Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage system model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Country-level land carbon sink and its causing components by the middle of the twenty-first century

Abstract Background Countries have long been making efforts by reducing greenhouse-gas emissions to mitigate climate change. In the agreements of the United Nations Framework Convention on Climate Change, involved countries have committed to reduction targets. However, carbon (C) sink and its involving processes by natural ecosystems remain difficult to quantify. Methods Using a transient traceability framework, we estimated country-level land C sink and its causing components by 2050 simulated by 12 Earth System Models involved in the Coupled Model Intercomparison Project Phase 5 (CMIP5) under RCP8.5. Results The top 20 countries with highest C sink have the potential to sequester 62 Pg C in total, among which, Russia, Canada, USA, China, and Brazil sequester the most. This C sink consists of four components: production-driven change, turnover-driven change, change in instantaneous C storage potential, and interaction between production-driven change and turnover-driven change. The four components account for 49.5%, 28.1%, 14.5%, and 7.9% of the land C sink, respectively. Conclusion The model-based estimates highlight that land C sink potentially offsets a substantial proportion of greenhouse-gas emissions, especially for countries where net primary production (NPP) likely increases substantially and inherent residence time elongates.

54 ENVIRONMENTAL SCIENCES↗

Impacts of Dispatch Strategies and Forecast Errors on the Economics of Behind-the-Meter PV-Battery Systems: Preprint

To assess the economic value of batteries in hybrid PV-battery systems, one must create a dispatch profile for the battery. Many analyses of battery value assume perfect forecasts of PV generation and load, determining an upper limit on the value of the battery. Prior work that accounts for forecast uncertainty often does so in the context of a single dispatch algorithm, which does not provide a baseline for comparison. Furthermore, when multiple dispatch algorithms are assessed with uncertainty, the benefits considered are for diesel generation in a microgrid, not retail rate savings. This work addresses the gaps in the literature by comparing the performance of both heuristic and optimal dispatch algorithms for retail rate savings under forecast uncertainty, and provides comparisons of the robustness of these algorithms and their associated estimates of economic value. We find that using a perfect forecast can overestimate the value of hybrid PV-battery systems between 1% and 8% compared to the reality of using a day-ahead forecast, depending on the dispatch algorithm used. Thus, accounting for forecast uncertainty in system design and analysis will significantly improve the accuracy of modeled system values.

batteries↗

Benefit Analysis of Long-Duration Energy Storage in Power Systems with High Renewable Energy Shares

The integration of high shares of variable renewable energy raises challenges for the reliability and cost-effectiveness of power systems. The value of long-duration energy storage, which helps address variability in renewable energy supply across days and seasons, is poised to grow significantly as power systems shift to larger shares of variable generation such as wind and solar. This study explores the system-level services and associated benefits of long-duration energy storage on the 2050 Western Interconnection (WI). The operation of the future WI system with 85% renewable penetration is simulated using a two-stage production cost model. The impact of long duration energy storage on systemwide operations is examined for the 2050 WI system, using a range of round-trip efficiencies corresponding to four different energy storage technologies. The analysis projects the energy storage dispatch profile, system-wide production cost savings (from both diurnal and seasonal operation), and impacts on generation mix, and change in renewable generation curtailment.

25 ENERGY STORAGE↗

Optimization-Based Dynamic Voltage Support of Microgrids Using Energy Storage Systems

A microgrid network is characterized by a high R/X ratio, making the voltage more sensitive to active power changes compared to bulk power systems, where the voltage is regulated primarily by reactive power. Due to its sensitivity, voltage control approaches for microgrids should also consider the active power input coupling, making it very different from conventional power systems. Additionally, as the energy costs associated with active and reactive powers are different and the operational conditions of microgrids connected to active distribution systems vary over time, the ideal controller to provide voltage support must be flexible enough to handle these technical and operational constraints. This paper proposes a model predictive control approach to provide dynamic voltage support using energy storage systems. This approach uses a simplified predictive model of the system to solve the model predictive control problem. By proper selection of model predictive control weighting parameters, the quality of service provided can be adjusted to achieve the desired performance. A simulation study in MATLAB/Simulink validates the proposed approach for the Cordova, Alaska microgrid. Results show that the performance of the voltage support can be adjusted depending on the choice of weight and constraints of the controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Control, Penetration, and Distribution of Embedded Storage Network in Bulk Power System

The current shift in generation mix from fossil fuel plants towards variable and intermittent renewable energy sources is poised to create a future grid with reduced physical inertia and mismatch between generation and demand. Embedded storage, which is a concept of a coordinated network of storage units sited at the interface between the transmission and distribution system, is proposed as a mechanism to provide a buffer between generation and demand. This paper proposes an automated framework to model and integrate embedded storage in large-scale power systems with industry-grade grid-following (GFL) and grid-forming (GFM) control technologies. More importantly, the developed framework is used to explore the impacts of embedded storage control, penetration, location, and capacity in providing fast frequency response to the grid under contingency events such as generator trips and faults. The framework and study are conducted using the transient-stability simulation tool PSS/E and a realistic model of the Puerto Rico grid as a chosen test system. The simulation results show that GFL and GFM embedded storage, distributed throughout the system, with sufficient penetration and capacity, can effectively improve primary frequency response of the system under the studied contingency events.

Battery Energy Storage, embedded storage, grid-for↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM’s existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model: Preprint

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM’s existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Exploring the Future Energy Value of Long-Duration Energy Storage

Long-duration energy storage is commonly viewed as a key technology for providing flexibility to the grid and broader energy systems over a multidecadal time frame. However, prior work has typically used present-day grid infrastructures to characterize the relationship between the duration and arbitrage value of storage in electricity markets. This study leverages established National Renewable Energy Laboratory grid planning and operations tools, analysis, and data to execute a price-taker model of an energy storage system for several 8760 h price series representative of current and future contiguous United States grid infrastructures with varying shares of variable renewable energy (VRE). We find that the total value of energy storage typically increases with VRE shares, but any increase in the relative value of longer storage durations over time depends on the region and grid mix. Some regions see incremental value increasing notably, up to 20–40 h in 2050, while others do not. The negative effect of lower roundtrip efficiency on value is also found to be scenario-dependent, with the energy value in higher VRE scenarios being less sensitive to roundtrip efficiency and more supportive of longer storage durations. Long-duration storage value and deployment potential are a function of evolving electricity sector infrastructure, markets, and policy, making it critical to consistently revisit potential long-duration storage contributions to the grid.

14 SOLAR ENERGY↗

Machine Learning-Assisted Stability Boundary Determination of Multiport Autonomous Reconfigurable Solar Power Plants

The multiport autonomous reconfigurable solar (MARS) power plant is a promising solution to integrate renewable resources and energy storage systems into the alternating current (ac) power grid and an high-voltage direct current (HVdc) link. In the MARS system, various input power sources are connected to the individual submodules (SMs) through direct current (dc)–dc converters. However, the presence of external power sources can result in unbalanced capacitor voltages of SMs, thereby violating stability constraints under multiple/diverse operating conditions. This article aims to address the gap by accurately determining the stability boundary of the MARS system. As such, a novel machine learning (ML)-assisted energy balancing control (EBC) criterion is proposed. Further, in conjunction with a refined EBC, this approach ensures balanced capacitor voltages across various types of SMs, significantly enhancing the overall system efficiency. The proposed EBC criterion effectively controls EBC activation and deactivation, achieving remarkable accuracy. Both power systems computer aided design (PSCAD)/electromagnetic transients including direct current (EMTDC) simulations and control hardware-in-the-loop (cHIL) tests are conducted to validate the feasibility and efficiency of the proposed method. By combining the EBC and ML-assisted EBC criterion, efficient energy management is achieved for systems featuring multiple input power sources, such as MARS. This approach enables the system to fully exploit its potential across an expanded operational range while upholding high-efficiency standards.

14 SOLAR ENERGY↗

Reduced-Order Modeling Method for Phase-Change Thermal Energy Storage Heat Exchangers

Thermal energy storage can facilitate the effective utilization of renewable energy. To speed up the design process of thermal energy storage devices, it is critical to develop fast and accurate modeling methods for phase change material embedded heat exchangers (PCM HXs). This study developed and compared two approximation-assisted reduced-order PCM HX models for the simulation of thermal storage components and systems, which were verified against a validated finite-volume model. They are a pure black-box model, and a grey-box model based on the Number of Transfer Units (or effectiveness-NTU) approach. We used the reduced-order models to predict the performance of standalone PCM HX for 1000 cases with different fluid inlet conditions and HX designs. We also integrated the models with a vapor compression system to predict the compressor energy consumption and total charging time under various conditions. The results show that overall, the black-box model gave more accurate results than the grey-box model. On average, the mean absolute deviation in the PCM HX fluid outlet temperature was 0.05 K and 0.1 K for the black-box model and grey-box model, respectively. The grey-box model gave larger temperature deviation toward the end of the phase change process, due to the simplified two-node PCM representation. On the system level, the mean absolute deviation in compressor energy consumption was 0.2% and 0.3% for the black-box model and grey-box model, respectively. Their mean absolute deviation in total charging time was 1.1% and 2.6%, respectively. In terms of computation efficiency, the system simulation speedup ratio gained by using the reduced-order models was 11 to 57. System simulation time was decreased from an average of 1465 s to an average of 59 s. This shows that the proposed reduced-order modeling methods can be used to predict system performance of PCM HXs with less than 3% accuracy penalty, and 25 times less computational time than finite-volume models, enabling faster design and evaluation of PCM thermal storage devices.

25 ENERGY STORAGE↗

Computational Fluid Dynamic Modeling of Dry Cask Simulator with Crosswind

The purpose of this study is to create a STAR-CCM+ model of a Belowground Vertical Dry Cask Simulator (BVDCS) at Sandia National Laboratories (SNL) and validate the model with SNL’s experimental results. The BVDCS consists of a single boiling water reactor assembly fitted with electric heaters encompassed by a containment vessel and shell to represent a belowground spent nuclear fuel (SNF) dry storage system. Blowers are located near the inlet and outlet of the BVDCS to simulate crosswind conditions. In addition to the experimental results, the STAR-CCM+ model developed for this study is compared with a previous computational fluid dynamics (CFD) model in a different software program, which is used as a software-to-software benchmark. The experimental results provide a dataset to compare the STAR-CCM+ model results for a variety of different conditions. The main objective is to validate and improve STAR-CCM+ CFD models for spent nuclear fuel storage systems with explicitly modeled external environments and “wind driven” crossflows. These CFD models aide in the study of external particle deposition in spent nuclear fuel storage systems, which is important to predicting the significance of chloride induced stress corrosion cracking (CISCC). In addition to experimental comparison, a sensitivity analysis study is performed using the STAR-CCM+ model. The sensitivity analysis provides a quantitative assessment of the sensitivity of various parameters. This helps provide information on various parameters that are of particular importance to constructing a model representative of real life systems. The STAR-CCM+ model compared well to the experimental results showing similar responses to changes in cross wind flow, and a number of parameters are identified for model improvement.

Jensen, Ben J.↗

Catching up with the trees: empirical advancements to improve herbaceous representation in models

Ecosystems dominated by herbaceous vegetation (i.e. nonwoody species) represent c. 40% of the terrestrial land surface on Earth (White et al., 2000), facilitate large quantities of carbon sequestration (reviewed by Bai & Cotrufo, 2022), and provide much of the food production for humans (O'Mara, 2012). Many of these ecosystems are currently in danger of being lost due to global change drivers, shrub encroachment, and calls for afforestation (Bond et al., 2019). Furthermore, our predictive understanding of these systems is limited, which can be seen from high levels of uncertainty in modeled future carbon (C) storage of these systems (e.g. fig. 3 in McGuire et al., 2018).

59 BASIC BIOLOGICAL SCIENCES↗

The Role of Energy Storage in the Uptake of Renewable Energy: A Model Comparison Approach

The power sector needs to ensure a rapid transition towards a low-carbon energy system to avoid the dangerous consequences of greenhouse gas emissions. Storage technologies are a promising option to provide the power system with the flexibility required when intermittent renewables are present in the electricity generation mix. This paper focuses on the role of electricity storage in energy systems with high shares of renewable sources. The study encompasses a model comparison approach where four models (GENeSYS-MOD, MUSE, NATEM, and urbs - MX) are used to analyse the storage uptake in North America. The analysis addresses the conditions affecting storage uptake in each country and its dependence on resource availability, technology costs, and public policies. Results show that storage may promote emissions reduction at lower costs when renewable mandates are in place whereas in presence of carbon taxes, renewables may compete with other low-carbon options. The study also highlights the main modelling approach shortcomings in the modelling of electricity storage in integrated assessment models.

electricity storage↗

Thermal Modeling of Advanced Test Reactor Fuel in a Generalized Dry Storage System Under Hypothetical Accident Conditions

Work was performed to investigate the thermal behavior of a sealed aluminum-clad spent nuclear fuel (ASNF) dry storage configuration under hypothetical accident conditions during long-term storage. The considered system consists of a concrete dry storage overpack; a welded over canister, backfilled with argon; and nine Department of Energy (DOE) standardized canisters (DOESCs) loaded with ASNF, backfilled with helium gas. One technical concern associated with the long-term storage of ASNF includes radiolytic hydrogen generation. The yield of large quantities of hydrogen could lead to DOESC over pressurization or a flammable internal atmosphere. While flammability concerns can be resolved by preventing the ingress of oxygen, the canister pressure is partially controlled by the atmosphere temperature. This memorandum summarizes the results of modeling and simulation (M&S) work completed with Star CCM+ (a computational fluid dynamics [CFD] software) considering the thermal effects of a fully engulfing flame and another scenario with the vent ports of the concrete dry storage overpack completely blocked. The goal was to determine the bounding maximum temperature of the DOESC internal atmosphere to evaluate a worst-case pressure scenario, as well as the critical vent port blockage durations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MRCI Subtask 2.4/2.5: Regional/Subregional Analysis and Risk Assessment Final Technical Summary Report

The objective of the Midwest Regional Carbon Initiative (MRCI) project is to implement a collaborative Regional Initiative (RI) to accelerate the deployment of carbon capture, and storage (CCS) in the Midwest-Northeastern quadrant of the United States. This report is a Technical Summary report describing work performed on Tasks 2.4 (Conducting Regional/Subregional Analysis) and 2.5 (Assessing and Managing Risk) during the MRCI project. In Task 2.4, detailed numerical reservoir simulation models were developed for selected carbon storage (CS) systems identified under Task 2.1 (Battelle, 2021a) in the MRCI study area. The objective of Task 2.4 is to demonstrate a dynamic modeling methodology for evaluating the suitability of the (selected) CS systems in the MRCI region for hosting a commercial-scale storage project. In this study, CO2 injectivity was evaluated for different CS systems with an annual injection rate of 1 million metric tonnes (MMT) of CO2 considered as the minimum requirement for a commercial scale project. The objective of Task 2.5 is to assess key risks associated with storing CO2 in the different CS systems across the MRCI region and to demonstrate a method(s) for assessing these risks that may be used by developers of future CO2 storage projects in the region. The risk analysis was limited to evaluating two types of leakage risks (i.e., wellbore leakage, flow across unfractured caprock) at three modeled sites considered in Task 2.4.

MRCI,Report,Summary,Technical Challenges,dynamic m↗