Search NASA⌕ Search

SEARCH · Search NASA

Results for “shot noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Bi-chromatic intensity squeezing using four-wave mixing in 85 Rb vapor

We experimentally investigate four-wave mixing (FWM) in a diamond interaction scheme using 85 Rb vapor, and identify the optimal conditions for joint amplification and relative intensity squeezing of two optical fields: one near the 85 Rb D1 optical transition (λ = 794.6 nm) and the other in the telecom O-band (λ = 1324 nm). We achieved a reduction of relative intensity noise by up to 2.6 ± 0.4 dB compared with the shot noise level, signifying the non-classical quantum correlations. The observed level of intensity squeezing is primarily limited by the available pump laser power, which constrains the achievable FWM gain. Numerical simulations show good agreement with the experimental results.

74 ATOMIC AND MOLECULAR PHYSICS↗

Noise as a tool for evaluating the activation of cathodes

Measurements, at low frequencies, of the shot noise current from space charge limited cathodes always produced results substantially in excess of theoretical predictions. Measuring the ratio (I sub eq)/S yielded a relation (I sub eq)/S = 1.288 V sub k = 1.288 k(T sub k)/e, independent of the operating point of the diode (triode) as long as all parts of the cathode had a full space charge controlled emission. This method was so sensitive as to permit detection of cathode temperature changes by 1 K, thus it allowed a powerful screening method between well and poorly activated cathodes, superior to dip tests and other current-voltage methods.

Kosmahl, H.↗

Active frequency stabilization of a 1.062-micron, Nd:GGG, diode-laser-pumped nonplanar ring oscillator to less than 3 Hz of relative linewidth

Results are presented on the frequency stabilization of two diode-laser-pumped ring lasers that are independently locked to the same high-finesse interferometer. The relative frequency stability is measured by locking the lasers one free spectral range apart and observing the heterodyne beat note. The resultant beat note width of 2.9 Hz is consistent with the theoretical system noise-limited linewidth and is approximately 20 times that expected for shot-noise-limited performance.

Day, T.↗

Multi-tracer intensity mapping: cross-correlations, line noise & decorrelation

Line intensity mapping (LIM) is a rapidly emerging technique for constraining cosmology and galaxy formation using multi-frequency, low angular resolution maps. Many LIM applications crucially rely on cross-correlations of two line intensity maps, or of intensity maps with galaxy surveys or galaxy/CMB lensing. We present a consistent halo model to predict all these cross-correlations and enable joint analyses, in 3D redshift-space and for 2D projected maps. We extend the conditional luminosity function formalism to the multi-line case, to consistently account for correlated scatter between multiple galaxy line luminosities. This allows us to model the scale-dependent decorrelation between two line intensity maps, a key input for foreground rejection and for approaches that estimate auto-spectra from cross-spectra. This also enables LIM cross-correlations to reveal astrophysical properties of the interstellar medium inacessible with LIM auto-spectra. We expose the different sources of luminosity scatter or "line noise" in LIM, and clarify their effects on the 1-halo and galaxy shot noise terms. In particular, we show that the effective number density of halos can in some cases exceed that of galaxies, counterintuitively. Using observational and simulation input, we implement this halo model for the Hα, [Oiii], Lyman-α, CO and [Cii] lines. Here, we encourage observers and simulators to measure galaxy luminosity correlation coefficients for pairs of lines whenever possible. Our code is publicly available at https://github.com/EmmanuelSchaan/HaloGen/tree/LIM. In a companion paper, we use this halo model formalism and code to highlight the degeneracies between cosmology and astrophysics in LIM, and to compare the LIM observables to galaxy detection for a number of surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

FM noise and clicks

Large carrier to noise ratios in FM receivers as function of correlation between Gaussian and impulse shot noise /clicks/

Hess, D. T.↗

Real-time image denoising of mixed Poisson–Gaussian noise in fluorescence microscopy images using ImageJ

Fluorescence microscopy imaging speed is fundamentally limited by the measurement signal-to-noise ratio (SNR). To improve image SNR for a given image acquisition rate, computational denoising techniques can be used to suppress noise. However, common techniques to estimate a denoised image from a single frame either are computationally expensive or rely on simple noise statistical models. These models assume Poisson or Gaussian noise statistics, which are not appropriate for many fluorescence microscopy applications that contain quantum shot noise and electronic Johnson–Nyquist noise, therefore a mixture of Poisson and Gaussian noise. In this paper, we show convolutional neural networks (CNNs) trained on mixed Poisson and Gaussian noise images to overcome the limitations of existing image denoising methods. The trained CNN is presented as an open-source ImageJ plugin that performs real-time image denoising (within tens of milliseconds) with superior performance (SNR improvement) compared to conventional fluorescence microscopy denoising methods. The method is validated on external datasets with out-of-distribution noise, contrast, structure, and imaging modalities from the training data and consistently achieves high-performance ( > <#comment/> 8 d B ) denoising in less time than other fluorescence microscopy denoising methods.

47 OTHER INSTRUMENTATION↗

A novel electron tunneling infrared detector

The pneumatic infrared detector, originally developed by Golay in the late 1940s, uses the thermal expansion of one cm(exp 3) of xenon at room temperature to detect the heat deposited by infrared radiation. This detector was limited by thermal fluctuations within a 10 Hz bandwidth, but suffered from long thermal time constants and a fragile structure. Nevertheless, it represents the most sensitive room temperature detector currently available in the long wavelength infrared (LWIR). Fabrication of this type of detector on smaller scales has been limited by the lack of a suitably sensitive transducer. Researchers designed a detector based on this principle, but which is constructed entirely from micromachined silicon, and uses a vacuum tunneling transducer to detect the expansion of the trapped gas. Because this detector is fabricated using micromachining techniques, miniaturization and integration into one and two-dimensional arrays is feasible. The extreme sensitivity of vacuum tunneling to changes in electrode separation will allow a prototype of this detector to operate in the limit of thermal fluctuations over a 10 kHz bandwidth. A calculation of the predicted response and noise of the prototype is presented with the general formalism of thermal detectors. At present, most of the components of the prototype have been fabricated and tested independently. In particular, a characterization of the micromachined electron tunneling transducer has been carried out. The measured noise in the tunnel current is within a decade of the limit imposed by shot noise, and well below the requirements for the operation of an infrared detector with the predicted sensitivity. Assembly and characterization of the prototype infrared detector will be carried out promptly.

Kenny, T. W.↗

Squeezed Light Stimulated Raman Scattering (SRS) Microscopy for Bioenergy Applications

Stimulated Raman scattering (SRS) microscopy using picosecond near-IR pulses have provided a great penetration depth with reduced fluorescence interference when imaging biological samples for bioenergy applications. These tools have provided insight into 1) tracking the degradation of chemical composites in biomass feedstocks to investigate the recalcitrant factors during the deconstruction processes, 2) monitoring the production of chemicals in photosynthetic plants and wood-digesting microorganisms, and 3) probing plant-bacteria interactions. However, the above processes are usually slow and require continuous imaging for an extended period. This is challenging for classic SRS because the laser power needed to achieve enough sensitivity causes photodamage in the samples during such long experiments. Quantum-squeezed light with reduced noise in the intensity quadrature can improve the sensitivity of classic SRS microscopy beyond the shot noise limit. The successful squeezing of one of the picosecond pulses in the above SRS will improve sensitivity and reduce photodamage, greatly expanding the range of studies available to SRS microscopy.

BIOMASS FUELS↗

Linear restoration of incoherently radiating objects.

Light from an incoherently radiating object and background light are focused onto a photosensitive mosaic, the currents from whose elements constitute the data on which is based a least-squares linear estimate of the radiance at points in the object. By comparison of the mean-square error with that given by Wiener filtering theory, the equivalent noise spectral density for use in the latter is shown to consist of a shot-noise term and a term due to the random fluctuations of the incoherent light; the former predominates under most circumstances. Turbulent distortion of the image after passage of the rays through a random-phase screen is also treated from this standpoint.

Helstrom, C. W.↗

Passive imaging through the turbulent atmosphere - Fundamental limits on the spatial frequency resolution of a rotational shearing interferometer

The signal-to-noise (S/N) ratio to be expected when a 180 deg rotationally shearing interferometer is used for image recovery at the diffraction limit of a large telescope is computed. The variance and covariance of the irradiance fluctuations at the detector array are shown to yield measures of the high-frequency spatial spectrum of the source. Four fundamental sources of noise are considered: temporal fluctuations of the source, space-time fluctuations of the atmosphere, shot noise in the detected photocurrents, and the effects of finite sampling. S/N is found to be directly proportional to the angular resolution of the telescope, the single-frame integration time, the square root of the number of frames, the cube of the operating wavelength, the quantum efficiency of the detector, and the average spectral irradiance from the source on the pupil. It is inversely proportional to the cube of the field angle subtended by the source (or part thereof) under study.

Burke, J. J.↗

Comparative Sensitivities of Gravitational Wave Detectors Based on Atom Interferometers and Light Interferometers

We consider a class of proposed gravitational wave detectors based on multiple atomic interferometers separated by large baselines and referenced by common laser systems. We compute the sensitivity limits of these detectors due to intrinsic phase noise of the light sources, non-inertial motion of the light sources, and atomic shot noise and compare them to sensitivity limits for traditional light interferometers. We find that atom interferometers and light interferometers are limited in a nearly identical way by intrinsic phase noise and that both require similar mitigation strategies (e.g. multiple arm instruments) to reach interesting sensitivities. The sensitivity limit from motion of the light sources is slightly different and favors the atom interferometers in the low-frequency limit, although the limit in both cases is severe. Whether this potential advantage outweighs the additional complexity associated with including atom interferometers will require further study.

Baker, John G.↗

Comparison of Atom Interferometers and Light Interferometers as Space-Based Gravitational Wave Detectors

We consider a class of proposed gravitational wave detectors based on multiple atomic interferometers separated by large baselines and referenced by common laser systems. We compute the sensitivity limits of these detectors due to intrinsic phase noise of the light sources, non-inertial motion of the light sources, and atomic shot noise and compare them to sensitivity limits for traditional light interferometers. We find that atom interferometers and light interferometers are limited in a nearly identical way by intrinsic phase noise and that both require similar mitigation strategies (e.g. multiple arm instruments) to reach interesting sensitivities. The sensitivity limit from motion of the light sources is slightly different and favors the atom interferometers in the low-frequency limit, although the limit in both cases is severe.

Baker, John G.↗

Surrogate Optimization for Quantum Circuits

Variational quantum Eigensolvers are touted as a near-term algorithm capable of impacting many applications. However, the potential has yet to be realized with few claims of quantum advantage and high resource estimates mainly due to the need for optimization in the presence of noise. Finding algorithms and methods to improve the convergence is essential to accelerate the capabilities of near-term hardware for VQE or more broad applications of hybrid methods in which optimization is required. To this goal we look to use modern approaches recently developed in circuit simulations and stochastic classical optimization that can be combined in a surrogate optimization approach to classical circuits. Using an approximate state vector simulator, we efficiently calculate an approximate Hessian, fed as an input for a detailed quantum circuit simulator. We demonstrate the capabilities of such an approach with and without sampling noise. We also show that this method outperforms Powell in the presence of quantum circuit shot noise by a factor of 2-4

quantum computing↗

Phase-Dependent Squeezing in Dual-Comb Interferometry

Manipulating the quantum noise of continuous-wave lasers through squeezing has reshaped optical interferometry. However, progress in optical frequency comb interferometry with pulsed squeezed sources has been limited, despite the role of frequency combs in ultraprecise optical metrology. Here, we introduce a new time-domain approach to characterizing squeezed femtosecond light pulses using dual-comb interferometry. Time-domain interferograms are generated via multiheterodyne beating between the modes of a Kerr soliton-squeezed frequency comb and a coherent state comb. The interferogram noise reveals phase-dependent squeezing and antisqueezing, dipping as much as 3.8 ± 0.2 dB below the shot noise level at alternating zero crossings. We model this nonstationary quantum noise as a periodic optical displacement of the squeezed comb by the coherent comb. These results support a route toward quantum-enhanced dual-comb timing applications and high-speed quantum state tomography with dual-comb interferometers.

Herman, Daniel Issac [University of Colorado, Boul↗

Real Time Quantitative 3-D Imaging of Diffusion Flame Species

A low-gravity environment, in space or ground-based facilities such as drop towers, provides a unique setting for study of combustion mechanisms. Understanding the physical phenomena controlling the ignition and spread of flames in microgravity has importance for space safety as well as better characterization of dynamical and chemical combustion processes which are normally masked by buoyancy and other gravity-related effects. Even the use of so-called 'limiting cases' or the construction of 1-D or 2-D models and experiments fail to make the analysis of combustion simultaneously simple and accurate. Ideally, to bridge the gap between chemistry and fluid mechanics in microgravity combustion, species concentrations and temperature profiles are needed throughout the flame. However, restrictions associated with performing measurements in reduced gravity, especially size and weight considerations, have generally limited microgravity combustion studies to the capture of flame emissions on film or video laser Schlieren imaging and (intrusive) temperature measurements using thermocouples. Given the development of detailed theoretical models, more sophisticated studies are needed to provide the kind of quantitative data necessary to characterize the properties of microgravity combustion processes as well as provide accurate feedback to improve the predictive capabilities of the computational models. While there have been a myriad of fluid mechanical visualization studies in microgravity combustion, little experimental work has been completed to obtain reactant and product concentrations within a microgravity flame. This is largely due to the fact that traditional sampling methods (quenching microprobes using GC and/or mass spec analysis) are too heavy, slow, and cumbersome for microgravity experiments. Non-intrusive optical spectroscopic techniques have - up until now - also required excessively bulky, power hungry equipment. However, with the advent of near-IR diode lasers, the possibility now exists to obtain reactant and product concentrations and temperatures non-intrusively in microgravity combustion studies. Over the past ten years, Southwest Sciences has focused its research on the high sensitivity, quantitative detection of gas phase species using diode lasers. Our research approach combines three innovations in an experimental system resulting in a new capability for nonintrusive measurement of major combustion species. FM spectroscopy or high frequency Wavelength Modulation Spectroscopy (WMS) have recently been applied to sensitive absorption measurements at Southwest Sciences and in other laboratories using GaAlAs or InGaAsP diode lasers in the visible or near-infrared as well as lead-salt lasers in the mid-infrared spectral region. Because these lasers exhibit essentially no source noise at the high detection frequencies employed with this technique, the achievement of sensitivity approaching the detector shot noise limit is possible.

Kane, Daniel J.↗

(55)Fe X-ray Response of HgCdTe NIR Detector Arrays

Conversion gain is a fundamental parameter in detector characteristics that is used to measure many identifying detector properties, including read noise, dark current, and quantum efficiency (QE). Charge coupling effects, such as inter-pixel capacitance, attenuate photon shot noise and result in an overestimation of of conversion gain when implementing the photon transfer technique. The (55)Fe X-ray technique is a direct and simple method by which to measure the conversion gain by comparing the observed instrumental counts (ADU) to the known charge (e-) liberated by a single X-ray photon. Here we present the calibrated pair production energy for 1.7 micron HgCdTe infrared detectors.

Fox, Ori↗

Squeezed light quantum imaging - experiment

This year, we focused on completing the light squeezing and building the imaging station. In this report, we present a detailed description of a quantum imaging experiment utilizing squeezed light. The entire experimental setup has two parts, namely, the squeezing station where we produce quantum-noise squeezed light where a light quadrature (either the amplitude of the phase) has reduced quantum error below the shot noise of coherent light, and the imaging station where the squeezed light is used to image an object. The squeezing station consists of an optical parametric oscillator operating below the laser threshold. We provide the status quo and the plans for the squeezing imaging experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The relationship of sensor parameters to applications data analysis

A stochastic model for the data acquisition system in a multispectral scanner system, like the one utilized by the LANDSAT satellites, is presented. A list of noise sources which are known or presumed to have a significant effect in the information extraction process was constructed. Since the shot noise introduced by the photodetectors in the sensor system is signal level dependent, an atmospheric model was adopted which could adequately describe the amount of radiation that gets into the sensors based on the atmospheric transmittance. An analysis was carried out to find the output spectral statistics in terms of the input signal statistics and the system parameters. This was integrated into a set of FORTRAN programs that when supplied with, the class statistics, the noise levels introduced by the sensor system, the atmospheric transmittance, and the atmospheric path radiance, can be used to estimate the classification performance. In order to show the beneficts of this model a series of runs were performed in which the Thematic Mapper multispectral scanner was the system under consideration.

Landgrebe, D. A.↗