At least 127 records · Page 7

High Resolution Spectroscopy to Support Atmospheric Measurements

Spectroscopic parameters (such as line position, intensity, broadening and shifting coefficients and their temperature dependences, line mixing coefficients etc.) for various molecular species of atmospheric interest are determined. In order to achieve these results, infrared spectra of several molecular bands are obtained using high-resolution recording instruments such as tunable diode laser spectrometer and Fourier transform spectrometers. Using sophisticated analysis routines (Multispectrum nonlinear least squares technique) these high-resolution infrared spectra are processed to determine the various spectral line parameters that are cited above. Spectra were taken using the McMath-Pierce Fourier transform spectrometer (FTS) at the National Solar Observatory on Kitt Peak, Arizona as well as the Bruker FTS at the Pacific Northwest National Laboratory (PNNL) at Richland, Washington. Most of the spectra are acquired not only at room temperature, but also at several different cold temperatures. This procedure is necessary to study the variation of the spectral line parameters as a function of temperature in order to simulate the Earth's and other planetary atmospheric environments. Depending upon the strength or weakness of the various bands recorded and analyzed, the length(s) of the absorption cells in which the gas samples under study are kept varied from a few centimeters up to several meters and the sample temperatures varied from approximately +30 C to -63 C. Research on several infrared bands of various molecular species and their isotopomers are undertaken. Those studies are briefly described.

Venkataraman, Malathy Devi↗

Bragg crystal spectrometer for HEAO-B X-ray astronomy experiment

The X-ray astronomy experiment for the HEAO mission is described. The instrument to be flown on the satellite consists of two Bragg crystal spectrometers designed to make measurements with high spectral resolution in the energy range from 0.1 to 10 keV. No sharp spectroscopic features were detected directly in X-ray astronomy except emission lines in the sun; therefore, the objectives and design criteria of this instrument are based on the theoretical models of the different types of extra solar X-ray sources. From the point of view of instrumental techniques it is convenient to divide these into point or stellar sources, whose radiation is parallel, and diffuse sources, and to consider the possible spectral features in each type.

Angel, J. R. P.↗

A ground-based technique for millimeter wave spectroscopic observations of stratospheric trace constituents

Recent concern over possible long term stratospheric changes caused by the introduction of man-made compounds has increased the need for instrumentation that can accurately measure stratospheric minor constituents. The technique of radio spectroscopy at millimeter wavelengths was first used to observe rotational transitions of stratospheric ozone nearly two decades ago, but has not been highly developed until recently. A ground-based observing technique is reported which employs a millimeter-wave superheterodyne receiver and multichannel filter spectrometer for measurements of stratospheric constituents that have peak volume mixing ratios that are less than 10 to the -9th, more than 3 orders of magnitude less than that for ozone. The technique is used for an extensive program of observations of stratospheric chlorine monoxide and also for observations of other stratospheric trace gases such as (O-16)3, vibrationally excited (O-16)3, (O-18)2(O-16), N2O, HO2, and HCN. In the present paper, analysis of the observing technique is given, including the method of calibration and analysis of sources of error. The technique is found to be a reliable means of observing and monitoring important stratospheric trace constituents.

Parrish, A.↗

Icy Satellites of the Planets, and the Work of V.I. Moroz

The satellites of the giant planets are highly varied in size and density, indicating a wide range of compositions. The principal components of these satellites are ices of many different compositions (with H2O the most abundant) and varying amounts of silicate rocky material. Many different ices have been found by spectroscopic techniques both from Earth-based observatories and from planetary spacecraft. Three of the Galilean satellites of Jupiter exhibit H2O ice on their surfaces, while small amounts of CO2 are present on Ganymede and Callisto. The volcanic satellite Io has abundant SO2 ice and frost deposits. Saturn s satellites have surfaces dominated by H2O ice, but CO2 is also present on most of them, and in the cases of the low-albedo satellites Iapetus and Phoebe, there is evidence of complex hydrocarbons mixed with the surface materials. The large Uranian satellites also have H2O-dominated surfaces, but CO2 has also been discovered on two of them. Neptune s largest satellite, Triton, show spectroscopic evidence for six different ices, including N2, CH4, CO, CO2, H2O, and C2H6. The latter ice is a photochemical product from the action of sunlight on Triton's atmosphere. Pluto is similar to Triton, although CO2 has not been found. Pluto s large satellite, Charon, shows evidence for an ammonia hydrate on part of its surface. V. I. Moroz was a pioneer in the application of near-infrared detectors to astronomical sources. Using a prism spectrometer he measured the spectra of the Galilean satellites of Jupiter, and in 1966 he published the first near-infrared spectra, noting the appearance of H2O ice as a major component of Europa and Ganymede. This discovery, and the techniques of Moroz measurements help set the stage for the broad extension of the study of planetary, satellite, and asteroid surfaces through reflectance spectroscopy in the near-infrared.

Cruikshank, Dale P.↗

The APX Spectrometer for Martian Missions

Obtaining the chemical composition of any planetary body should be a prime science objective of each planetary mission. The APX spectrometer has been designed to provide a detailed and complete chemical composition of all major (except H) and minor elements with high accuracy, in situ and remotely. From such complete analyses a first-order mineralogy of analyzed samples can be deduced. Laboratory studies in the past have shown that rock types (e.g., dunites, basalts, Philippinate 300 sample) were a uniquely in blind test analyses. Such identification is more accurate than can be obtained from any other remote spectroscopic technique. The APX technique is based on three modes of nuclear and atomic interactions of alpha particles with matter resulting in three different energy spectra containing the compositional information. The instrument uses 50 to 100 mCi of Cm-242 or Cm-244 transuranium radioisotopes to provide a monoenergetic beam of alpha particles (6.01 MeV and 5.80 MeV respectively) and solid-state detectors for acquiring the energy spectra.

Economou, T.↗

Tooling Techniques Enhance Medical Imaging

They can release as much energy as tens of billions of hydrogen bombs exploding at the same time. They send protons and electrons rocketing at near the speed of light. They heat gas in the Sun s atmosphere to tens of millions of degrees Celsius. They send a blast of gas and particles toward Earth, posing a danger to spacecraft and astronauts outside the planet s magnetosphere, in rare cases even knocking out radio communications and power grids on the ground. They are so-called solar eruptive events, made up of solar flares and the often associated coronal mass ejections. Because of the scientific mystery of how these solar eruptions are produced on the Sun with such scale and force, and also the major role they play in space weather that can impact life on Earth, NASA researchers have innovated new methods of gathering information about these violent events. One NASA mission, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) has significantly advanced understanding of solar flares since its launch in 2002. RHESSI scientists use the spacecraft s imaging spectrometer to piece together pictures of solar flares from the high-energy X-ray and gamma-ray radiation they emit. While there is still much to be learned, data gathered by RHESSI has revealed how magnetic fields in the vast expanse of the solar atmosphere may be the force that drives the immense explosions. The instrument has imaged around 50,000 flares to date, providing information that may explain not only the workings of solar flares but also of much more massive energy releases from distant objects like black holes and quasars. We have been able to make images from X-rays with much finer resolution and greater sensitivity than have ever been made before, says Brian Dennis, RHESSI Mission Scientist and astrophysicist in the Solar Physics Laboratory at Goddard Space Flight Center. The key to RHESSI s unprecedented capabilities lie in a set of essential components a NASA partner created for the mission. The manufacturing techniques developed to create the components have yielded innovations advancing medical imaging, transportation security, and even energy efficiency.

Source record↗

X-ray spectrometer spectrograph telescope system

A new sounding rocket payload that has been developed for X-ray spectroscopic studies of the solar corona is described. The instrument incorporates a grazing incidence Rowland mounted grating spectrograph and an extreme off-axis paraboloic sector feed system to isolate regions of the sun of order 1 x 10 arc seconds in size. The focal surface of the spectrograph is shared by photographic and photoelectric detection systems, with the latter serving as a part of the rocket pointing system control loop. Fabrication and alignment of the optical system is based on high precision machining and mechanical metrology techniques. The spectrograph has a resolution of 16 milliangstroms and modifications planned for future flights will improve the resolution to 5 milliangstroms, permitting line widths to be measured.

Bruner, E. C., Jr.↗

Development of a narrow stopband filter for spectroscopic fast ion deuterium-alpha measurements

A new technique to attenuate the unshifted deuterium Balmer-alpha (D-alpha) emission is developed and tested for the fast ion D-alpha (FIDA) diagnostic. The unshifted D-alpha emission, at λ = 656.1 nm, is around three orders of magnitude higher than the desired FIDA emission. Blocking the strong emission feature is essential to prevent blooming and light smearing on the CCD chip and scattered light contamination. The new method is a notch filter approach that utilizes the reflection from ultra-narrow bandpass filters to block the saturating signal before it enters the spectrometer. Collimated light from the fibers is reflected off the filter at a 15° angle of incidence. Measurements show that a center wavelength transmission of 0.006 and a blocking full width at half maximum of ~ 1 nm are achieved by using a 200 μm fiber and a 20 mm focal length collimator with two filters.

47 OTHER INSTRUMENTATION↗

Microshutter Arrays for the JWST NIRSpec

A primary goal of the James Webb Space Telescope (JWST) is to characterize the birth and evolution of galaxies by imaging and spectroscopic observations. The telescope will use a Near Infrared Camera and a Near Infrared Spectrometer (NIRSpec) to carry out this program. The 3.6 x 3.6 field of NIRSpec will contain thousands of candidate high redshift galaxies. With such a high candidate object density, simultaneous multi-object capability is essential. This capability requires a programmable object selection mask to eliminate sky background and to reduce source confusion caused. We are developing a two-dimensional programmable field mask for NIRSpec. These masks employ micromechanical (MEMS) techniques to provide source selection over the NIRSpec field of view. The first flight format arrays (171x365 shutters) have been fabricated and full functionality of these arrays has been demonstrated in lab tests. Qualification tests are in progress to demonstrate readiness for flight, and will be complete in the early fall of 2006. In this paper, I describe performance of this critical new technology, and progress in making the devices ready for a 2008 delivery to ESA for inclusion in the NIRSpec.

Moseley, Samuel H.↗

Microshutter Arrays for the JWST NIRSpec

A primary goal of the James Webb Space Telescope (JWST) is to characterize the birth and evolution of galaxies by imaging and spectroscopic observations. The telescope will use a Near Infrared Camera and a Near Infrared Spectrometer (NIRSpec) to carry out this program. The 3.6' x 3.6' field of NIRSpec will contain thousands of candidate high redshift galaxies. With such a high candidate object density, simultaneous multi-object capability is essential. This capability requires a programmable object selection mask to eliminate sky background and to reduce source confusion caused. We are developing a two-dimensional programmable field mask for NIRSpec. These masks employ micromechanical (MEMS) techniques to provide source selection over the NIRSpec field of view. The first flight format arrays (171x365 shutters) have been fabricated and full functionality of these arrays has been demonstrated in lab tests.

Moseley, Samuel H.↗

MACS, An Instrument, and a Methodology for Simulations and Global Measurements of the Coronal Electron Temperature and the Solar Wind Velocity on the Solar Corona

The determination of the radial and latitudinal temperature and wind profiles of the solar corona is of great importance in understanding the coronal heating mechanism and the dynamics of coronal expansion. Cram presented the theory for the formation of the K-coronal spectrum and identified two important observations. He observed the existence of temperature sensitive anti-nodes at certain wavelengths in the theoretical K-coronal spectra. The anti-nodes are separated by temperature-insensitive nodes. Remarkably, Cram showed that the wavelengths of the nodes and anti-nodes are almost independent of altitude above the solar limb. Because of these features, Cram suggested that the intensity ratios at two anti-nodes could be used as a diagnostic of the electron temperature in the K-corona. Based on this temperature diagnostic technique prescribed by Cram a slit-based spectroscopic study was performed by Ichimoto et al. on the solar corona in conjunction with the total solar eclipse of 3 Nov 1994 in Putre, Chile to determine the temperature profile of the solar corona. In this thesis Cram's theory has been extended to incorporate the role of the solar wind in the formation of the K-corona, and we have identified both temperature and wind sensitive intensity ratios. The instrument, MACS, for Multi Aperture Coronal Spectrometer, a fiber optic based spectrograph, was designed for global and simultaneous measurement of the thermal electron temperature and the solar wind velocity in the solar corona. The first ever experiment of this nature was conducted in conjunction with the total solar eclipse of 11 Aug 1999 in Elazig, Turkey. In this instrument one end of each of twenty fiber optic tips were positioned in the focal plane of the telescope in such a way that we could observe conditions simultaneously at many different latitudes and two different radial distances in the solar corona. The other ends of the fibers were vertically aligned and placed at the primary focus of the collimating lens of the spectrograph to obtain simultaneous and global spectra on the solar corona. By isolating the K-coronal spectrum from the spectrum recorded by each fiber the temperature and the wind sensitive intensity ratios were calculated to obtain simultaneous and global measurements of the thermal electron temperature and the solar wind velocity. We were successful in obtaining reliable estimates of the coronal temperature at many positions in the corona. This is the first time that simultaneous measurements of coronal temperatures have been obtained at so many points. However due to instrumental scattering encountered during observations, reliable estimates of the wind velocity turned out to be impossible to obtain. Although remedial measures were taken prior to observation, this task proved to be difficult owing to the inability to replicate the conditions expected during an eclipse in the laboratory. The full extent of the instrumental scattering was apparent only when we analyzed the observational sequence. Nevertheless the experience obtained from this very first attempt to simultaneously and globally measure both the wind velocity and the temperature on the solar corona have provided valuable information to conduct any future observations successfully.

Reginald, Nelson L.↗

FTIR Spectroscopic Characterization Of II-VI Semiconductors

Combination of commercial Fourier-transform infrared (FTIR) spectrometer with computer and special-purpose software constitutes highly automated facility for acquisition and processing of infrared transmission or reflection spectral image data. Intended principally to acquire transmission spectra of some compounds of elements in groups II and VI of periodic table. System used to characterize specimens of II/VI alloy semiconductors grown by directional solidification and quenching. Transmission-edge maps helpful in studies of flows, gradients of temperature, and coefficients of diffusion in solidifying melts. Data acquired by system include optical characteristics, and they both verify and complement data obtained by such other techniques as measurements of density and x-ray-dispersion analysis.

Perry, G. L. E.↗

Far infrared measurement of stratospheric HCl

Thermal emission from three rotational lines of H(Cl-35) and H(Cl-37) was observed with a Fourier transform spectrometer from a balloon platform at 28.9 km. The measured HCl line-of-sight density at 1.9 deg elevation above 28.9 km is 4.7 + or - 1.3 x 10 to the 15th/sq cm, implying an average volume mixing ratio of 0.8 + or - 0.2 x 10 to the -9th at the mean sampling altitude of 32.5 km. For a uniform mixing ratio model, this corresponds to a vertical column density of 2.4 + or - 0.6 x 10 to the 14th/sq cm. This result is in reasonable agreement with near infrared spectroscopic determinations and an abundance from a chemical sampling technique of HCl at this altitude; a pressure modulator radiometer measurement yields a significantly higher amount of HCl.

Chance, K. V.↗

Magnetic canopies and models of the solar chromosphere

Magnetic canopies are the topologies formed by magnetic field lines as they spread from compact, nearly vertical concentrations of flux in the low photosphere into the large-scale organization of the corona and heliosphere. Analytical techniques for inferring the base-heights of canopies from magnetographic data are reviewed together with observational evidence that much of the sun is covered by canopies which lie two or more pressure scale heights below the level which is traditionally inferred from thin flux tube models. Implications of these results for modeling the structure and energetics of the chromosphere are discussed, and it is argued that future models should be based upon both spectroscopic and polarimetric data. Recent improvements in magnetostatic model atmospheres are reviewed, and new observational data, including C IV Doppler-grams from the Ultraviolet Spectrometer and Polarimeter on the Solar Maximum Mission, are considered. Directions for future research in MHD modeling of canopies, in simulating spectrographic and polarimetric data from such models, and in observational programs are discussed.

Jones, H. P.↗

Tunable laser heterodyne spectrometer measurements of atmospheric species

It is pointed out that spectroscopic measurements conducted with the aid of tunable laser heterodyne spectrometers in the 3-30 micron range of the electromagnetic spectrum have the potential to measure the vertical profiles of tenuous gas molecules in the atmosphere with ultra high spectral resolution and great sensitivity. Programs related to the realization of this potential have been conducted for some time, and a Laser Heterodyne Spectrometer (LHS) experiment was developed. The present investigation has the objective to provide an overview of the LHS concept for measuring the vertical profiles of tenuous gas molecules in the upper atmosphere from space and airborne platforms, and to discuss the sensitivity ranges for this technique.

Allario, F.↗

Spectroscopic Determination of Trace Contaminants in High Purity Oxygen

Oxygen used for extravehicular activities (EVA) must be free of contaminants because a difference in a few tenths of a percent of argon or nitrogen content can mean significant reduction in available EVA time. These inert gases build up in the extravehicular mobility unit because they are not metabolized or scrubbed from the atmosphere. Measurement of oxygen purity above 99.5% is problematic, and currently only complex instruments such as gas chromatographs or mass spectrometers are used for these determinations. Because liquid oxygen boil-off from the space shuttle will no longer be available to supply oxygen for EVA use, other concepts are being developed to produce and validate high purity oxygen from cabin air aboard the International Space Station. A prototype optical emission technique capable of detecting argon and nitrogen below 0.1% in oxygen was developed at White Sands Test Facility. This instrument uses a glow discharge in reduced pressure gas to produce atomic emission from the species present. Because the atomic emission lines from oxygen, nitrogen, and argon are discrete and in many cases well-separated, trace amounts of argon and nitrogen can be detected in the ultraviolet and visible spectrum. This is a straightforward, direct measurement of the target contaminants and may lend itself to a device capable of on-orbit verification of oxygen purity. System design and optimized measurement parameters are presented.

Hornung, Steven D.↗

Direct reactions with the AT-TPC

Direct reactions are crucial tools for accessing properties of the atomic nucleus. Fundamental and exotic phenomena such as collective modes, pairing, weakbinding effects and evolution of single-particles energies can be investigated in peripheral collisions between a heavy nucleus and a light target. The necessity of using inverse kinematics to reveal how these structural properties change with isospin imbalance renders direct reactions a challenging technique when using the missing mass method. In this scenario, Active Target Time Projection Chambers (AT-TPC) have demonstrated an outstanding performance in enabling these types of reactions even under conditions of very low beam intensities. The AT-TPC of the Facility for Rare Isotope Beams (FRIB) is a next generation multipurpose Active Target. When operated inside a solenoidal magnet, direct reactions benefit from the measurement of the magnetic rigidity that enables particle identification and the determination of the excitation energy with high resolution without the need of auxiliary detectors. Additionally, the AT-TPC can be coupled to a magnetic spectrometer improving even further its spectroscopic investigation capability. In this contribution, we discuss inelastic scattering and transfer reaction data obtained via the AT-TPC and compare them to theory. In particular, we present the results for the 14 C(p,p′) and 12 Be (p,d) 11 Be reactions. For 14 C, we compare the experimental excitation energy of the first 1 – excited state with coupled-cluster calculationsbased on nuclear interactions from chiral effective field theory and with available shell-model predictions. For 12 Be, we determine the theoretical spectroscopic factors of the 12 Be (p,d) 11 Be transfer reaction in the shell modeland compare them to the experimental excitation spectrum from a qualitative standpoint.

active target↗

An imaging extreme ultraviolet spectrometer for astrophysical investigations in space

A high-efficiency, extreme ultraviolet (EUV) imaging spectrometer has been constructed and tested. The spectrometer employs a concave toroidal grating illuminated at normal incidence in a Rowland circle mounting and has only one reflecting surface. The toroidal grating has been fabricated by a new technique employing an elastically deformable submaster grating which is replicated in a spherical form and then mechanically distorted to produce the desired aspect ratio of the toroidal surface for stigmatic imaging over the selected wavelength range. The fixed toroidal grating used in the spectrometer is then replicated from this surface. Photographic tests and initial photoelectric tests with a two-dimensional, pulse-counting detector system have verified the image quality of the toroidal grating at wavelengths near 600 A. The basic designs of two instruments employing the spectrometer for astrophysical investigations in space are described, namely, a high-resolution EUV spectroheliometer for studies of the solar chromosphere, transition region, and corona; and an EUV spectroscopic telescope for studies of nonsolar objects.

Huber, M. C. E.↗