Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage resources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Research Software Engineering Efforts for DataFlow: FY2021 Developments

DataFlow is a web application that helps scientific data to flow from one source location to another destination location. DataFlow helps scientists easily capture scientific metadata associated with an experiment and transmit both metadata and experimental data to a designated, centralized data storage resource. This report describes the software engineering efforts and architecture of the project for the fiscal year 2021 developments. We hope it effectively communicates findings from our work, challenges we have overcome, and how we will continue our development of DataFlow in the future.

42 ENGINEERING↗

Understanding Lustre Internals. Second Edition

The Lustre file system has become a preferred storage resource for systems on the Top500 list, and it is often the file system of choice for small- to medium-sized HPC systems that require parallel shared access to data. Several resources exist to help users deploy and configure Lustre, but the same cannot be said for resources that explain the inner workings of the Lustre source code. A previous ORNL technical report entitled "Understanding Lustre Filesystem Internals" (ORNL/TM-2009/117) provided an excellent summary of Lustre subsystem operations. However, that report is over a decade old and is based on Lustre version 1.6. Since that report was published, Lustre has evolved significantly. Several subsystems underwent significant code changes and many new features have been added to the file system, bringing the current Lustre version up to 2.15.This report aims to document and explain the internal workings of the latest version of the Lustre file system. It will provide more complete and up-to-date information than the previous technical report and should serve as a foundational document for anyone interested in Lustre software development. Key data structures will be described along with the APIs used for interaction among the various Lustre subsystems. Although the Lustre software is constantly being developed, the details in this document should remain relevant for the forseeable future.

97 MATHEMATICS AND COMPUTING↗

Performance Analysis and Optimization for Scientific Data Workloads

Scientific data generated at experimental and observational facilities are increasingly being processed on large-scale compute systems. Most of the experimental data analysis workflows are not designed or implemented to run on large scale environments and take full advantage of HPC compute and storage resources. These applications are unlike the traditional tightly-coupled scientific applications and hence face significant performance and scalability challenges as the volume of data increases exponentially. In this paper, we conduct a performance and scalability analysis for experimental analysis applications and workflows operating on data from light sources. Our analysis detects and quantifies I/O performance, scalability and runtime bottlenecks for three data analysis applications that run on NERSC resources. Based on our analysis we propose and implement a set of optimizations that lead to reducing the amount of time spent on I/O operations by almost 90%.

97 MATHEMATICS AND COMPUTING↗

Los Angeles Air Force Base Vehicle-to-Grid Demonstration (Final Project Report)

Electrification of non-tactical vehicle fleets represents a key efficiency and energy security objective for the United States Department of Defense. To achieve electrification, the department targeted vehicle-to-grid services as a way to decrease the overall cost of operating the vehicle fleet and achieve rough parity with traditional internal combustion engine vehicle fleets. This report describes efforts to aggregate a fleet of bi-directional electric vehicles and charging stations to provide regulation up and regulation down in the California Independent System Operator ancillary services market. A 29-vehicle electric vehicle demonstration fleet, consisting of mixed purpose and duty vehicles such as sedans, pickups, vans, and medium-duty trucks, was deployed at the Los Angeles Air Force base. The fleet provided frequency regulation to the California Independent System Operator’s wholesale electricity market to determine the capability of recouping some of the additional costs of procuring electric vehicles and their supporting infrastructure. Lawrence Berkeley National Laboratory, with its partner Kisensum, LLC, developed the fleet scheduling, optimization, and control software to allow the vehicle fleet at the air force base to participate in the ancillary services markets. This report focuses on the control software and market interactions, the significant challenges faced and solutions devised to address them, and examines the potential of using the electric vehicle fleet as an energy storage resource for the base buildings, an application known as vehicle-tobuilding, in providing demand response and emergency backup power. The report discusses key findings related to providing frequency regulation to the California Independent System Operator market, electric vehicle fleet performance, compatibility of varying resource parameters of vehicle fleet aggregation, the need for automated methods for communicating hour-ahead energy bidding, challenges related to battery capacity and charge/discharge rates, and monthly settlement revenue.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

An intelligent Data Delivery Service for and beyond the ATLAS experiment

The intelligent Data Delivery Service (iDDS) has been developed to cope with the huge increase of computing and storage resource usage in the coming LHC data taking. It has been designed to intelligently orchestrate workflows and data management systems, decoupling data pre-processing, delivery, and primary processing in large scale workflows. It is an experiment-agnostic service that has been deployed to serve data carousel (orchestrating efficient processing of tape-resident data), machine learning hyperparameter optimization, active learning, and other complex multi-stage workflows defined via DAG (Directed Acyclic Graph), CWL (Common Workflow Language) and other descriptions, including a growing number of analysis workflows. We will at first introduce some deployed use cases in a summary. Then we will focus on new improvements and use cases under developments in ATLAS, Rubin Observatory and sPHENIX, together with future efforts.

97 MATHEMATICS AND COMPUTING↗

Insight into the Radiolytic Degradation Mechanism of TODGA

Partitioning and transmutation schemes, where americium is separated from other components of used nuclear fuel and burned in a fast neutron reactor, offer a path to dramatically decrease the space requirements for storage of nuclear fuel cycle wastes, allowing more efficient usage of potentially scarce storage resources.[1] Improvements in the efficiency of processes for separating americium from used nuclear fuels can thus have a significant impact on the costs of future nuclear fuel cycles. Understanding separation ligand radiation chemistry is important for development of new ligands and processes, as the ligand degradation products can have a deleterious effect on a separation process. Tetraoctyl diglycolamide (TODGA) has been studied as a ligand for lanthanide/minor actinide extraction for partitioning and transmutation schemes. However, the mechanism of initial energy transfer from products of solvent radiolysis to TODGA is still under debate. One proposed mechanism is attack by a n-dodecane radical cation resulting in electron abstraction and formation of a TODGA radical cation,[2] while later work has proposed hydrogen abstraction from sites adjacent to the central ether oxygen by other radical species.[3] The latter mechanism is proposed to result in degradation products from rupture of the ether bond. However, radiolytic degradation of TODGA in n-dodecane shows products that would result from rupture of all the backbone bonds. There is little information on what degradation products would be expected to form from the TODGA radical cation. In this work, we have begun to investigate this by examining the electron impact (EI) ionization mass spectrum of TODGA, which initially produces a TODGA radical cation in the gas phase. The EI spectrum shows fragments that would result from most backbone bond cleavages, similar to what is observed in the radiolysis of TODGA in n-dodecane. As the lifetime of the solvent radical cation decreases from n-dodecane to n-hexane,[4] irradiation of TODGA in n-hexane should have less solvent radical cations available for reaction with TODGA, and instead should favor reactions with longer-lived radicals. In contrast to n-dodecane, radiolytic degradation of TODGA in n-hexane produces only N,N-dioctylacetamide, which would result from rupture of the ether bond. The n-dodecane radical cation lifetime is long enough to produce TODGA radical cations but the n-hexane radical cation is mostly consumed before reaction with TODGA, so other radical processes that abstract hydrogen from TODGA dominate. This suggests that electron abstraction by the n-dodecane radical cation is an important component of TODGA radiolysis, although it does not rule out the presence of mechanisms involving hydrogen abstraction adjacent to the ether oxygen. References [1] J. Serp et al., Energies 2017, 10 (9), DOI: 10.3390/en10091445. [2] C. Zarzana et al., Solvent Extr. Ion Exch. 2015, 33 (5), 431–447, DOI: 10.1080/07366299.2015.1012885. [3] T. Koubský et al., Prog. Nucl. Energy 2017, 94, 208–215, DOI: 10.1016/j.pnucene.2016.07.010. [4] F. Sviridenko et al., Chem. Phys. Lett. 1998, 297 (3), 343–349, DOI: 10.1016/S0009-2614(98)01099-9.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Utility Perspective on Protection Challenges with High IBR Penetration [Slides]

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Impacts of Renewable and Storage Technologies on Resource Adequacy

This presentation kicked off the 2020 Austin Electricity Conference, Panel 1: Impacts of Low-Carbon Technologies on Resource Adequacy. This short presentation provided a brief introduction to resource adequacy and then highlighted a few illustrative examples for how increasing penetrations of variable renewable energy and storage is changing how we think about and model resources adequacy. Key themes were how all hours of the year matter (with particular importance on peak net load instead of peak load) and how greater operational detail needs to be included in resource adequacy modeling.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Paving the way for Stakeholder use of Carbon Storage & Transport Digital Resources

This online resource is intended to provide a comprehensive “one-stop-shop” for understanding the availability of tools, data, and models developed under the Bipartisan Infrastructure Law (BIL) as they relate to supporting stakeholders’ Carbon Storage and Transport needs. To support accessibility of these BIL products, supplemental information regarding project life-cycle relevance, update history, release dates, input and output formats, and example use-cases will be integrated into consistent and accessible Story Map formats. This presentation is to update on the progress of this effort and detail anticipated next steps associated with ongoing development.

Martin, Abigail↗

Snowmass 2021 Computational Frontier CompF4 Topical Group Report Storage and Processing Resource Access

Computing plays a significant role in all areas of high energy physics. The Snowmass 2021 CompF4 topical group's scope is facilities R&D, where we consider "facilities" as the computing hardware and software infrastructure inside the data centers plus the networking between data centers, irrespective of who owns them, and what policies are applied for using them. In other words, it includes commercial clouds, federally funded High Performance Computing (HPC) systems for all of science, and systems funded explicitly for a given experimental or theoretical program. This topical group report summarizes the findings and recommendations for the storage, processing, networking and associated software service infrastructures for future high energy physics research, based on the discussions organized through the Snowmass 2021 community study.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effects of Deep Reductions in Energy Storage Costs on Highly Reliable Wind and Solar Electricity Systems.

We use 36 years (1980-2015) of hourly weather data over the contiguous United States (CONUS) to assess the impact of low-cost energy storage on highly reliable electricity systems that use only variable renewable energy (VRE; wind and solar photovoltaics). Even assuming perfect transmission of wind and solar generation aggregated over CONUS, energy storage costs would need to decrease several hundred-fold from current costs (to ~$1/kWh) in fully VRE electricity systems to yield highly reliable electricity without extensive curtailment of VRE generation. The role of energy storage changes from high-cost storage competing with curtailment to fill short-term gaps between VRE generation and hourly demand to near-free storage serving as seasonal storage for VRE resources. Energy storage faces "double penalties" in VRE/storage systems: with increasing capacity, (1) the additional storage is used less frequently and (2) hourly electricity costs would become less volatile, thus reducing price arbitrage opportunities for the additional storage.

14 SOLAR ENERGY↗

Probabilistic Modeling of Climate Change Impacts on Renewable Energy and Storage Requirements for NM's Energy Transition Act (SAND Report)

This report provides a study of the potential impacts of climate change on intermittent renewable energy resources, battery storage, and resource adequacy in Public Service Company of New Mexico’s Integrated Resource Plan for 2020 – 2040. Climate change models and available data were first evaluated to determine uncertainty and potential changes in solar irradiance, temperature, and wind speed in NM in the coming decades. These changes were then implemented in solar and wind energy models to determine impacts on renewable energy resources in NM. Results for the extreme climate-change scenario show that the projected wind power may decrease by ~13% due to projected decreases in wind speed. Projected solar power may decrease by ~4% due to decreases in irradiance and increases in temperature in NM. Uncertainty in these climate-induced changes in wind and solar resources was accommodated in probabilistic models assuming uniform distributions in the annual reductions in solar and wind resources. Uncertainty in battery storage performance was also evaluated based on increased temperature, capacity fade, and degradation in round-trip efficiency. The hourly energy balance was determined throughout the year given uncertainties in the renewable energy resources and energy storage. The loss of load expectation (LOLE) was evaluated for the 2040 No New Combustion portfolio and found to increase from 0 days/year to a median value of ~2 days/year due to potential reductions in renewable energy resources and battery storage performance and capacity. A rank-regression analyses revealed that battery round-trip efficiency was the most significant parameter that impacted LOLE, followed by solar resource, wind resource, and battery fade. An increase in battery storage capacity to ~25,000 – 30,000 MWh from a baseline value of ~14,000 MWh was required to reduce the median value of LOLE to ~0.2 days/year with consideration of potential climate impacts and battery degradation.

54 ENVIRONMENTAL SCIENCES↗

Impact of Storage Dispatch Assumptions on Resource Adequacy and Capacity Credit

Representing energy-limited resources in power system probabilistic resource adequacy assessment introduces new considerations that invalidate classical modeling assumptions. In particular, such resources have multi-period operating objectives and constraints that in real systems are addressed via a sequence of rolling intertemporal optimizations. Ideally, adequacy models would develop dispatch decisions by solving a similar sequence of problems, but this approach has historically been too computationally intensive for practical use in Monte Carlo simulations, with studies making use of simplifying approximations instead. These simplifications have the potential to distort the assessed value of energy-limited resources on the system.This work describes three classes of storage dispatch assumptions in current use and discusses their theoretical differences. It then provides an empirical analysis of their differences on test systems with different levels of storage, assessing the potential for a study's modeling assumptions to influence the perceived contribution of energy-limited resources.

capacity credit↗

Hydropower Value Drivers

Conventional hydro resources generate the majority of their value by providing energy under most conditions, but the relative fraction of value generated by providing ancillary services and capacity increases with increasing penetration of resources with zero fuel costs. Pumped storage hydropower resources generate the majority of their value by providing capacity under most conditions, but the relative fraction of value generated by providing energy increases with increasing penetration of resources with zero fuel costs. The total value of conventional hydropower generally decreases in systems with increasing penetration of resources with zero fuel costs; this is largely due to the associated decrease in average energy prices. The total value of pumped storage generally increases in systems with increasing penetration of resources with zero fuel costs, largely due to opportunities to operate in pumping mode when energy prices are low or even negative. Energy storage representation must be enhanced to ensure that models accurately capture system value streams for these resources. Current power system models have a limited ability to capture the price dynamics of ancillary services, and it is still challenging to assess the role and magnitude of ancillary service value streams in future systems. Power systems are currently in a state of rapid and dramatic evolution due to a number of different factors, including the increasing penetration of variable renewable energy (VRE) sources, such as wind and solar, and battery energy storage systems (BESS). This evolution will change the way power systems are fundamentally planned and operated. Some of these changes may be incremental, while others may be more significant, but the result will likely be parallel evolution in the definition and requirement of different grid services and therefore a subsequent shift in their relative values. This report presents a framework developed to identify such system value drivers and quantify their relative impact on several different value streams, with a specific focus on implications for conventional hydropower and pumped storage hydropower (PSH) resources. This value drivers framework (VDF) encompasses five core analytical steps: 1. Identify potential drivers and develop scenarios, 2. Execute production cost models, 3. Calibrate prices, 4. Optimize hydropower operations, and 5. Quantify value drivers.

13 HYDRO ENERGY↗

Clear Sky Tampa Bay: Project and Toolkit Overview - Resilience-Based Resources for Assessing Solar + Storage on Critical Facilities

The Clear Sky Tampa Bay Team, convened by the Tampa Bay Regional Planning Council (TBRPC) and composed of county and city partners, private and public sector stakeholders, solar energy experts, and academic partners, collaboratively developed a set of resources to support the expanded use of solar + storage in the context of community resilience in Florida. Key questions guiding the project included: (1) What types of buildings and systems provide the maximum resilience benefits? (2) Where within our communities should we prioritize future solar + storage analysis or investment to mitigate the impacts of disasters? (3) How might other societal variables be incorporated into a site assessment when considering solar + storage for resilience? (4) Can a standardized process be developed that leverages existing resources to assist local governments with solar + storage for resilience research and decision-making?

14 SOLAR ENERGY↗