Search NASA⌕ Search

SEARCH · Search NASA

Results for “standard model tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Anomalies in global SMEFT analyses. A case study of first-row CKM unitarity

Recent developments in the Standard Model analysis of semileptonic charged-current processes involving light quarks have revealed ~ 3σ tensions in Cabibbo universality tests involving meson, neutron, and nuclear beta decays. In this paper, we explore beyond the Standard Model explanations of this so-called Cabibbo Angle Anomaly in the framework of the Standard Model Effective Field Theory (SMEFT), including not only low-energy charged current processes (‘L’), but also electroweak precision observables (‘EW’) and Drell-Yan collider processes (‘C’) that probe the same underlying physics across a broad range of energy scales. The resulting ‘CLEW’ framework not only allows one to test explanations of the Cabibbo Angle Anomaly, but is set up to provide near model-independent analyses with minimal assumptions on the flavor structure of the SMEFT operators. Besides the global analysis, we consider a large number of simpler scenarios, each with a subset of SMEFT operators, and investigate how much they improve upon the Standard Model fit. We find that the most favored scenarios, as judged by the Akaike Information Criterion, are those that involve right-handed charged currents. Additional interactions, namely oblique operators, terms modifying the Fermi constant, and operators involving right-handed neutral currents, play a role if the CDF determination of the W mass is included in the analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards a real-time computation of timelike hadronic vacuum polarization and light-by-light scattering: Schwinger Model tests

Hadronic vacuum polarization (HVP) and light-by-light scattering (HLBL) are crucial for evaluating the Standard Model predictions concerning the muon’s anomalous magnetic moment. However, direct first-principle lattice gauge theory-based calculations of these observables in the timelike region remain challenging. Discrepancies persist between lattice quantum chromodynamics (QCD) calculations in the spacelike region and dispersive approaches relying on experimental data parametrization from the timelike region. Here, we introduce a methodology employing 1+1-dimensional quantum electrodynamics (QED), i.e. the Schwinger Model, to investigate the HVP and HLBL. To that end, we use both tensor network techniques, specifically matrix product states, and classical emulators of digital quantum computers. Demonstrating feasibility in a simplified model, our approach sets the stage for future endeavors leveraging digital quantum computers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Entity—Hardware-agnostic Particle-in-cell Code for Plasma Astrophysics. I. Curvilinear Special Relativistic Module

Entity is a new-generation, fully open-source particle-in-cell (PIC) code developed to overcome key limitations in astrophysical plasma modeling, particularly the extreme separation of scales and the performance challenges associated with evolving, GPU-centric computing infrastructures. It achieves hardware-agnostic performance portability across various GPU and CPU architectures using the Kokkos library. Crucially, Entity maintains a high standard for usability, clarity, and customizability, offering a robust and easy-to-use framework for developing new algorithms and grid geometries, which allows extensive control without requiring edits to the core source code. This paper details the core general-coordinate special relativistic module. Entity is the first PIC code designed to solve the Vlasov–Maxwell system in general coordinates, enabling a coordinate-agnostic framework that provides the foundational structure for straightforward extension to arbitrary coordinate geometries. The core methodology achieves numerical stability by solving particle equations of motion in the global orthonormal Cartesian basis, despite using generalized coordinates like Cartesian, axisymmetric spherical, and quasi-spherical grids. Charge conservation is ensured via a specialized current deposition technique using conformal currents. The code exhibits robust scalability and performance portability on major GPU platforms (AMD MI250X, NVIDIA A100, and Intel Max Series), with the 3D particle pusher and the current deposition operating efficiently at about 2 ns per particle per time step. Functionality is validated through a comprehensive suite of standard Cartesian plasma tests and the accurate modeling of relativistic magnetospheres in curvilinear axisymmetric geometries.

Hakobyan, Hayk [Flatiron Institute, New York, NY (↗

Quantifying Uncertainty in Tortuosity Estimates for Porous Electrodes

Measuring tortuosity in porous electrodes is important for understanding rate capability and optimizing design. Here, we describe an approach to determine electrode tortuosities and quantify the associated uncertainties by fitting a P2D model to discharge profiles from a standard rate capability test. A dimensionless current is identified as a design-of-experiment parameter that can be used to identify experiments that return confident estimates of tortuosity, even when other model parameters are not known with certainty. This approach is applied to analysis of L i x V 3 O 8 (LVO) electrodes and L i x N i 0.33 M n 0.33 C o 0.33 O 2 (NMC) electrodes. The details of the assumptions made in these measurements and their impact on the reported uncertainties are discussed. We also perform an uncertainty analysis on the standard method for quantifying tortuosity in the literature: electrochemical impedance spectroscopy collected under blocking electrolyte conditions. We find that confident estimates can be obtained using this approach even when uncertainties in equivalent circuit model parameters are considered.

25 ENERGY STORAGE↗

Construction of St. Benedict

The Superallowed Transition Beta-Neutrino Decay Ion Coincidence Trap (St. Benedict) is currently under construction at the University of Notre Dame Nuclear Science Laboratory. It is designed to measure the beta-neutrino angular correlation parameter in superallowed mixed beta-decay transitions between mirror nuclei in order to extract the Fermi-to-Gamow Teller mixing ratio and test theoretical corrections entering in the determination of the V ud element of the Cabibbo–Kobayashi–Maskawa quark mixing matrix. St. Benedict includes a large volume gas catcher to thermalize the radioactive ion beam from TwinSol, a differentially-pumped extraction system, a radiofrequency quadrupole ion cooler and buncher, and a Paul trap for the observation and detection of the β decay products. Finally, the status of each of these components will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Empirically verified analysis of dual pre-cooling system for hydrogen refuelling station

The dual cooling system at the California State University Los Angeles Hydrogen Research and Fueling Facility is analysed to predict the output hydrogen temperature in different ambient conditions. Initially, the facility was built with a coil chiller T20 cooling, sufficient for occasional fuelings. A flat plate evaporator system was added in series to resolve any issues for multiple fuelings even in the hottest weather. This study was commenced to verify the set points and determine the control requirements for the dual setup in order to inform future designs. A numerical-empirical model of the cooling system was developed by reverse engineering, using the station experimental measurements and database records. The subsystems are characterized separately but validated as a whole system imposing specific and standard operating conditions. The cooling model is tested with different inputs to validate the pre-set parameter variation of the cooling components. Ten scenarios were investigated to evaluate the fueling output parameters, testing two hydrogen temperature input trends (according to the facility initial conditions) and five ambient temperatures (from 15 °C to 35 °C). In closing, the simulation results have confirmed that the hydrogen output temperature remains within the range imposed by the SAE J2601 for each scenario studied, around -22 °C and -25 °C.

08 HYDROGEN↗

Evidence of Two-Source King Plot Nonlinearity in Spectroscopic Search for New Boson

Optical precision spectroscopy of isotope shifts can be used to test for new forces beyond the standard model, and to determine basic properties of atomic nuclei. We measure isotope shifts on the highly forbidden 2 S 1/2 → 2 F 7/2 octupole transition of trapped 168,170, 172, 174, 176 Yb ions. When combined with previous measurements in Yb + and very recent measurements in Yb, the data reveal a King plot nonlinearity of up to 240σ. Furthermore, the trends exhibited by experimental data are explained by nuclear density functional theory calculations with the Fayans functional. We also find, with 4.3σ confidence, that there is a second distinct source of nonlinearity, and discuss its possible origin.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of Eco-Friendly Ionic Liquids and Commercial Bio-Derived Lubricant Additives in Terms of Tribological Performance and Aquatic Toxicity

Approximately half of the lubricants sold globally find their way into the environment. The need for Environmentally Acceptable Lubricants (EALs) is gaining increased recognition. A lubricant is composed of a base oil and multiple functional additives. The literature has been focused on EAL base oils, with much less attention given to eco-friendly additives. This study presents the tribological performance and aquatic toxicity of four short-chain phosphonium-phosphate and ammonium-phosphate ionic liquids (ILs) as candidate anti-wear and friction-reducing additives for EALs. The results are benchmarked against those of four commercial bio-derived additives. The four ILs, at a mere 0.5 wt% concentration in a synthetic ester, demonstrated a 30–40% friction reduction and >99% wear reduction, superior to the commercial baselines. More impressively, all four ILs showed significantly lower toxicity than the bio-derived products. In an EPA-standard chronic aquatic toxicity test, the sensitive model organism, Ceriodaphnia dubia, had 90–100% survival when exposed to the ILs but 0% survival in exposure to the bio-derived products at the same concentration. This study offers scientific insights for the future development of eco-friendly ILs as lubricant additives.

36 MATERIALS SCIENCE↗

Moving Beyond the Standard of Care: Accelerate Testing of Radiation-Drug Combinations

Radiation therapy is a major treatment modality used in > 60% of cancer patients as definitive local treatment for inoperable locoregionally confined tumors and as palliative therapy. Although cytotoxic chemotherapy enhances the effectiveness of treatment, the benefit over radiation therapy alone is modest. There is a need to enhance the effectiveness of local tumor control over what sequentially or concurrently administered cytotoxic chemotherapy provides. Although many biological pathways are known to enhance the effectiveness of radiation therapy, there is currently a paucity of drugs approved for use in combination. Several clinical trials have tested the effectiveness of combining targeted agents or immunotherapies with radiation therapy, but the results of these trials have been negative, likely stemming from the relative lack of preclinical evidence using appropriate experimental standardization or model systems. Accelerating the identification of agents tested in an appropriate clinical context and experimental systems or models would greatly enhance the potential to bring forward early testing of drugs that would not only be safe but also more effective. This article provides an overview of the opportunities and challenges of developing therapeutics to combine with radiation therapy, and some guidance toward preclinical and early clinical testing to improve the chance that advanced phase testing of drug-radiation combinations would be successful in the long term.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of manganese for ChemCam Mars and laboratory spectra using a multivariate model

In this work, we report a new calibration model for manganese using the laser-induced breakdown spectroscopy instrument that is part of the ChemCam instrument suite onboard the NASA Curiosity rover. The model has been trained using an expanded set of 523 manganese-bearing rock, mineral, metal ore, and synthetic standards. The optimal calibration model uses the Partial Least Squares (PLS) and Least Absolute Shrinkage and Selection Operator (LASSO) multivariate techniques, with a novel “double blending” technique. We determined the detection limit for manganese is 82 ppm using a method blank procedure and is possibly as low as 27 ppm based on visual inspection of the spectra. Based on a representative test set consisting of measurements on 93 standards, the double blended multivariate model shows a Root Mean Squared Error of Prediction (RMSEP) accuracy of 1.39 wt% MnO for the full blended model. Employing a local RMSEP estimate where the model performance is evaluated based on nearby test samples, the accuracy is 0.03 wt% at the quantification limit (0.05 wt% MnO), 0.4 wt% accuracy at 1.0 wt% MnO, and 4.4 wt% accuracy at 100 wt% MnO. Precision is estimated using the standard deviation of the test set measurements, and is ±0.01 wt% MnO at the quantification limit, ±0.09 wt% MnO at 1.0 wt% MnO, and ± 2.1 wt% MnO at 100 wt% MnO (all 1 standard deviation). This new calibration is important for understanding the variation of manganese in the bedrock with the Curiosity rover on Mars, which provides insight into past redox conditions on Mars.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Test of lepton flavor universality in semileptonic 𝐵$^+_𝑐$ meson decays in proton-proton collisions at $\sqrt{𝑠}$ = 13 TeV

A measurement of the ratio of branching fractions 𝑅⁢(𝐽/𝜓) =ℬ⁡(𝐵$^+_𝑐$ →𝐽/𝜓⁢𝜏 + ⁢𝜈 𝜏 )/ℬ⁡(𝐵$^+_𝑐$ →𝐽/𝜓⁢𝜇 + ⁢𝜈 𝜇 ) in the 𝐽/𝜓 →𝜇 + ⁢𝜇 − , 𝜏 + →𝜇 + ⁢𝜈 𝜇 ⁢$\bar{𝜈}$ 𝜏 decay channel is presented. This measurement uses a sample of proton-proton collision data collected at a center-of-mass energy of 13 TeV by the CMS experiment in 2018, corresponding to an integrated luminosity of 59.7 fb −1 . The measured ratio, 𝑅⁢(𝐽/𝜓) = 0.1⁢7$^{+0.18}_{−0.17}⁢$(stat)$^{+0.21}_{−0.22⁢}$(syst)$^{+0.19}_{−0.18}$⁢(theo) =0.17 ± 0.33, agrees with the value of 0.2582 ± 0.0038 predicted by the standard model, which assumes lepton flavor universality. By testing lepton flavor universality, this measurement is a probe of new physics using 𝐵$^+_𝑐$ mesons, which are currently only produced at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The WTP LAB stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the ANSI/HPS N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the DV of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The maximum 6 DV value from the scale model testing determines the maximum conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be = 20°. Second, the velocity uniformity at the full-scale stack must be = 20% COV. Finally, the velocity uniformity results for the actual and scale model stacks must agree within 5% COV. In general, these criteria were met through the full-scale stack tests at the LAB facility. Some specific items for each scale model and full-scale stack comparison should be noted in assessing the validity of the verification tests. The LB-C2 scale model stacks were performed with single fan operations at then-minimum flow conditions. These conditions resulted in DV values that were too low to meet the DV range criterion, and therefore are unable to be used in qualifying single fan operations on the full-scale stack. However, the single fan operations demonstrated COV values for velocity uniformity as well as flow angles that were comparable to the dual-fan operations at high flows. Overall, the test conditions and test results were within the range of acceptable values based on current design flow rates. Single fan operations are expected to only occur infrequently for maintenance needs and is therefore not a planned operating condition at this time. The LB-S1 scale model stacks were performed at three fan combinations, and in each combination, at least one test was performed at the then-minimum flow conditions as well as at then-maximum flow conditions. While the then-minimum flow conditions result in a DV range that is lower than the verification test DV value, and therefore does not meet the criterion, these tests are un-necessary for the verification test acceptance. The normal and maximum flow conditions from the scale model stack tests meet the DV range criterion, and the velocity uniformity test results compare favorably with the full-scale stack results. The LB-S2 scale model stacks were performed at nominally the same maximum flow condition; however, the 6 DV value for Fan A operation was slightly lower than the full-scale stack test DV. The COV values from the scale model stacks were comparable between the Fan A and Fan B results, and the overall test conditions are within the range of acceptable values. The stack verification is therefore considered acceptable for both Fan A and Fan B operations. The verification tests were performed at flows that were appreciably higher than the design conditions, and further elevated flow rates would be beyond the range of acceptable DV. Based on these stack verification test results, the three LAB filtered exhaust stacks meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the scale model test reports (Glissmeyer, Flaherty, and Piepel (2001), Glissmeyer and Geeting (2013)) may require additional tests and additional analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

BESTEST-GSR (Building Energy Simulation Test - Generation Simulation and Reporting) 2023 [SWR 18-23]

Building Energy Simulation Test (BESTEST) is an NREL-developed method to validate the qualitative performance of different whole building simulations engines relative to each other. https://www.nrel.gov/docs/legosti/old/6231.pdf The purpose of this repository is to generate BESTEST test case models, run simulations, and populate data for ASHRAE Standard 140 reporting spreadsheets for EnergyPlus® based whole building simulation tools. It was originally setup for 2014 version of Standard 140. In May of 2022 it was updated to the 2020 version of Standard 140. This update included updates and additions to existing test suites, the bulk of which was in Section 5.2 (Building Thermal Envelope and Fabric Load Tests). We did not add Section 5.5 Airside HVAC Equipment Performance, but we hope to add that later in 2022. At some point we also hope to add Section 5.2.4 ground modeling, which is currently excluded. Supported Tools The default IDF generation is based on the OpenStudio® CLI, but the workflow supports a 'Bring your own IDF' use case. Additionally, for non-EnergyPlus® based tools the post processing scripts can be used if simulation results are provided as a CSV file.The scripts on this repository should work on Mac, Windows, and Linux. Dependencies Install OpenStudio® 3.4.0 make sure command line can recognize the 'openstudio' command This includes EnergyPlus® 22.1 Install Ruby on your system if it isn't already setup. 2.7 is used for development but other versions may work Since OpenStudio has its own embedded Ruby, which is used for running measures, you don't necessarily have to use a version of Ruby supported by OpenStudio. Install RubyXL Ruby gem This is used to modify Microsoft Excel spreadsheets Install Parallel Ruby gem This allows the CLI to run simulations in parallel

Goldwasser, David↗

Modeling DOE Standard Canister Configurations with Updated Surface Chemistry

Road-ready and final disposition packaging configurations for the advanced test reactor (ATR) fuel currently specifies storage within helium backfilled DOE sealed standard canisters. The aluminum cladding of the ATR fuel contains an oxyhydroxide layer of boehmite/bayerite that generates hydrogen when subjected to irradiation. Understanding the effect of this hydrogen buildup over time to important for long term storage considerations. Previous modeling efforts have built a coupled CFD-chemical model to simulate the temperature gas phase concentrations within the DOE sealed standard canisters. These models have coupled the temperature conditions to both the gas phase radiolysis chemistry and the surface chemistry associated with the oxyhydroxide layer. Continued experimental work has identified trends for aluminum surrogate samples with oxyhydroxide layers for tests done at higher dose rates. At low initial doses a fast generation rate of hydrogen occurs which starts to roll over to a lower generation rate as the total dose applied in increased. A previous study created a small-scale chemical model was built to replicate a mini-canister surrogate system at SRNL as well as for the smaller capsule tests performed at INL. The previous iteration of the model utilized step function for its G-values for the hydrogen generation over a 200-year period. This model makes an update to the surface chemistry to account for theorized surface chemistry reactions allowing for oxygen to remain bounded to the oxyhydroxide layer. As additional experiments continue, the kinetic fits may be adjusted to adapt to new data. Three canister configurations are modeled – the base 18-inch, 15-foot DOR standard canister with 30 ATR fuel elements, an 18-inch, 10-foot DOE standard canister with 32 ATR fuel elements and a 24-inch, 10-foot DOE standard canister with 40 ATR fuel elements. In previous reports, the primary sensitivity of the canister conditions was identified as the decay heat of the fuel and the dried condition of the fuel. Only these parameters are studied in the report. For the nominal case with dried fuel, the hydrogen generation is only about 2%, so it is even less than the flammability limit if it were exposed to oxygen. For the densely packed 18-inch case the total hydrogen concentration is only around 4% with the nominal decay heat. For the densely packed 24-inch case the total hydrogen concentration is only 2.5%, roughly 20% higher than the original packing design, and still under flammability conditions if exposed to oxygen.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Question-answering system extracts information on injection drug use from clinical notes

Background. Injection drug use (IDU) can increase mortality and morbidity. Therefore, identifying IDU early and initiating harm reduction interventions can benefit individuals at risk. However, extracting IDU behaviors from patients’ electronic health records (EHR) is difficult because there is no other structured data available, such as International Classification of Disease (ICD) codes, and IDU is most often documented in unstructured free-text clinical notes. Although natural language processing can efficiently extract this information from unstructured data, there are no validated tools. Methods. Here, to address this gap in clinical information, we design a question-answering (QA) framework to extract information on IDU from clinical notes for use in clinical operations. Our framework involves two main steps: (1) generating a gold-standard QA dataset and (2) developing and testing the QA model. We use 2323 clinical notes of 1145 patients curated from the US Department of Veterans Affairs (VA) Corporate Data Warehouse to construct the gold-standard dataset for developing and evaluating the QA model. We also demonstrate the QA model’s ability to extract IDU-related information from temporally out-of-distribution data. Results. Here, we show that for a strict match between gold-standard and predicted answers, the QA model achieves a 51.65% F1 score. For a relaxed match between the gold-standard and predicted answers, the QA model obtains a 78.03% F1 score, along with 85.38% Precision and 79.02% Recall scores. Moreover, the QA model demonstrates consistent performance when subjected to temporally out-of-distribution data. Conclusions. Our study introduces a QA framework designed to extract IDU information from clinical notes, aiming to enhance the accurate and efficient detection of people who inject drugs, extract relevant information, and ultimately facilitate informed patient care.

60 APPLIED LIFE SCIENCES↗

Fiducial and differential cross-section measurements of electroweak $W\gamma jj$ production in $pp$ collisions at $\sqrt{s} = 13$ TeV with the ATLAS detector

The observation of the electroweak production of a W boson and a photon in association with two jets, using pp collision data at the Large Hadron Collider at a centre of mass energy of $\sqrt{s} = 13$ TeV, is reported. The data were recorded by the ATLAS experiment from 2015 to 2018 and correspond to an integrated luminosity of 140 fb -1 . This process is sensitive to the quartic gauge boson couplings via the vector boson scattering mechanism and provides a stringent test of the electroweak sector of the Standard Model. Events are selected if they contain one electron or muon, missing transverse momentum, at least one photon, and two jets. Multivariate techniques are used to distinguish the electroweak $W\gamma jj$ process from irreducible background processes. The observed significance of the electroweak $W\gamma jj$ process is well above six standard deviations, compared to an expected significance of 6.3 standard deviations. Fiducial and differential cross sections are measured in a fiducial phase space close to the detector acceptance, which are in reasonable agreement with leading order Standard Model predictions from MADGRAPH5+PYTHIA8 and SHERPA. The results are used to constrain new physics effects in the context of an effective field theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Additively Manufactured Carbon Fiber and Fused Deposition Modeling PLA Interlaminar Shear Testing Report

This test report summarizes the torsional test setup, procedure, and results for interlaminar shear (ILS) failure of additively manufactured carbon fiber (CFAM) material developed at LLNL. In addition, the report also includes testing of fused deposition modeled (FDM) polylactic acid (PLA), including ILS test standard D7078 and the same torsional test mentioned above. The test hopes to characterize ILS properties of CFAM, however substantial further testing and improvements still need to be done to induce a proper failure mode. This testing was performed by Sundi Win as part of her summer internship project in Kinetic Technologies.

36 MATERIALS SCIENCE↗