Search NASASearch

SEARCH · Search NASA

Results for “sodium source saving”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

234 records · Page 7

In situ electric field X-ray total scattering reveals composition-dependent electromechanical strain mechanisms in (1 − x )BiFe 2/8 Ti 3/8 Mg 3/8 O 3 – x PbTiO 3 ceramics

Ferroelectric materials find many applications in energy and aerospace industries. A major challenge for ferroelectric materials is maintaining their properties at elevated temperatures. The (1 − x )BiFe 2/8 Ti 3/8 Mg 3/8 O 3 – x PbTiO 3 (BFTM–xPT) ferroelectric solid solution is a promising candidate for high-temperature applications as it has a high piezoelectric response while also maintaining its ferroelectric phase until a high Curie temperature (T C ) of 650 °C. In this work, we investigate the piezoelectric mechanism in BFTM–xPT, a novel high-T C ferroelectric ceramic. To elucidate the origin of its enhanced piezoelectric performance, relative to other piezoceramics of similar T C , in situ electric field X-ray total scattering experiments were performed. Total scattering combines Bragg scattering (diffraction) and diffuse scattering (pair distribution function), providing insight on various length scales. With information spanning different length scales, extrinsic contributions (i.e., domain wall motion and interphase boundary motion) can be separated from intrinsic contributions (i.e., piezoelectric lattice strain). We show that, for compositions within the morphotropic phase boundary (MPB, x = 0.325), the piezoelectric response is dominated by intrinsic piezoelectric lattice strain, whereas outside the MPB (x = 0.375) the major component of the piezoelectric response is from extrinsic mechanisms including an electric-field-induced phase transition and tetragonal domain wall motion. This article reveals that the origin of piezoelectric response in BFTM–xPT is composition-dependent and shows that high-performance materials may also be located outside the MPB. These findings can help guide material design to optimize properties for specific applications.

Richtik, Brooke N. [University of Calgary, AB (Can

The active CGCG 077-102 NED02 galaxy within the Abell 2063 galaxy cluster

Context.Within the framework of investigating the link between the central super massive black holes in the cores of galaxies and the galaxies themselves, we detected a variable X-ray source in the center of CGCG 077-102 NED02, which is a member of the CGCG 077-102 galaxy pair within the Abell 2063 cluster of galaxies. Aims.Our goal is to combine X-ray and optical data to demonstrate that this object harbors an active super massive black hole in its core, and to relate this to the dynamical status of the galaxy pair within the Abell 2063 cluster. Methods.We usedChandraandXMM-Newtonarchival data to derive the X-ray spectral shape and variability. We also obtained optical spectroscopy to detect the expected emission lines that are typically found in active galactic nuclei. Finally, we used public ZTF imaging data to investigate the optical variability. Results.There is no evidence of multiple X-ray sources or extended components within CGCG 077-102 NED02. Single X-ray spectral models fit the source well. We detect significant, nonrandom inter-observation 0.5–10 keV X-ray flux variabilities, for observations separated by ∼4 days for short-term variations and by up to ∼700 days for long-term variations. Optical spectroscopy points toward a passive galaxy for CGCG 077-102 NED01 and a Seyfert for CGCG 077-102 NED02. The classification of CGCG 077-102 NED02 is also consistent with its X-ray luminosity of over 10 42 erg s −1 . We do not detect short-term variability in the optical ZTF light curves. However, we find a significant long-term stochastic variability in theg-band that can be well described by the damped random walk model with a best-fit characteristic damping timescale ofτ DRW = 30 −12 +28 days. Finally, the CGCG 077-102 galaxy pair is deeply embedded within the Abell 2063 potential, with a long enough history within this massive structure to have been affected by the influence of this cluster for a long time. Conclusions.Our observations point toward a moderately massive black hole in the center of CGCG 077-102 NED02 of ∼10 6 M ⊙ . As compared to another similar pair in the literature, CGCG 077-102 NED02 is not heavily obscured, perhaps because of the surrounding intracluster medium ram-pressure stripping.

Astronomy & Astrophysics

Nuclear Safety [Vol. 30, No. 3, July-September 1989]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 325 Safety of Framatome Advanced Nuclear Steam Supply Systems Designs by J. A. Charles and D. Lange, 333 Book Review of Nuclear Accidents: Intervention Levels for the Protection of the Public by H. B. Piper; ACCIDENT ANALYSIS: 335 Living PRA Computer Systems by S. C. Dinsmore and H.-P. Balfanz, 343 Summary of ICAP Assessments of RELAP5/MOD2 by W. E. Driskell and R. G. Hanson; CONTROL AND INSTRUMENTATION: 352 Thermal Performance Monitoring System at Maanshan Nuclear Power Plant by H.-J. Chao, Y.-P. Lin, G.-H. Jou, L.-Y. Liao, and Y.-B. Chen; DESIGN FEATURES: 358 Warning Systems for Nuclear Power Plant Emergencies by J. H. Sorensen and D. S. Mileti; WASTE AND SPENT FUEL MANAGEMENT: 371 Activities Related to Waste Management Compiled by E G. Silver; OPERATING EXPERIENCES: 382 Steam Generator Tube Performance: Experience with Water-Cooled Nuclear Power Reactors During 1985 by O. S. Tatone and R. L. Tapping, 400 Systems Interaction Analyses: Concepts and Techniques (Part II) by M. D. Muhlheim and G. A. Murphy, 413 Reactor Shutdown Experience Compiled by J. W. Cletcher, 416 Operating U.S. Power Reactors Compiled by E G. Silver; RECENT DEVELOPMENTS: 440 General Administrative Activities Compiled by E G. Silver, 460 Reports, Standards, and Safety Guides by D. S. Queener, 466 Status of Power-Reactor Licensing Activities Compiled by E G. Silver, 470 Proposed Rule Changes as of Mar. 31, 1989; ANNOUNCEMENTS: 334 Proceedings Published, 351 CEC Seminar on Methods and Codes for Assessing the Off-Site Consequences of Nuclear Accidents, 357 Short Course on Multiphase Flow and Heat Transfer: Bases and Applications in A: The Nuclear Power Industry B: The Process Industries, 357 International Conference on Probabilistic Safety Assessment and Management, 478 International Topical Meeting on the Safety, Status, and Future of Non-Commercial Reactors and Irradiation Facilities, 475 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Generalizable Web User Interface for Scalable and Streamlined Deployment of Building Energy Management Systems in Small and Medium-Sized Commercial Buildings

Small and medium-sized commercial buildings (SMCBs) comprise 94% of US commercial buildings yet face significant barriers to implementing building energy management systems despite advances in smart device technology. Existing solutions present critical limitations: cloud-based API solutions simplify deployment but create vendor lock-in constraints; commercial integrated software solutions ensure compatibility via standardized protocols but require substantial cost and technical expertise; open-source IoT platforms offer cost-effective vendor independence but provide insufficient standardized protocol support for commercial building automation. This research presents a generalizable web user interface framework that bridges the gap between evolving smart device capabilities and lagging software infrastructure for SMCBs. The proposed system integrates VOLTTRON open-source middleware with an automated configuration converter that transforms unified specifications written in YAML, a human-readable data-serialization format, into system-specific files, streamlining manual setup processes. The vendor-agnostic architecture supports industry-standard protocols (BACnet and Modbus) and semantic building models while providing adaptive web interfaces that dynamically adjust to various building configurations. Demonstrations through simulation-based testing and a field deployment show automatic interface adaptation across heterogeneous HVAC systems and multizone monitoring. The automated configuration converter also substantially reduces labor-intensive setup.

Chung, Jihoon [ORNL] (ORCID:0000000184880815)

The Intrinsic Sizes of Odd Radio Circles

Abstract A new class of sources, the so-called odd radio circles (ORCs), have been discovered by recent sensitive, large-area radio continuum surveys. The distances of these sources have so far relied on photometric redshifts of optical galaxies found at the centers of or near ORCs. Here we present Gemini rest-frame optical spectroscopy of six galaxies at the centers of, or potentially associated with, the first five ORC discoveries. We supplement this with Legacy Survey imaging and Prospector fits to theirgriz+W1/W2 photometry. Of the three ORCs with central galaxies, all lie at distances (z= 0.27–0.55) that confirm the large intrinsic diameters of the radio circles (300–500 kpc). The central galaxies are massive (M * ∼ 10 11 M ☉ ), red, unobscured ellipticals with old (≳1 Gyr) stellar populations. They have LINER spectral types that are shock-powered or active galactic nucleus (AGN)-powered. All three host low-luminosity, radio-quiet AGN. The similarity of their central galaxies is consistent with a common origin, perhaps as a blast wave from an ancient starburst. The other two ORCs are adjacent and have no prominent central galaxies. However, thez= 0.25 disk galaxy that lies between them hosts a Type 2, moderate-luminosity AGN. They may instead be the lobes of a radio jet from this AGN.

Astronomy & Astrophysics

Fusion Safety Program Peer Review (August 31 and September 1, 1999) [Slides]

The Fusion Safety Program Peer Review conference, held on August 31 and September 1, 1999, focuses on advancing the understanding and management of radioactive and hazardous materials within deuterium-tritium (D-T) fusion machines. The conference aims to investigate the behavior of significant sources of radioactive materials, such as activation products, dust, tritium, and beryllium. Additionally, it seeks to comprehend how various energy sources in fusion facilities—such as magnets, plasma, decay heat, and chemical reactions—can mobilize these materials. A key objective of the conference is to develop integrated, state-of-the-art analytic tools to demonstrate the safety and environmental potential of fusion technology. Furthermore, the conference assesses and evaluates safety and environmental issues associated with emerging fusion concepts, including those in the ARIES, ALPS, APEX, and IFE projects. This comprehensive approach aims to ensure the safe and sustainable advancement of fusion energy.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY

Study of wrap mode impact on Pseudomonas aeruginosa motion in the chemotactic field of fungi

An agent-based discrete computational model biologically calibrated to Pseudomonas aeruginosa migration is used to explore the impacts of bacterial reversals and wrap mode on the efficiency of motion in different environments, both with and without chemotaxis. It is first shown that wrap mode increases the exploration of continuous multimodal chemotactic profiles such as those produced by biologically relevant fungal networks. For cells undergoing a run-reverse pattern, it is shown that the bacteria are likely to remain at the first local chemoattractant maximal production site on a hypha they find. However, with wrap mode, the bacteria can more easily escape these local sites to further explore their neighboring environment along the fungi, suggesting that wrap mode may be beneficial for migration along the fungi in liquid. In a different set of simulations of bacterial motion close to an isolated chemotactic source, wrap mode is shown to increase the ability of a bacterium to reorient toward the source while reducing the overall motion required for similar chemotactic efficiency as a run-reverse strategy, suggesting a potential metabolic benefit. In contrast, model simulations show that wrap mode can increase the rate of dispersal of P. aeruginosa in a nonchemotactic environment.

Hansen, Austin [University of California, Riversid

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]

Field Validation of a Grid-Interactive Efficient Building Software Solution

The U.S. General Services Administration's (GSA's) Green Proving Ground (GPG) program, in partnership with the National Laboratory of the Rockies (NLR), completed a field study of a Grid-Interactive Efficient Buildings (GEB) software solution. The study focused on a single testbed facility to test the GEB functionality of the software solution, along with other features. The testbed facility - a courthouse - is a common building type in GSA's vast building portfolio, offering potentially impactful findings on a scalable level. The study evaluated Prescriptive Data's technology, Nantum OS, a connected building operating system ("GEB Solution") which aggregates multiple sources of previously siloed building data and combines that data with external sources, such as weather information or utility signals, into a single integrated platform. A GEB Solution is a type of Energy Management Information System (EMIS). EMIS is defined as a system of devices, data services, and software applications that communicates with any building system or third-party data source to aggregate and transform data into new capabilities to aid in the optimization of energy use at the building, campus, or agency level. This specific GEB Solution is an EMIS with ASO, automated system optimization, offering supervisory control of certain aspects of the Building Automation System (BAS). Multiple features were evaluated including, but not limited to, Continuous Demand Management to avoid setting new monthly kilowatt (kW) peaks, energy efficiency for reduction of kilowatt hours (kWh) and natural gas consumption, and automated demand response (ADR) for purposes of lowering demand during a utility called Demand Response (DR) event. The testbed facility was the Foley Federal Building and US Courthouse ("Foley Federal Building") located in Las Vegas, NV. This is a 209,496 sq. ft. building constructed in the 1960s with major renovations in 2004. The facility was a good candidate due to the large prevalence of office and courthouse spaces in the GSA portfolio of buildings. It also has many features which allow integration into and control of the building and a strong facilities team to assist with the study. Quantitative and qualitative performance objectives were developed using GSA's GPG GEB project template along with input from the vendor and building facility staff; these are outlined in Table 1. The quantitative performance objectives focused on continuous demand management, energy efficiency, and automated demand response. The qualitative performance objectives focused on the ease of installation and commissioning as well as the operability of the GEB solution. Other performance metrics that are reported on include carbon reduction, cost effectiveness, and occupant acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Tritium Betavoltaic Powered Sensor Platforms: Power Augmentation with Scintillating Particles

Betavoltaics (BV) are long-life power sources that typically convert beta particle radiation into electricity. Largely, the radioactive decays within the source go unharvested by the device. This work seeks to augment the power generation of BV devices by integration of scintillating particles within the radiative getter to convert beta emission which would otherwise not leave the getter into usable light for power generation. Silica-covered barium fluoride scintillating particles were integrated into a tritiated water getter. Power generation was increased from 100s of nW to µW levels with the addition of 0.2 wt. % particles into the getter. Nanowatt-scale sensor platforms were demonstrated with the µW BV devices and the maximum possible lifetime of such platforms was estimated. As this technique enables higher power density BV devices from conventional Si semiconductors (compared to wider bandgap BVs), the further implementation may lower the barrier-to-deployment of these long-life power/sensor platforms.

42 ENGINEERING

Three-dimensional dispersion in the type-II Dirac semimetals PtTe 2 and PdTe 2 revealed through circular dichroism in angle-resolved photoemission spectroscopy

PtTe 2 and PdTe 2 are among the first transition metal dichalcogenides that were predicted to host type-II Dirac fermions, exotic particles prohibited in free space. These materials are layered and air stable, which makes them top candidates for technological applications that take advantage of their anisotropic magnetotransport properties. Here, in this work, we provide a detailed characterization of the electronic structure of PtTe 2 and PdTe 2 using angle-resolved photoemission spectroscopy (ARPES) and density functional theory calculations, offering an alternative interpretation for one of the Dirac-like dispersions in these materials. Through the use of circularly polarized light, we report a different behavior of such dispersion in PdTe 2 compared to PtTe 2 , that we relate to a symmetry analysis of the dipole matrix element. Such analysis reveals a link between the observed circular dichroism and the different momentum-dependent terms in the dispersion of these two compounds, despite their close similarity in crystal structure. Additionally, our data show a clear difference in the circular dichroic signal for the type-II Dirac cones characteristic of these materials, compared to their topologically protected surface states. Our paper provides a useful reference for the ARPES characterization of other transition metal dichalcogenides with topological properties and illustrates the use of circular dichroism as a guide to identify the topological character and attributes of two otherwise equivalent band dispersions.

angle-resolved photoemission spectroscopy

An Automated Probabilistic Asteroid Prediscovery Pipeline

We present an automated and probabilistic method to make prediscovery detections of near-Earth asteroids (NEAs) in archival survey images, with the goal of reducing orbital uncertainty immediately after discovery. We refit the Minor Planet Center's astrometry and propagate the full six-parameter covariance to survey epochs to define search regions. We build low-threshold source catalogs for viable images and evaluate every detected source in a search region as a candidate prediscovery. We eliminate false positives by refitting a new orbit to each candidate and probabilistically linking detections across images using a likelihood ratio. Applied to the Zwicky Transient Facility's (ZTF) imaging, we identify approximately 3000 recently discovered NEAs with prediscovery potential, including a doubling of the observational arc for about 500. We use archival ZTF imaging to make prediscovery detections of the potentially hazardous asteroid 2021 DG1, extending its arc by 2.5 yr and reducing future apparition sky plane uncertainty from many degrees to arcseconds. We also recover 2025 FU24 nearly 7 yr before its first known observation, when its sky plane uncertainty covers hundreds of square degrees across thousands of ZTF images. The method is survey agnostic and scalable, enabling rapid orbit refinement for new discoveries from Rubin, NEO Surveyor, and NEOMIR.

79 ASTRONOMY AND ASTROPHYSICS

Sparse non-Markovian Noise Modeling of Transmon-Based Multi-Qubit Operations

The influence of noise on quantum dynamics is one of the main factors preventing current quantum processors from performing accurate quantum computations. Sufficient noise characterization and modeling can provide key insights into the effect of noise on quantum algorithms and inform the design of targeted error protection protocols. However, constructing effective noise models that are sparse in model parameters, yet predictive can be challenging. In this work, we present an approach for effective noise modeling of multi-qubit operations on transmon-based devices. Through a comprehensive characterization of seven devices offered by the IBM Quantum Platform, we show that the model can capture and predict a wide range of single- and two-qubit behaviors, including non-Markovian effects resulting from spatiotemporally correlated noise sources. The model’s predictive power is further highlighted through multi-qubit dynamical decoupling demonstrations and an implementation of the variational quantum eigensolver. As a training proxy for the hardware, we show that the model can predict expectation values within a relative error of 0.5%; this is a sevenfold improvement over default hardware noise models. Through these demonstrations, we highlight key error sources in superconducting qubits and illustrate the utility of reduced noise models for predicting hardware dynamics.

open quantum systems & decoherence

REDOTHERM (Redox Countercurrent Thermodynamic Limits Model) [SWR-24-88]

REDOTHERM is an open-source, MATLAB-based thermodynamic modeling framework developed to evaluate the performance of redox-active materials for water (H2O) and carbon dioxide (CO2) splitting. It includes models of all major unit operations and supports comparative analysis of different redox-active material candidates. The model is tailored for systems of moving oxide under a parallel/cocurrent flow (PF) and countercurrent flow (CF) configurations. Unvalidated mixed flow reactor (MFR, also known as CSTR) model is also included as an optional addition.

Lidor, Alon [National Renewable Energy Laboratory

Collision Tracking in OpenMC: Methods and Applications in Neutron Noise, Neutron Imaging, Time-of-Flight, and Multiplicity Counting

We present the development and application of a collision tracking feature within the OpenMC Monte Carlo particle transport code, designed for diverse applications such as neutron spectroscopy, scatter camera system, neutron noise, and multiplicity counting simulations. This feature enables the tracking of individual particle collisions, with potential applications in nuclear nonproliferation, reactor physics, and nuclear security. Additionally, the feature holds potential for the calibration of neutron detectors, specifically in converting light output into energy deposited within the detectors. The implementation consists of a set of filters—such as reaction type, energy, cell, and material—that constrain the set of collisions that are tracked, extensions to the Python API to enable simple input specification, and support for writing either OpenMC’s native HDF5-based format or the Monte Carlo particle list format. This feature was added to the official OpenMC release in version 0.15.3. In this work, the feature will be applied to showcase scenarios such as time-of-flight simulations, scatter-camera imaging for neutron source localization, neutron-noise analysis to extract integral kinetic parameters such as the prompt decay constant α, and multiplicity counting to estimate the mass of special nuclear materials. Ultimately, this feature aims to expand the application scope of open-source Monte Carlo particle transport codes such as OpenMC.

Monte Carlo code

Core Model Proposal #359: Hydrogen and Transportation Technology Update

This core model proposal updates modeling structures, key technology assumptions, and data sources for a detailed representation of hydrogen in GCAM’s energy system, including production, transmission and distribution, and consumption in hydrogen end-use sectors (buildings, transportation, industry).

08 HYDROGEN

Seasonal variation of the surface cross-shelf exchange in the northern South China Sea: a Lagrangian perspective

Previous studies on cross-shelf exchange, predominantly adopted an Eulerian perspective, struggled to identify water sources and pathways. Using a high-resolution regional ocean modeling system (ROMS) and Lagrangian particle tracking, this study systematically investigates the seasonal variation and dynamics of surface cross-shelf exchange in the northern South China Sea (NSCS) from a Lagrangian perspective. Based on daily released 30-day drifter trajectories we identify the key pathways, source regions for surface cross-shelf exchange, revealing pronounced seasonal variability. Results show the surface cross-shelf exchange generally following monsoon-driven Ekman transport. However, local dynamics, especially topographic modulation, can outweigh the expected Ekman-driven transport, producing surface exchange patterns opposite to that predicted from the prevailing winds. Topographic effects vary across different scales. In the coastal waters of western Guangdong during winter, despite downwelling-favorable winds, the modulation of alongshore currents by island topography induces an eastward pressure gradient. This gradient, through geostrophic balance, drives offshore flows opposite to wind-driven Ekman onshore transport. Furthermore, the eastern widened shelf exhibits a distinct seasonal variation of cross-shelf exchange, with strong offshore transport (opposite to the direction of Ekman transport) in winter and exceedingly weak exchange in summer. Analysis of the underlying mechanisms reveals that this winter offshore transport is primarily attributed to geostrophic flows driven by surface pressure gradient that is jointly modulated by the Kuroshio intrusion and local widened shelf topography, and enhanced by cumulative submesoscale processes. In summer, a persistent and strong along-isobath jet acts as a dynamic barrier, effectively suppressing the exchange. These findings highlight the important role of topography in regulating surface material transport, and have important implications for predicting the advection and dispersion of plankton or oil spills over the continental shelf influenced by monsoon.

Hao, Dongliang