Search NASA⌕ Search

SEARCH · Search NASA

Results for “stopping rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Ambient temperature fatigue tests of elements of an actively cooled honeycomb sandwich structural panel

Elements of an actively cooled structural panel for a hypersonic aircraft have been investigated for fatigue characteristics. The study involved a bonded honeycomb sandwich panel with d-shaped coolant tubes. The curved portion of these tubes was embedded in the honeycomb, and the flat portion was bonded or soldered to the inner surface of the outer skin. The elements examined were two plain skin specimens (aluminum alloy); two specimens with skins attached to manifolds and tubes (one specimen was bonded, the other soldered); and a specimen representative of a corner section of the complete cooled sandwich. Sinusoidal loads were applied to all specimens. The honeycomb sandwich specimen was loaded in both tension and compression; the other specimens were loaded in tension only. The cooling tubes were pressurized with oil throughout the fatigue tests. The most significant results of these tests follow: All specimens exceeded their design life of 20,000 cycles without damage. Crack growth rates obtained in the plain skin specimens were used to determine the crack growth characteristics of aluminum alloy. Cracks in skins either bonded or soldered to cooling tubes propagated past the tubes without penetration. The coolant tubes served as crack arresters and temporarily stopped crack growth when a crack reached a tube-skin interface. The honeycomb core demonstrated that it could contain leakage from a tube.

Sharpe, E. L.↗

Low-Pressure-Drop Shutoff Valve

Flapper valve remains open under normal flow conditions but closes upon sudden increases to high rate of flow and remains closed until reset. Valve is fluid/mechanical analog of electrical fuse or circuit breaker. Low-pressure-drop shutoff valve contains flapper machined from cylindrical surface. During normal flow conditions, flapper presents small cross section to flow. (Useful in stopping loss of fluid through leaks in cooling systems.)

Thornborrow, John↗

NASA's extended duration orbiter medical program

The physiological issues involved in safely extending Shuttle flights from 10 to 16 days have been viewed by some as academic. After all, they reasoned, humans already have lived and worked in space for periods exceeding even 28 days in the United States Skylab Program and onboard the Russian space stations. The difference in the Shuttle program is in the physical position of the astronauts as they reenter the Earth's atmosphere. Crewmembers in the earlier Apollo, Skylab, and Russian programs were returned to Earth in the supine position. Space Shuttle crewmembers, in contrast, are seated upright during reentry and landing; reexperiencing the Earth's g forces in this position has far more pronounced effects on the crewmember's physiological functions. The goal of the Extended Duration Orbiter (EDO) Medical Project (EDOMP) has been to ensure that crewmembers maintain physiological reserves sufficient to perform entry, landing, and egress safely. Early in the Shuttle Program, it became clear that physiological deconditioning during space flight could produce significant symptoms upon return to Earth. The signs and symptoms observed during the entry, landing, and egress after Shuttle missions have included very high heart rates and low blood pressures upon standing. Dizziness, 'graying out,' and fainting have occurred on ambulation or shortly thereafter. Other symptoms at landing have included headache, light-headedness, nausea and vomitting, leg cramping, inability to stand for several minutes after wheel-stop, and unsteadiness of gait.

Pool, Sam Lee↗

Analytic expression for the energy-transfer rate from photoelectrons to thermal-electrons.

An analytic form is given for the energy-transfer rate from photoelectrons to thermal electrons. The expression fits the classical formulation of Itakawa and Aono (1966) at low energies and gives a smooth transition to fit the quantum mechanical equation of Schunk and Hays (1971) at higher energies. The corresponding loss function or stopping power has a form that is convenient in auroral and dayglow calculations.

Swartz, W. E.↗

Parasitic instabilities in magnetized, differentially rotating disks

Velikhov, Chandrasekhar, Balbus & Hawley have discovered a MHD instability of differentially rotating fluids that may explain the effective viscosity of accretion disks. If the unperturbed magnetic energy density is much less than the gas pressure, this `magnetorotational' instability (MRI) arises on small scales and is approximately incompressible. If the unperturbed field is suffiently, strong, the MRI is suppressed. We therefore ask whether the MRI mechanism can amplify even very weak initial fields until they reach equipartition with the gas pressure. We show that in the total incompressible limit, the MRI modes are exact solutions of the nonlinear fluid equations, even if the perturbed magnetic field is much larger than the unperturbed field. Also, we present a new exact solution in the opposite limit that the magnetic pressure is much larger than that of the gas. On the other hand, we show that the incompressible MRI modes are themselves subject to parasitic instabilities with instantaneous growth rates proportional to the MRI amplitude. Some of the parasitic instabilities are of the Kelvin-Helmholtz type, while others are less familiar. The eigenfunctions of the latter group suggest that they may promote rapid reconnection of the MRI field. Thus, parasitic modes may stop MRI growth at subequipartition amplitudes if it developes from a sufficiently weak initital field.

Goodman, Jeremy↗

Performance of the GLAS Space Lidar Receiver Through Its Seven-Year Space Mission

NASA s Ice, Cloud, and land Elevation Satellite (ICESat) mission [1,2] carrying the Geoscience Laser Altimeter System (GLAS) Instrument, was launched on January 12, 2003. The three lasers on ICESat have made a total of 1.98 billion laser shot measurements of the Earth s surface and atmosphere during its 17 science data collection campaigns over its seven year operating lifetime. ICESat completed its science mission after the last laser stopped operating in October 2009. The spacecraft was de-orbited on August 30, 2010. The GLAS instrument carried 3 diode-pumped Q-switched Nd:YAG lasers, which emitted 6-nsec wide pulses at 1064 and 532 nm at a 40-Hz rate. There are three lidar receiver channels, a 1064 nm surface altimetry channel, a 1064 nm cloud backscattering lidar channel, and a 532 nm cloud and aerosol backscattering lidar channel. The altimetry and cloud backscatter channels used Si avalanche photodiode (APD) operated in analog mode as in the Mars Global Surveyor s Mars Orbital Laser Altimeter [3,4]. GLAS also utilized a number of new technologies and techniques for space lidar, including passively Q-switched diode-pumped Nd:YAG lasers, a 1-m diameter telescope, a temperature tuned etalon optical bandpass filter, Si APD single photon counting detectors, 1 Gsample/sec waveform digitizers, ultra stable clock oscillators, and digital signal processing and detection algorithms [5]. A global position system (GPS) receiver was used to provide the spacecraft position and epoch times. The ICESat mission provided a unique opportunity to monitor the lidar component performance in the space environment over a multi-year time period. We performed a number of engineering tests periodically to monitor the lidar receiver performance, including receiver sensitivity, timing precision, detector dark noise, etc. A series of engineering tests were also performed after the end of the science mission to evaluate the performance of the spare detector, oscillator, waveform digitizer, and GPS receiver. An experiment was conducted which pointed GLAS to Venus to test the receiver sensitivity to star light and to verify GLAS bore sight with respect to the spacecraft coordinate system. These tests provided unique data to assess the degradation and the rate of change of these key lidar components due to space radiation and aging. They also helped to validate new techniques to operate and calibrate future space lidars.

Sun, Xiaoli↗

Laser balancing demonstration on a high-speed flexible rotor

This paper describes a flexible rotor system used for two-plane laser balancing and an experimental demonstration of the laser material removal method for balancing. A laboratory test rotor was modified to accept balancing corrections using a laser metal removal method while the rotor is at operating speed. The laser setup hardware required to balance the rotor using two correction planes is described. The test rig optical configuration and a neodymium glass laser were assembled and calibrated for material removal rates. Rotor amplitudes before and after balancing, trial and correction weights, rotor speed during operation of laser, and balancing time were documented. The rotor was balanced through the first bending critical speed using the laser material removal procedure to apply trial weights and correction weights without stopping the rotor.

Demuth, R. S.↗

Clock synchronization experiments performed via the ATS-1 and ATS-3 satellites.

Clock synchronization experiments were carried out May 10 to June 10, 1971, via the ATS-1 and ATS-3 geostationary satellites between the NASA tracking stations at Rosman, N.C., and Mojave, Calif., in order to determine the offset and the relative drift rate between the two station clocks. Pulses at C band with very sharp risetime and of 10 microsec duration were exchanged by the two stations through the dual transponders of the satellites. At each station, a time-interval counter was started by the transmitted pulse and stopped by the pulse received via satellite from the other station. The probable error of the clock offset as measured by the counter is 10 msec. A very long baseline interferometer experiment was also performed between the two stations at the same time and provided independent clock-offset data to check the accuracy of the time-synchronization experiment.

Ramasastry, J.↗

Stopping of 200-GeV gold nuclei in nuclear emulsions

The residual ranges of Au-197(79) nuclei stopping in nuclear emulsions has been measured for nuclei with an incident energy of 991 MeV/amu. The mean ranges observed are appreciably less than those predicted from measurements made on energetic particles of lower charge. However, by the consideration of higher-order correction terms to the rate of energy loss, good agreement can be obtained between the predicted and observed ranges.

Waddington, C.J.↗

Maintaining Restored Bone with Bisphoshonate in the Ovariectomized Rat Skeleton: Dynamic Histomorphometry of Changes in Bone Mass

This experiment contains the crucial data for the Lose, Restore and Maintain (LRM) concept, a practical approach for reversing existing osteoporosis. The LRM concept uses ovariectomy (ox) to lose bone, an anabolic agent to restore bone mass and then switches to an anti-resorptive agent to maintain bone mass. We ox'd or sham-ox'd rats for 150 days (Loss Phase), treated them with 6 mg PGE2/kg/d for 75 days to restore lost cancellous bone mass (Restore Phase) and then stopped PGE2 treatment and began treatment with 1 or 5 micro-g/kg Risedronate, a bisphosphonate twice a week for 60 days (Maintain Phase). During the Loss Phase, cancellous bone volumes of the proximal tibial metaphysis (PTM) in the ox'd rat fell to 19% of initial controls. During the Restore Phase, the PTM bone volume in ox'd rats doubled. However, when PGE2 treatment was stopped, the PGE2-induced cancellous bone disappeared. In contrast, 5 micro-g of Risedronate inhibited the bone loss and maintained it at the PGE2 treatment level. The key dynamic histomorphometry value for the restore (R) and maintenance (M) phases was the ratio of bone formation to resorption rates. The ratio was elevated to 5.8 in the R phase and depressed to 0.4 for no and 1 micro-g Risedronate treated M phase and to a ratio of near unity of 1.1 for the 5 micro-g Risedronate treatment. These findings indicate that we were successful in maintaining the new PTM bone induced by PGE2 after discontinuing PGE2 by administering enough Risedronate, a resorption inhibitor. We concluded that the LRM concept is correct and such an approach should be considered when employing anabolic agents or growth factors in the treatment of osteoporosis. Continued use of an anabolic agent may not be appropriate because of cost, potential adverse side effects and a loss of efficacy.

Jee, W. S. S.↗

Gender Differences in Cardiovascular Tolerance to Short Arm Centrifugation

In preparation for the NASA Artificial Gravity (AG) pilot study, the tolerability of the proposed AG parameters was tested in 11 ambulatory human subjects (6m, 5w) by exposing each to a short arm centrifuge trial. Subjects were oriented in the supine position (but inclined 6deg head down) on one arm of the centrifuge, and the rotation rate (30.6-33.4 rpm) and radial position of the feet were set to produce 2.5G of equivalent gravitational load at the force plate directly beneath the feet, 1G at the level of the mediastinum, and approximately 0.55G at the labyrinth. Amongst the 6 men participating in this preliminary study, 5 completed at least 60 minutes of the trial successfully with no adverse sequelae. However, amongst the female cohort the test was stopped by the medical monitor before 60 min in all but one case, with pre-syncope listed as the reason for termination in all cases. Mean time before abort of the centrifuge run amongst the women was 33.2 +/- 20.97 min. It is known that women have a greater predisposition to syncope during orthostatic stress, under normal tilt table conditions, during LBNP, and following space flight. The reasons for this difference are the subject of some debate, but anthropometric factors, the vasoactive effects of sex hormones, gender differences in susceptibility to motion sickness, catecholamine levels, ability to augment total peripheral resistance in response to orthostatic stress, and structural differences in cardiac anatomy and physiology have all been suggested. This finding led to the exclusion of women from the AG pilot study. Clearly if AG is to be employed as a multi-system countermeasure it must provide physiological protection at rotation rates within the tolerance limits of all potential astronauts. Further investigation of the responses of women to centrifugation will be necessary to determine how to adjust AG parameters for tolerance by female subjects before a more detailed investigation of the appropriate dose in terms of G load, rotation rate, exposure duration and frequency can be performed.

Fong, Kevin J.↗

Electron penetration of spacecraft thermal insulation

The external thermal blanket with 13 mils of polyethylene which has the known range and stopping power as a function of electron energy is investiated. The most recent omnidirectional peak Jovian electron flux at 5 Jupiter radii is applied, the electron current penetrating the thermal blanket is calculated and allowed to impinge on a typical 20 mil polyethylene insulator surrounding a wire. The radiation dose rate to the insulator is then calculated and the electrical conductivity found. The results demonstrate that the increased electronic mobility is sufficient to keep the maximum induced electric field two orders of magnitude below the critical breakdown strength.

Powers, W. L.↗

Hypervelocity impact microfoil perforations in the LEO space environment (LDEF, MAP AO-023 experiment)

The Microabrasion Foil Experiment comprises arrays of frames, each supporting two layers of closely spaced metallic foils and a back-stop plate. The arrays, deploying aluminum and brass foil ranging from 1.5 to some 30 microns were exposed for 5.78 years on NASA's LDEF at a mean altitude of 458 km. They were deployed on the North, South, East, West, and Space pointing faces; results presented comprise the perforation rates for each location as a function of foil thickness. Initial results refer primarily to aluminum of 5 microns thickness or greater. This penetration distribution, comprising 2,342 perforations in total, shows significantly differing characteristics for each detector face. The anisotropy confirms, incorporating the dynamics of particulate orbital mechanics, the dominance of incorporating extraterrestrial particulates penetrating thicknesses greater than 20 microns in Al foil, yielding fluxes compatible with hyperbolic geocentric velocities. For thinner foils, a disproportionate increase in flux of particles on the East, North, and South faces shows the presence of orbital particulates which exceed the extraterrestrial component perforation rate at 5 micron foil thickness by a factor of approx. 4.

Mcdonnell, J. A. M.↗

Maintaining Restored Bone with Bisphosphonate in the Ovariectomized Rat Skeleton: Dynamic Histomorphometry of Changes in Bone Mass

This experiment contains the crucial data for the Lose, Restore and Maintain (LRM) concept, a practical approach for reversing existing osteoporosis. The LRM concept uses ovariectomy (ox) to lose bone, an anabolic agent to restore bone mass and then switches to an antiresorptive agent to maintain bone mass. We ox'd or sham-ox'd rats for 150 days (Loss Phase), treated them with 6 mg PGE(sub 2)kg/d for 75 days to restore lost cancellous bone mass (Restore Phase) and then stopped PGE(sub 2) treatment and began treatment with 1 or 5 micrograms/kg Risedronate, a bisphosphonate twice a week for 60 days (Maintain Phase). During the Loss Phase, cancellous bone volumes of the Proximal Tibial Metaphysis (PTM) in the ox'd rat fell to 19% of initial controls. During the Restore Phase, the PTM bone volume in ox'd rats doubled. However, when PGE(sub 2) treatment was stopped, the PGE(sub 2)-induced cancellous bone disappeared. In contrast, 5 miligrams of Risedronate inhibited the bone loss and maintained it at the PGE(sub 2) treatment level. The key dynamic histomorphometry value for the Restore (R) and Maintenance (M) phases was the ratio of bone formation to resorption rates. The ratio was elevated to 5.8 in the R phase and depressed to 0.4 for no and 1 miligram Risedronate treated M phase and to a ratio of near unity of 1.1 for the 5miligrams Risedronate treatment. These findings indicate that we were successful in maintaining the new PTM bone induced by PGE(sub 2) after discontinuing PGE(sub 2) by administering enough Risedronate, a resorption inhibitor. We concluded that the LRM concept is correct and such an approach should be considered when employing anabolic agents or growth factors in the treatment of osteoporosis. Continued use of an anabolic agent may not be appropriate because of cost, potential adverse side effects and a loss of efficacy.

Jee, W. S. S.↗

Proton Nonionizing Energy Loss (NIEL) for Device Applications

Nonionizing energy loss (NIEL) is a quantity that describes the rate of energy loss due to atomic displacements as a particle traverses a material. The product of the NIEL and the particle fluence (time integrated flux) gives the displacement damage energy deposition per unit mass of material. NIEL plays the same role to the displacement damage energy deposition as the stopping power to the total ionizing dose (TID). The concept of NIEL has been very useful for correlating particle induced displacement damage effects in semiconductor and optical devices. Many studies have successfully demonstrated that the degradation of semiconductor devices or optical sensors in a radiation field can be linearly correlated to the displacement damage energy, and subsequently to the NIEL deposited in the semiconductor devices or optical sensors. In addition, the NIEL concept was also useful in the study of both Si and GaAs solar cells and of high temperature superconductors, and at predicting the survivability of detectors used at the LHC at CERN. On the other hand, there are some instances where discrepancies are observed in the application of NIEL, most notably in GaAs semiconductor devices. However, NIEL is still a valuable tool, and can be used to scale damages produced by different particles and in different environments, even though this is not understood at the microscopic level.

Jun, Insoo↗

Experiments on multiplane balancing using a laser for material removal

The modifications of a flexible rotor system for two-plane laser balancing is described. Experimental testing of the laser material removal method for balancing through the first bending critical speed was demonstrated. The test rig, optical configuration, and a neodymium glass laser system were assembled and calibrated for static and rotating material removal rates. The laser control computer program was combined with the influence coefficient balancing process, resulting in a completely automated data acquisition, laser, and balancing system. The laser system rotor was balanced through the first bending critical speed using the laser material removal procedure to apply trial weights and correction weights without stopping the rotor.

Demuth, R. S.↗

Simulator evaluation of a display for a Takeoff Performance Monitoring System

A Takeoff Performance Monitoring System (TOPMS) has been developed to provide the pilot with graphic and numeric information pertinent to his decision to continue or abort a takeoff. The TOPMS information display consists primarily of a runway graphic overlaid with symbolic status, situation, and advisory information including: (1) current position and airspeed; (2) predicted locations for reaching decision speed (V sub 1) and rotation speed (V sub R); (3) groundroll limit for reaching (V sub R); (4) predicted stop point for an aborted takeoff from current conditions; (5) engine-status flags; and (6) an overall situation advisory flag that recommends continuation or rejection of the takeoff. In this study, 32 experienced multi-engine pilots evaluated the TOPMS on the Langley B-737 real-time research simulator. They rated the system satisfactory - good and judged it to be suitable for implementation on an aircraft. The TOPMS, the TOPMS simulation, and the results of the simulator evaluation are described here. Appendices contain the pilot's prebriefing package (written explanation of the TOPMS--sent to the pilots prior to their visit), evaluation instructions, debriefing questions, and rating criteria (organized into a flow diagram similar to the Cooper-Harper diagram for evaluation of aircraft handling qualities).

Middleton, David B.↗

The deceleration of infalling plasma in magnetized neutron star atmospheres - Nonisothermal atmospheres

This paper examines the deceleration of accreting material in the strongly magnetized plasma atmosphere of an X-ray pulsar, for accretion rates less than 0.1 times the Eddington flux. The previous work on accretion, flow deceleration is extended to nonisothermal atmospheres. A rough model of radiative processes in neutron star atmospheres bombarded by accreting material is used to calculate the atmosphere's temperature and density profiles. The atmospheric structure and the accretion flow stopping depth are computed iteratively. For cases where the infall velocity is close to the free-fall velocity, a simple prescription for an equivalent single temperature, T(iso), is given. It is found that the plasma deceleration is close to stopping in a homogeneous, isothermal atmosphere at T(iso). Exceptions to this result occur for small infall velocities.

Miller, Guy↗