Search NASA⌕ Search

SEARCH · Search NASA

Results for “solid state detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Technologies for the multispectral mapping of earth resources

The application of solid-state detector array imaging to the remote sensing of the earth as a follow-on to currently planned Landsat missions provides the opportunity to achieve significantly increased performance. First-order advantages to be anticipated are higher sensitivity resulting in greater radiometric accuracies and improved geometric fidelity. The Multispectral Mapper design concept is responsive to a broad range of user needs by incorporating in-flight selection of spectral bands, instantaneous fields of view, and swath width. This versatility is achieved by the use of an imaging spectrometer which permits both spatial and spectral sampling in the image plane using area array detectors. Other improvements over the current Landsat multispectral scanner and Thematic Mapper include higher spatial resolution and inherently precise registration of the spectral bands. The key technologies required in order to realize these improvements include short-wavelength infrared detectors, wide field of view, broad spectral coverage optics, focal plane cooling, and high-speed onboard signal processing. Significant development activities will be required if an advanced remote sensing capability is to be implemented.

Wellman, J. B.↗

ISEE/IMP observations of simultaneous upstream ion events

Propagation of upstream energetic (50-200 keV) ions is analyzed in sixteen events observed simultaneously by solid state detectors on ISEE 3 at about 200 earth radii and on IMP 8 at about 35 earth radii from the earth. Conclusions are based on comparisons of the pitch angle distributions observed at the two spacecraft and transformed into the solar wind frame. They are beamlike at ISEE 3 and are confined to the outward hemisphere. When IMP 8 is furthest from the bow shock, they are also usually beamlike, or hemispheric. However, when IMP 8 is closer to the bow shock, pancakelike distributions are observed. This systematic variation in the IMP 8 pitch angle distributions delimits a scattering region l less than about 15 earth radii upstream of the earth's bow shock (l measured along the interplanetary magnetic field) that dominates ion propagation, influences the global distribution of fluxes in the foreshock, and may play a role in acceleration of the ions. When IMP 8 is beyond l of about 15 earth radii the propagation appears to be essentially scatter-free between IMP 8 and ISEE 3; this is deduced from the absence of earthward fluxes at IMP 8 as well as the tendency for the spin-averaged fluxes to be comparable at the two spacecraft.

Mitchell, D. G.↗

Iron charge states observed in the solar wind

Solar wind measurements from the ULECA sensor of the Max-Planck-Institut/University of Maryland experiment on ISEE-3 are reported. The low energy section of approx the ULECA sensor selects particles by their energy per charge (over the range 3.6 keV/Q to 30 keV/Q) and simultaneously measures their total energy with two low-noise solid state detectors. Solar wind Fe charge state measurements from three time periods of high speed solar wind occurring during a post-shock flow and a coronal hole-associated high speed stream are presented. Analysis of the post-shock flow solar wind indicates the charge state distributions for Fe were peaked at approx +16, indicative of an unusually high coronal temperature (3,000,000 K). In contrast, the Fe charge state distribution observed in a coronal hole-associated high speed stream peaks at approx -9, indicating a much lower coronal temperature (1,400,000 K). This constitutes the first reported measurements of iron charge states in a coronal hole-associated high speed stream.

Ipavich, F. M.↗

The ISPM experiment for spectral, composition and anistropy measurements of charged particles at low energie

The Heliosphere Instrument for Spectral, Composition, and Anisotropy at Low Energies (HI-SCALE) designed to measure interplanetary ions and electrons is described. Ions and electrons are detected by five separate solid-state detector telescopes oriented to give complete pitch angle coverage from the spinning spacecraft. Ion elemental abundances are determined by a telescope using a thin front detector element in a three-element telescope. Experiment operation is controlled by a microprocessor-based data system. Inflight calibration is provided by radioactive sources mounted on closable telescope covers. Ion and electron spectral information is determined using broad-energy-range rate channels, and a pulse-height analyzer for more detailed spectra. The instrument weighs 5.775 kg and uses 4.0 W power.

Lanzerotti, L. J.↗

Optical analysis of the star-tracker telescope for Gravity Probe

A ray tracing modeling of the star tracker telescope for Gravity Probe was used to predict the character of the output signal and its sensitivity to fabrication errors. In particular, the impact of the optical subsystem on the requirement of 1 milliarc second signal linearity over a + or - 50 milliarc second range was examined. Photomultiplier and solid state detector options were considered. Recommendations are made.

Zissa, D. E.↗

Non Equilibrium Ionization in the Local Hot Bubble

The existence of a local hot bubble surrounding the solar system was shown by soft X-ray surveys. The spectrum of this hot interstellar medium was measured with solid state detectors during rocket flights between 300 and 1000 eV. The good resolution of the experiment permitted to measure C V, C VI and O VII line emissivities with good accuracy. These data are used to put some constraints on a model where the emission comes from a supernova remnant expanding in a finite pressure medium. The importance of nonequilibrium ionization phenomena is shown.

Arnaud, M.↗

Some design considerations for a satellite-borne magnetograph

The design criteria for a compact magnetograph that can monitor solar magnetic fields from a free-flying satellite for 5 to 10 years are reviewed. The signal-to-noise ratio that can be obtained with a 10-cm f/10 refractor operated with a Fabry-Perot filter and a solid-state detector array is derived. The telescope measures the longitudinal component of the magnetic field for the entire solar disk in a few minutes at a 20-G threshold and at 3-arcsec resolution. The Fabry-Perot filter has a lithium niobate etalon, which can be tuned electrically and operated at a fixed tilt angle in such a manner that it cancels the solar rotational Doppler shifts in the transmitted spectrum. Principles of operation of various types of polarization modulators are presented, and it is concluded that photoelastic modulators and liquid-crystal devices hold the most promise for use in a satellite-borne magnetograph,

Rust, D. M.↗

Cosmic X-ray physics

The analysis of the beryllium-filtered data from Flight 17.020 was completed. The data base provided by the Wisconsin diffuse X-ray sky survey is being analyzed by correlating the B and C band emission with individual velocity components of neutral hydrogen. Work on a solid state detector to be used in high resolution spectroscopy of diffuse or extend X-ray sources is continuing. A series of 21 cm observations was completed. A paper on the effects of process parameter variation on the reflectivity of sputter-deposited tungsten-carvon multilayers was published.

Mccammon, D.↗

Energetic neutral atoms (E approximately 50 keV) from the ring current - IMP 7/8 and ISEE 1

Energetic neutral atoms (ENA), emitted from the magnetosphere with energies of about 50 keV, have been measured with solid state detectors on the IMP 7/8 and ISEE 1 spacecraft; they are produced when singly charged trapped ions collide with the exosphere neutral hydrogen geocorona and the energetic ions are neutralized by charge exchange. ENA observations during the recovery phase of two moderate geomagnetic storms are analyzed: November 22-23, 1973, from IMP 8 at 33 earth radii and December 17, 1977, from ISEE 1 at 20 earth radii.

Roelof, E. C.↗

Comet Giacobini-Zinner - In situ observations of energetic heavy ions

Conclusive evidence is presented for the existence of heavy energetic, singly charged cometary ions within 1.5 million km of comet Giacobini-Zinner. The most direct evidence for establishing the mass of these ions was obtained from an analysis of the energy signals in one of the solid state detector on board the International Cometary Explorer. Maximum fluxes were recorded approximately one hour before and after closest approach to the cometary nucleus. Transformation of the particle angular distribution observed at approximately 50,000 km radial distance from the comet, during the inbound pass into a rest frame in which the distributions are nearly isotropic, requires a transformation velocity that is consistent with the local solar wind velocity (assuming these particles are primarily singly ionized with a mass of 18 + or - 6 amu). It is implied that these water-group ions underwent strong pitch angle scattering subsequent to ionization and that they were accelerated or heated. The derived ion density, approximately 0.1/cu cm, is consistent with a crude model for the production and transport of pickup ions.

Ipavich, F. M.↗

High energy irradiations simulating cosmic-ray-induced planetary gamma ray production. I - Fe target

Two thick Fe targets were bombarded by a series of 6 GeV proton irradiations for the purpose of simulating the cosmic ray bombardment of planetary objects in space. Gamma ray energy spectra were obtained with a germanium solid state detector during the bombardment, and 46 of the gamma ray lines were ascribed to the Fe targets. A comparison between observed and predicted values showed good agreement for Fe lines from neutron inelastic scattering and spallation reactions, and less satisfactory agreement for neutron capture reactions, the latter attributed to the difference in composition between the Fe target and the mean lunar abundance used in the modeling. Through an analysis of the irradiation results together with continuum data obtained in lunar orbit, it was found that 100 hours of measurement with a current instrument should generate a spectrum containing approximately 20 lines due to Fe alone, with a 2-sigma sensitivity for detection of about 0.2 percent.

Metzger, A. E.↗

Studies of the composition of solar particles and of energetic oxygen and sulfur nuclei trapped in the Jovian magnetosphere

The Cosmic Ray System (CRS) experiment on board each of the Voyager 1 and 2 spacecraft consists of four Low Energy Telescopes (LETs), two High Energy Telescopes (HETs), the Electron Telescope (TET), and associated electronics. With these instruments it is possible to measure the energy spectrum of electrons over the 3-110MeV energy range and the energy spectra and nuclear charge of atomic nuclei from hydrogen through zinc over the 3-500 MeV/nuc energy range. The exclusive use of solid-state detectors in the CRS telescopes achieves the objectives of reliability over a long mission life, high resolution determinations of energy and charge, and high-count-rate capability during large solar flares and passage through the magnetospheres of the outer planets. Summarized here are some of the many accomplishments that have resulted from the CRS measurements during the period covered by this report, May 15, 1981 to May 15, 1984, including studies of the energetic oxygen and sulfur nuclei trapped in the Jovian magnetosphere.

Stone, E. C.↗

Modifications of the X-ray source and monitor at the X-ray Calibration Facility

In order to test the instruments aboard the Advanced X-ray Astrophysics Facility (AXAF) some modifications will need to be made in the X-ray Calibration Facility at Marshall. Several of these modifications involve the X-ray source and the monitor. The source was redesigned to increase the spectral purity of the beam and decrease its polarization by minimizing the number of bremsstrahlung photons in the beam. This was accomplished by utilizing an annular electron gun which allowed the beam to take off antiparallel to the direction at which electrons are incident on the anode. Two other features of the source are the conical anode which decreases the effective spot size and a rotatable anode and filter wheel which allow the operator to change targets without breaking vacuum. The monitor is an important part of the facility because it is used to determine the X-ray flux at the target. A commercially available solid-state detector, Si(Li), should be used along with appropriate proportional counters for monitoring. This detector will be particularly useful when energy or wavelength dispersive instruments are tested because of its good resolution.

Newbolt, W. Barlow↗

Atmospheric science on the Galileo mission

The atmospheric science goals of the Galileo mission, and instruments of the probe and orbiter are described. The current data available, and the goals of the Galileo mission concerning the chemical composition of the Jovian atmosphere; the thermal structure of the atmosphere; the nature of cloud particles and cloud layering; the radiative energy balance; atmospheric dynamics; and the upper atmosphere are discussed. The objectives and operations of the atmospheric structure instrument, neutral mass spectrometer, helium abundance interferometer, nephelometer, net flux radiometer, lightning and radio emission detector, solid state imaging system, NIR mapping spectrometer, photopolarimeter radiometer, and UV spectrometer are examined.

Hunten, D. M.↗

Image reconstruction from multiple 1-D scans using filtered localized projection

The spatial resolution that can be attained using scanning linear arrays (consisting of discrete IR solid-state detectors) for image acquisition is considered, and a filtered local projection (FLP) method is described which efficiently combines all available scan information into one rectangular grid without the need for explicit interpolation. Mathematically, the FLP algorithm consists of a localized summation followed by an inverse-filter operation, and it has application to nonlinear restoring techniques. The present method is applied, using a linear array, to simulated data for staggered parallel scans and to multiple scan directions. Noise effects and limitations of the technique are also considered.

Frieden, B. Roy↗

Application of PN and avalanche silicon photodiodes to low-level optical

New approaches to the discovery of other planetary systems require very sensitive and stable detection techniques in order to succeed. Two methods in particular, the astrometric and the photometric methods, require this. To begin understanding the problems and limitations of solid state detectors regarding this application, preliminary experiments were performed at the National Bureau of Standards and a low light level detector characterization facility was built. This facility is briefly described, and the results of tests conducted in it are outlined. A breadboard photometer that was used to obtain stellar brightness ratio precision data is described. The design principles of PN and avalanche silicon photodiodes based on low light level measuring circuits are discussed.

Eppeldauer, G.↗

The abundances of elements and isotopes in the solar wind

Studies of the chemical and isotopic composition of the solar wind are reviewed. Solar wind abundance measurements are discussed and solar wind, coronal, and photospheric abundances for elements between H and Fe are presented. Also, consideration is given to the determination of the solar wind isotopic composition of the noble gases using foil collection techniques and the observation of solar wind heavy ions with the mass per charge spectrometer on ISEE-3. Other topics include solar wind observations with solid state detectors, solar wind abundances in the magnetosheath and the plasma sheet, and high-mass resolution measurements of chemical elements and isotopes in the solar wind.

Gloeckler, George↗

Wide range magnetic electron spectrograph

An electron spectrogrpah is described that covers electron energies from 400 eV to 200 keV with an energy resolution of 10 percent. This overlaps the range of electrostatic deflection devices at low energy and solid state detectors at high energy. The spectrograph uses magnetic deflection of the electrons to achieve energy separation and images the full range of energies on a single plane. The magnetic circuit uses the fringing field of two axially located magnets to attain the large energy range. Six separate electron beams can be dispersed in the field, each entering the circuit from a different angle. This is a particular advantage when measuring plasma electron three-dimensional velocity distributions. The angular response of the instrument is particularly favorable and the stray magnetic field is sufficiently low to meet spacecraft requirements.

Coplan, M. A.↗