Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Accuracy and Usefulness of Select Methods for Assessing Complete Collection of 24‐Hour Urine: A Systematic Review

Twenty‐four–hour urine collection is the recommended method for estimating sodium intake. To investigate the strengths and limitations of methods used to assess completion of 24‐hour urine collection, the authors systematically reviewed the literature on the accuracy and usefulness of methods vs para‐aminobenzoic acid ( PABA ) recovery (referent). The percentage of incomplete collections, based on PABA , was 6% to 47% (n=8 studies). The sensitivity and specificity for identifying incomplete collection using creatinine criteria (n=4 studies) was 6% to 63% and 57% to 99.7%, respectively. The most sensitive method for removing incomplete collections was a creatinine index <0.7. In pooled analysis (≥2 studies), mean urine creatinine excretion and volume were higher among participants with complete collection ( P <.05); whereas, self‐reported collection time did not differ by completion status. Compared with participants with incomplete collection, mean 24‐hour sodium excretion was 19.6 mmol higher (n=1781 specimens, 5 studies) in patients with complete collection. Sodium excretion may be underestimated by inclusion of incomplete 24‐hour urine collections. None of the current approaches reliably assess completion of 24‐hour urine collection.

John, Katherine A.↗

Evaluating IMRT and VMAT dose accuracy: Practical examples of failure to detect systematic errors when applying a commonly used metric and action levels

Purpose: This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detailing these case studies is to explore different, more sensitive methods and metrics that could be used more effectively for evaluating accuracy of dose algorithms, delivery systems, and QA devices.Methods: The authors present seven real-world case studies representing a variety of combinations of the treatment planning system (TPS), linac, delivery modality, and systematic error type. These case studies are typical to what might be used as part of an IMRT or VMAT commissioning test suite, varying in complexity. Each case study is analyzed according to TG-119 instructions for gamma passing rates and action levels for per-beam and/or composite plan dosimetric QA. Then, each case study is analyzed in-depth with advanced diagnostic methods (dose profile examination, EPID-based measurements, dose difference pattern analysis, 3D measurement-guided dose reconstruction, and dose grid inspection) and more sensitive metrics (2% local normalization/2 mm DTA and estimated DVH comparisons).Results: For these case studies, the conventional 3%/3 mm gamma passing rates exceeded 99% for IMRT per-beam analyses and ranged from 93.9% to 100% for composite plan dose analysis, well above the TG-119 action levels of 90% and 88%, respectively. However, all cases had systematic errors that were detected only by using advanced diagnostic techniques and more sensitive metrics. The systematic errors caused variable but noteworthy impact, including estimated target dose coverage loss of up to 5.5% and local dose deviations up to 31.5%. Types of errors included TPS model settings, algorithm limitations, and modeling and alignment of QA phantoms in the TPS. Most of the errors were correctable after detection and diagnosis, and the uncorrectable errors provided useful information about system limitations, which is another key element of system commissioning.Conclusions: Many forms of relevant systematic errors can go undetected when the currently prevalent metrics for IMRT/VMAT commissioning are used. If alternative methods and metrics are used instead of (or in addition to) the conventional metrics, these errors are more likely to be detected, and only once they are detected can they be properly diagnosed and rooted out of the system. Removing systematic errors should be a goal not only of commissioning by the end users but also product validation by the manufacturers. For any systematic errors that cannot be removed, detecting and quantifying them is important as it will help the physicist understand the limits of the system and work with the manufacturer on improvements. In summary, IMRT and VMAT commissioning, along with product validation, would benefit from the retirement of the 3%/3 mm passing rates as a primary metric of performance, and the adoption instead of tighter tolerances, more diligent diagnostics, and more thorough analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

Local Power-Voltage Sensitivity and Thevenin Impedance Estimation from Phasor Measurements

This paper describes how to use voltage phasor measurements to produce a sensitivity matrix that describes how real and reactive power injections at a node on a distribution network affect the local voltage magnitude and angle. Rather than estimating the sensitivity directly, the voltage phasor measurements and power commands/measurements are used to estimate the unbalanced, three-phase Thevenin impedance. The Thevenin impedance estimation is conducted using recursive least squares on temporal difference measurements. The Thevenin impedance and voltage phasor measurement are then used to build the local power-voltage sensitivity matrix with the closed form expression for the Jacobian of the power flow manifold. Hardware-in-the-loop simulations with phasor measurement units providing real phasor measurements are used to evaluate the recursive temporal difference Thevenin impedance estimation and Thevenin-based power-voltage sensitivity methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring Charged Defects in Ferroelectrics by the Switching Spectroscopy Piezoresponse Force Microscopy

Monitoring the charged defect concentration at the nanoscale is of critical importance for both the fundamental science and applications of ferroelectrics. However, up-to-date, high-resolution study methods for the investigation of structural defects, such as transmission electron microscopy, X-ray tomography, etc., are expensive and demand complicated sample preparation. Here, with an example of the lanthanum-doped bismuth ferrite ceramics, a novel method is proposed based on the switching spectroscopy piezoresponse force microscopy (SSPFM) that allows probing the electric potential from buried subsurface charged defects in the ferroelectric materials with a nanometer-scale spatial resolution. When compared with the composition-sensitive methods, such as neutron diffraction, X-ray photoelectron spectroscopy, and local time-of-flight secondary ion mass spectrometry, the SSPFM sensitivity to the variation of the electric potential from the charged defects is shown to be equivalent to less than 0.3 at% of the defect concentration. Additionally, the possibility to locally evaluate dynamics of the polarization screening caused by the charged defects is demonstrated, which is of significant interest for further understanding defect-mediated processes in ferroelectrics.

42 ENGINEERING↗

Spectral Methods of Remote-Sensing Monitoring of Radioactive Substances and Toxic Chemicals

The physical principles of passive and active methods of remote-sensing monitoring of radioactive substances and toxic chemicals in accidental emissions (leaks) at nuclear fuel cycle objects are examined. The analytical possibilities of the most sensitive methods of remote-sensing monitoring, which are based on the advances made in UV and microwave range radiometry, laser IR-absorption spectroscopy, laser-induced fluorescence, and laser spark emission spectrometry, are discussed. The prospects for the development of spectral methods of remote-sensing monitoring in different ranges are analyzed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study of the defect structure of paratellurite crystal using multiwave diffraction and normal X-ray diffractometry methods

Multiwave X-ray diffraction has been used to study the structure of crystalline samples. A cycle of local measurements of rocking curves (RCs) of the (220) and (371) reflections under conditions of multiwave diffraction (MD) has been carried out in a paratellurite crystal. The data obtained are used to compare the sensitivity to structure defects of two-beam diffraction with that of MD, which makes it possible to study the X-ray wave phase. The comparison has revealed a higher ability of the phase-sensitive method to detect defects.

36 MATERIALS SCIENCE↗

Variance-based sensitivity indices for stochastic models with correlated inputs

The goal of this article is the formulation of the principles of one of the possible strategies in implementing correlation between input random variables so as to be usable for algorithm development and the evaluation of Sobol’s sensitivity analysis. With regard to the types of stochastic computational models, which are commonly found in structural mechanics, an algorithm was designed for effective use in conjunction with Monte Carlo methods. Sensitivity indices are evaluated for all possible permutations of the decorrelation procedures for input parameters. The evaluation of Sobol’s sensitivity coefficients is illustrated on an example in which a computational model was used for the analysis of the resistance of a steel bar in tension with statistically dependent input geometric characteristics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-579: On the Relative Sensitivity of Monte Carlo and Pencil Beam Dose Calculation Algorithms to CT Metal Artifacts in Volumetric-Modulated Arc Spine Radiosurgery (RS)

Purpose: Investigating the relative sensitivity of Monte Carlo (MC) and Pencil Beam (PB) dose calculation algorithms to low-Z (titanium) metallic artifacts is important for accurate and consistent dose reporting in post¬operative spinal RS. Methods: Sensitivity analysis of MC and PB dose calculation algorithms on the Monaco v.3.3 treatment planning system (Elekta CMS, Maryland Heights, MO, USA) was performed using CT images reconstructed without (plain) and with Orthopedic Metal Artifact Reduction (OMAR; Philips Healthcare system, Cleveland, OH, USA). 6MV and 10MV volumetric-modulated arc (VMAT) RS plans were obtained for MC and PB on the plain and OMAR images (MC-plain/OMAR and PB-plain/OMAR). Results: Maximum differences in dose to 0.2cc (D0.2cc) of spinal cord and cord +2mm for 6MV and 10MV VMAT plans were 0.1Gy between MC-OMAR and MC-plain, and between PB-OMAR and PB-plain. Planning target volume (PTV) dose coverage changed by 0.1±0.7% and 0.2±0.3% for 6MV and 10MV from MC-OMAR to MC-plain, and by 0.1±0.1% for both 6MV and 10 MV from PB-OMAR to PB-plain, respectively. In no case for both MC and PB the D0.2cc to spinal cord was found to exceed the planned tolerance changing from OMAR to plain CT in dose calculations. Conclusion: Dosimetric impacts of metallic artifacts caused by low-Z metallic spinal hardware (mainly titanium alloy) are not clinically important in VMAT-based spine RS, without significant dependence on dose calculation methods (MC and PB) and photon energy ≥ 6MV. There is no need to use one algorithm instead of the other to reduce uncertainty for dose reporting. The dose calculation method that should be used in spine RS shall be consistent with the usual clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-567: Sensitivity and Reproducibility of the Portal Imaging Panel for Routine FFF QC and Patient Plan Dose Measurements

Purpose: The purpose of this work was to see if the EPID is a viable alternative to other QA devices for routine FFF QA and plan dose measurements. Methods: Sensitivity measurements were made to assess response to small changes in field size and beam steering. QA plans were created where field size was varied from baseline values (5–5.5cm, 20–20.5cm). Beam steering was adjusted by altering values in service mode (Symmetry 0–3%). Plans were measured using the Varian portal imager (aS1200 DMI panel), QA3 (Sun Nuclear), and Starcheck Maxi (PTW). FFF beam parameters as stated in Fogliata et al were calculated. Constancy measurements were taken using all 3 QC devices to measure a MLC defined 20×20cm field. Two clinical SABR patient plans were measured on a Varian Edge linac, using the Portal Dosimetry module in ARIA, and results compared with analysis made using Delta4 (ScandiDos). Results: The EPID and the Starcheck performed better at detecting clinically relevant changes in field size with the QA3 performing better when detecting similar changes in beam symmetry. Consistency measurements with the EPID and Starcheck were equivalent, with comparable standard deviations. Clinical plan measurements on the EPID compared well with Delta4 results at 3%/1mm. Conclusion: Our results show that for FFF QA measurements such as field size and symmetry, using the EPID is a viable alternative to other QA devices. The EPID could potentially be used for QC measurements with a focus on geometric accuracy, such as MLC positional QA, due to its high resolution compared to other QA devices (EPID 0.34mm, Starcheck 3mm, QA3 5mm). Good agreement between Delta4 and portal dosimetry also indicated the EPID may be a suitable alternative for measurement of clinical plans.

60 APPLIED LIFE SCIENCES↗

From genomes to metabolomes: Understanding mechanisms of symbiosis and cell-cell signaling using the archaeal system Ignicoccus-Nanoarchaeum

The main objective of this project was to use symbiotic Nanoarchaeaota, a group of thermophilic Archaea that are obligate symbionts/parasites on other Archaea, to develop an integrated multi-omic approach to study inter-species interactions as well as to understand fundamental mechanism that enable such relationships. As part of this grant we have achieved a number of important milestone on both technical and scientific levels. On the technical side, we developed immunofluorescence labeling and tracking methods to follow Nanoarchaeota in cultures and in environmental samples, we applied such methods in conjunction with flow cytometry to quantify and isolate uncultured representatives from the environment and characterized them by single cell genomics. On the proteomics side, we developed a more efficient and sensitive method to recover and semi-quantitatively measure membrane proteins, while achieving high total cellular proteome coverage (70-80% of the predicted proteome). Metabolomic analyses used complementary NMR and LC/GC mass spectrometry and led to the identification of novel lipids in these organisms as well as quantification of some of the major metabolites. Importantly, using several informatics approaches we were also able to integrate the transcriptomic, proteomic and metabolomic datasets, revealing aspects of the interspecies interaction that were not evident in the single omic analyses (manuscript in review). On the science side we determined that N. equitans and I. hospitalis are metabolically coupled and that N. equitans is strictly dependent on its host both for metabolic precursors and energetic needs. The actual mechanism by which small molecules move across the cell membrane remains unknown. The Ignicoccus host responds to the metabolic and energetic burned by upregulating of key primary metabolism steps and ATP synthesis. The two species have co-evolved, aspect that we determined by comparative genomics with other species of Ignicoccus (manuscript in preparation) and by characterizing other similar Nanoarchaeota systems. Using a single cell genomics approach we characterized the first terrestrial geothermal Nanoarchaeota system, from Yellowstone National Park. That nanoarchaeon uses a different host, a species of Sulfolobales, and comparative genomics with N. equitans-Ignicoccus allowed us to come up with an evolutionary model for the evolution of this group of organisms across marine and terrestrial ecosystems. Based on metabolic inferences we were also able to isolate in culture the first such terrestrial nanoarchaeal system, also from Yellowstone, which involves a species of Acidilobus. The novel nanoarchaeal system was characterized using proteomics and it helped us better understand the metabolic capabilities of these organisms as well as how co-evolution shapes the genomes of interacting species. It was also one of the very few cases in which prior genomic data was used to successfully design an approach to culture an organism, which remains the gold standard in microbiology research. As a better understanding of interspecies interaction requires multiple model systems, we have pursued identification and genomic characterization or isolation of additional nanoarchaeal systems from geographically and geochemically distinct environments. Two additional nanoarchaeal systems are presently being characterized from hot springs in Yellowstone and Iceland and will be the subject to future publications.

59 BASIC BIOLOGICAL SCIENCES↗

Prediction of Intrafraction Prostate Motion: Accuracy of Pre- and Post-Treatment Imaging and Intermittent Imaging

Purpose: To evaluate whether pre- and post-treatment imaging (immediately before and after a radiation therapy treatment fraction) and intermittent imaging (at intervals during a treatment fraction) are accurate predictors of prostate motion during the delivery of radiation. Methods and Materials: The Calypso 4D Localization System was used to continuously track the prostate during radiation delivery in 35 prostate cancer patients, for a total of 1,157 fractions (28-45 per patient). Predictions of prostate motion away from isocenter were modeled for a pre- and post-treatment imaging schedule and for multiple intermittent intrafraction imaging schedules and compared with the actual continuous tracking data. The endpoint was drift of the prostate beyond a certain radial displacement for a duration of more than 30 s, 1 min, and 2 min. Results were used to evaluate the sensitivity and specificity of these models as an evaluation of intrafraction prostate motion. Results: The sensitivity of pre- and post-treatment imaging in determining 30 s of intrafraction prostate motion greater than 3, 5, or 7 mm for all fractions was low, with values of 53%, 49%, and 39%, respectively. The specificity of pre- and post-treatment imaging was high for all displacements. The sensitivity of intermittent imaging improved with increasing sampling rate. Conclusions: These results suggest that pre- and post-treatment imaging is not a sensitive method of assessing intrafraction prostate motion, and that intermittent imaging is sufficiently sensitive only at a high sampling rate. These findings support the value of continuous, real-time tracking in prostate cancer radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calculating uncertainty on K-effective with MONK10 - 14583

Criticality safety assessments require a demonstration that a particular configuration of fissile material has an adequate sub-critical margin (k-effective sufficiently below unity) to ensure that the risk of criticality under normal operation and accident conditions is acceptable. The required sub-critical margin depends upon the uncertainty in the estimated value of k-effective. The uncertainty in the calculated value of k-effective arises from a number of sources, including: manufacturing tolerances on input data to the code (affecting geometry, compositions and densities), uncertainty in the nuclear data used by the code, stochastic uncertainty resulting from Monte Carlo simulation and modelling approximations/errors, including the inevitable bugs in the software. The ANSWERS Software Service, in collaboration with industrial partners, is developing a number of techniques to better understand and quantify uncertainty on predicted values of k-effective, using MONK. The SPRUCE utility code has been developed to allow uncertainty to be estimated using sampling methods. This can include the sampling of input parameters (including dimensions, compositions and densities) from statistical distributions. It can also include sampling different nuclear data libraries. A set of nuclear data libraries has been generated for this purpose by sampling from statistical distributions that represent the uncertainties in the published nuclear data evaluated files; a set of libraries has been produced for Latin Hypercube Sampling. By varying the input data and nuclear data, separate and combined uncertainties due to manufacturing tolerances and nuclear data can be derived. By performing least squares fitting on the results it is also possible to estimate the contribution of each of the uncertain inputs and a sensitivity method in MONK can break down the nuclear data uncertainty. (authors)

42 ENGINEERING↗

Irradiation-Induced Regulation of Plasminogen Activator Inhibitor Type-1 and Vascular Endothelial Growth Factor in Six Human Squamous Cell Carcinoma Lines of the Head and Neck

Purpose: It has been shown that plasminogen activator inhibitor type-1 (PAI-1) and vascular endothelial growth factor (VEGF) are involved in neo-angiogenesis. The aim of this study was to investigate the irradiation-induced regulation of PAI-1 and VEGF in squamous cell carcinomas of the head and neck (SCCHN) cell lines of varying radiation sensitivity. Methods and Materials: Six cell lines derived from SCCHN were investigated in vitro. The colorimetric AlamarBlue assay was used to detect metabolic activity of cell lines during irradiation as a surrogate marker for radiation sensitivity. PAI-1 and VEGF secretion levels were measured by enzyme-linked immunosorbent assay 24, 48, and 72 h after irradiation with 0, 2, 6, and 10 Gy. The direct radioprotective effect of exogenous PAI-1 was measured using the clonogenic assay. For regulation studies, transforming growth factor-beta1 (TGF-beta1), hypoxia-inducible factor-1alpha (HIF-1alpha), hypoxia-inducible factor-2alpha (HIF-2alpha), or both HIF-1alpha and HIF-2alpha were downregulated using siRNA. Results: Although baseline levels varied greatly, irradiation led to a comparable dose-dependent increase in PAI-1 and VEGF secretion in all six cell lines. Addition of exogenous stable PAI-1 to the low PAI-1-expressing cell lines, XF354 and FaDu, did not lead to a radioprotective effect. Downregulation of TGF-beta1 significantly decreased VEGF secretion in radiation-sensitive XF354 cells, and downregulation of HIF-1alpha and HIF-2alpha reduced PAI-1 and VEGF secretion in radiation-resistant SAS cells. Conclusions: Irradiation dose-dependently increased PAI-1 and VEGF secretion in all SCCHN cell lines tested regardless of their basal levels and radiation sensitivity. In addition, TGF-beta1 and HIF-1alpha could be partly responsible for VEGF and PAI-1 upregulation after irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FAITH – Fast Assembly Inhibitor Test for HIV

Due to the high number of drug-resistant HIV-1 mutants generated by highly active antiretroviral therapy (HAART), there is continuing demand for new types of inhibitors. Both the assembly of the Gag polyprotein into immature and mature HIV-1 particles are attractive candidates for the blocking of the retroviral life cycle. Currently, no therapeutically-used assembly inhibitor is available. One possible explanation is the lack of a reliable and simple assembly inhibitor screening method. To identify compounds potentially inhibiting the formation of both types of HIV-1 particles, we developed a new fluorescent high-throughput screening assay. This assay is based on the quantification of the assembly efficiency in vitro in a 96-well plate format. The key components of the assay are HIV-1 Gag-derived proteins and a dual-labelled oligonucleotide, which emits fluorescence only when the assembly of retroviral particles is inhibited. The method was validated using three (CAI, BM2, PF74) reported assembly inhibitors. - Highlights: • Allows screening of assembly inhibitors of both mature and immature HIV-1 particles. • Based on Gag-derived proteins with CA in mature or immature conformation. • Simple and sensitive method suitable for high-throughput screening of inhibitors. • Unlike in other HIV assembly methods, works under physiological conditions. • No washing steps are necessary.

60 APPLIED LIFE SCIENCES↗

Confocal-Raman Microscopy Characterization of Supported Phospholipid Bilayers Deposited on the Interior Surfaces of Chromatographic Silica

A typical approach to exploring the structure and dynamics of biological membranes is through the deposition of model lipid bilayers on planar supports by Langmuir-trough or vesicle-fusion methods. Planar-supported lipid bilayers have been shown to exhibit structure and properties similar to those of lipid-vesicle membranes and are suitable for biosensing applications. Investigations using these planar-membrane models are limited to high-sensitivity methods capable of detecting a small population of molecules at the interface between a planar support and aqueous solution. In this work, we present evidence that supported-lipid bilayers can be deposited by vesicle fusion onto the interior surfaces throughout the wide-pore network of chromatographic silica particles. The thickness of a 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) film and headgroup spacing are consistent with a single bilayer of DMPC deposited onto the pore surfaces. The high specific surface area of these materials generates phospholipid concentrations easily detected by confocal-Raman microscopy within an individual particle, which allows the structure of these supported bilayers to be investigated. Raman spectra of porous-silica-supported DMPC bilayers are equivalent to spectra of DMPC vesicle membranes, both above and below their melting phase transitions, suggesting comparable phospholipid organization and bilayer structure. These porous-silica-supported model membranes could share benefits that planar-supported lipid bilayers bring to biosensing applications, but in a material that overcomes the limited surface area of a planar support. To try this concept, the potential of these porous-silica-supported lipid bilayers as high-surface-area platforms for label-free Raman-scattering-based protein biosensing is demonstrated with detection of concanavalin A selectively binding to a lipid-immobilized mannose target.

36 MATERIALS SCIENCE↗

Defect Quantification in Metal Halide Perovskites Anticipates Photoluminescence and Photovoltaic Performance

Semiconductor material optimization requires quantification of performance and stability-dependent near-valence maximum and near-conduction minimum defects with sufficient energy resolution and sensitivity. In this work, we utilize a spectroscopy-electrochemistry approach to resolve the energy-distinct donor and acceptor defect concentrations in wide-gap (Cs .05 FA .79 MA .16 )Pb(I .87 Br .13 ) 3 perovskites, benchmarked against photoluminescence and photovoltaic device performance. Monitoring charge transfer events to electron acceptor and donor molecules within solid electrolyte top contacts enables defect quantification below 10 15 cm –3 at an energy resolution of 10 meV under device-relevant bias, well below levels reported by other methods. Further method sensitivity is demonstrated for defects arising from <2% formamidinium concentration modifications, mimicking compositional imperfections resulting from nonoptimized processing. This method provides the first complete perovskite energetic diagrams with small changes in composition, is nondestructive, compatible with in-line processing characterization, and will enable the semiconductor community to link molecular origins of defects with limitations in device performance across a wide array of optoelectronic platforms.

14 SOLAR ENERGY↗

Ultrasmall particle detection using a submicron Hall sensor

We demonstrate detection of a single FePt nanoparticle (diameter 150 nm, moment {approx}10{sup 7} {mu}{sub B}) using an ultrasensitive InSb Hall sensor with the bar lateral width of 600 nm. The white noise of a typical nanodevice, S{sub V}{sup 1/2{approx_equal}}28 nV/{radical}Hz, is limited only by two-terminal resistance of the voltage leads which results in a minimum field sensitivity of the device B{sub min}=0.87 {mu}T/{radical}Hz. To detect a single FePt bead, we employed a phase-sensitive method based on measuring the ac susceptibility change in a bead when exposed to a switched dc magnetic field. Such nano-Hall devices, enabling detection of potentially even smaller moments, are of considerable significance both for nanomagnetic metrology and high sensitivity biological and environmental detectors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Snekmer: a scalable pipeline for protein sequence fingerprinting based on amino acid recoding

Abstract Motivation The vast expansion of sequence data generated from single organisms and microbiomes has precipitated the need for faster and more sensitive methods to assess evolutionary and functional relationships between proteins. Representing proteins as sets of short peptide sequences (kmers) has been used for rapid, accurate classification of proteins into functional categories; however, this approach employs an exact-match methodology and thus may be limited in terms of sensitivity and coverage. We have previously used similarity groupings, based on the chemical properties of amino acids, to form reduced character sets and recode proteins. This amino acid recoding (AAR) approach simplifies the construction of protein representations in the form of kmer vectors, which can link sequences with distant sequence similarity and provide accurate classification of problematic protein families. Results Here, we describe Snekmer, a software tool for recoding proteins into AAR kmer vectors and performing either (i) construction of supervised classification models trained on input protein families or (ii) clustering for de novo determination of protein families. We provide examples of the operation of the tool against a set of nitrogen cycling families originally collected using both standard hidden Markov models and a larger set of proteins from Uniprot and demonstrate that our method accurately differentiates these sequences in both operation modes. Availability and implementation Snekmer is written in Python using Snakemake. Code and data used in this article, along with tutorial notebooks, are available at http://github.com/PNNL-CompBio/Snekmer under an open-source BSD-3 license. Supplementary information Supplementary data are available at Bioinformatics Advances online.

59 BASIC BIOLOGICAL SCIENCES↗