Search NASA⌕ Search

SEARCH · Search NASA

Results for “selectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

114 records · Page 7

Overview of International Space Station Carbon Dioxide Removal Assembly On-Orbit Operations and Performance

Controlling Carbon Dioxide (CO2) partial pressure in the habitable vehicle environment is a critical part of operations on the International Space Station (ISS). On the United States segment of ISS, CO2 levels are primarily controlled by the Carbon Dioxide Removal Assembly (CDRA). There are two CDRAs on ISS; one in the United States Laboratory module, and one in the Node3 module. CDRA has been through several significant operational issues, performance issues and subsequent re-design of various components, primarily involving the Desiccant Adsorbent Bed (DAB) assembly and Air Selector Valves (ASV). This paper will focus on significant operational and performance issues experienced by the CDRA team from 2008-2012.

Matty, Christopher M.↗

International Space Station Environmental Control and Life Support System Status: 2012-2013

Controlling Carbon Dioxide (CO2) partial pressure in the habitable vehicle environment is a critical part of operations on the International Space Station (ISS). On the United States segment of ISS, CO2 levels are primarily controlled by the Carbon Dioxide Removal Assembly (CDRA). There are two CDRAs on ISS; one in the United States Laboratory module, and one in the Node3 module. CDRA has been through several significant operational issues, performance issues and subsequent re-design of various components, primarily involving the Desiccant Adsorbent Bed (DAB) assembly and Air Selector Valves (ASV). This paper will focus on significant operational and performance issues experienced by the CDRA team from 2008-2012.

Williams, David E.↗

Multi-Pass Quadrupole Mass Analyzer

Analysis of the composition of planetary atmospheres is one of the most important and fundamental measurements in planetary robotic exploration. Quadrupole mass analyzers (QMAs) are the primary tool used to execute these investigations, but reductions in size of these instruments has sacrificed mass resolving power so that the best present-day QMA devices are still large, expensive, and do not deliver performance of laboratory instruments. An ultra-high-resolution QMA was developed to resolve N2 +/CO+ by trapping ions in a linear trap quadrupole filter. Because N2 and CO are resolved, gas chromatography columns used to separate species before analysis are eliminated, greatly simplifying gas analysis instrumentation. For highest performance, the ion trap mode is used. High-resolution (or narrow-band) mass selection is carried out in the central region, but near the DC electrodes at each end, RF/DC field settings are adjusted to allow broadband ion passage. This is to prevent ion loss during ion reflection at each end. Ions are created inside the trap so that low-energy particles are selected by low-voltage settings on the end electrodes. This is beneficial to good mass resolution since low-energy particles traverse many cycles of the RF filtering fields. Through Monte Carlo simulations, it is shown that ions are reflected at each end many tens of times, each time being sent back through the central section of the quadrupole where ultrahigh mass filtering is carried out. An analyzer was produced with electrical length orders of magnitude longer than its physical length. Since the selector fields are sized as in conventional devices, the loss of sensitivity inherent in miniaturizing quadrupole instruments is avoided. The no-loss, multi-pass QMA architecture will improve mass resolution of planetary QMA instruments while reducing demands on the RF electronics for high-voltage/high-frequency production since ion transit time is no longer limited to a single pass. The QMA-based instrument will thus give way to substantial reductions of the mass of flight instruments.

Prestage, John D.↗

Space Environments and Effects Program (SEE)

The need to preserve works and NASA documented articles is done via the collection of various Space Environments and Effects (SEE) related articles. (SEE) contains and lists the various projects that are ongoing, or have been conducted with the help of NASA. The goal of the (SEE) program is to make publicly available the environment technologies that are required to design, manufacture and operate reliable, cost-effective spacecraft for the government and commercial sectors. Of the many projects contained within the (SEE) program the Lunar-E Library and Spacecraft Materials Selector (SMS) have been selected for a more user friendly means to make the tools easily available to the public. This information which is still available required a person or entity to request access from a point of contact at NASA and wait for the requested bundled software DVD via postal service. Redesigning the material presentation and availability has been mapped to a single step process with faster turnaround time via Materials and Processes Technical Information System (MAPTIS) database. This process requires users to register and be verified in order to gain access to the information contained within. Aiding in the progression of making the software tools/documents available required a combination of specialized in-house data gathering software tools and software archeology.

Yhisreal-Rivas, David M.↗

Successful Demonstration of an Electrostatic Actuated Microshutter System for Space Telescope Flight Missions

After developing magnetically actuated microshutter array sub-systems as a field object selector for the James Webb Space Telescope (JWST), a team at the NASA Goddard Space Flight Center (GSFC) focused on the development of electrostatically actuated microshutter arrays – Next Generation Microshutter Arrays (NGMSA). The demonstration described in this late news is for the first NGMSA array that performed shutter operations for telescope imaging and spectroscopy in space. The carrier telescope, the Next-Generation Far-UV Off Roland-circle Telescope for Imaging and Spectroscopy (NG-FORTIS), has been designed and produced by Prof. Stephan McCandliss and his team at Johns Hopkins University. NG-FORTIS was launched into space successfully.

M. J. Li↗

MEDPRAT Treatment Clusters: Improving Representation of Mission Medical Risk

INTRODUCTION The Medical Extensible Dynamic Probabilistic Risk Assessment Tool (MEDPRAT) implements a computational model that aims to quantify spaceflight medical risk by utilizing probabilistic techniques to simulate critical event incidence and outcomes over thousands of simulated mission trials. The goal of MEDPRAT is to characterize mission medical risk and provide insight into medical resource utilization. In order to analyze the medical resource space, treatment must be mapped from each simulated condition, and resources consumed as a result of this treatment must be tracked throughout the course of the mission. A new MEDPRAT feature, ‘treatment clusters’, provide a more sophisticated method of defining the structure and interaction between resources, more closely mimicking the way treatment is carried out clinically. METHODS Treatment clusters expand on the two existing treatment groupings (combination and alternate) adding a new grouping: bundled treatment. Treatment clusters may be combined to any depth, giving users the ability to specify complex treatment trees whose behavior is governed by several user-specified parameters. This approach emphasizes reusability, as treatment clusters, once defined, can be used to create more complex treatment trees or applied to many conditions. By configuring parameters for contribution, efficacy, necessity, primacy, and equivalence, resource relationships and dependencies can be more accurately represented, thereby allowing users to build capabilities with desired treatment properties, for example an intravenous capability for conditions such as anaphylaxis, acute radiation syndrome, etc. MEDPRAT v1.0 remains backward compatible with existing treatment structures, giving users the ability to define new treatment clusters as evidence becomes available, without having to recode their existing treatment databases. In addition to facilitating the representation of more complex treatment options, by pairing treatment clusters with the internal optimization routine, the MEDPRAT set selector, medical resources can be identified as organized in bundles, where appropriate, so that optimized resource sets include groups of highly-dependent resources only when all resources of the group are together. For example, it would be wasteful to include ultrasound gel but not an ultrasound machine, since the gel provides no benefit as a treatment without the ultrasound machine. With treatment clusters, the user may require that both resources are available to provide any benefit as treatment, so that if one resource is optimized out of the set, the other resource will be optimized out as well. RESULTS AND CONCLUSIONS We will report on MEDPRAT treatment clusters used in a bundling study under the IMPACT project of the ExMC element. We will discuss an example of a complex treatment tree. Through the implementation of this feature MEDPRAT enables treatment to be defined and applied in a way that is more representative of the real world, providing more accurate insight into mission medical risk and the medical resource space.

Lawrence Leinweber↗