Search NASA⌕ Search

SEARCH · Search NASA

Results for “software size estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Statistical Modeling of Landscape Pattern and the Effects of Coarse Spatial Resolution

Analysis of classified satellite imagery was conducted to characterize errors in estimates of area based on coarse resolution satellite imagery which are due to distortions in sizes of small fragments, and to explore the feasibility of correcting for these errors using a statistical modeling approach. Sizes of bodies of open water on European Remote-Sensing (ERS-1) synthetic aperture radar (SAR) and fire scars on Landsat Multispectral Scanner (MSS) imagery were measured using geographic information system (GIS) software. Statistical analysis of the smaller scars and ponds as observed with this imagery of relatively fine resolution demonstrated that the distribution of the sizes could be modeled by either of two types of statistical distributions-a power distribution related to fractal processes or a simple exponential distribution. A comparison of the size distribution of small burn scars as observed with Landsat with the distribution observed with the much coarser Advanced Very High Resolution Radiometer (AVHRR) imagery revealed effects of coarse resolution, each of which were associated with a particular size range, and whose net effect accounted for the bias in total burn area due to coarse spatial resolution. Size dependent area correction procedures are therefore feasible. A statistical modeling approach to area estimation, based models of the underlying and observed size distributions of fragments in the scene, may lead to a procedure which requires little or no ancillary data.

Hlavka, C. A.↗

Updates on the Debrisat Hypervelocity Experiment and Characterization of Fragments in Support of Environmental Models

To develop, maintain, and update orbital debris environmental and break-up models, such as the NASA Orbital Debris Engineering Model (ORDEM) and the NASA Standard Satellite Breakup Model (SSBM), the NASA Orbital Debris Program Office (ODPO) relies on the most recent validated datasets from various measurement sources, both laboratory and environmental. One key project that will provide insight for break-up events using modern-day spacecraft materials and construction techniques is the DebriSat laboratory hypervelocity-impact test. Based on the mass of the target, the projectile, and the impact velocity, the expected number of fragments greater than 2 mm, generated using the NASA SSBM, was estimated to be close to 85,000. To date, the DebriSat fragment database continues to grow, with over 200,000 fragments collected that will help inform updates to the SSBM. Additionally, the growing fragment ensemble will support key parameters for the next release of NASA’s environmental models, employing fragment shapes, densities, and size distributions. To further support these environmental models, specifically the size parameter used in ground-based optical measurements, optical characterization on a subset of DebriSat fragments is being conducted in ODPO’s Optical Measurement Center (OMC). Broadband bidirectional reflectance distribution (BRDF) measurements will provide insight into the optical-based NASA Size Estimation Model (OSEM). The OSEM equates an object’s brightness to size (e.g., diameter of a disk or sphere) given several assumed parameters, including a defined phase function, albedo, and range. To address the first defined parameter, the ODPO has been using ray-tracing software to simulate light conditions in the OMC and to generate phase functions (i.e., specular, Lambertian, and experimentally-derived) of known shapes, materials, and sizes. This simulated data, in addition to the experimentally derived measurements collected in the OMC, will aid in determining whether a new phase function would be suitable for an updated OSEM. The OSEM also assumes a single-value albedo, thus pre-impact spectral measurements on a subset of DebriSat materials were acquired for baseline material characterization and to provide insight into spacecraft material taxonomies. This DebriSat spectral data, along with spectral measurements from other known spacecraft material samples, will allow for better analyses of albedo variations and the effect on size calculations of defined laboratory targets, thus further supporting OSEM updates. This paper provides an overview of DebriSat, the status of the project, updates on the parameter distributions, an overview of the NASA SSBM, and ongoing fragment characterization efforts within the OMC.

Heather Cowardin↗

Updates on the DebriSat Hypervelocity Experiment and Characterization of Fragments in Support of Environmental Models

To develop, maintain, and update orbital debris environmental and break-up models, such as the NASA Orbital Debris Engineering Model (ORDEM) and the NASA Standard Satellite Breakup Model (SSBM), the NASA Orbital Debris Program Office (ODPO) relies on the most recent validated datasets from various measurement sources, both laboratory and environmental. One key project that will provide insight for break-up events using modern-day spacecraft materials and construction techniques is the DebriSat laboratory hypervelocity-impact test. Based on the mass of the target, the projectile, and the impact velocity, the expected number of fragments greater than 2 mm, generated using the NASA SSBM, was estimated to be close to 85,000. To date, the DebriSat fragment database continues to grow, with over 200,000 fragments collected that will help inform updates to the SSBM. Additionally, the growing fragment ensemble will support key parameters for the next release of NASA’s environmental models, employing fragment shapes, densities, and size distributions. To further support these environmental models, specifically the size parameter used in ground-based optical measurements, optical characterization on a subset of DebriSat fragments is being conducted in ODPO’s Optical Measurement Center (OMC). Broadband bidirectional reflectance distribution (BRDF) measurements will provide insight into the optical-based NASA Size Estimation Model (OSEM). The OSEM equates an object’s brightness to size (e.g., diameter of a disk or sphere) given several assumed parameters, including a defined phase function, albedo, and range. To address the first defined parameter, the ODPO has been using ray-tracing software to simulate light conditions in the OMC and to generate phase functions (i.e., specular, Lambertian, and experimentally-derived) of known shapes, materials, and sizes. This simulated data, in addition to the experimentally derived measurements collected in the OMC, will aid in determining whether a new phase function would be suitable for an updated OSEM. The OSEM also assumes a single-value albedo, thus preimpact spectral measurements on a subset of DebriSat materials were acquired for baseline material characterization and to provide insight into spacecraft material taxonomies. This DebriSat spectral data, along with spectral measurements from other known spacecraft material samples, will allow for better analyses of albedo variations and the effect on size calculations of defined laboratory targets, thus further supporting OSEM updates. This paper provides an overview of DebriSat, the status of the project, updates on the parameter distributions, an overview of the NASA SSBM, and ongoing fragment characterization efforts within the OMC.

Heather Cowardin↗

Low Size, Weight, and Power Neuromorphic Computing to Improve Combustion Engine Efficiency

Neuromorphic computing offers one path forward for AI at the edge. However, accessing and effectively utilizing a neuromorphic hardware platform is non-trivial. In this work, we present a complete pipeline for neuromorphic computing at the edge, including a small, inexpensive, low-power, FPGA-based neuromorphic hardware platform, a training algorithm for designing spiking neural networks for neuromorphic hardware, and a software framework for connecting those components. We demonstrate this pipeline on a real-world application, engine control for a spark-ignition internal combustion engine. We illustrate how we connect engine simulations with neuromorphic hardware simulations and training software to produce hardware-compatible spiking neural networks that perform engine control to improve fuel efficiency. We present initial results on the performance of these spiking neural networks and illustrate that they outperform open-loop engine control. We also give size, weight, and power estimates for a deployed solution of this type.

Schuman, Catherine↗

Modeling of Multicomponent Trace Contaminant Adsorption on Activated Carbon

Modeling of multicomponent trace contaminant adsorption on activated carbon for spacecraft life support applications presents challenges due to the very low contaminant concentrations in cabin air coupled with very strong adsorption of heavier components such as cyclic polydimethylsiloxanes. Both gas-phase and solid-phase micropore mass transfer resistances can be important, and competitive interactions between adsorbed components can result in behavior such as roll-up where lighter components displaced by heavier components have a higher concentration at the outlet than at the inlet. This paper describes the further development of a dynamic trace contaminant adsorption model based on Ideal Adsorbed Solution Theory (IAST). Alternative 1-dimensional and 2-dimensional versions of the model are described with different mass transfer resistance and driving force assumptions. Optimization of solution methods for speed and stability is also described. Mass balance equations are scaled to provide sensitivity over the wide range of component concentrations in cabin air. Model parameters are estimated from isotherm and breakthrough test data on single adsorbate and binary adsorbate systems. Multicomponent results are compared against predictions of a heritage model used extensively by NASA for trace contaminant control system (TCCS) carbon bed sizing. Finally, efforts to implement the model in a second software platform for wider access are described.

Kevin E Lange↗

SU-F-I-37: How Fat Distribution and Table Height Affect Estimates of Patient Size in CT Scanning: A Phantom Study

Purpose: Localizer projection radiographs acquired prior to CT scans are used to estimate patient size, affecting the function of Automatic Tube Current Modulation (ATCM) and hence CTDIvol and SSDE. Due to geometric effects, the projected patient size varies with scanner table height and with the orientation of the localizer (AP versus PA). This study sought to determine if patient size estimates made from localizer scans is affected by variations in fat distribution, specifically when the widest part of the patient is not at the geometric center of the patient. Methods: Lipid gel bolus material was wrapped around an anthropomorphic phantom to simulate two different body mass distributions. The first represented a patient with fairly rigid fat and had a generally oval shape. The second was bell-shaped, representing corpulent patients more susceptible to gravity’s lustful tug. Each phantom configuration was imaged using an AP localizer and then a PA localizer. This was repeated at various scanner table heights. The width of the phantom was measured from the localizer and diagnostic images using in-house software. Results: 1) The projected phantom width varied up to 39% as table height changed.2) At some table heights, the width of the phantom, designed to represent larger patients, exceeded the localizer field of view, resulting in an underestimation of the phantom width.3) The oval-shaped phantom approached a normalized phantom width of 1 at a table height several centimeters lower (AP localizer) or higher (PA localizer) than did the bell-shaped phantom. Conclusion: Accurate estimation of patient size from localizer scans is dependent on patient positioning with respect to scanner isocenter and is limited in large patients. Further, patient size is more accurately measured on projection images if the widest part of the patient, rather than the geometric center of the patient, is positioned at scanner isocenter.

60 APPLIED LIFE SCIENCES↗

Narrow-line Seyfert 1 galaxies in Sloan Digital Sky Survey: a new optical spectroscopic catalogue

ABSTRACT Narrow-line Seyfert 1 (NLSy1) galaxies are an enigmatic class of active galactic nuclei (AGN) that exhibit peculiar multiwavelength properties across the electromagnetic spectrum. For example, these sources have allowed us to explore the innermost regions of the central engine of AGN using X-ray observations and have also provided clues about the origin of relativistic jets considering radio and gamma-ray bands. Keeping in mind the ongoing and upcoming wide-field, multifrequency sky surveys, we present a new catalogue of NLSy1 galaxies. This was done by carrying out a detailed decomposition of >2 million optical spectra of quasars and galaxies from the Sloan Digital Sky Survey Data Release 17 (SDSS-DR17) using the publicly available software ‘Bayesian AGN Decomposition Analysis for SDSS Spectra’. The catalogue contains 22656 NLSy1 galaxies which is more than twice the size of the previously identified NLSy1s based on SDSS-DR12. As a corollary, we also release a new catalogue of 52273 broad-line Seyfert 1 (BLSy1) galaxies. The estimated optical spectral parameters and derived quantities confirm the previously known finding of NLSy1 galaxies being AGN powered by highly accreting, low-mass black holes. We conclude that this enlarged sample of NLSy1 and BLSy1 galaxies will enable us to explore the low-luminosity end of the AGN population by effectively utilizing the sensitive, high-quality observations delivered by ongoing/upcoming wide-field sky surveys. The catalogue has been made public at https://www.ucm.es/blazars/seyfert.

Paliya, Vaidehi S. (ORCID:0000000177745308)↗

In-Situ Resource Utilization Modeling of a Lunar Water Processing System

A key element of achieving a sustained surface presence, such as defined in NASA’s Artemis plan, is In-Situ Resource Utilization (ISRU). ISRU is the practice of using local resources to provide mission consumables that reduce system launch mass requirements, and regenerate resources (chiefly, water and oxygen) for propulsion and life support supporting both Lunar and Martian missions. ISRU systems require multiple complex processes, such as excavation, chemical reactors, and electrolysis subsystems that must operate in harmony to optimize the overall system process from beginning to end. The Mission Analysis and Integration Tool (MAIT) was previously developed with MATLAB in FY22 to connect individual subsystem models into a customized, flexible framework for the purpose of technology downselect, optimization, and end-to-end process planning. Beginning in FY24, MAIT was updated and became the capital program in the Systems Engineering and Integration (SE&I) ISRU Modeling and Analysis (SIMA) project. Prior work was leveraged and evolved using MATLAB/Simulink due to its ability to communicate with a vast number of other programming languages and makes up the backbone of data flow between inputs and outputs to the subsystem models. MAIT initially evaluated a suite of ISRU-related technologies, including the water processing Lunar Auger Dryer for ISRU (LADI) system with integrated upstream excavation and downstream electrolysis subsystems. With individual models consolidated, the MAIT tool generated over 5,000 cases during its first round of parametric sweeps on the water processing architecture at multiple production targets; the system analysis produced valuable insight into the optimal LADI geometry that minimized energy demands, estimated effects to cold trap size and radiator requirements, and calculated the power dynamics of the electrolysis unit and liquid oxygen storage volume. Additional efforts are being made to demonstrate the ability to scale ISRU technologies supporting the Space Technology Mission Directorate’s (STMD) commercialization strategy and increase the MAIT software capability. Work is ongoing to handle a wide array of ISRU system models beyond the Lunar environment, e.g. production of propellant for a Martian lander.

Avery Carlson↗

In-Situ Resource Utilization Modeling of a Lunar Water Processing System

A key element of achieving a sustained surface presence, such as defined in NASA’s Artemis plan, is In-Situ Resource Utilization (ISRU). ISRU is the practice of using local resources to provide mission consumables that reduce system launch mass requirements, and regenerate resources (chiefly, water and oxygen) for propulsion and life support supporting both Lunar and Martian missions. ISRU systems require multiple complex processes, such as excavation, chemical reactors, and electrolysis subsystems that must operate in harmony to optimize the overall system process from beginning to end. The Mission Analysis and Integration Tool (MAIT) was previously developed with MATLAB in FY22 to connect individual subsystem models into a customized, flexible framework for the purpose of technology downselect, optimization, and end-to-end process planning. Beginning in FY24, MAIT was updated and became the capital program in the Systems Engineering and Integration (SE&I) ISRU Modeling and Analysis (SIMA) project. Prior work was leveraged and evolved using MATLAB/Simulink due to its ability to communicate with a vast number of other programming languages and makes up the backbone of data flow between inputs and outputs to the subsystem models. MAIT initially evaluated a suite of ISRU-related technologies, including the water processing Lunar Auger Dryer for ISRU (LADI) system with integrated upstream excavation and downstream electrolysis subsystems. With individual models consolidated, the MAIT tool generated over 5,000 cases during its first round of parametric sweeps on the water processing architecture at multiple production targets; the system analysis produced valuable insight into the optimal LADI geometry that minimized energy demands, estimated effects to cold trap size and radiator requirements, and calculated the power dynamics of the electrolysis unit and liquid oxygen storage volume. Additional efforts are being made to demonstrate the ability to scale ISRU technologies supporting the Space Technology Mission Directorate’s (STMD) commercialization strategy and increase the MAIT software capability. Work is ongoing to handle a wide array of ISRU system models beyond the Lunar environment, e.g. production of propellant for a Martian lander.

Avery Carlson↗

Characterization of differences in calculated and actual measured skin doses to canine limbs during stereotactic radiosurgery using Gafchromic film

Accurate calculation of absorbed dose to the skin, especially the superficial and radiosensitive basal cell layer, is difficult for many reasons including, but not limited to, the build-up effect of megavoltage photons, tangential beam effects, mixed energy scatter from support devices, and dose interpolation caused by a finite resolution calculation matrix. Stereotactic body radiotherapy (SBRT) has been developed as an alternative limb salvage treatment option at Colorado State University Veterinary Teaching Hospital for dogs with extremity bone tumors. Optimal dose delivery to the tumor during SBRT treatment can be limited by uncertainty in skin dose calculation. The aim of this study was to characterize the difference between measured and calculated radiation dose by the Varian Eclipse (Varian Medical Systems, Palo Alto, CA) AAA treatment planning algorithm (for 1-mm, 2-mm, and 5-mm calculation voxel dimensions) as a function of distance from the skin surface. The study used Gafchromic EBT film (International Specialty Products, Wayne, NJ), FilmQA analysis software, a limb phantom constructed from plastic water Trade-Mark-Sign (fluke Biomedical, Everett, WA) and a canine cadaver forelimb. The limb phantom was exposed to 6-MV treatments consisting of a single-beam, a pair of parallel opposed beams, and a 7-beam coplanar treatment plan. The canine forelimb was exposed to the 7-beam coplanar plan. Radiation dose to the forelimb skin at the surface and at depths of 1.65 mm and 1.35 mm below the skin surface were also measured with the Gafchromic film. The calculation algorithm estimated the dose well at depths beyond buildup for all calculation voxel sizes. The calculation algorithm underestimated the dose in portions of the buildup region of tissue for all comparisons, with the most significant differences observed in the 5-mm calculation voxel and the least difference in the 1-mm voxel. Results indicate a significant difference between measured and calculated data extending to average depths of 2.5 mm, 3.4 mm, and 10 mm for the 1-mm, 2-mm, and 5-mm dimension calculation matrices, respectively. These results emphasize the importance of selecting as small a treatment planning software calculation matrix dimension as is practically possible and of taking a conservative approach for skin treatment planning objectives. One suggested conservative approach is accomplished by defining the skin organ as the outermost 2-3 mm of the body such that the high dose tail of the skin organ dose-volume histogram curve represents dose on the deep side of the skin where the algorithm is more accurate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Software defined network inference with evolutionary optimal observation matrices

A key requirement for network management is the accurate and reliable monitoring of relevant network characteristics. In today's large-scale networks, this is a challenging task due to the scarcity of network measurement resources and the hard constraints that this imposes. Here, this paper proposes a new framework, called SNIPER, which leverages the flexibility provided by Software-Defined Networking (SDN) to design the optimal observation or measurement matrix that can lead to the best achievable estimation accuracy using Matrix Completion (MC) techniques. To cope with the complexity of designing large-scale optimal observation matrices, we use the Evolutionary Optimization Algorithms (EOA) which directly target the ultimate estimation accuracy as the optimization objective function. We evaluate the performance of SNIPER using both synthetic and real network measurement traces from different network topologies and by considering two main applications for per-flow size and delay estimations. Our results show that SNIPER can be applied to a variety of network performance measurements under hard resource constraints. For example, by measuring only 8.8% of all per-flow path delays in Harvard network [1], congested paths can be detected with probability of 0.94. Finally, to demonstrate the feasibility of our framework, we also have implemented a prototype of SNIPER in Mininet.

97 MATHEMATICS AND COMPUTING↗

Temperature Dependent Raman Spectroscopic Study of the Fe Doped La{sub 0.67}Sr{sub 0.33}MnO{sub 3} Prepared Using Ball Milling Method

Polycrystalline samples of La{sub 0.67}Sr{sub 0.33}Mn{sub 0.65}Fe{sub 0.35}O{sub 3} (LSMFO) were synthesized using the standard ball mill method with different calcination temperatures ranging from 800 to 1100°C for 7 h. The phase purity of these samples was confirmed using X-ray diffraction (XRD) patterns. All samples were found to have rhombohedral crystal structure with R 3-bar c space group. The lattice parameters, cell volume, bond angle and bond length have been obtained using the Rietveld refinement by FullProf software. The average crystallite size calculated using the Debye-Scherrer formula was found between 27 and 60 nm. Surface morphology of the prepared samples has been examined using a scanning electron microscope (SEM). SEM images show the formation of well-arranged grain sizes distributed from 240 to 400 nm, much larger than one estimated using the Scherrer formula. All tiny particles are highly agglomerated with the increasing temperature and porosity decreases with increasing temperature. An analysis of the frequency and peak broadening of Raman modes as a function of temperature clearly shows the significant temperature effect on the A{sub 1g} and E{sub g} modes of LSMFO. The shifts and broadening of the A{sub 1g} and E{sub g} modes are discussed in light of the oxygen sublattice distortion. Our study shows the reduction in distortion with increasing calcination temperature, which suggests a decrease in the JT effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Robust Vision-based Multi-spacecraft Guidance Navigation and Control using CNN-based Pose Estimation

In this paper, we present an end-to-end simulation framework for tracking an uncooperative Target spacecraft in Low Earth Orbit using a CubeSat-class Ego spacecraft outfitted with a camera. Currently, capturing high-fidelity realistic images in space for this scenario is difficult and exorbitantly expensive. Therefore, we developed a framework to simulate the spacecraft orbits in Basilisk software and generate high-fidelity realistic images of spacecraft in Unreal Engine, including the effects from Sun, Earth, Moon and stars. The Ego spacecraft uses cameras to capture images of the uncooperative Target and estimates its position and attitude using a CNN based 6DOF pose estimation pipeline, eliminating need for large SWAP-C(Size, Weight, Power and Cost) sensors like LIDAR or reliance on inter-spacecraft communication, This CNN, which is motivated by ESA’s Pose Estimation challenge of 2019, is trained using simulated data from our end-to-end simulation framework. We compare the performance of two distinct CNNbased algorithms for pose estimation along a nominal trajectory. In presence of non-Gaussian modeling uncertainties, the statedependent estimation error is characterized with a quadratic upper-bound. The quadratically-bounded error can be used by a robust controller to maneuver

Rahmani, Amir↗

Validation methods for flight crucial systems

Research to develop techniques that can aid in determining the reliability and performance of digital electronic fault-tolerant systems, that have probability of catastrophic system failure on the order of 10 to the -9th at 10 hours, is reviewed. The computer-aided reliability estimation program (CARE III) provides general-purpose reliability analysis and a design tool for fault-tolerant systems; large reduction of state size; and a fault-handling model based on probabilistic description of detection, isolation, and recovery mechanisms. The application of design proof techniques as part of the design and development of the software implemented fault-tolerance computer is mentioned. Emulation techniques and experimental procedures are verified using specimens of fault-tolerant computers and the capabilities of the validation research laboratory, AIRLAB.

Holt, H. M.↗

SU-E-J-06: Additional Imaging Guidance Dose to Patient Organs Resulting From X-Ray Tubes Used in CyberKnife Image Guidance System

Purpose: The use of image-guided radiation therapy (IGRT) has become increasingly common, but the additional radiation exposure resulting from repeated image guidance procedures raises concerns. Although there are many studies reporting imaging dose from different image guidance devices, imaging dose for the CyberKnife Robotic Radiosurgery System is not available. This study provides estimated organ doses resulting from image guidance procedures on the CyberKnife system. Methods: Commercially available Monte Carlo software, PCXMC, was used to calculate average organ doses resulting from x-ray tubes used in the CyberKnife system. There are seven imaging protocols with kVp ranging from 60 – 120 kV and 15 mAs for treatment sites in the Cranium, Head and Neck, Thorax, and Abdomen. The output of each image protocol was measured at treatment isocenter. For each site and protocol, Adult body sizes ranging from anorexic to extremely obese were simulated since organ dose depends on patient size. Doses for all organs within the imaging field-of-view of each site were calculated for a single image acquisition from both of the orthogonal x-ray tubes. Results: Average organ doses were <1.0 mGy for every treatment site and imaging protocol. For a given organ, dose increases as kV increases or body size decreases. Higher doses are typically reported for skeletal components, such as the skull, ribs, or clavicles, than for softtissue organs. Typical organ doses due to a single exposure are estimated as 0.23 mGy to the brain, 0.29 mGy to the heart, 0.08 mGy to the kidneys, etc., depending on the imaging protocol and site. Conclusion: The organ doses vary with treatment site, imaging protocol and patient size. Although the organ dose from a single image acquisition resulting from two orthogonal beams is generally insignificant, the sum of repeated image acquisitions (>100) could reach 10–20 cGy for a typical treatment fraction.

60 APPLIED LIFE SCIENCES↗

SU-F-T-300: Impact of Electron Density Modeling of ArcCHECK Cylindricaldiode Array On 3DVH Patient Specific QA Software Tool Analysis

Purpose: 3DVH software is a patient specific quality assurance tool which estimates the 3D dose to the patient specific geometry with the help of Planned Dose Perturbation algorithm. The purpose of this study is to evaluate the impact of HU value of ArcCHECK phantom entered in Eclipse TPS on 3D dose & DVH QA analysis. Methods: Manufacturer of ArcCHECK phantom provides CT data set of phantom & recommends considering it as a homogeneous phantom with electron density (1.19 gm/cc or 282 HU) close to PMMA. We performed this study on Eclipse TPS (V13, VMS) & trueBEAM STx VMS Linac & ArcCHECK phantom (SNC). Plans were generated for 6MV photon beam, 20cm×20cm field size at isocentre & SPD (Source to phantom distance) of 86.7 cm to deliver 100cGy at isocentre. 3DVH software requires patients DICOM data generated by TPS & plan delivered on ArcCHECK phantom. Plans were generated in TPS by assigning different HU values to phantom. We analyzed gamma index & the dose profile for all plans along vertical down direction of beam’s central axis for Entry, Exit & Isocentre dose. Results: The global gamma passing rate (2% & 2mm) for manufacturer recommended HU value 282 was 96.3%. Detector entry, Isocentre & detector exit Doses were 1.9048 (1.9270), 1.00(1.0199) & 0.5078(0.527) Gy for TPS (Measured) respectively.The global gamma passing rate for electron density 1.1302 gm/cc was 98.6%. Detector entry, Isocentre & detector exit Doses were 1.8714 (1.8873), 1.00(0.9988) & 0.5211(0.516) Gy for TPS (Measured) respectively. Conclusion: Electron density value assigned by manufacturer does not hold true for every user. Proper modeling of electron density of ArcCHECK in TPS is essential to avoid systematic error in dose calculation of patient specific QA.

60 APPLIED LIFE SCIENCES↗

Control Software for Piezo Stepping Actuators

A control system has been developed for the Space Interferometer Mission (SIM) piezo stepping actuator. Piezo stepping actuators are novel because they offer extreme dynamic range (centimeter stroke with nanometer resolution) with power, thermal, mass, and volume advantages over existing motorized actuation technology. These advantages come with the added benefit of greatly reduced complexity in the support electronics. The piezo stepping actuator consists of three fully redundant sets of piezoelectric transducers (PZTs), two sets of brake PZTs, and one set of extension PZTs. These PZTs are used to grasp and move a runner attached to the optic to be moved. By proper cycling of the two brake and extension PZTs, both forward and backward moves of the runner can be achieved. Each brake can be configured for either a power-on or power-off state. For SIM, the brakes and gate of the mechanism are configured in such a manner that, at the end of the step, the actuator is in a parked or power-off state. The control software uses asynchronous sampling of an optical encoder to monitor the position of the runner. These samples are timed to coincide with the end of the previous move, which may consist of a variable number of steps. This sampling technique linearizes the device by avoiding input saturation of the actuator and makes latencies of the plant vanish. The software also estimates, in real time, the scale factor of the device and a disturbance caused by cycling of the brakes. These estimates are used to actively cancel the brake disturbance. The control system also includes feedback and feedforward elements that regulate the position of the runner to a given reference position. Convergence time for smalland medium-sized reference positions (less than 200 microns) to within 10 nanometers can be achieved in under 10 seconds. Convergence times for large moves (greater than 1 millimeter) are limited by the step rate.

Shields, Joel F.↗

Library based x-ray scatter correction for dedicated cone beam breast CT

Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal views. Conclusions: The library-based scatter correction does not require increase in radiation dose or hardware modifications, and it improves over the existing methods on implementation simplicity and computational efficiency. As demonstrated through patient studies, the authors’ approach is effective and stable, and is therefore clinically attractive for CBBCT imaging.

60 APPLIED LIFE SCIENCES↗