partially catalytic to atomic recombination. With total enthalpy estimates obtained from these preliminary computations, calculations are then performed for the test article, with the nozzle and test article considered as an integrated whole the same procedure adopted for calorimeter simulations. The resulting heat fluxes at select points on the test article (points at which fully instrumented plugs were placed) are used in material thermal response code calculations. Predicted time histories of temperature are compared against thermocouple data from the instrumented plugs, and recession determined. Good agreement is obtained for in-depth thermocouples.

Prabhu, Dinesh K.↗

Thermophotovoltaics for In-Space Nuclear Power

In-space nuclear power systems are under consideration for missions that need lots of power. Recent work in Thermophotovoltaic (TPV) cells indicates that they may be a mass efficient option for converting a nuclear reactor’s thermal energy into electrical energy. This paper briefly trades TPV versus a Brayton Cycle in the context of a conceptual Earth-to-Mars transportation system. The selection of the heat engine primarily impacts the design of the nuclear reactor, power handling electronics, fluid loops, heat exchangers, and thermal radiator, so the impact to these subsystems is also considered. The mass and electrical power generation are the primary figures of merit compared between the two alternatives, and qualitative differences are discussed.

Nuclear↗

Thermophotovoltaics for In-Space Nuclear Power

In-space nuclear power systems are under consideration for missions that need lots of power. Recent work in Thermophotovoltaic (TPV) cells indicates that they may be a mass efficient option for converting a nuclear reactor’s thermal energy into electrical energy. This paper briefly trades TPV versus a Brayton Cycle in the context of a conceptual Earth-to-Mars transportation system. The selection of the heat engine primarily impacts the design of the nuclear reactor, power handling electronics, fluid loops, heat exchangers, and thermal radiator, so the impact to these subsystems is also considered. The mass and electrical power generation are the primary figures of merit compared between the two alternatives, and qualitative differences are discussed.

Nuclear↗

Closeout Report for the Refractory Metal Accelerated Heat Pipe Life Test Activity

With the selection of a gas-cooled reactor, this heat pipe accelerated life test activity was closed out and its resources redirected. The scope of this project was to establish the long-term aging effects on Mo-44.5%Re sodium heat pipes when subjected to space reactor temperature and mass fluences. To date, investigators have demonstrated heat pipe life tests of alkali metal systems up to .50,000 hours. Unfortunately, resources have not been available to examine the effect of temperature, mass fluence, or impurity level on corrosion or to conduct post-test forensic examination of heat pipes. The key objective of this effort was to establish a cost/time effective method to systematically test alkali metal heat pipes with both practical and theoretical benefits. During execution of the project, a heat pipe design was established, a majority of the laboratory test equipment systems specified, and operating and test procedures developed. Procurements for the heat pipe units and all major test components were underway at the time the stop work order was issued. An extremely important outcome was the successful fabrication of an annular wick from Mo-5%Re screen (the single, most difficult component to manufacture) using a hot isostatic pressing technique. This Technical Publication (TP) includes specifics regarding the heat pipe calorimeter water-cooling system, vendor design for the radio frequency heating system, possible alternative calorimeter designs, and progress on the vanadium equilibration technique. The methods provided in this TP and preceding project documentation would serve as a good starting point to rapidly implement an accelerated life test. Relevant test data can become available within months, not years, and destructive examination of the first life test heat pipe might begin within 6 months of test initiation. Final conclusions could be drawn in less than a quarter of the mission duration for a long-lived, fission-powered, deep space probe.

Martin, J.↗

Analytical design and performance studies of the nuclear light bulb engine

Analytical studies were conducted to investigate in detail the heat balance characteristics of the nuclear light bulb engine. Distributions of energy deposition to all engine components from the fission process, conduction and convection, and thermal radiation were considered. Where uncertainties in basic data or heat transfer characteristics were encountered, ranges of heat loads were calculated and reference values were selected. The influence of these heat loads on engine performance, space radiator requirements, and cooling sequence and cooling circuit designs was determined. The analyses resulted in revisions to the previously reported reference engine characteristics, principally in the heat loads to some engine components and in the cooling sequence. These revisions were incorporated in the engine dynamics digital computer simulation program. No significant changes occurred in the dynamic response of the engine to perturbations in fuel injection rate, reactivity or exhaust nozzle area.

Rodgers, R. J.↗

Near-term hybrid vehicle program, phase 1. Appendix B: Design trade-off studies report. Volume 2: Supplement to design trade-off studies

Results of studies leading to the preliminary design of a hybrid passenger vehicle which is projected to have the maximum potential for reducing petroleum consumption in the near term are presented. Heat engine/electric hybrid vehicle tradeoffs, assessment of battery power source, and weight and cost analysis of key components are among the topics covered. Performance of auxiliary equipment, such as power steering, power brakes, air conditioning, lighting and electrical accessories, heating and ventilation is discussed along with the selection of preferred passenger compartment heating procedure for the hybrid vehicle. Waste heat from the engine, thermal energy storage, and an auxiliary burner are among the approaches considered.

Source record↗

Design characteristics of a heat pipe test chamber

LeRC has designed a heat pipe test facility which will be used to provide data for validating heat pipe computer codes. A heat pipe test chamber that uses helium gas for enhancing heat transfer was investigated. The conceptual design employs the technique of guarded heating and guarded cooling to facilitate accurate measurements of heat transfer rates to the evaporator and from the condenser. The design parameters are selected for a baseline heat pipe made of stainless steel with an inner diameter of 38.10 mm and a wall thickness of 1.016 mm. The heat pipe operates at a design temperature of 1000 K with an evaporator radial heat flux of 53 W/sq. cm.

Baker, Karl W.↗

Scale selection and propagation of wave-CISK with conditional heating

Analytic solutions are derived for simple models of equatorial wave-CISK with conditional (positive-only) heating. Conditional heating favors an unstable mode having a single wet region of infinitesimal width. This result helps explain model simulations of tropical superclusters and intraseasonal oscillations. Mechanisms of scale selection and propagation are discussed, and the model is generalized to include evaporation-wind feedback, multiple vertical-mode CISK, and scale-dependent damping. The first two mechanisms cause zonal propagation, without scale selection. Scale-dependent damping breaks the inviscid continuum (wherein modes exist as a continuous function of wet region width) into discrete modes with unique horizontal structure and phase speed. Results are contrasted with the hierarchy of scales in observed intraseasonal oscillations.

Dunkerton, Timothy J.↗

Working fluid selection for space-based two-phase heat transport systems

The working fluid for externally-mounted, space-based two-phase heat transport systems is considered. A sequence of screening criteria involving freezing and critical point temperatures and latent heat of vaporization and vapor density are applied to a data base of 860 fluids. The thermal performance of the 52 fluids which pass this preliminary screening are then ranked according to their impact on the weight of a reference system. Upon considering other nonthermal criteria (flammability, toxicity, and chemical stability) a final set of 10 preferred fluids is obtained. The effects of variations in system parameters is investigated for these 10 fluids by means of a factorial design.

Mclinden, Mark O.↗