Search NASA⌕ Search

SEARCH · Search NASA

Results for “static testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Evaluation of Low Dose Silicon Carbide Temperature Monitors

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at materials and test reactors. Melt wires or paint spots are often included in such tests as an independent technique of detecting peak temperatures incurred during irradiation. In addition, less expensive static capsule tests, which have no leads attached for real-time data transmission, often rely on melt wires and paint spots as a post-irradiation technique for peak temperature indication. Unfortunately, these techniques are limited in that they can only detect whether a single temperature is or is not exceeded. Silicon carbide (SiC) monitors are advantageous because a single monitor can be used to determine the peak temperature reached within a relatively broad range (200 – 800°C). Although the use of SiC monitors was proposed more than five decades ago, the ultimate performance limits of this technique are not fully understood. The Nuclear Science User Facilities (NSUF) is the United States Department of Energy Office of Nuclear Energy's only designated nuclear energy user facility. Its mission is to provide nuclear energy researchers access to world-class capabilities and to facilitate the advancement of nuclear science and technology. This mission is supported by providing access to state-of-the-art experimental irradiation testing, post irradiation examination facilities, and high performance computing capabilities as well as technical and scientific assistance for the design and execution of projects. As part of an NSUF project, low dose silicon carbide monitors were irradiated in the Belgian Reactor 2 and were then evaluated both at the SCK•CEN and at Idaho National Laboratory's High Temperature Test Laboratory to determine their peak temperature achieved during irradiation. The technical significance of this work was that the monitors were irradiated to a dose that was significantly less than recommended in published literature. This paper will discuss the evaluation process, the irradiation test, and the performance of the low dose silicon carbide temperature monitors.

36 MATERIALS SCIENCE↗

Silicon Carbide Temperature Monitor Processing Improvements. Status Report

Silicon carbide (SiC) temperature monitors are used as temperature sensors in Advanced Test Reactor (ATR) irradiations at the Idaho National Laboratory (INL). Although thermocouples are typically used to provide real-time temperature indication in instrumented lead tests, other indicators, such as melt wires, are also often included in such tests as an independent technique of detecting peak temperatures incurred during irradiation. In addition, less expensive static capsule tests, which have no leads attached for real-time data transmission, often rely on melt wires as a post-irradiation technique for peak temperature indication. Melt wires are limited in that they can only detect whether a single temperature is or is not exceeded. SiC monitors are advantageous because a single monitor can be used to detect for a range of temperatures that occurred during irradiation. As part of the process initiated to make SiC temperature monitors available at the ATR, post-irradiation evaluations of these monitors have been previously completed at the High Temperature Test Laboratory (HTTL). INL selected the resistance measurement approach for determining irradiation temperature from SiC temperature monitors because it is considered to be the most accurate measurement. The current process involves the repeated annealing of the SiC monitors at incrementally increasing temperature, with resistivity measurements made between annealing steps. The process is time consuming and requires the nearly constant attention of a trained staff member. In addition to the expensive and lengthy post analysis required, the current process adds many potential sources of error in the measurement, as the sensor must be repeatedly moved from furnace to test fixture. This time-consuming post irradiation analysis is a significant portion of the total cost of using these otherwise inexpensive sensors. An additional consideration of this research is that, if the SiC post processing can be automated, it could be performed in an MFC hot cell, further reducing the time and expense of lengthy decontaminations prior to processing. Sections of this report provide a general description of resistivity techniques currently used to infer peak irradiation temperature from silicon carbide temperature monitors along with some representative data, the proposed concepts to improve the process of analyzing irradiated SiC temperature monitors, the completed efforts to prove the proposed concepts, and future activities. The efforts detailed here succeeded in designing and developing a real-time automated SiC resistivity measurement system, and performed two initial test runs. Activities carried out include the assembly and integration of the system hardware; the design and development of a preliminary monitor fixture; the design of a technique to automate the data analysis and processing; the development of the communication, coordination, and user software; and the execution and troubleshooting of test run experiments using the box furnace. Although the automation system performed as required, the designed fixture did not succeed in establishing the needed electrical contacts with the SiC monitor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OC6 Project Phase IV: Validation of Numerical Models for Novel Floating Offshore Wind Support Structures

The fourth phase of the Offshore Code Comparison, Collaboration, Continued, with Correlation and unCertainty (OC6) aims to assess the ability of the tools to model a novel floating wind design. The design that was selected for this project is the TetraSpar designed by Stiesdal Offshore Technologies. The platform is a unique design that features a spar like stability with a very low center of gravity, but does not require deep-water ports. This combination is achieved with a system made of two separate steel structures, a hull at the water’s surface that supports the wind turbine tower, and a keel that is suspended below the main body. This lower keel has a very high density and drives the total platform’s low center of gravity. Scaled model tests of the TetraSpar design were performed in 2018-2019 by the University of Maine. The tests were performed with 1:43 Froude scaling. The data collected in the model tests provide a detailed description of the response of the platform in various controlled and relatively well understood conditions. Comparison with these data provides a good opportunity for validation of numerical models. The OC6 Phase IV work will focus on the specific parameters used in these scaled model tests. The load cases (LC) considered in this project are as follows: LC 1.X - Equilibrium and Static Offset Tests LC 2.X - Platform Free Decays LC 3.X - Turbine Thrust (Wind Only) LC 4.X - Regular and Irregular Waves (Wave only) LC 5.X - Combined Wind and Wave Loading

17 WIND ENERGY↗

Active optics null test system based on a liquid crystal programmable spatial light modulator

We present an active null test system adapted to test lenses and wavefronts with complex shapes and strong local deformations. This system provides greater flexibility than conventional static null tests that match only a precisely positioned, individual wavefront. The system is based on a cylindrical Shack-Hartmann wavefront sensor, a commercial liquid crystal programmable phase modulator (PPM), which acts as the active null corrector, enabling the compensation of large strokes with high fidelity in a single iteration, and a spatial filter to remove unmodulated light when steep phase changes are compensated. We have evaluated the PPM's phase response at 635 nm and checked its performance by measuring its capability to generate different amounts of defocus aberration, finding root mean squared errors below {lambda}/18 for spherical wavefronts with peak-to-valley heights of up to 78.7{lambda}, which stands as the limit from which diffractive artifacts created by the PPM have been found to be critical under no spatial filtering. Results of a null test for a complex lens (an ophthalmic customized progressive addition lens) are presented and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Corrosion Assessment of Candidate Materials for the SHINE Subcritical Assembly Vessel and Components—FY14 Report

Laboratory corrosion testing of candidate alloys—including Zr-4 and Zr-2.5Nb representing the target solution vessel, and 316L, 2304, 304L, and 17-4 PH stainless steels representing process piping and balance-of-plant components—was performed in support of the proposed SHINE process to produce 99 Mo from low-enriched uranium. The test solutions used depleted uranyl sulfate in various concentrations and incorporated a range of temperatures, excess sulfuric acid concentrations, nitric acid additions (to simulate radiolysis product generation), and iodine additions. Testing involved static immersion of coupons in solution and in the vapor above the solution, and was extended to include planned-interval tests to examine details associated with stainless steel corrosion in environments containing iodine species. A large number of galvanic tests featuring couples between a stainless steel and a zirconium-based alloy were performed, and limited vibratory horn testing was incorporated to explore potential erosion/corrosion features of compatibility. In all cases, corrosion of the zirconium alloys was observed to be minimal, with corrosion rates based on weight loss calculated to be less than 0.1 mil/year with no change in surface roughness. The resulting passive film appeared to be ZrO 2 with variations in thickness that influence apparent coloration (toward light brown for thicker films). Galvanic coupling with various stainless steels in selected exposures had no discernable effect on appearance, surface roughness, or corrosion rate. Erosion/corrosion behavior was the same for zirconium alloys in uranyl sulfate solutions and in sodium sulfate solutions adjusted to a similar pH, suggesting there was no negative effect of uranium resulting from fluid dynamic conditions aggressive to the passive film. Corrosion of the candidate stainless steels was similarly modest across the entire range of exposures. However, some sensitivity to corrosion of the stainless steels was observed in solutions with 50 wppm iodine (the actual SHINE process expects 0.1–1 wppm) with the highest corrosion rates (up to ~6 mil/year) observed on specimens exposed in the vapor phase. Lower concentrations of iodine species (5 or 28 wppm) proved much less corrosive, and the planned-interval data indicated that metal corrodibility decreased with time for all immersed exposures and, with one minor exception, all vapor exposures. Little change in susceptibility to corrosion was observed as a result of nitric acid additions to the test environment (simulating radiolysis products). The trend toward reduced corrosion (immersion and vapor phase) with decreasing iodine concentration suggests that, at the expected conditions in the SHINE process, it is unlikely that iodine species will generate a general corrosion concern for the candidate stainless steels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Named Data Networking for DER Cybersecurity

We present our research findings on the novel NDN protocol. In this work, we defined key attack scenarios for possible exploitation and detail software security testing procedures to evaluate the security of the NDN software. This work was done in the context of distributed energy resources (DER). The software security testing included an execution of unit tests and static code analyses to better understand the software rigor and the security that has been implemented. The results from the penetration testing are presented. Recommendations are discussed to provide additional defense for secure end-to-end NDN communications.

97 MATHEMATICS AND COMPUTING↗

Rotational flexural strength of cylindrical brittle specimens

Conventional static flexural strength testing of brittle cylindrical rods only subjects a small fraction of the entire specimen's area or volume to the maximum tensile stress. Thus, a nonconservative measured strength likely results since most flaws on the surface or in the bulk are not subjected to a sufficiently high tensile stress that can cause fracture. Here, to mitigate this, a rotational flexural tester and corresponding test method were developed whereby rotation and monotonically increasing three-point flexure were superimposed to investigate fracture response of solid glass cylinders. This combination of rotation and flexure subjects more area and volume of a cylindrical test specimen to tensile stress than a standard static (nonrotating) flexural test. As anticipated, failure stresses were lower for the rotational flexural test. Expressions for effective area and volume are provided for rotating solid rods and tubes subjected to three-point, four-point, uniform, and uniformly distributed load bending configurations.

36 MATERIALS SCIENCE↗

Effect of the Processing-Induced Morphology on the Mechanical Properties of Biodegradable Extruded Films Based on Poly(lactic acid) (PLA) Blends

Biodegradable films based on poly(lactic acid) blends were obtained by cast extrusion. Their tensile and fracture behavior was investigated and the effect of the processing conditions through the extrusion rolling speed on this behavior was analyzed. In uniaxial tensile tests, all films presented completely ductile behavior exhibiting a defined yield point, strain softening after this point and a plateau before fracture. Fracture behavior was determined through quasi-static fracture tests on deeply double edge notched tensile specimens. The film obtained at the lowest rolling speed exhibited completely ductile behavior hence, the Essential Work of Fracture methodology was applied to characterize its fracture. The film processed at intermediate rolling speed, on the other hand, presented ductile fracture or ductile instability depending on the ligament length and the film obtained with the highest rolling speed exhibited a transition regime fracture. In order to compare the fracture behavior of the different films, the J-integral at maximum load J{sub max} was adopted. Differences in the films fracture behavior were correlated to the processing-induced morphology.

36 MATERIALS SCIENCE↗

MO-F-16A-01: Implementation of MPPG TPS Verification Tests On Various Accelerators

Purpose: To demonstrate the implementation of the Medical Physics Practice Guideline (MPPG) for dose calculation and beam parameters verification of treatment planning systems (TPS). Methods: We implemented the draft TPS MPPG for three linacs: Varian Trilogy, TomoHDA and Elekta Infinity. Static and modulated test plans were created. The static fields are different than used in commissioning. Data was collected using ion chambers and diodes in a scanning water tank, Delta4 phantom and a custom phantom. MatLab and Microsoft Excel were used to create analysis tools to compare reference DICOM dose with scan data. This custom code allowed for the interpolation, registration and gamma analysis of arbitrary dose profiles. It will be provided as open source code. IMRT fields were validated with Delta4 registration and comparison tools. The time for each task was recorded. Results: The tests confirmed the strengths, and revealed some limitations, of our TPS. The agreement between calculated and measured dose was reported for all beams. For static fields, percent depth dose and profiles were analyzed with criteria in the draft MPPG. The results reveal areas of slight mismatch with the model (MLC leaf penumbra, buildup region.) For TomoTherapy, the IMRT plan 2%/2 mm gamma analysis revealed poorest agreement in the low dose regions. For one static test plan for all 10MV Trilogy photon beams, the plan generation, scan queue creation, data collection, data analysis and report took 2 hours, excluding tank setup. Conclusions: We have demonstrated the implementation feasibility of the TPS MPPG. This exercise generated an open source tool for dose comparisons between scan data and DICOM dose data. An easily reproducible and efficient infrastructure with streamlined data collection was created for repeatable robust testing of the TPS. The tests revealed minor discrepancies in our models and areas for improvement that are being investigated.

07 ISOTOPE AND RADIATION SOURCES↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of Cast U-6Nb Sprue

Shape casting of uranium-6 wt. pct. niobium (U-6Nb) can produce near net shape components, providing a higher efficiency alternative to wrought processing. A substantial amount of materials characterization in support of direct casting process development has been performed and documented. This supplemental work describes the mechanical behavior of the hot top region of shape cast U-6Nb in order to determine and quantify the effect of casting defects, such as gas porosity and inclusions, on U-6Nb performance. The annular hot top region of a hollow cylindrical casting was sectioned and metallographic, bend, and tensile specimen blanks were machined from various locations around the part. Porosity ranging from 5-13% was observed, depending on the region sampled (i.e. top, bottom or outer portion of casting). Optical and scanning electron microscopy showed prior gamma grain size ranging from <10 up to 300 μm. There are uranium oxide and carbide inclusions present at the 50-150 μm size range; these were identified based on their morphology and color. Martensitic herringbone twinning and a lamellar structure was observed as well as what may be platelets of retained $γ$° in a matrix of $α$". The tensile test specimens were lathe machined and subjected to a low temperature artificial aging heat treatment consisting of a hold at 200°C for 2 hours, followed by furnace cooling in a helium atmosphere. Quasi-static mechanical tests showed a ductile void coalescence fracture mode with failure strains from 2-16% and a linear increase in stress up to approximately 400 MPa. Prior studies on low porosity regions sampled from a similar casting reported a failure strain of 15-21% in the artificially aged condition. The significant loss in ductility in the hot top region is attributed to increased porosity.

36 MATERIALS SCIENCE↗

Control of molten salt corrosion of fusion structural materials by metallic beryllium

A series of tests have been performed between 2001 and 2006 at the Safety and Tritium Applied Research facility of the Idaho National Laboratory to demonstrate chemical compatibility between the molten salt flibe (2LiF+BeF2 in moles) and fusion structural materials once suitable fluoride potential control methods are established. The tests adopted metallic beryllium contact as main fluoride potential control, and the results have been published in recent years. A further step was to expose two specimens of low activation ferritic/martensitic steel 9Cr-2W to static corrosion tests that include an active corrosion agent (hydrofluoric gas) in controlled conditions at 530 C, and the results of the tests are presented in this paper. The results confirmed the expected correlation of the HF recovery with the concentration of metallic impurities dissolved in the salt because of specimen corrosion. The metals concentration dropped to level close to the detectable limit when the beryllium rod was inserted and increased once the content of excess beryllium in the system had been consumed by HF reduction and specimens corrosion progressed. Metallographic analysis of the samples after 500 hours exposure in reactive conditions showed evidence of the formation of unstable chromium oxide layers on the specimens surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Summary report for the FY-2015 SACSESS Collaboration

During FY-2015, a collaborative research program was established by the Department of Energy-Nuclear Energy (DOE-NE) Material Recovery and Waste Form Development program and the European Union (EU) Safety of Actinide Separation Processes (SACSESS) program. One component of this collaboration was the evaluation of the radiolytic stability of a Selective ActiNide Extraction (SANEX) separation which utilized a TODGA-based organic solvent and an aqueous phase containing the hydrophilic complexing reagent, SO3-Ph-BTP. To best simulate process conditions, this experiment was irradiated in the radiolysis/hydrolysis test loop located at the Idaho National Laboratory. The effect of irradiation on a SACSESS program iSANEX formulation containing a TODGA-based organic phase and a BTP-based aqueous phase was investigated using irradiations at INL in static and test loop modes. When irradiated in contact with only the acidic aqueous phase, the TODGA organic solution maintained excellent extraction performance of americium, cerium and europium to a maximum absorbed dose of nearly 0.9 MGy. When the aqueous phase was changed to that containing the aqueous soluble BTP, the irradiated aqueous phase showed a dramatic color change, but this does not appear to have adverse effects on solvent extraction performance. Only minor increases in distribution ratios for both the lanthanides and actinide were measured, and the separation factors were essentially unchanged to a maximum absorbed dose of 174 kGy. The determination of the americium, cerium, and europium distribution ratios for the remaining SACSESS test loop samples will be completed in the near future. The analysis of stable metals concentration in the the irradiated aqueous and organic phases will be completed shortly.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of vascularization-­inducing hydrogel bioinks for 3D bioprinting

This study seeks to validate the reproducibility of previous bioprinting work at Lawrence Livermore National Laboratory (LLNL) on a new Aerotech motion controller system and to modify an existing bioink, fibrin, by adding varying percent volumes of hyaluronic acid (HA). Endothelial and fibroblast cells bioprinted in fibrin gels using the Aerotech system were confirmed to be more than 77 percent viable after one day, and all bioprinted samples retained sterility after one week of culture. To characterize cell behavior in fibrin with HA addition, static co-­culture gels with varying percent volumes of HA were cultured in vitro for one week. Resulting confocal microscope images showed increased cell network formation in all concentrations of HA compared to the control (no HA), and rheological tests mimicking static gel compositions displayed positive correlations between gelation time, gel stiffness (G’), and hyaluronic acid concentration. Although the current data is insufficient to quantitatively associate HA concentration with the level of cell vascularization, future work will aim to develop a targeted HA concentration in fibrin for maximum cell network formation, to optimize the printing process parameters for this new bioink composition, and to analyze cell viability in bioprinted fibrin-­HA structures.

42 ENGINEERING↗

Novel Self-Thickening Chemicals for Improved Conformance Control

The objective of this project is to identify single chemical agents that exhibit a desirable rheological property whereby if such a chemical is dissolved in salt water it increases the solution viscosity significantly with time. We term that behavior as 'self-thickening' and have nicknamed this as 'T85 technology'. As detailed in the original project proposal, such single chemical products can be applied to advantage as agents for selectively slowing or blocking high flow water channels in subsurface oil reservoirs. The net effect is a decrease in water and an increase in oil flow and production. The initial testing has focused on five different synthetic co-polymers that have two or more chemical groups. These chemicals were dissolved at a concentration of 2500 ppm into different salt solutions (sodium chloride, potassium chloride, and calcium chloride) that encompass a range of dissolved salt concentrations. For the sodium chloride and potassium chloride solutions the salt concentration ranged from 1-5 wt%. The calcium chloride dihydrate sample concentrations ranged from 0.1-1 wt%. One set of samples being aged at 25 C and a second set at 50 C. Viscosity measurements versus aging time show two of these agents may exhibit apparent self-thickening behavior under certain salinity and temperature conditions. Generally the effect is greater in lower salinity NaCl brines and at 25 C. Preliminary flow experiments confirm that the aged fluids exhibit increased effective viscosity while flowing through a porous medium (sand pack). These flow tests include the case of the chemical fluid being aged on the bench before injection into a sand pack, and also a second series of sand packs where fresh chemical fluid is injected and allowed to age in-situ. Thus, the results of the static ageing tests together with the flow tests are a technical validation of the T85 concept.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser Welded Edge Seals for Polymer-Free Glass/Glass Modules

This presentation covers fs lasers which enable crack-free and stress-free glass/glass welds. Welds are nearly as strong as the glass (KI, weld ~ KI, glass) and static load test passed, enabling: 1) polymer-free; 2) hermetically sealed; and 3) recyclable modules. Next steps are: 1) follow-on funding; 2) develop feed throughs (metal/glass welds already achieved for other devices); and 3) weld mini modules for further IEC module testing.

DuraMAT↗

Phenylnaphthalene as a Heat Transfer Fluid for Concentrating Solar Power: High-Temperature Static Experiments

Concentrating solar power (CSP) may be an alternative to generating electricity from fossil fuels; however, greater thermodynamic efficiency is needed to improve the economics of CSP operation. One way of achieving improved efficiency is to operate the CSP loop at higher temperatures than the current maximum of about 400 C. ORNL has been investigating a synthetic polyaromatic oil for use in a trough type CSP collector, to temperatures up to 500 C. The oil was chosen because of its thermal stability and calculated low vapor and critical pressures. The oil has been synthesized using a Suzuki coupling mechanism and has been tested in static heating experiments. Analysis has been conducted on the oil after heating and suggests that there may be some isomerization taking place at 450 C, but the fluid appears to remain stable above that temperature. Tests were conducted over one week and further tests are planned to investigate stabilities after heating for months and in flow configurations. Thermochemical data and thermophysical predictions indicate that substituted polyaromatic hydrocarbons may be useful for applications that run at higher temperatures than possible with commercial fluids such as Therminol-VP1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Acceleration of Glass Alteration Rates Induced by Zeolite Seeds at Controlled pH

As the glass-water reaction proceeds, certain glass compositions undergo a delayed acceleration in the alteration rate – a phenomenon that is commonly referred to as Stage III behavior – which generally coincides with zeolite formation. However, studying Stage III in the laboratory is difficult because the time scale required to observe Stage III behavior can vary from months to several years, and the solution conditions that initiate this acceleration remain poorly understood. Consequently, the development of a corrosion test method capable of quantifying Stage III rates in a timely manner would be of great benefit to both the scientific community and policy makers concerned with nuclear waste disposal. In this work, we induced and measured the acceleration in the corrosion rate of the AFCI glass by seeding static corrosion tests with zeolite Na-P2 at fixed pH90°C values ranging from 9.5 to 11.5. The induced Stage III rates increased linearly with increasing pH and were measured to be between the forward and residual rates of AFCI. Tests designed to compare induced Stage III rates obtained for different seeding times showed that the induced Stage III rates were faster in the absence of an alteration layer. In summary, the use of the seeded test method allows for a conservative quantification of Stage III rates in a relatively short, one-month time period.

Neeway, James J.↗