Search NASA⌕ Search

SEARCH · Search NASA

Results for “size measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Ultra-Wideband Microwave Imaging System for Root Phenotyping

The roots are a vital organ for plant growth and health. The opaque surrounding environment of the roots and the complicated growth process means that in situ and non-destructive root phenotyping face great challenges, which thus spur great research interests. The existing methods for root phenotyping are either unable to provide high-precision and high accuracy in situ detection, or they change the surrounding root environment and are destructive to root growth and health. Thus,we propose and develop an ultra-wideband microwave scanning method that uses time reversal to achieve in situ root phenotyping nondestructively. To verify the method’s feasibility, we studied an electromagnetic numerical model that simulates the transmission signal of two ultra-wideband microwave antennas. The simulated signal of roots with different shapes shows the proposed system’s capability to measure the root size in the soil. Experimental validations were conducted considering three sets of measurements with different sizes, numbers and locations, and the experimental results indicate that the developed imaging system was able to differentiate root sizes and numbers with high contrast. The reconstruction from both simulations and experimental measurements provided accurate size estimation of the carrots in the soil, which indicates the system’s potential for root imaging.

59 BASIC BIOLOGICAL SCIENCES↗

Retrieval of the sea spray aerosol mode from submicron particle size distributions and supermicron scattering during LASIC

Abstract. Improved quantification of sea spray aerosol concentration and size is important for determining aerosol effects on clouds and the climate, though attempts to accurately capture the size distribution of the sea spray mode remain limited by the availability of supermicron size distributions. In this work, we introduce a new approach to retrieving lognormal mode fit parameters for a sea spray aerosol mode by combining submicron size distributions with supermicron scattering measurements using a Mie inversion. Submicron size distributions were measured by an ultra-high-sensitivity aerosol spectrometer (UHSAS), and supermicron scattering was taken as the difference between <10 µm and <1 µm three-wavelength integrating nephelometer measurements (NEPH). This UHSAS-NEPH method was applied during background marine periods of the Department of Energy Atmospheric Radiation Measurement Layered Atlantic Smoke Interactions with Clouds (LASIC) campaign on Ascension Island (November 2016–May 2017), when the contribution of sea spray aerosol was expected to represent a large fraction of the aerosol mass and total scattering. Lognormal sea spray modal parameters were retrieved from comparisons between nephelometer measurements and a lookup table of Mie theory-simulated scattering coefficients for low-error solutions that minimized the 0.4–1 µm residual in the UHSAS size distribution. We evaluated the UHSAS-NEPH method with a set of clean marine measurements in the North Atlantic that included supermicron size and chemical measurements, showing that measured supermicron size distributions are needed to constrain the sea spray number concentration but that mass concentration was reasonably characterized using supermicron scattering. For LASIC, the UHSAS-NEPH method retrieved sea spray mode properties for approximately 88 % of the background marine times when the scattering variability and total particle concentration were low (<± 5 Mm−1 and <400 cm−3, respectively), with mass mean diameter ranging from 0.6 to 1.9 µm (1.47 ± 0.17 µm), modal width ranging from 1.1 to 3.97 (2.4±0.3), and mass concentration ranging from 0.18 to 23.0 µg m−3 (8.37. ± 4.1 µg m−3). The measured nephelometer scattering at three wavelengths was found to constrain the mode width marginally at the largest particle sizes in the absence of additional size and chemical measurements for defining parameters for the Mie solutions. Comparing UHSAS-NEPH retrievals to those of a fitting algorithm applied only to the submicron UHSAS number size distribution showed that correlations between retrieved mass concentration and the available mass-based sea spray tracers (coarse scattering, wind speed, and chloride) are low when supermicron measurements are not considered. This work demonstrates the added value of supermicron scattering measurements for retrieving reasonable sea spray mass concentrations, providing the best-available observationally constrained estimate of the sea spray mode properties when supermicron size distribution measurements are not available.

54 ENVIRONMENTAL SCIENCES↗

Assessing the Potential Impact of Fugitive Methane Emissions on Offshore Platform Safety

One of the biggest risks to safety on offshore platform safety is the ignition of high-pressure natural gas streams. Currently, the size and number of fugitive emissions on offshore platforms is unknown and methods used to detect fugitives have significant shortcomings. To investigate the frequency, size, and potential impact of fugitives, a data collection exercise was conducted using incidents reported, leak survey data, and independent measurements. The size and number of fugitives on offshore facilities were simulated to investigate likely areas of safety concern. Incident reports indicate in 2021 there were 113 reports of gas leaks on 1119 offshore facilities, suggesting 0.02 fugitives per Type 1 facility (older, shallow-water platforms) and 0.31 fugitives per Type 2 facility (larger deeper-water facilities). Leak survey data report 12 fugitives per Type 1 facility (average emission 0.6 kg CH 4 h −1 leak −1 ) and 15 fugitives per Type 2 facility (average emission 1.5 kg CH 4 h −1 leak −1 ). Reconciliation of direct measurements with a bottom-up model suggests that the number of fugitive emissions generated from the leak report data is an underestimate for Type 1 platforms (44 fugitives facility −1 ; average emission 0.6 kg CH 4 h −1 leak −1 ) and in general agreement for the Type 2 platforms (15 fugitives facility −1 ; average emission 1.5 kg CH 4 h −1 leak −1 ). Analysis of the fugitive emission rates on an offshore platform suggests that gas will not collect to explosive concentration if any air movement is present (>0.36 mph); however, large volumes of air (~600 m 3 ) near representative leaks on the working deck could become explosive in hour-long zero-wind conditions. We suggest that wearable technology could be employed to indicate gas build up, safety regulations amended to consider low-wind conditions and real-world experiments are conducted to test assumptions of air mixing on the working deck.

explosion↗

The Ionization Profile Monitors in the Recycler Ring

The ionization profile monitors (IPMs) are used to measure the beam size in synchrotrons. Both the Fermilab Recycler and Main Injector (MI) machines have IPMs. However, they were not well understood enough to provide confidence in their measurements. Accurately measuring beam size through the IPMs was crucial to recognize the loss mechanisms for accelerators and to keep the beam loss to a minimum. Thus, performing measurements with different parameters using the IPMs led to a better analysis on how changes in conditions affect the beam size. The IPM measurements are compared with that of multi-wires in the upstream transfer line after applying corrections. The results were compared with other diagnostics and the change in the beam size for different parameters are presented in this paper.

43 PARTICLE ACCELERATORS↗

Rapidly tunable ultrabroadband flying focus using adaptive optics and an axiparabola

A programmable ultrabroadband flying focus was produced using adaptive optics and an axiparabola with a continuous wave superluminescent diode. A deformable mirror and spatial light modulator were used to add a programmable amount of radial group delay, and an axiparabola was used to create an extended focus by imparting spherical aberration. Three different flying focus trajectories were measured using spectral interferometry, two with uniform velocity and one with an accelerating velocity. Here, the temporal response function width of the flying focus optics alone was calculated to be 52 ± 6 fs, and the focal spot size was measured to be (1.2 ± 0.1) × larger than the diffraction-limited spot size through the extended focus.

Markland, H. S. [University of Rochester, NY (Unit↗

Seasonal variations in composition and sources of atmospheric ultrafine particles in urban Beijing based on near-continuous measurements

Abstract. Understanding the composition and sources of atmospheric ultrafine particles (UFPs) is essential in evaluating their exposure risks. It requires long-term measurements with high time resolution, which are scarce to date. We performed near-continuous measurements of UFP composition during four seasons in urban Beijing using a thermal desorption chemical ionization mass spectrometer, accompanied by real-time size distribution measurements. We found that UFPs in urban Beijing are dominated by organic components, varying seasonally from 68 % to 81 %. CHO organics (i.e., molecules containing carbon, hydrogen, and oxygen) are the most abundant in summer, while sulfur-containing organics, some nitrogen-containing organics, nitrate, and chloride are the most abundant in winter. With the increase of particle diameter, the contribution of CHO organics decreases, while that of sulfur-containing and nitrogen-containing organics, nitrate, and chloride increases. Source apportionment analysis of the UFP organics indicates contributions from cooking and vehicle sources, photooxidation sources enriched in CHO organics, and aqueous/heterogeneous sources enriched in nitrogen- and sulfur-containing organics. The increased contributions of cooking, vehicle, and photooxidation components are usually accompanied by simultaneous increases in UFP number concentrations related to cooking emission, vehicle emission, and new particle formation, respectively, while the increased contribution of the aqueous/heterogeneous composition is usually accompanied by the growth of UFP mode diameters. The highest UFP number concentrations in winter are due to the strongest new particle formation, the strongest local primary particle number emissions, and the slowest condensational growth of UFPs to larger sizes. This study provides a comprehensive understanding of urban UFP composition and sources and offers valuable datasets for the evaluation of UFP exposure risks.

54 ENVIRONMENTAL SCIENCES↗

Experimental Report: Multi-Instrument Comparison of AAF Size Distribution Instruments

Aerosols are particles suspended in the atmosphere, ranging in size from nanometers to micrometers. Their size distribution affects key atmospheric processes, including nucleation, coagulation, scavenging, activation, and radiative properties (Seinfeld and Pandis 2016). Aerosol size distribution is a critical parameter in atmospheric science, influencing processes such as cloud formation and radiative forcing. Accurate representation of aerosol size distributions is essential for understanding their impact on climate, air quality, and human health. However, aerosol size and composition vary significantly across time and space due to meteorological conditions and natural or anthropogenic sources. (Wu and Boor 2021). Various instruments are used to measure aerosol size distributions, each with distinct principles, advantages, and limitations. This report begins with an in-depth overview of aerosol size-distribution comparison studies, focusing on the passive cavity aerosol spectrometer probe (PCASP), portable optical particle spectrometer (POPS), ultra-high-sensitivity aerosol spectrometer (UHSAS), aerodynamic particle sizer (APS), and scanning mobility particle sizer (SMPS). All of these instruments are used by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), which commissioned this comparison and report. The report evaluates the strengths and weaknesses of these instruments, highlights their applications, and discusses efforts to merge data from multiple instruments for comprehensive analysis.

54 ENVIRONMENTAL SCIENCES↗

New Particle Formation and Growth to Climate-Relevant Aerosols at a Background Remote Site in the Western Himalaya

New particle formation (NPF) can influence the Earth’s radiative budget when the newly formed particles grow to climate-relevant sizes. Here, we present analysis of 21-months of continuous aerosol size distribution measurements at a background remote site in the western Himalaya and provide observational evidence that newly formed particles grow to cloud condensation nuclei (CCN)-active sizes (i.e. >20-100 nm in diameter). Out of total 55 NPF events, 38 (66%) events occurred in the pre-monsoon season (March-May). NPF events were classified into those with and without pollution influence as polluted and cleaner, respectively, using black carbon data. The analysis of air mass age, based on the ratio of number concentration of Aitken to accumulation mode aerosols, indicated that NPF occurred in the relatively cleaner air masses reaching to the site. The median formation rate of 10 nm particles and particle growth rates for cleaner events were three-fold and two-fold, respectively, higher than polluted events. We present the first estimates of the survival probability of newly formed particles to 50 nm and 100 nm size, which was not attempted in an Indian environment previously. The survival probability to 50 nm particles ranged from 44 to 98%, with a mean and standard deviation of 82 ± 18%. On average, ~60% of the particles surviving to 50 nm survived to 100 nm, making the overall survival probability of 100 nm to 53 ± 31%. This indicates that the probability of nucleated particles growing to CCN-active sizes under a large source of condensing vapor (transported from nearby lower-altitude regions) and low pre-existing particle concentrations (background mountain site) is high compared to the previous studies. These findings highlight the importance of the efficiency of nucleation events for producing CCN, which is a critical basis of aerosol indirect effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-speed volumetric two-photon fluorescence imaging of neurovascular dynamics

Abstract Understanding the structure and function of vasculature in the brain requires us to monitor distributed hemodynamics at high spatial and temporal resolution in three-dimensional (3D) volumes in vivo. Currently, a volumetric vasculature imaging method with sub-capillary spatial resolution and blood flow-resolving speed is lacking. Here, using two-photon laser scanning microscopy (TPLSM) with an axially extended Bessel focus, we capture volumetric hemodynamics in the awake mouse brain at a spatiotemporal resolution sufficient for measuring capillary size and blood flow. With Bessel TPLSM, the fluorescence signal of a vessel becomes proportional to its size, which enables convenient intensity-based analysis of vessel dilation and constriction dynamics in large volumes. We observe entrainment of vasodilation and vasoconstriction with pupil diameter and measure 3D blood flow at 99 volumes/second. Demonstrating high-throughput monitoring of hemodynamics in the awake brain, we expect Bessel TPLSM to make broad impacts on neurovasculature research.

59 BASIC BIOLOGICAL SCIENCES↗

Speckle contrast of interfering fluorescence X-rays

With the development of X-ray free-electron lasers (XFELs), producing pulses of femtosecond durations comparable with the coherence times of X-ray fluorescence, it has become possible to observe intensity–intensity correlations due to the interference of emission from independent atoms. This has been used to compare durations of X-ray pulses and to measure the size of a focused X-ray beam, for example. Here it is shown that it is also possible to observe the interference of fluorescence photons through the measurement of the speckle contrast of angle-resolved fluorescence patterns. Speckle contrast is often used as a measure of the degree of coherence of the incident beam or the fluctuations of the illuminated sample as determined from X-ray diffraction patterns formed by elastic scattering, rather than from fluorescence patterns as addressed here. Commonly used approaches to estimate speckle contrast were found to suffer when applied to XFEL-generated fluorescence patterns due to low photon counts and a significant variation of the excitation pulse energy from shot to shot. A new method to reliably estimate speckle contrast under such conditions, using a weighting scheme, is introduced. The method is demonstrated by comparing the speckle contrast of fluorescence observed with pulses of 3 fs to 15 fs duration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultra–fast, selective, non–melting, laser sintering of alumina with anisotropic and size–suppressed grains

In this paper, we report an ultra-fast sintering phenomenon of alumina achieved by the scanning laser irradiation method. Using CO 2 laser irradiation, we found that micrometer-sized alumina powder (d 50 = 1.2 µm) can be sintered close to full density within a few tens of seconds. The microstructure of laser-sintered alumina was different from that of the furnace-sintered alumina. The relative density and grain size of the laser-sintered alumina gradually decreased from the center of the laser beam to the edge. Anisotropy of the grain size was measured along and perpendicular to the scanning direction. This anisotropy decreased as the scanning speed decreased from 0.1 mm/s to 0.01 mm/s. The sintering master curve of grain size versus relative density, which reflects the sintering mechanism, was found to be affected by the laser scanning speed. When the laser scanning speed was 0.1 mm/s, grain size suppression was found for the almost fully dense alumina. However, at lower scanning speed (e.g., 0.01 mm/s), there was significant grain growth in the regions where the relative density was greater than 90%. Furthermore, these results clearly indicate that alumina can be sintered, in the solid-state, to a high density in a short time using scanning laser and the microstructure is different from the furnace-sintered alumina.

08 HYDROGEN↗

Diamagnetic Loop Testing on DARHT-I

Diamagnetic loops (DML) can be used as a noninvasive method for measurements of beam size in electron beam accelerators that use solenoidal magnetic transport. The loop fundamentally measures the magnetic flux excluded by a diamagnetic object. A comprehensive theory relates the rms beam radius to the excluded flux measured by the DML. We have built, and calibrated a DML apparatus. Recently, this DML has been used to measure the size of the electron beam near the final focus of the DARHT-I flash-radiography accelerator. Results are in agreement with beam transport code predictions. In this article, we review and summarize the construction, calibration, and electron-beam testing of this DML.

43 PARTICLE ACCELERATORS↗

Measuring and unbiasing the BAO shift in the Ly α forest with AbacusSummit

ABSTRACT The Dark Energy Spectroscopic Instrument (DESI) places sub- per cent constraints on measurements of the Baryon Acoustic Oscillation (BAO) scaling parameters from the Ly $\alpha$ forest. However, no systematic error budget stemming from non-linearities in the three-dimensional clustering of the Ly $\alpha$ forest is included in the DESI-Ly $\alpha$ analysis. In this work, we measure the size of the shift of the BAO peak using large Ly $\alpha$ forest mocks produced on the N-body simulation suite AbacusSummit, which adopt the Fluctuating–Gunn–Peterson Approximation (FGPA). Specifically, we measure the Ly $\alpha$ autocorrelation and the Ly $\alpha$-quasar cross-correlation functions. To mitigate the noise, we adopt a linear control variates technique, reducing the error bars by a factor of up to $\sim \sqrt{50}$ on large scales. From the autocorrelation, we detect a small positive shift in radial direction of $\Delta \alpha _{\parallel }= 0.35~{{\ \rm per\ cent}}$ at the 3$\sigma$ level and virtually no shift in the transverse direction, $\alpha _\perp$. From the cross-correlation, we see a similar shift to $\Delta \alpha _\parallel$, albeit with larger error bars, and a small negative shift, $\Delta \alpha _{\perp }=\sim$0.25 per cent, at the 2$\sigma$ level. We also make a connection with the Ly $\alpha$ forest effective field theory (EFT) framework and find that the one-loop EFT power spectrum yields unbiased measurements of the BAO shift parameters in radial and transverse direction for Ly $\alpha$ auto- and the Ly $\alpha$-quasar cross-correlation measurements. When using the one-loop EFT framework, we find that we can recover the BAO parameters without a shift, which has important implications for future Ly $\alpha$ forest analyses based on EFT. This work paves the way for novel full-shape analyses of the currently observing DESI and future surveys such as the PFS, WEAVE-QSO, and 4MOST.

Hadzhiyska, Boryana↗

Characterization of Orography-Influenced Riming and Secondary Ice Production and Their Effects on Precipitation Rates Using Radar Polarimetry and Doppler Spectra (CORSIPP-SAIL)

The Characterization of Orography-Influenced Riming and Secondary Ice Production and Their Effects on Precipitation Rates Using Radar Polarimetry and Doppler Spectra (CORSIPP) project was conducted to help improve the understanding of precipitation formation in orographically influenced terrain. Special focus is put on the two processes of riming and secondary ice production and their external drivers. Two instruments, a polarimetric W-band simultaneous transmission simultaneous reception (STSR) Doppler cloud radar manufactured by Radiometer Physics GmbH (RPG, instrument type RPG-FMCW-94-DP), from now on named LIMRAD94, and the video in situ snowfall sensor (VISSS), were deployed at the U. S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) site in Gothic, Colorado between November 2022 and June 2023 during the second SAIL winter. Note that the exact dates of data availability differ between the instruments. Both instruments arrived at Gothic on November 2, 2022, 09:20 local time. VISSS, described by Maahn et al., is equipped with two camera systems with telecentric lenses. The two cameras are at a 90° angle to each other. This configuration allows for size-independent measurements by capturing images of hydrometeors from two sides at a high frame rate of 250 Hz. With a minimum detection size of 200 μm, VISSS provides valuable insights into particle size, number, shape, complexity, and fall velocity. The VISSS was deployed on the grassland next to the ARM facility with the amazing help of the ARM employees on site. The setup started on November 2, 2022, and was finished on November 5, 2022, without major problems. VISSS measurements were started on November 6, 2022. LIMRAD94 was installed on a scaffolding platform near Orehouse (Gothic) on November 9, 2022, with the great help of RMBL staff. LIMRAD94 was mounted on a cold temperature scanner prototype. After a short test of the setup on November 9, 2022, the digital control of the scanner elevation stopped working for (at that time) unknown reasons. All attempts to resolve the problem failed. This malfunction made it impossible to operate LIMRAD94 in scanning mode. The scanner was then manually moved to zenith pointing mode and between November 10 and November 15, 2022, vertical observations for polarimetric calibration were performed. On November 15, 2022, after the polarimetric calibration was applied, the scanner was manually moved to 40° elevation with azimuthal view towards the Ka-band ARM Zenith Radar (KAZR) and measurements were continued at constant elevation. Investigation of the scanner malfunction on February 6, 2023, by Benn Schmatz revealed a disengagement between the cogwheel of the elevation motor and the cogwheel moving the scanner in elevation. This mechanical issue was temporarily solved by re-engaging the cogwheels. This made the scanner operational again for about four weeks, until mechanical force disengaged the cogwheels again on March 15, 2023. This repeated scanner failure remained undetected for about three weeks until April 8, 2023; during this time the scanner was stuck at 72° elevation. However, the radar software continued to produce data files falsely indicating that the scanner was still operational. After the scanner failure was noticed, scanning was stopped again, and we returned to constant elevation measurements. On May 15, 2023, the cogwheels of the elevation motor were secured with additional screws sent by the manufacturer. At some point in May, the cogwheels of the azimuth motor were also disengaged by mechanical force, which still allowed for range height indicator (RHI) but no plan position indicator (PPI) scans in the last weeks of the campaign. The azimuth motor was repaired in Germany after the end of the campaign. Throughout the campaign, RMBL and ARM staff kept the radar and the VISSS free of snow.

54 ENVIRONMENTAL SCIENCES↗

Droplet Evaporation-Based Approach for Microliter Fuel Property Measurements

Small-volume, high-throughput screening techniques are sought to enable downselection from a large candidate pool of bio-blendstocks to a select few, having physical properties consistent with requirements of downsized, turbo-boosted internal combustion engines. Herein, this work presents a droplet evaporation-based approach to predict heat of vaporization, vapor pressure, diffusion coefficient, and Lennard–Jones parameters for an unknown fuel. Two different schemes, considering the isothermal evaporation of a moving droplet in ambient air, are proposed, which combine droplet velocity and temperature measurements, with some known properties to predict unknown properties. The schemes utilize an inverse solution of a transient model of droplet evaporation solved in an iterative fashion. A baseline scheme, which only requires droplet size change measurements, is evaluated using test data for three liquid fuels, comprising of alkanes and alcohols, as obtained in a temperature-controlled chamber. Results yield temperature-dependent heat of vaporization and vapor pressure predictions within 10 % and 22 %, respectively, of reference values. The advanced scheme, which additionally requires droplet temperature measurement, is numerically evaluated in the current work and will be experimentally validated in future efforts. The advanced scheme is found to significantly improve prediction quality, with deviations less than 2 % and 1 % for heat of vaporization and vapor pressure, while also predicting diffusion coefficient and Lennard–Jones parameters within 5 % and 8 %, respectively. The combined set of approaches, which primarily track droplet evaporation, can be incorporated into a small-volume, high-throughput fuel screening process.

09 BIOMASS FUELS↗

Computer vision models and advanced TEM imaging for microstructures of irradiated AM316 stainless steels

Advancements were made in automating microscopy-based material characterization, particularly in studying irradiation effects on additively manufactured (AM) materials using machine learning (ML) and computer vision (CV). These automation efforts address the challenges of analyzing complex microstructures, accelerating the detection of irradiation-induced defects. Two CV models were developed at Argonne National Laboratory (ANL) to enhance transmission electron microscopy (TEM) analysis of irradiated AM 316 stainless steel. The first model focused on the detection of irradiation-induced dislocation loops, which contribute to material hardening and embrittlement. These loops, categorized as faulted or perfect, were automatically detected and classified using a Mask R-CNN model trained on TEM images from both in-situ and ex-situ ion irradiation experiments. The model achieved high accuracy, with precision, recall, and F1 scores of 0.839, 0.734, and 0.776, respectively, demonstrating its effectiveness in analyzing dislocation loops in irradiated AM materials. The second CV model was developed to analyze the size and wall thickness of dislocation cells in laser powder bed fusion (LPBF) 316 stainless steel. Using a U-Net++ architecture with EfficientNet as the encoder, the model was trained on TEM images to segment and measure cell size and wall thickness.

36 MATERIALS SCIENCE↗

Drop clustering and drop size correlations from holographic imagery suggest cloud droplet spectral broadening via entrainment-mixing

The question of how droplets rapidly grow large enough to initiate collision-coalescence has persisted for decades. Many theories explaining the production of sufficiently large drops (i.e., those in the “bottleneck” size range; ∼ 25–50 µm diameters) involve drop clustering on millimeter scales. A novel method is introduced to evaluate drop clustering trends particle-by-particle (i.e., the number/proximity of neighboring drops for given droplets; defined as drop clustering fields) which are diagnosed relative to drops within their shared drop environments – in contrast to previous studies which diagnose drop clustering of defined sample volumes, or in terms of absolute length scales. Specifically, this study evaluates the statistical likelihood that drops of a given size are associated with either a significant number of neighboring drops, or are significantly isolated from neighboring drops. Observations are acquired from the HOLODEC during the Cloud System Evolution in the Trades campaign, which sampled subtropical marine clouds. The HOLODEC measures drop size distributions and the 3D spatial coordinates of droplets. Results show drops within the bottleneck size range (diameters of ∼ 25–50 µm) are most likely to be significantly isolated from neighboring drops. This “isolated large drop trend” is primarily observed at subsaturated conditions, suggesting entrainment is the contributing factor. Holograms associated with this trend are more likely to have broader drop size distributions, larger maximum drop sizes and overly regions where precipitation reaches the lowest altitudes from the sampled cloud, suggesting entrainment-mixing drop size distribution broadening is a relevant precipitation-initiation mechanism.

D'Alessandro, John J. [Univ. of Washington, Seattl↗

Size Dependent Optical Properties and Structure of ZnS Nanocrystals Prepared from a Library of Thioureas

Here, ZnS nanocrystals (λ max (1S e -1S 3/2h ) = 260 - 320 nm, d = 1.7 - 10.0 nm) are synthesized from Zn(O 2 CR) 2 (O 2 CR = tetra-decanoate, oleate and 2-hexyldecanoate), N,N'-disubstituted and N,N',N'-trisubstituted thioureas, and P,P,N-trisubstituted phos-phanecarbothioamides. The influence of precursor substitution, ligand sterics, and reaction temperature on the final nanocrystal size were evaluated. By using saturated hydrocarbon solvents and saturated aliphatic carboxylate ligands, polymeric byproducts could be avoided and pure ZnS nanocrystals isolated. Elevated temperatures, slower precursor conversion reactivity and branched zinc 2-hexyldecanoate yield the largest ZnS nanocrystals. Carefully purified zinc carboxylate, rapidly converting precursors, and cooling the synthesis mixture following complete precursor conversion provide quasi spherical nanocrystals with the narrowest shape dispersity. Nanocrystal sizes were measured using pair distribution function (PDF) analysis of X-ray scattering and scanning transmission electron microscopy (STEM) and plotted versus the energy of their first excitonic optical absorption. The resulting empirical relationship provides a useful method to characterize the nanocrystal size from 1.7-4.0 nm using optical absorption spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗