Search NASA⌕ Search

SEARCH · Search NASA

Results for “slice sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Local and Total Density Measurements in Ice Shapes

Preliminary measurements of local and total densities inside ice shapes were obtained from ice shapes grown in the NASA Glenn Research Tunnel for a range of glaze ice, rime ice, and mixed phase ice conditions on a NACA 0012 airfoil at 0 angle of attack. The ice shapes were removed from the airfoil and a slice of ice 3 mm thick was obtained using a microtome. The resulting samples were then x-rayed to obtain a micro-radiography, the film was digitized, and image processing techniques were used to extract the local and total density values.

Vargas, Mario↗

Cosmic voids and void lensing in the Dark Energy Survey science verification data

Galaxies and their dark matter halos populate a complicated filamentary network around large, nearly empty regions known as cosmic voids. Cosmic voids are usually identified in spectroscopic galaxy surveys, where 3D information about the large-scale structure of the Universe is available. Although an increasing amount of photometric data is being produced, its potential for void studies is limited since photometric redshifts induce line-of-sight position errors of ~50 Mpc/h or more that can render many voids undetectable. In this paper we present a new void finder designed for photometric surveys, validate it using simulations, and apply it to the high-quality photo-z redMaGiC galaxy sample of the Dark Energy Survey Science Verification (DES-SV) data. The algorithm works by projecting galaxies into 2D slices and finding voids in the smoothed 2D galaxy density field of the slice. Fixing the line-of-sight size of the slices to be at least twice the photo- z scatter, the number of voids found in these projected slices of simulated spectroscopic and photometric galaxy catalogs is within 20% for all transverse void sizes, and indistinguishable for the largest voids of radius ~70 Mpc/h and larger. The positions, radii, and projected galaxy profiles of photometric voids also accurately match the spectroscopic void sample. Applying the algorithm to the DES-SV data in the redshift range 0.2 < z < 0.8 , we identify 87 voids with comoving radii spanning the range 18-120 Mpc/h, and carry out a stacked weak lensing measurement. With a significance of 4.4σ, the lensing measurement confirms the voids are truly underdense in the matter field and hence not a product of Poisson noise, tracer density effects or systematics in the data. In conclusion, it also demonstrates, for the first time in real data, the viability of void lensing studies in photometric surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultralow-Power Digital Correlator for Microwave Polarimetry

A recently developed high-speed digital correlator is especially well suited for processing readings of a passive microwave polarimeter. This circuit computes the autocorrelations of, and the cross-correlations among, data in four digital input streams representing samples of in-phase (I) and quadrature (Q) components of two intermediate-frequency (IF) signals, denoted A and B, that are generated in heterodyne reception of two microwave signals. The IF signals arriving at the correlator input terminals have been digitized to three levels (-1,0,1) at a sampling rate up to 500 MHz. Two bits (representing sign and magnitude) are needed to represent the instantaneous datum in each input channel; hence, eight bits are needed to represent the four input signals during any given cycle of the sampling clock. The accumulation (integration) time for the correlation is programmable in increments of 2(exp 8) cycles of the sampling clock, up to a maximum of 2(exp 24) cycles. The basic functionality of the correlator is embodied in 16 correlation slices, each of which contains identical logic circuits and counters (see figure). The first stage of each correlation slice is a logic gate that computes one of the desired correlations (for example, the autocorrelation of the I component of A or the negative of the cross-correlation of the I component of A and the Q component of B). The sampling of the output of the logic gate output is controlled by the sampling-clock signal, and an 8-bit counter increments in every clock cycle when the logic gate generates output. The most significant bit of the 8-bit counter is sampled by a 16-bit counter with a clock signal at 2(exp 8) the frequency of the sampling clock. The 16-bit counter is incremented every time the 8-bit counter rolls over.

Piepmeier, Jeffrey R.↗

Structure-factor amplitude reconstruction from serial femtosecond crystallography of two-dimensional membrane-protein crystals

Serial femtosecond crystallography of two-dimensional membrane-protein crystals at X-ray free-electron lasers has the potential to address the dynamics of functionally relevant large-scale motions, which can be sterically hindered in three-dimensional crystals and suppressed in cryocooled samples. In previous work, diffraction data limited to a two-dimensional reciprocal-space slice were evaluated and it was demonstrated that the low intensity of the diffraction signal can be overcome by collecting highly redundant data, thus enhancing the achievable resolution. Here, the application of a newly developed method to analyze diffraction data covering three reciprocal-space dimensions, extracting the reciprocal-space map of the structure-factor amplitudes, is presented. Despite the low resolution and completeness of the data set, it is shown by molecular replacement that the reconstructed amplitudes carry meaningful structural information. Therefore, it appears that these intrinsic limitations in resolution and completeness from two-dimensional crystal diffraction may be overcome by collecting highly redundant data along the three reciprocal-space axes, thus allowing the measurement of large-scale dynamics in pump–probe experiments.

59 BASIC BIOLOGICAL SCIENCES↗

Score-Based Physics-Informed Neural Networks for High-Dimensional Fokker–Planck Equations

The Fokker-Planck (FP) equation is a foundational partial differential equation (PDE) in stochastic processes involving Brownian motions. However, the curse of dimensionality (CoD) poses a formidable challenge when dealing with high-dimensional FP equations. Although Monte Carlo simulation and (vanilla) Physics-Informed Neural Networks (PINNs) have shown the potential to tackle CoD, both methods exhibit significant numerical errors in high dimensions when dealing with the probability density function (PDF) associated with Brownian motion. The point-wise PDF values tend to decrease exponentially as dimensionality increases, surpassing the precision of numerical simulations and resulting in substantial errors. In addition, due to its massive sampling, Monte Carlo fails to offer fast sampling. Modeling the logarithm likelihood (LL) via vanilla PINNs transforms the FP equation into a notoriously difficult Hamilton-Jacobi-Bellman (HJB) equation, which is impractical for PINN learning, whose error grows rapidly with dimension. To this end, we propose a novel approach utilizing a score-based solver to fit the score function in stochastic differential equations (SDEs). The score function, defined as the gradient of the LL, plays a fundamental role in inferring LL and PDF and enables fast SDE sampling, offering an effective means to overcome the CoD. Three fitting methods, Score Matching (SM), Sliced Score Matching (SSM), and Score-PINN, are introduced, each contributing unique advantages in computational complexity, accuracy, and generality. The proposed score-based SDE solver operates in two stages: first, employing score matching or Score-PINN to acquire the score function; and second, solving the LL via an ordinary differential equation (ODE) using the obtained score function. Comparative evaluations across these methods showcase varying trade-offs. The proposed methodology is evaluated across diverse SDEs, including anisotropic Ornstein-Uhlenbeck processes, geometric Brownian motion, and Brownian motion with varying eigenspace. We also test various distributions, including Gaussian, Log-normal, Laplace, and Cauchy distributions. The numerical results demonstrate the score-based SDE solver’s stability, speed, and performance across different experimental settings, solidifying its potential as a solution to CoD for high-dimensional FP equations.

97 MATHEMATICS AND COMPUTING↗

Energy Band Gap, Intrinsic Carrier Concentration and Fermi Level of CdTe Bulk Crystal between 304 K and 1067 K

Optical transmission measurements were performed on CdTe bulk single crystal. It was found that when a sliced and polished CdTe wafer was used, a white film started to develop when the sample was heated above 530 K and the sample became opaque. Therefore, a bulk crystal of CdTe was first grown in the window area by physical vapor transport; the optical transmission was then measured and from which the energy band gap was derived between 304 and 1067 K. The band gaps of CdTe can be fit well as a function of temperature using the Varshini expression: Eg (e V) = 1.5860 - 5.9117xl0(exp -4) T(sup 2)/(T + 160). Using the band gap data, the high temperature electron-hole equilibrium was calculated numerically by assuming the Kane's conduction band structure and a heavy-hole parabolic valance band. The calculated intrinsic carrier concentrations agree well with the experimental data reported previously. The calculated intrinsic Fermi levels between 270 and 1200 K were also presented.

Su, Ching-Hua↗

Generalized phase-space tomography for intense beams

Tomographic phase-space mapping in an intense particle beam is reviewed. The diagnostic is extended to beams with space-charge by assuming linear forces and is implemented using either solenoidal or quadrupole focusing lattices. The technique is benchmarked against self-consistent simulation and against a direct experimental sampling of phase-space using a pinhole scan. It is demonstrated that tomography can work for time-resolved phase-space mapping and slice emittance measurement. The technique is applied to a series of proof-of-principle tests conducted at the University of Maryland.

43 PARTICLE ACCELERATORS↗

Making Thin Sections from National Treasures: A Little Moon Rock Goes a Long Way

NASA’s Johnson Space Center curates the Apollo sample collection through their facilities in Houston, TX. It is a dual-purpose facility, intended both to store and preserve the precious samples, as well as to make them available for ongoing scientific study and public examination. The facilities consist of multiple vaults and lab spaces, including the Apollo Thin Section Lab. Although it is a part of the Curation facilities, this lab is intended to process specific lunar rock and dust samples into what are called “thin sections”. A thin section is a microscope slide with a very thin, highly polished slice of rock material mounted on it. These are used not only for microscope viewing, but also for a range of other sophisticated scientific instruments to map and measure fine details of the rock’s physical and chemical composition and structure. The process of making a thin section requires great care and patience and is an art in itself; each one is unique, and each sample can behave very differently while going through the same basic procedures. In general, it begins by taking a small chip of rock from a much larger sample. The rock fragment is placed within a small mold and liquid epoxy is poured over it and allowed to harden, producing what is called a “potted butt” (Figure 1). This is to stabilize the rock so that it won’t fragment or crumble during polishing, and to fill any cracks or voids within the rock. Once hardened, the epoxy on the bottom is carefully ground away to expose the rock surface within, which is then polished to a 1-micron finish. A thin new layer of fresh epoxy is then applied to the polished surface and used to mount it to a silica slide. Once the mounting epoxy has hardened, the potted butt is cut off less than one millimeter above the slide using a low-speed circular saw. This thin layer of sample material attached to the slide undergoes further grinding and polishing, typically bringing the sample thickness down to about 35 microns – roughly one third of the thickness of a human hair. The remaining potted butt is saved for future scientific investigations and can be re-polished and used again until all the rock material within it is used up. A single thin section can be reused countless times by numerous different researchers. In addition, thin sections are often exquisitely beautiful (Figure 2) and in some cases, lunar thin sections are used as public display samples, such as at the Smithsonian Air and Space Museum in Washington, DC. The production of thin sections allows an immense variety of research to be conducted on a tiny amount of rock or mineral material, allowing the bulk of the Apollo collection to stay pristine and unaltered, and thus, remain available for next generation of lunar scientists to further our insight into the Moon’s geological diversity, and to bring valuable new insights to our understanding of the origin of the Earth-Moon system.

J J Kent↗

Advances in constraining intrinsic alignment models with hydrodynamic simulations

We use galaxies from the illustristng, massiveblack-ii, and illustris-1 hydrodynamic simulations to investigate the behaviour of large scale galaxy intrinsic alignments. Our analysis spans four redshift slices over the approximate range of contemporary lensing surveys z = 0–1. We construct comparable weighted samples from the three simulations, which we then analyse using an alignment model that includes both linear and quadratic alignment contributions. Our data vector includes galaxy–galaxy, galaxy–shape, and shape–shape projected correlations, with the joint covariance matrix estimated analytically. In all of the simulations, we report non-zero IAs at the level of several σ. For a fixed lower mass threshold, we find a relatively strong redshift dependence in all three simulations, with the linear IA amplitude increasing by a factor of ~2 between redshifts z = 0 and z = 1. We report no significant evidence for non-zero values of the tidal torquing amplitude, A 2 , in TNG, above statistical uncertainties, although MBII favours a moderately negative A 2 ~ –2. Examining the properties of the TATT model as a function of colour, luminosity and galaxy type (satellite or central), our findings are consistent with the most recent measurements on real data. We also outline a novel method for constraining the TATT model parameters directly from the pixelized tidal field, alongside a proof-of-concept exercise using TNG. This technique is shown to be promising, although comparison with previous results obtained via other methods is non-trivial.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-AB-BRA-09: A Novel Method of Generating Ultrafast Volumetric Cine MRI (VC-MRI) Using Prior 4D-MRI and On-Board Phase-Skipped Encoding Acquisition for Radiotherapy Target Localization

Purpose: To develop a technique generating ultrafast on-board VC-MRI using prior 4D-MRI and on-board phase-skipped encoding k-space acquisition for real-time 3D target tracking of liver and lung radiotherapy. Methods: The end-of-expiration (EOE) volume in 4D-MRI acquired during the simulation was selected as the prior volume. 3 major respiratory deformation patterns were extracted through the principal component analysis of the deformation field maps (DFMs) generated between EOE and all other phases. The on-board VC-MRI at each instant was considered as a deformation of the prior volume, and the deformation was modeled as a linear combination of the extracted 3 major deformation patterns. To solve the weighting coefficients of the 3 major patterns, a 2D slice was extracted from VC-MRI volume to match with the 2D on-board sampling data, which was generated by 8-fold phase skipped-encoding k-space acquisition (i.e., sample 1 phase-encoding line out of every 8 lines) to achieve an ultrafast 16–24 volumes/s frame rate. The method was evaluated using XCAT digital phantom to simulate lung cancer patients. The 3D volume of end-ofinhalation (EOI) phase at the treatment day was used as ground-truth onboard VC-MRI with simulated changes in 1) breathing amplitude and 2) breathing amplitude/phase change from the simulation day. A liver cancer patient case was evaluated for in-vivo feasibility demonstration. Results: The comparison between ground truth and estimated on-board VC-MRI shows good agreements. In XCAT study with changed breathing amplitude, the volume-percent-difference(VPD) between ground-truth and estimated tumor volumes at EOI was 6.28% and the Center-of-Mass-Shift(COMS) was 0.82mm; with changed breathing amplitude and phase, the VPD was 8.50% and the COMS was 0.54mm. The study of liver patient case also demonstrated a promising in vivo feasibility of the proposed method Conclusion: Preliminary results suggest the feasibility to estimate ultrafast VC-MRI for on-board target localization with phase skipped-encoding k-space acquisition. Research grant from NIH R01-184173.

60 APPLIED LIFE SCIENCES↗

The distribution of galaxies within the 'Great Wall'

The galaxy distribution within the 'Great Wall', the most striking feature in the first three 'slices' of the CfA redshift survey extension is examined. The Great Wall is extracted from the sample and is analyzed by counting galaxies in cells. The 'local' two-point correlation function within the Great Wall is computed and the local correlation length, is estimated 15/h Mpc, about 3 times larger than the correlation length for the entire sample. The redshift distribution of galaxies in the pencil-beam survey by Broadhurst et al. (1990) shows peaks separated about by large 'voids', at least to a redshift of about 0.3. The peaks might represent the intersections of their about 5/h Mpc pencil beams with structures similar to the Great Wall. Under this hypothesis, sampling of the Great Walls shows that l approximately 12/h Mpc is the minimum projected beam size required to detect all the 'walls' at redshifts between the peak of the selection function and the effective depth of the survey.

Ramella, Massimo↗

Terahertz Computed Tomography of NASA Thermal Protection System Materials

A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

Roth, D. J.↗

Examination of Multiple Lithologies Within the Primitive Ordinary Chondrite NWA 5717

Northwest Africa 5717 is a primitive (subtype 3.05) ungrouped ordinary chondrite which contains two apparently distinct lithologies. In large cut meteorite slabs, the darker of these, lithology A, looks to host the second, much lighter in color, lithology B (upper left, Fig. 1). The nature of the boundary between the two is uncertain, ranging from abrupt to gradational and not always following particle boundaries. The distinction between the lithologies, beyond the obvious color differences, has been supported by a discrepancy in oxygen isotopes and an incongruity in the magnesium contents of chondrule olivine. Here, quantitative textural analysis and mineralogical methods have been used to investigate the two apparent lithologies within NWA 5717. Olivine grains contained in a thin section from NWA 7402, thought to be paired to 5717, were also measured to re-examine the distinct compositional range among the light and dark areas. Procedure: Particles from a high-resolution mosaic image of a roughly 13x15cm slice of NWA 5717 were traced in Adobe Photoshop. Due to the large size of the sample, visually representative regions of each lithology were chosen to be analyzed. The resulting layers of digitized particles were imported into ImageJ, which was used to measure their area, along with the axes, the angle from horizontal, and the centroid coordinates of ellipses fitted to each particle following the approach. Resulting 2D pixel areas were converted to spherical diameters employing the unfolding algorithm, which outputs a 3D particle size distribution based on digitized 2D size frequency data. Spatstat was used to create kernel density plots of the centroid coordinates for each region. X-ray compositional maps, microprobe analyses, and Mossbauer spectroscopy was conducted on a thin section of NWA 7402, tentatively paired to NWA 5717.

Cato, M. J.↗

A FLUX-LIMITED SAMPLE OF z {approx} 1 Ly{alpha} EMITTING GALAXIES IN THE CHANDRA DEEP FIELD SOUTH ,

We describe a method for obtaining a flux-limited sample of Ly{alpha} emitters from Galaxy Evolution Explorer (GALEX) grism data. We show that the multiple GALEX grism images can be converted into a three-dimensional (two spatial axes and one wavelength axis) data cube. The wavelength slices may then be treated as narrowband images and searched for emission-line galaxies. For the GALEX NUV grism data, the method provides a Ly{alpha} flux-limited sample over the redshift range z = 0.67-1.16. We test the method on the Chandra Deep Field South field, where we find 28 Ly{alpha} emitters with faint continuum magnitudes (NUV > 22) that are not present in the GALEX pipeline sample. We measure the completeness by adding artificial emitters and measuring the fraction recovered. We find that we have an 80% completeness above a Ly{alpha} flux of 10{sup -15} erg cm{sup -2} s{sup -1}. We use the UV spectra and the available X-ray data and optical spectra to estimate the fraction of active galactic nuclei in the selection. We report the first detection of a giant Ly{alpha} blob at z < 1, though we find that these objects are much less common at z = 1 than at z = 3. Finally, we compute limits on the z {approx} 1 Ly{alpha} luminosity function and confirm that there is a dramatic evolution in the luminosity function over the redshift range z = 0-1.

79 ASTRONOMY AND ASTROPHYSICS↗

The clustering of galaxies in the completed SDSS-III Baryon Oscillation Spectroscopic Survey: a tomographic measurement of structure growth and expansion rate from anisotropic galaxy clustering in Fourier space

In this study, we perform a tomographic structure growth and expansion rate analysis using the monopole, quadrupole and hexadecapole of the redshift-space galaxy power spectrum derived from the Sloan Digital Sky Survey (SDSS-III) Baryon Oscillation Spectroscopic Survey (BOSS) Data Release 12 combined sample, which covers the redshift range of 0.20 < $z$ < 0.75. By allowing for overlap between neighbouring redshift slices in order to extract information on the light-cone, we successfully obtain joint BAO and RSD constraints with a precision of 2-3 per cent for D A , 3-10 per cent for H and 9-12 per cent for fσ 8 with a redshift resolution of $Δz$ ~ 0.04. Our measurement is consistent with that presented in Wang et al., where the analysis is performed in configuration space. Finally, we apply our measurement to constrain the Em>f(R) gravity model, and find that the 95 per cent CL upper limit of log 10 B 0 can be reduced by 11 per cent by our tomographic BAO and RSD measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Cryo-STEM Tomography with Inpainting

Traditionally, microscopists have worked with the Nyquist-Shannon theory of sampling, which states that to be able to reconstruct the image fully it needs to be sampled at a rate of at least twice the highest spatial frequency in the image. This sampling rate assumes that the image is sampled at regular intervals and that every pixel contains information that is crucial for the image (it even assumes that noise is important). Images in general, and especially low dose S/TEM images, contain significantly less information than can be encoded by a grid of pixels (which is why image compression works). Mathematically speaking, the image data has a low dimensional or sparse representation. Through the application of compressive sensing methods [1,2,3] this representation can be found using pre-designed measurements that are usually random for implementation simplicity. These measurements and the compressive sensing reconstruction algorithms have the added benefit of reducing noise. This reconstruction approach can be extended into higher dimensions, whereby the random sampling in each 2-D image can be extended into: a sequence of tomographic projections (i.e. tilt images); a sequence of video frames (i.e. incorporating temporal resolution and dynamics); spectral resolution (i.e. energy filtering an image to see the distribution of elements); and ptychography (i.e. sampling a full diffraction image at each location in a 2-D grid across the sample). This approach has been employed experimentally for materials science samples requiring low-dose imaging [2], and can be readily applied to biological samples. Figure 1 shows the resolution possible in a complex biological system, mouse pancreatic islet beta cells [4], when tomogram slices are reconstructed using subsampling. Reducing the number of pixels (1/6 pix and 1/3*1/3) shows minimal degradation compared to the reconstructions using all pixels (all data and 1/3 tilt). Although subsampling 1/6 of the tilts (1/6 of overall dose) degrades the reconstruction to the point that the cellular structures cannot be identified. Using 1/3 of both the pixels and the tilts provides a high quality image at 1/9 the overall dose even for this most basic and rapid demonstration of the CS methods. Figure 2 demonstrates the theoretical tomogram reconstruction quality (vertical axis) as undersampling (horizontal axis) is increased; we examined subsampling pixels and tilt-angles individually and a combined approach in which both pixels and tilts are sub-sampled. Note that subsampling pixels maintains high quality reconstructions (solid lines). Using the inpainting algorithm to obtain tomograms can automatically reduce the dose applied to the system by an order of magnitude. Perhaps the best way to understand the impact is to consider that by using inpainting (and with minimal hardware changes), a sample that can normally withstand a dose of ~10 e/Å2 can potentially be imaged with an “equivalent quality” to a dose level of 103 e/Å2. To put this in perspective, this is approaching the dose level used for the most advanced images, in terms of spatial resolution, for inorganic systems. While there are issues for biological specimens beyond dose (structural complexity being the most important one), this sampling approach allows the methods that are traditionally used for materials science to be applied to biological systems [5]. References: [1] A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [2] L Kovarik, A Stevens, A Liyu et al. Appl. Phys. Lett. 109, 164102 (2016) [3] A Stevens, L Kovarik, P Abellan et al. Adv. Structural and Chemical Imaging 1(10), (2015), pp. 1. [4] MD Guay, W Czaja, MA Aronova et al. Scientific Reports 6, 27614 (2016) [5] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion Initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Stevens, Andrew↗

Resolution enhancement of lung 4D-CT via group-sparsity

Purpose: 4D-CT typically delivers more accurate information about anatomical structures in the lung, over 3D-CT, due to its ability to capture visual information of the lung motion across different respiratory phases. This helps to better determine the dose during radiation therapy for lung cancer. However, a critical concern with 4D-CT that substantially compromises this advantage is the low superior-inferior resolution due to less number of acquired slices, in order to control the CT radiation dose. To address this limitation, the authors propose an approach to reconstruct missing intermediate slices, so as to improve the superior-inferior resolution.Methods: In this method the authors exploit the observation that sampling information across respiratory phases in 4D-CT can be complimentary due to lung motion. The authors’ approach uses this locally complimentary information across phases in a patch-based sparse-representation framework. Moreover, unlike some recent approaches that treat local patches independently, the authors’ approach employs the group-sparsity framework that imposes neighborhood and similarity constraints between patches. This helps in mitigating the trade-off between noise robustness and structure preservation, which is an important consideration in resolution enhancement. The authors discuss the regularizing ability of group-sparsity, which helps in reducing the effect of noise and enables better structural localization and enhancement.Results: The authors perform extensive experiments on the publicly available DIR-Lab Lung 4D-CT dataset [R. Castillo, E. Castillo, R. Guerra, V. Johnson, T. McPhail, A. Garg, and T. Guerrero, “A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets,” Phys. Med. Biol. 54, 1849–1870 (2009)]. First, the authors carry out empirical parametric analysis of some important parameters in their approach. The authors then demonstrate, qualitatively as well as quantitatively, the ability of their approach to achieve more accurate and better localized results over bicubic interpolation as well as a related state-of-the-art approach. The authors also show results on some datasets with tumor, to further emphasize the clinical importance of their method.Conclusions: The authors have proposed to improve the superior-inferior resolution of 4D-CT by estimating intermediate slices. The authors’ approach exploits neighboring constraints in the group-sparsity framework, toward the goal of achieving better localization and noise robustness. The authors’ results are encouraging, and positively demonstrate the role of group-sparsity for 4D-CT resolution enhancement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transport and Retention of Particulate Organic Matter in Sand: Lab Experiments and Modelling

Flow-through reactor (FTR) experiments were conducted at three different downward vertical flow rates to study the transport and retention of particulate organic matter (Chlorella powder) in riverbed sediments. This data package includes data files (.csv) regarding effluent collected from the FTRs during the experiments (time, duration, volume of each sample collection; concentration of nonreactive bromide tracer; concentration of suspended Chlorella determined by absorbance measurements) and sediment (sand) slices collected from the FTRs after the experiments (mass of Chlorella retained in 1 cm depth intervals determined by loss-on-ignition method). More detailed descriptions of data are provided in the data dictionary, and detailed methods are available in the associated MSc thesis listed in ‘Related References.’ The data dictionary and file level meta data (FLMD) are included in the data package as both .csv and .xlsx files. This data package also includes timelapse videos (.mp4) of the experiments, and modelling scripts associated with the experiments. The modelling scripts are included as MATLAB ‘live scripts’ (.mlx, which can be run using MATLAB), and are also included as .pdf and .html files with output plots included (which can be viewed without a MATLAB license and installation). The data files and modelling scripts are organized into a .zip folder for each of the three FTR experiments (three flow rates).

54 ENVIRONMENTAL SCIENCES↗