Search NASA⌕ Search

SEARCH · Search NASA

Results for “soft errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Applying machine learning and quantum chemistry to predict the glass transition temperatures of polymers

Glass transition temperature (T g ) is important for understanding the physical and mechanical properties of a polymer material because it relates to the thermal energy required to transition between a hard glassy state and a soft rubbery one. Over the years, various models have been developed for predicting this thermal property from molecular structure to aid in designing novel polymers in selected classes. This work builds on those efforts by utilizing both machine learning (ML) and quantum chemistry (QC) techniques to develop models that can predict T g values from the molecular structure under different data availability scenarios and for a wide variety of polymer types. For the ML model, a graph convolutional network (GCN) was used to map topological polymer features; this model was trained against a dataset of more than 7500 T g values and resulted in a root mean square error (RMSE) of 38.1 °C. The QC-based regression model was trained on 83 T g values and produced an RMSE of 34.5 °C. In conclusion, this work demonstrated that while both model techniques produce accurate predictions and are suitable for different data availability scenarios, the QC-based regression model offered a more interpretable model framework with significantly less training data.

36 MATERIALS SCIENCE↗

Laboratory Data on the EUV/Soft-X-Ray Flux Problem of Fe XVIII and Fe XIX

Observations by the spacecraft Extreme Ultraviolet Explorer (EUVE), Far Ultraviolet Spectroscopic Explorer (FUSE), Chandra, and XMM-Newton of Capella (α Aurigae) have encountered problems with the relative intensities of the Fe XVIII and Fe XIX line emission in the soft-X-ray (XUV) and extreme-ultraviolet spectral ranges versus various model predictions based on theoretical atomic data. The reason may either lie in astrophysical phenomena, e.g., at emission or because of absorption by the interstellar medium, in the theoretical atomic data, in one or more spectrometer calibrations, or in the spectral modeling. Here, by measurements using an electron beam ion trap we provide laboratory data obtained under conditions that are reasonably close to stellar emission regions. The laboratory data on Fe XVIII and Fe XIX show line ratios that are rather similar to the observations of Capella. The measurements, therefore, rule out astrophysical phenomena and calibration errors and point to issues with the modeling of the observed Capella emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Effective field theory approach to heavy quark fragmentation

Using an approach based on Soft Collinear Effective Theory (SCET) and Heavy Quark Effective Theory (HQET) we determine the b-quark fragmentation function from electron-positron annihilation data at the Z-boson peak at next-to-next-to leading order with next-to-next-to leading log resummation of DGLAP logarithms, and next-to-next-to-next-to leading log resummation of endpoint logarithms. This analysis improves, by one order, the previous extraction of the b-quark fragmentation function. We find that while the addition of the next order in the calculation does not much shift the extracted form of the fragmentation function, it does reduce theoretical errors indicating that the expansion is converging. Using an approach based on effective field theory allows us to systematically control theoretical errors. Furthermore, while the fits of theory to data are generally good, the fits seem to be hinting that higher order correction from HQET may be needed to explain the b-quark fragmentation function at smaller values of momentum fraction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preoperative Pazopanib in High-Risk Soft Tissue Sarcoma: Phase II Window-of Opportunity Study of the German Interdisciplinary Sarcoma Group (NOPASS/GISG-04)

Background: Preoperative devascularization might improve local control and thus the outcome of patients with soft tissue sarcoma (STS). The multikinase inhibitor pazopanib has antiangiogenic effects and is approved for treating metastatic STS. We conducted a trial of preoperative pazopanib therapy in high-risk STS. Methods: This single-arm, phase II trial included patients with resectable, non-metastatic, treatment-naïve, high-risk STS. Patients received pazopanib 800 mg daily while waiting for surgery (21-day ‘window of opportunity’). The primary endpoint was metabolic response rate (MRR; proportion of patients with ≥ 50% reduction of mean standardized uptake value [SUV{sub mean}] in post- vs. pretreatment fluorodeoxyglucose–positron emission tomography/computed tomography [FDG-PET-CT]). Planned sample size was 35 patients (type I error, 5%; type II error, 20%). A translational substudy explored associations between response and concentration of circulating angiogenic factors. Results: Futility analysis was performed after 21 patients (11 female, mean age 67 years; liposarcoma n = 15); 17/21 patients were evaluable for the primary endpoint. The MRR was 1/17 (5.9%, 95% confidence interval < 0.01–0.29). Mean change in SUV{sub mean} of post- versus pretreatment PET was a 6% decrease (range 65% decrease to 34% increase); 7/21 (33.3%) patients had 12 grade 3/4 toxicities, and 19/21 (95.2%) patients were resected (all R0). One (4.8%) patient suffered a grade 4 postoperative complication (anastomotic leakage). Circulating endothelial progenitor cells, soluble vascular endothelial growth factor, and angiopoietin-2 concentrations showed no relevant changes during treatment. Conclusions: Although this study showed that preoperative pazopanib is not effective for unselected high-risk STS patients, relevant treatment effects were observed in a single patient. Future research needs to better define subgroups potentially benefiting from preoperative pazopanib treatment. ClinicalTrials.gov identifier: NCT01543802.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wave optics simulations for new soft x-ray beamlines at NSLS-II

In this work, we performed fully- and partially-coherent synchrotron emission and propagation simulations with the "Synchrotron Radiation Workshop" computer code to analyze the performance of two soft X-ray beamlines under development at the National Synchrotron Light Source II: Soft X-ray Nanoprobe (SXN), and Angle-Resolved Photoemission Spectroscopy (ARPES) and Resonant Inelastic X-ray Scattering (RIXS) Imaging (ARI). The SXN beamline intends to provide high flux and high spatial resolution coherent soft X-ray imaging capabilities using both zone plate and lensless coherent imaging techniques. The ARI beamline aims to perform high flux ARPES and RIXS experiments with a focal spot size at the sample approaching 100 nm using highly-demagnifying mirrors in Kirkpatrick-Baez geometry. To accurately calculate the resolution and the degree of X-ray coherence provided by the two state-of-the-art beamlines, partial coherence effects are required to be taken into account in wave optics simulations for these two beamlines. In this talk, beamline performance parameters such as spot size, degree of coherence, flux, and energy resolution at the sample are presented. The effects of mirror surface slope errors on beamline performance were studied and some suggestions for further optimization are discussed.

36 MATERIALS SCIENCE↗

Soft Coiled Pneumatic Actuator with Integrated Length-Sensing Function for Feedback Control

SPIRA Coil actuators are formed from thin sheets of PET plastic laminated into a coil shape that unfurls like a “party horn” when inflated, while many soft actuators require large pressures to create only modest strains, SPIRA Coils can easily be designed and fabricated to extend over dramatic distances with relatively low working pressures. Internal metalized PET strips separate in the extended portion of the actuator, creating an electrical circuit with a resistance that corresponds to the actuator length. This paper presents and experimentally validates easy-to-use design models for the actuators’ self-retracting spring stiffness, its pneumatic extension force, and its internal length-sensing electrical resistance. Testing of the self-sensing capabilities demonstrates that the embedded sensor can be used to determine the actuator length with virtually no hysteresis. Feedback control with the resistance-based sensing resulted in length-control errors within 5% of the extended actuator length (i.e., 3 cm of 60 cm).

Greenwood, Jacob R. (ORCID:0000000310897854)↗

Mechanical Design of a UHV Non-magnetic Kappa Diffractometer

A UHV non-magnetic kappa geometry diffractometer has been designed for the resonant soft X-ray scattering (RSXS) branch of the Intermediate Energy X-ray (IEX) beamline at the Advanced Photon Source (APS), Argonne National Laboratory. The kappa geometry allows for a large q-range and space for a sample environment (electric or magnetic fields). To avoid distorting the sample environment field, non-magnetic SmarAct, GmbH stages are used for the 4)-axis, X, Y, and Z linear stages. The ic and 0 axes are controlled by high-precision UHV compatible Physik Instrumente (PI) GmbH & Co. rotation stages. The design goal was to achieve a 50 gm sphere of confusion. To achieve this, iterative designs were developed using FEA and commercial stages were chosen that had minimal wobble, eccentricity, and flatness errors.

X-ray diffractometer↗

Automatic projection image registration for nanoscale X-ray tomographic reconstruction

Novel developments in X-ray sources, optics and detectors have significantly advanced the capability of X-ray microscopy at the nanoscale. Depending on the imaging modality and the photon energy, state-of-the-art X-ray microscopes are routinely operated at a spatial resolution of tens of nanometres for hard X-rays or ~ 10 nm for soft X-rays. The improvement in spatial resolution, however, has led to challenges in the tomographic reconstruction due to the fact that the imperfections of the mechanical system become clearly detectable in the projection images.Without proper registration of the projection images, a severe point spread function will be introduced into the tomographic reconstructions, causing the reduction of the three-dimensional (3D) spatial resolution as well as the enhancement of image artifacts. In this work, the development of a method that iteratively performs registration of the experimentally measured projection images to those that are numerically calculated by reprojecting the 3D matrix in the corresponding viewing angles is shown. Multiple algorithms are implemented to conduct the registration, which corrects the translational and/ or the rotational errors. A sequence that offers a superior performance is presented and discussed. Going beyond the visual assessment of the reconstruction results, the morphological quantification of a battery electrode particle that has gone through substantial cycling is investigated. The results show that the presented method has led to a better quality tomographic reconstruction, which, subsequently, promotes the fidelity in the quantification of the sample morphology.

42 ENGINEERING↗

Model-predictive optimal control of ferrofluidic microrobots in three-dimensional space

Ferrofluid microrobots have emerged as promising tools for minimally invasive medical procedures. Their unique properties to navigate complex fluids and reach otherwise inaccessible regions of the human body have enabled new applications in targeted drug delivery, tissue engineering, and diagnostics. Here, this paper proposes a model-predictive controller for the external magnetic manipulation of ferrofluid microrobots in three dimensions (3D). The internal optimization routine of the controller determines appropriate changes in the applied electromagnetic field to minimize the deviation between the actual and desired trajectories of the microrobot. A linear system governing locomotion is derived and used as the equality constraints of the optimization problems associated with the feedback index. In addition to ferrofluid droplets, the controller presented in this work may be applied to other magnetically-pulled microrobots. Several experiments are performed to validate the controller and showcase its ability to adapt to changes in system parameters such as the desired tracking trajectory and the size, orientation, deformation, and velocity of the microrobot. The accuracy of the controller is analyzed for each experiment, and the average error is found to be within 0.25 mm for small velocities. An additional experiment is performed to demonstrate significant improvement over a PID controller that is optimally tuned using Bayesian optimization. The results presented in this paper suggest that the proposed control algorithm could enable new microrobotic capabilities in minimally invasive medical procedures, lab-on-a-chip applications, and microfluidics.

60 APPLIED LIFE SCIENCES↗

Continuum radiated power density $(P^{\textrm{C}}_{\textrm{rad}})$ and effective charge $(Z_{\textrm{eff}})$ estimates from multi-energy photon-counting measurements

Multi-energy soft x-ray pinhole cameras have been designed, built, calibrated, and operated at Madison symmetric Torus, Alcator C-Mod, and more recently at Tokamak a configuration variable and Tungsten Environment in Steady-State Tokamak (WEST), to measure plasma emission across multiple energy ranges. Here we describe a new methodology to estimate the local continuum radiated power density and the plasma effective charge (Z eff ) directly from photon-counting measurements of the line-free continuum emission (Bremsstrahlung and Radiative Recombination) in several energy bands between 11 and 18 keV. This capability is particularly valuable for confinement systems using metal plasma-facing components, where x-ray losses from interactions with the sputtered wall can represent a significant fraction of the total radiated power (P rad ). The approach leverages a well-characterized detector responsivity, modeled by a complementary error function, and interprets the differential multi-energy measurements between adjacent energy levels through the probability density function of a Gaussian distribution. The implementation of this diagnostic technique is currently under development on the WEST tokamak, aiming at the goal of providing real-time P rad and Z eff measurements during long-pulse operation (up to 1000 s) in the 2026 campaign.

WEST↗

Detection of polarized gamma-ray emission from the Crab nebula with the Hitomi Soft Gamma-ray Detector

In this study, we present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray/gamma-ray sources on the sky, and the only source from which polarized X-ray photons have been detected. SGD observed the Crab nebula during the initial test observation phase of Hitomi. We performed data analysis of the SGD observation, SGD background estimation, and SGD Monte Carlo simulations, and successfully detected polarized gamma-ray emission from the Crab nebula with only about 5 ks exposure time. The obtained polarization fraction of the phase-integrated Crab emission (sum of pulsar and nebula emissions) is (22.1% ± 10.6%), and the polarization angle is 110°.7 +13°.2/-13°.0 in the energy range of 60–160 keV (the errors correspond to the 1 σ deviation). The confidence level of the polarization detection was 99.3%. The polarization angle measured by SGD is about one sigma deviation with the projected spin axis of the pulsar, 124° .0 ± 0° .1.

47 OTHER INSTRUMENTATION↗

Development of High Bs Fe-Ni Based Metal Amorphous Nanocomposite by Optimization of Glass Forming Ability

A growing interest in electric vehicles challenges soft magnetic materials to improve efficiency and power density. Metal amorphous nanocomposites (MANCs) have lower coercivities and eddy current losses, allowing for greater efficiency and higher switching frequency. The later allows for high motor speeds and improved power density. However, commercially available and laboratory demonstrated MANCs have shortcomings. Fe-based MANCs, such as FINEMET have excellent magnetic properties, but mechanical properties limit their application in high speed electric motors (HSMs). Fe-Co based MANCs, such as HITPERM, have high saturation inductions and good mechanical properties, but elevated magnetostrictive losses. Co-based MANCs and more recent Fe-Ni based MANCs have low losses and good mechanical properties, but lower saturation inductions (1-1.2 T), that limit power density in HSMs. Recently, much work has explored improving saturation induction in MANCs by increasing the content of magnetic elements, which comes at the cost of glass-forming ability (GFA). These efforts where generally limited to trial and error testing. Additionally, all work to date has focused on Fe-based alloys. In this work, a method of using Thermocalc simulation to locate near-eutectic compositions has been applied to Fe-Ni based alloys. Minima in liquidus temperature and solidification range were found for a ternary composition range and used to identify compositions that retain good GFA as the percentage of magnetic elements is increased. The (Fe 70 Ni 30 ) x (B-Si-Nb) 100-x alloy system for x=82% and x=85% was explored by Thermocalc simulations. This is an increase in magnetic element content compared to previously developed x=80% alloys. 3 compositions in the x=82% system, and 1 alloy in the x=85% system where identified and successfully cast as amorphous ribbon. The amorphous nature of the ribbon was confirmed by a bend test and XRD. Magnetic testing was performed by PPMS to measure saturation induction and Curie temperature of the amorphous material. The Curie temperatures increased to 407-438 °C for the x=82% alloys, and 462 °C for the x=85% alloy. Saturation induction increased to 1.28-1.36 T for the x=82% alloy and 1.48 T for the x=85% alloy, which is a significant improvement over the ~370 °C Curie temperature and 1.2 T saturation of previous Fe-Ni alloy. Crystallization behavior was studied by XRD for the x=85% alloy, showing that crystallization process follows a 2-step process of Amorphous → BCC+FCC+Amorphous → BCC+FCC+Fe 3 B+Fe 23 B 6 . Post annealing magnetic properties were studied by strip testing, and saturation induction as high as 1.48 T was seen after optimal annealing. TEM was used to study structure of as cast and annealed material. 2 alloys with x=82% compositions were identified with an optimal crystalline size of 10-20 nm, while the x=85% alloy had this structure in the as cast state. This opens the possibility of using the alloy in the as cast state, without requiring annealing. In conclusion, alloys with good GFA and improved magnetic properties were identified by Thermocalc simulation.

Krimer, Yuval↗

CAT: computer aided triage improving upon the Bayes risk through ε-refusal triage rules

Manual extraction of information from electronic pathology (epath) reports to populate the Surveillance, Epidemiology, and End Result (SEER) database is labor intensive. Systematizing the data extraction automatically using machine-learning (ML) and natural language processing (NLP) is desirable to reduce the human labor required to populate the SEER database and to improve the timeliness of the data. This enables scaling up registry efficiency and collection of new data elements. To ensure the integrity, quality, and continuity of the SEER data, the misclassification error of ML and NPL algorithms needs to be negligible. Current algorithms fail to achieve the precision of human experts who can bring additional information in their assessments. Differences in registry format and the desire to develop a common information extraction platform further complicate the ML/NLP tasks. The purpose of our study is to develop triage rules to partially automate registry workflow to improve the precision of the auto-extracted information. This paper presents a mathematical framework to improve the precision of a classifier beyond that of the Bayes classifier by selectively classifying item that are most likely to be correct. This results in a triage rule that only classifies a subset of the item. We characterize the optimal triage rule and demonstrate its usefulness in the problem of classifying cancer site from electronic pathology reports to achieve a desired precision. From the mathematical formalism, we propose a heuristic estimate for triage rule based on post-processing the soft-max output from standard machine learning algorithms. We show, in test cases, that the triage rule significantly improve the classification accuracy.

60 APPLIED LIFE SCIENCES↗

Implementation of a 1-2 keV point-projection x-ray spectrometer on the National Ignition Facility

A point-projection soft X-ray Opacity Spectrometer (OpSpec) has been implemented to measure X-ray spectra from ~1 to 2 keV on the National Ignition Facility (NIF). Measurement of such soft X-rays with open-aperture point-projection detectors is challenging because only very thin filters may be used to shield the detector from the hostile environment. OpSpec diffracts X-rays from 540 to 2100 eV off a potassium (or rubidium) acid phthalate (KAP or RbAP) crystal onto either image plates or, most recently, X-ray films. A “sacrificial front filter” strategy is used to prevent crystal damage, while 2 or 3 rear filters protect the data. Since May 2017, OpSpec has been recording X-ray transmission data for iron-magnesium plasmas on the NIF, at “Anchor 1” plasma conditions (temperature ~150 eV, density ~7 × 10 21 e - /cm 3 ). Upgrades improved OpSpec’s performance on 6 NIF shots in August and December 2017, with reduced backgrounds and 100% data return using filter stacks as thin as 2.9 μm (total). We conclude that photometric noise is beginning to meet requirements, and further work will reduce systematic errors.

47 OTHER INSTRUMENTATION↗

Development of Steady-State and Dynamic Mass and Energy Constrained Neural Networks for Distributed Chemical Systems Using Noisy Transient Data

The paper presents the development of algorithms for mass and energy constrained neural network models that can exactly conserve the overall mass and energy of distributed chemical process systems, even though the noisy transient data used for optimal model training violate the same. In contrast to approximately satisfying mass and energy balance constraints of a system by soft penalization of objective function, algorithms have been developed for solving equality-constrained nonlinear optimization problems, thus providing the guarantee of exactly satisfying the system mass and energy conservation laws. For developing dynamic mass-energy constrained network models for distributed systems, hybrid series and parallel dynamic-static neural networks have been leveraged. The developed algorithms for solving both the training and forward problems are validated using both steady-state and dynamic data in the presence of various noise characteristics. The developed data-driven algorithms are flexible to exactly satisfy mass and energy balance constraints for dynamic chemical processes if the system holdup information is available. The proposed network structures and algorithms are applied to the development of data-driven lumped and distributed models of an adiabatic superheater/reheater system, a nonisothermal continuous stirred tank reactor, as well as an electrically heated plug-flow reactor system where one form of energy gets transformed to another. It has been observed that the mass-energy constrained neural networks yield a root mean squared error of <1% with respect to the system truth for the case studies evaluated in this work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing correlated truncation errors in modern nucleon-nucleon potentials

We test the BUQEYE model of correlated effective field theory (EFT) truncation errors on Reinert, Krebs, and Epelbaum's semilocal momentum-space implementation of the chiral EFT (𝜒⁢EFT ) expansion of the nucleon-nucleon (NN) potential. This Bayesian model hypothesizes that dimensionless coefficient functions extracted from the order-by-order corrections to NN observables can be treated as draws from a Gaussian process (GP). We combine a variety of graphical and statistical diagnostics to assess when predicted observables have a 𝜒⁢EFT convergence pattern consistent with the hypothesized GP statistical model. Our conclusions are that, first, the BUQEYE model is generally applicable to the potential investigated here, which enables statistically principled estimates of the impact of higher EFT orders on observables. Second, parameters defining the extracted coefficients such as the expansion parameter 𝑄 must be well chosen for the coefficients to exhibit a regular convergence pattern—a property we exploit to obtain posterior distributions for such quantities. Third, the assumption of GP stationarity across lab energy and scattering angle is not generally met; this necessitates adjustments in future work. We provide a workflow and interpretive guide for our analysis framework, and show what can be inferred about probability distributions for 𝑄, the EFT breakdown scale Λ 𝑏 , the scale associated with soft physics in the 𝜒⁢EFT potential 𝑚 eff , and the GP hyperparameters. All our results can be reproduced using a publicly available Jupyter notebook, which can be straightforwardly modified to analyze other 𝜒⁢EFT NN potentials.

Bayesian methods↗

Tensile Modeling PVC Gels for Electrohydraulic Actuators

Polyvinyl chloride (PVC)-dibutyl adipate (DBA) gels are a fascinating dielectric elastomer actuator showing promise in soft robotics. When actuated with high voltages, the gel deforms towards the anode. A recent application of PVC gels in electrohydraulic actuators motivates elastic and hyperelastic constitutive relationships for tensile loading modes. PVC gels with plasticizer-to-polymer weight ratios of 2:1, 4:1, 6:1, and 8:1 w/w were evaluated. PVC gels exhibit a linear elastic region up to 25% strain. The elastic modulus decreased with increasing plasticizer content from 288.8 kPa, 56.1 kPa, 24.7 kPa, to 11 kPa. Poisson’s ratio also decreased with increasing plasticizer content from 0.42, 0.43, 0.39, to 0.35. We suggest that the decrease in polymer concentration facilitates a weakly interconnected polymer network susceptible to chain slippage that hinders the network response, thus lowering Poisson’s ratio. Our work suggests that PVC gels can be treated as isotropic and incompressible for large strains and hyperelastic modeling; however, highly plasticized gels tend to act less incompressible at small strains. The power scaling law between the elastic modulus and plasticizer weight ratio showed high agreement, making the elastic modulus deterministic for any plasticizer content. The Neo–Hookean, Mooney–Rivlin, Yeoh, Gent, Ogden, and extended tube hyperelastic constitutive models are investigated. The Yeoh model shows the highest feasibility when evaluated up to 3.5 stretch, showing a maximum normalized root-mean-square-error of 6.85%. Together, these findings establish a constitutive basis for PVC-DBA gels, incorporating small strain elasticity, large strain non-linear behavior, and network analysis while providing suggestive insight into the network structure required for accurately modeling the EPIC.

Polymer Science↗

Silver clusters tune up electronic properties of graphene nanoflakes: A comprehensive theoretical study

Graphene-silver composites reflect a synergic effect of both components with enhanced electronic, adsorption and catalytic properties. We introduce here the detailed theoretical study on geometric, thermodynamic and electronic properties of silver clusters Ag n (n=2–10) adsorbed on graphene nanoflakes as a model for silver-graphene composites. First, a benchmark study is performed on Ag n …coronene complexes (n=2, 4) by evaluating various functional against reported high level ab-initio method for the selection of best functional for further calculations. Then, density functional theory study at the best chosen level is performed to inquire how clustering of adsorbate attached with carbon surface can impact geometric, electronic and thermodynamic properties of silver-graphene composites. Furthermore, the interaction energies are corrected for dispersion and basis set superposition error in order to get more realistic estimate of interaction energies. In progression, we investigated the dependence of interaction energy upon cluster size and dimensionality. For Ag n …coronene, the binding energies increase monotonically as the number of atoms in the cluster increases. However, for Ag n …dodecabenzocoronene, the interaction energies show a sudden drop at Ag 7 …dodecabenzocoronene. The difference in behavior between Ag n …dodecabenzocoronene and Ag n …coronene for interaction energy is attributed to edge effect present in coronene. Furthermore, coplanar orientations of the silver clusters on polyaromatic hydrocarbons have higher interaction energies. The 2D-3D transition of the silver cluster is observed for Ag 7 …coronene. CDA analysis reveals that backdonation from dodecabenzocoronene to silver clusters is more dominant in Ag 4 –Ag 7 whereas other clusters have dominant charge transfer to dodecabenzocoronene. Charge transfer analysis via constrained density functional theory (CDFT) reveals significant energy lowering from charge donor-acceptor interactions. Further energy decomposition analysis (EDA) using absolutely-localized molecular orbitals (ALMO) suggests that, while charge-transfer is important in these systems, the sum of electrostatics, Pauli repulsion, and London dispersion are far more significant as silver cluster size increases. NCI results also support the presence of van der Waals and electrostatic interactions. The hollow top is most favorite interaction sites compared to bridge top and head top binding sites over coronene lattice. The ionization potential, electron affinity, frontier molecular orbital analysis, chemical hardness, softness, chemical potential, and Fermi levels are deliberated to verify the stability and reactivity of most stable silver-graphene composites. The remarkable outcome of the current findings makes our silver-graphene composite as a potential applicant for high performance electronic and catalytic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗