Search NASA⌕ Search

SEARCH · Search NASA

Results for “snapping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

ExacTrac Snap Verification: A New Tool for Ensuring Quality Control for Lung Stereotactic Body Radiation Therapy

Purpose: The intrafraction verification provided by ExacTrac X-ray 6D Snap Verification (ET-SV) allows the tracking of potential isocenter displacements throughout patient position and treatment. The aims of this study were (1) to measure the intrafraction variations of the isocenter position (random errors); (2) to study the amplitude of the variation related to the fraction duration; and (3) to assess the impact of the table movement on positioning uncertainties. Methods and Materials: ET-SV uses images acquired before or during treatment delivery or both to detect isocenter displacement. Twenty patients treated with stereotactic body radiation therapy (SBRT) for lung tumors underwent SV before or during each beam. Noncoplanar beams were sometimes necessary. The time between the setup of the patient and each SV was noted, and values of deviations were compiled for 3 SV time groups: SV performed at {<=}10 min (group 1), between 11 and 20 min (group 2), and {>=}21 min (group 3). Random errors in positioning during the use of noncoplanar fields were noted. Results: The mean isocenter deviation {+-}SD was 2 {+-} 0.5 mm (range, 1-8 mm). The average deviations {+-}SD increased significantly from 1.6 {+-} 0.5 mm to 2.1 {+-} 0.8 mm and 2.2 {+-} 0.6 mm for groups 1, 2, and 3 (P=.002), respectively. Percentages of deviation {>=}3 mm were 7.06%, 22.83%, and 28.07% and 1.08%, 4.15%, and 8.4% for {>=}5 mm (P<.0001). For 11 patients, table rotation was necessary. The mean isocenter deviation {+-}SD increased significantly from 1.9 {+-} 0.5 mm before table rotation to 2.7 {+-} 0.5 mm (P=.001) for the first beam treated after rotation. Conclusions: SV detects isocenter deviations, which increase in amplitude and frequency with the fraction duration, and enables intrafraction verification for SBRT (taking into account clinical condition and technical issues). SV gives accurate targeting at any time during irradiation and may raise confidence to escalate the dose. SV appears to be an important tool for ensuring the quality control of SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design Challenges and Performance of Nested Neutron Mirrors for Microfocusing on SNAP

Kirkpatrick-Baez (KB) neutron supermirrors can efficiently focus polychromatic neutron beams to micrometre dimensions. The ultimate size is determined mainly by the perfection of the mirrors and by the size of the beam needed to have sufficient experimental signal. Nested or Montel KB mirrors can collect ~2.6 times more beam than standard sequential KB optics, but require good figure perfection at the edge of one mirror. This paper describes the characterization of the figure errors over the important reflective portions of the two mirrors needed for a Montel focusing pair. The measurements are placed in context with theoretical predictions and are used to predict mirror focusing performance. Strategies to improve on the focusing of this class of optics are suggested and early results from these mirrors installed on the Spallation Neutrons at Pressure (SNAP) Beamline 3 at the Spallation Neutron Source (SNS) at Oak Ridge are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNAP diffraction dataset for 2023 SMC data challenge

The data provided this challenge is ice under high pressure measured using the Spallation Neutrons and Pressure Diffractometer (SNAP) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The data is stored in a hdf5 file following the NeXus standard and can be read with tools built for either. While the NeXus format is self-describing, there is benefit to explaining some details. The data is stored in a single NXdata entry within a single NXentry. The NXdata has several fields denoting the 3-dimensional data (signal), the axes (D0 is the Qx axis, D1 is the Qy axis, and D2 is the Qz axis), and fields for the uncertainties and masking information. The data can be quickly viewed using the LoadMD algorithm and slice viewer in the Mantid workbench https://www.mantidproject.org.

36 MATERIALS SCIENCE↗

Mission Capabilities of Ion Engines Using SNAP-8 Power Supplies

Mission performance capabilities of ion engines powered by the 30 kw and 60 kw SNAP-8 power supplies are compared for the following missions: a 24-hr equatorial satellite, a 100 n mi lunar satellite, a 500 n mi Mars satellite, a Mercury probe, and an out-of-the-ecliptic probe. The capabilities of arc- jet engines and chemical engines for the same missions are compared with those of the ion engines. The majority of the comparisons are for 8500-lb spacecraft which are boosted into a 300 n mi orbit by the Atlas-Centaur. Variations in initial orbit altitude, the use of actual launch dates rather than dates based on simplifying assumptions, and the combined use of chemical and electrical propulsion systems were also evaluated in terms of their effect on mission performance.

IONIC PROPULSION↗

Electronic assembly rack panels snap on and off

Snap fasteners on each side of an electronic assembly rack blank panel give quick access to the interior. Guide pins extending from the inside face easily slip into standard screw holes on the frame and provide additional support.

Bailey, J. W.↗

Method for reducing snap in magnetic amplifiers

Method of reducing snap in magnetic amplifiers uses a degenerative feedback circuit consisting of a resistor and a separate winding on a magnetic core. The feedback circuit extends amplifier range by allowing it to be used at lower values of output current.

Fischer, R. L. E.↗