Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage capability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

High energy density redox flow device

Redox flow devices are described including a positive electrode current collector, a negative electrode current collector, and an ion-permeable membrane separating said positive and negative current collectors, positioned and arranged to define a positive electroactive zone and a negative electroactive zone; wherein at least one of said positive and negative electroactive zone comprises a flowable semi-solid composition comprising ion storage compound particles capable of taking up or releasing said ions during operation of the cell, and wherein the ion storage compound particles have a polydisperse size distribution in which the finest particles present in at least 5 vol % of the total volume, is at least a factor of 5 smaller than the largest particles present in at least 5 vol % of the total volume.

Chiang, Yet-Ming↗

High energy density redox flow device

Redox flow devices are described including a positive electrode current collector, a negative electrode current collector, and an ion-permeable membrane separating said positive and negative current collectors, positioned and arranged to define a positive electroactive zone and a negative electroactive zone; wherein at least one of said positive and negative electroactive zone comprises a flowable semi-solid composition comprising ion storage compound particles capable of taking up or releasing said ions during operation of the cell, and wherein the ion storage compound particles have a polydisperse size distribution in which the finest particles present in at least 5 vol % of the total volume, is at least a factor of 5 smaller than the largest particles present in at least 5 vol % of the total volume.

Chiang, Yet-Ming↗

Methane storage in flexible and dynamical metal–organic frameworks

Recently, there has been significant interest in methane as an abundant and cleaner burning alternative to fossil fuels. Consequently, the design of media capable of the storage of methane under practical conditions has become an area of significant interest to the scientific community. While metal−organic frameworks have seen pronounced examination for this application, flexible metal−organic framework variants have been little examined despite having tremendous promise for methane storage applications. This work provides an overview of the current state of the art regarding the investigation of these systems for the purpose of providing a baseline for future research.

Forrest, Katherine A.↗

Internal Insulation and Corrosion Control of Molten Chloride Storage Tanks

The U.S. Department of Energy Gen3 CSP program aims to develop integrated systems capable of delivering high temperature thermal energy to advanced power cycles [1]. The National Renewable Energy Laboratory (NREL) is leading a multi-national team to validate the potential of a chloride-based molten-salt system that uses a ternary blend of MgCl2/KCl/NaCl to provide higher temperature thermal energy storage capability (Fig. 1a). The economic viability of this concept is dependent on internally insulating the hot and cold storage tanks to enable the use of low-cost steel shells (Fig. 1b).

14 SOLAR ENERGY↗

Dimensionally Reduced Model for Rapid and Accurate Prediction of Gas Saturation, Pressure, and Brine Production in a CO 2 Storage Application: Case Study Using the SACROC Field as Part of SMART Task 5

This technical report presents work conducted by the sub surface analysis team of the Strategic Systems Analysis & Engineering group at NETL for Task 5 of SMART Phase 1. This study involved the development of deep learning models for CO 2 geologic storage that are capable of accurate prediction of spatio-temporal outputs of CO 2 saturation, pressure, and brine production in three dimensional space over a storage operation's injection and post-injection timeframes. The model framework involves ensembling multi-layer encoder networks that provide dimesionality reduction of geologic inputs with fully connected long short-term memory (LSTM) neural networks that generate time-series prediction This approach offers a means to maximize training time efficiency, reduce computational memory burden, and minimize prediction turnaround.

54 ENVIRONMENTAL SCIENCES↗

Advanced Computing, Data Science, and Artificial Intelligence Research Opportunities for Energy-Focused Transportation Science

The Energy Efficient Mobility Systems (EEMS) technology landscape is complex and rapidly evolving, which provides both tremendous opportunities and formidable challenges. Significant alterations to the mobility landscape are underway due to the advent of vehicle and infrastructure connectivity, autonomous driving, and rapid passenger- and freight-vehicle electrification. Advanced computing will play an increasingly important role in enabling the EEMS program to understand and identify the most important levers to improve the energy productivity of future integrated mobility systems. It is also driving new approaches to mobility and the research to unlock an affordable, efficient, safe, and accessible transportation future. Driving much of this change is the collection, analysis, and strategic use of massive amounts of diverse, complex data from infrastructure and vehicles with on-board sensors and data storage and transmission capabilities. Diverse and representative data are key to implementing approaches to maximize mobility energy productivity. While high-fidelity modeling of integrated transportation networks has strengthened our understanding of dynamic movement and behavior patterns, existing tools must be expanded beyond their current focus. This work necessitates data infrastructure investments (e.g., secure-streaming data platforms driven by ubiquitous sensors and video analytics) as well as investments in critical capabilities for large-scale automated analysis and organization using modern machine learning, statistics, and artificial intelligence. Other chief needs include agile, large-scale storage that can be quickly searched and queried for relevant data to support validation and model development, data-sharing agreements, and formatting standards for key data types. The future of public transit must be explored in greater detail, research must inform design, and opportunities must be identified for improving the mobility productivity of public transit in both urban and rural America.

33 ADVANCED PROPULSION SYSTEMS↗

Energy Systems Integration Facility (ESIF): World-Class Systems Integration Capabilities and Research

The Energy Systems Integration Facility (ESIF), located at the National Renewable Energy Laboratory (NREL) South Table Mountain campus, is a world-renowned user facility for research and development of modern, advanced, and clean energy technologies. ESIF is distinguished by its continuously evolving, highly integrated systems that span throughout the building, connecting research capabilities across multiple laboratories and test areas. The primary ESIF research systems include: [1] data, cyber, and control networks, [2] research electrical distribution buses (REDB), [3] thermal integration infrastructure, and [4] hydrogen systems. The data, cyber, and control networks provide monitoring, control, communication, automation, visualization, and time series data storage and tagging capabilities for research projects and ESIF systems, including facility safety functions. The REDB system consists of four dedicated AC and DC electrical power networks that can connect devices located across the facility through versatile, automatic circuit configuration to support complex power electronics experiments up to the megawatt-scale. The thermal integration infrastructure consists of three temperature-conditioned water loops that provide heating and cooling interfaces and capabilities for thermal energy research. The hydrogen systems provide megawatt-scale hydrogen production, drying, compression, high-pressure storage, and delivery to laboratory end uses, including hydrogen fuel cell vehicle fueling. The ESIF research systems interconnect and extend throughout the various lab areas of the facility to create elaborate networks composed of diverse technologies for cutting-edge research. The ESIF capabilities are operated and stewarded by the ESIF Research Operations group, who also actively upgrade and advance the systems to ensure they remain ahead of anticipated research - enabling the success of many pioneering energy integration projects. The poster, created by members of the ESIF Research Operations team, highlights and summarizes the four core integrated systems at ESIF. The poster was first presented at the internal NREL Energize Forum on May 13th, 2024, and received the "Best Poster" award.

capabilities↗

A metric framework for evaluating the resilience contribution of hydropower to the grid

This paper will describe a proposed framework for expressing the resilience of hydropower generation and provide initial case studies for three classes of hydropower, run-of-river hydropower, hydropower with reservoirs, and pumped storage hydropower. Hydropower has great flexibility to provide support during and after natural and man-made events that can disrupt critical infrastructure functionality. The concept of the framework provides for consideration of policy and rules, constraints of the water shed and other allocations of water, storage and plant capabilities to produce real and reactive power, and the strength of the delivery network. The paper details a resilience response metric that has inputs of state of storage and plant level constraints on real and reactive power production. Using the definition of resilience, based on maintaining a minimally normal operations, we provide a qualitative assessment of hydropower’s ability to address the various time scales comprising the “R”s of resilience.

13 HYDRO ENERGY↗

An open-source data storage and visualization platform for collaborative qubit control

Developing collaborative research platforms for quantum bit control is crucial for driving innovation in the field, as they enable the exchange of ideas, data, and implementation to achieve more impactful outcomes. Furthermore, considering the high costs associated with quantum experimental setups, collaborative environments are vital for maximizing resource utilization efficiently. However, the lack of dedicated data management platforms presents a significant obstacle to progress, highlighting the necessity for essential assistive tools tailored for this purpose. Current qubit control systems are unable to handle complicated management of extensive calibration data and do not support effectively visualizing intricate quantum experiment outcomes. In this paper, we introduce Qubit Control Storage and Visualization ( QubiCSV ), a platform specifically designed to meet the demands of quantum computing research, focusing on the storage and analysis of calibration and characterization data in qubit control systems. As an open-source tool, QubiCSV facilitates efficient data management of quantum computing, providing data versioning capabilities for data storage and allowing researchers and programmers to interact with qubits in real time. The insightful visualization are developed to interpret complex quantum experiments and optimize qubit performance. QubiCSV not only streamlines the handling of qubit control system data but also improves the user experience with intuitive visualization features, making it a valuable asset for researchers in the quantum computing domain.

97 MATHEMATICS AND COMPUTING↗

Multi-resolution enhancement for full-spectrum neural representations

Scientific data acquisition continues to outpace storage and analysis capabilities, making voxel-basedrepresentations increasingly intractable. Implicit neural representations (INRs) offer a promising solutionby encoding signals through coordinate-based neural networks, serving as surrogates of data, withcomputational and storage requirements scaling with network complexity rather than data dimensionality.However, smaller INRs struggle to faithfully represent multiscale structures, high-frequency informationand fine textures that constitute a large proportion of scientific measurements. We propose WIEN-INR, atheoretically guided hierarchical INR framework that distributes modelling across resolution scales andenables improved representation capacity through a novel enhancement network to recover subtle details.This multiscale architecture allows smaller networks to retain the full spatial-frequency content of thesignal as well as preserve training efficiency and lower storage cost. Evaluated on distinct raw experimentalmeasurements across scales and complexities, WIEN-INR represents a practical step towards a broaderadoption of neural representations in scientific workflows, delivering compact, robust and high-fidelityrepresentations.

Ni, Yuan [SLAC National Accelerator Laboratory (SL↗

Integration of Pumped Heat Energy Storage with Fossil-Fired Power Plant (Final Report)

The project team of Southwest Research Institute ® (SwRI ® ), Malta Inc. (Malta), and Luminant Generation Company LLC (Luminant) completed a feasibility study for the integration of a 100-MW, 10-hour (1000-MWh) Malta Pumped Heat Energy Storage (MPHES) system with multiple full-sized fossil-fired electricity generation units (EGU) in Luminant portfolio. MPHES is a long-duration, molten-salt-energy storage technology that uses turbomachinery and heat exchangers to transfer energy to a thermal storage media when charging, and removes the heat in a similar fashion when discharging. With high round trip efficiency (60-65%) and long lifespan (30+ years), MPHES provides economic benefits to the fossil-asset owners that can be scaled to integrate with assets across their portfolio. This technology uses hardware components, workforce personnel, and skillsets similar to those used by fossil EGUs, allowing for synergy when co-locating the two technologies. Luminant has approximately 39,000 megawatts of generation across 12 states, operating in six of the seven competitive markets in the U.S. and powered by a diverse portfolio of natural gas, nuclear, coal, and solar facilities. The DeCordova plant in Granbury, Texas, a simple cycle natural gas peaker power plant, was used as the fossil-fired asset in this project. The local market in Granbury, Texas has many influences, including several nearby power plants, a Luminant-owned nuclear plant (Comanche Peak), and substantial wind energy, which causes both negative pricing at night and high market volatility. Reducing false starts of the DeCordova plant and better responding to market volatility would be an economic advantage. Luminant is currently integrating battery storage plant on site to begin addressing these challenges. Integrating long-duration storage, like MPHES, would expand this capability beyond one hour of storage and have the potential to greatly reduce the total number of gas turbine starts. The MPHES charging requirement could help offset the overnight operating costs of Comanche Peak, which cannot load follow, and the nearby Luminant-owned Wise County combined cycle plant that cycles too often. Following the assessment of Luminant’s ERCOT-based portfolio for integration compatibility with Malta’s PHES system and the project tasks of conceptual study, technoeconomic analysis, technology gap assessment, and commercialization plan, the project team effort has resulted in several key outcomes: (1) Identification of market trends in a high-wind penetration market outside a major metropolitan area; (2) Creation of a dispatching model for the MPHES system and the pairing of Li-ion battery with a gas turbine in a real time market; (3) Revenue and cost estimations for operating MPHES alongside a gas peaker plant with real dispatching considerations and comparison with variations in the Malta implementation, including doubling the storage capacity and using two discharge drivetrains; (4) Potential carbon emission reductions possible by replacing gas turbine operation with Malta PHES operation; and (5) Summary of literature-based future market predictions for Texas.

20 FOSSIL-FUELED POWER PLANTS↗

Data-driven offshore CO 2 saline storage assessment methodology

The world produces approximately 50 billion tonnes of greenhouse gases annually. This is measured in CO 2 -equivalents, and geologic CO 2 storage has the potential to advance decarbonization and mitigate greenhouse gas emissions. New technologies to assess offshore carbon storage are needed to address resource, regulatory, and commercial needs. Although most efforts to assess storage resources focus on onshore criteria, offshore reservoirs offer significant storage potential and distinct development challenges. Potential advantages of offshore carbon storage include being further from human population centers and less potential to interact with groundwater. The U.S. Department of Energy's method for evaluating storage capacity in non-oil-bearing saline reservoirs has been enhanced to support assessments for offshore environments in the Offshore CO 2 Saline Storage methodology (OCSS). This methodology applies data-driven capabilities to estimate saline storage capacity while accounting for features specific to offshore reservoirs. Features include changes in CO 2 density and sedimentary differences that impact estimates of permanence and capacity. The Offshore CO 2 Saline Storage Calculator mechanizes OCSS to estimate storage capacity. This paper presents the methodology and estimates for 18 geologic domains in the Gulf of Mexico. Potential storage distributions, sensitivity analyses, and the incorporation of spatial data and tools to support safe site selection are also discussed.

58 GEOSCIENCES↗

Energy storage technology with extreme high energy density capability

A capacitor includes a first electrode having a substrate and a plurality of nanostructures physically and electrically coupled to the substrate. The capacitor also includes a solid, non-conductive interlayer deposited over the nanostructures to coat the nanostructures, and extending between the nanostructures, and a second electrode deposited over the interlayer and extending between the nanostructures. The interlayer insulates the first and second electrode layers from one another.

Gao, Kaizhong↗

Rate capability and Ragone plots for phase change thermal energy storage

Phase change materials can improve the efficiency of energy systems by time shifting or reducing peak thermal loads. The value of a phase change material is defined by its energy and power density—the total available storage capacity and the speed at which it can be accessed. These are influenced by material properties but cannot be defined with these properties alone. In this work, we show the close link between energy and power density by developing thermal rate capability and Ragone plots, a framework widely used to describe the trade-off between energy and power in electrochemical storage systems (that is, batteries). Our results elucidate how material properties, geometry and operating conditions influence the performance of phase change thermal storage. This research sets a clear framework for comparing thermal storage materials and devices and can be used by researchers and designers to increase clean energy use with storage.

25 ENERGY STORAGE↗

Is a Generator the Only Solution When the Grid Fails? Optimizing Systems for Resiliency and Carbon Reduction: Preprint

Traditionally, buildings are dependent on utility infrastructure, and when a grid failure happens, end users rely on the closest source of energy storage to sustain operation until power is restored. For buildings, that typically means using an electric generator. This electric generator either uses on-site energy storage such as fossil fuels in a tank or a gas connection which is, in turn, tied to gas wells—also a form of energy storage. Generators are popular for their ease of implementation and low capital costs; however, they have limited value outside of disruptions, and they are a source of scope 1 emissions, or direct greenhouse gas emissions from sources controlled by the building owner. In contrast, some power generation and storage systems, such as photovoltaic (PV) panels and battery energy storage systems (BESS), can serve the same purpose during grid disruptions while presenting advantages outside of power failure. This paper explores methods for storing and converting energy on-site to increase building resiliency, focusing on solutions that minimize scope 1 emissions. We analyze the cost and carbon impacts of energy efficiency measures, PV arrays, and BESS, with and without generators, in a simulation test case. We find significant benefits can be achieved both during and outside of power failure events when designing systems that integrate the on-demand capability of generators, the low carbon energy supplied by PV, and the storage capabilities of BESS. Specifically, adding even minimal BESS and PV can result in downsizing the generator, increasing generator efficiency and requiring less fuel.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Modeling of Particle Thermal Energy Reservoir for Solar Industrial Process Heat (Final Technical Report)

Industrial process heat is a leading source of carbon emissions in the United States. To achieve decarbonization goals and reduce costs, solar industrial process heat (SIPH) systems have been investigated as a means of providing a carbon-free heat supply. Particle thermal energy storage (TES) could supplement solar resources (i.e., concentrating solar thermal and photovoltaics) to enable a high capacity factor (> 90%), carbon-free heat source. Particle TES has been considered due to its low-cost storage medium and capability to support a wide range of temperatures. This report provides technical details of developing a component and system modeling tool for a unique particle TES platform to assist the adoption of SIPH technology.

14 SOLAR ENERGY↗

Assessing the Optical Performance Impact of Tracking Error in an Operational Concentrated Solar Power Plant Using Monte Carlo Ray-Tracing Simulation

Concentrating Solar Power (CSP) provides firm and dispatchable electricity due to its thermal storage and hybridization capabilities, which supports the decarbonization of our energy supply. Of the various CSP technologies, parabolic trough collectors are the most mature, with over 500 MW operating worldwide. The optical performance of parabolic trough systems is sensitive to tracking error, which is defined as the angular offset of a collector away from the sun position in the transversal plane. Tracking error commonly occurs due to non-continuous adjustment of the trough angle to point toward the sun, but other factors such as gravity, heating, and wind loading can also contribute to tracking error. Researchers have explored the impact of tracking error on optical performance both numerically and experimentally, but existing studies do not include measurements from operational utility-scale power plants. Tilt angle measurements of parabolic troughs at operational utility-scale power plants illustrate spatial variations in optical performance and include various sources of tracking error such as gravity, heating, and wind loading. To fully characterize wind driven loads on parabolic troughs, we are conducting a long-term field measurement campaign at the Nevada Solar One CSP plant located in Boulder City, NV, which has a nominal capacity of 72 MW and 0.5 hours of full-load storage. We record load measurements on four outer trough rows, collecting support structure bending moments, drive torque moments, dynamic accelerations of the spaceframe, mirror displacement, and tilt angles. Using the tilt measurements acquired at 20 Hz frequency, we calculate the deviation between the nominal sun position and the tracker angle. Using a Monte-Carlo ray-tracing simulation software, we assess the impact of the tracker angle deviation on optical performance throughout the diurnal cycle at various spatial locations within the CSP plant. In our view, this first-of-a-kind study will provide important guidance for future trough designs that reduce the impact of various sources of tracking error on performance.

concentrating solar power↗

Improving the Accessibility and Usability of Geothermal Information with Data Lakes and Data Pipelines on the Geothermal Data Repository: Preprint

The Geothermal Data Repository (GDR) provides universal access to data and information resulting from research and development activities funded by the Department of Energy (DOE). The GDR has extended this universal access to big data through integration with data lakes developed by the Open Energy Data Initiative (OEDI). Previously, large datasets such as seismic waveform or distributed acoustic sensing (DAS) data could only be accessed by institutions with high performance data storage and compute capabilities, effectively limiting the accessibility of big data to national labs, larger universities, and major corporations. Moreover, the time and resources needed to transport big data and configure them can produce additional barriers to use. Many of the standard formats used for structured data models (also known as content models) are incapable of handling big data and can introduce additional usability problems, often requiring data to be reformatted prior to use. This paper will explore how recent integrations between the GDR and the OEDI data lake have improved the accessibility and usability of geothermal data in a big way, making the data available to a broader audience, and enabling collaborative analysis and innovation across the greater geothermal industry.

access↗