Search NASA⌕ Search

SEARCH · Search NASA

Results for “stroke”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Connector Mechanism Has Smaller Stroke

System for connecting electrical and/or fluid lines includes mechanism reducing length of stroke necessary to make or break connections. Feature enables connection and disconnection in confined space, and compensates for misalignment between connectors. Connector in active member moves upward at twice the speed of downward stroke of passive member. Stroke amplified within connector system. Applications include connections between modular electronic units, coupled vehicles, and hydraulic systems.

Milam, M. Bruce↗

Method and apparatus for determining return stroke polarity of distant lightning

A method is described for determining the return stroke polarity of distant lightning for distances beyond 600 km by detecting the electric field associated with a return stroke of distant lightning, and processing the electric field signal to determine the polarity of the slow tail of the VLF waveform signal associated with the detected electric field. The polarity of the return stroke of distant lightning is determined based upon the polarity of the slow tail portion of the waveform.

Blakeslee, Richard J.↗

The Tracer Gas Method of Determining the Charging Efficiency of Two-stroke-cycle Diesel Engines

A convenient method has been developed for determining the scavenging efficiency or the charging efficiency of two-stroke-cycle engines. The method consists of introducing a suitable tracer gas into the inlet air of the running engine and measuring chemically its concentration both in the inlet and exhaust gas. Monomethylamine CH(sub 3)NH(sub 2) was found suitable for the purpose as it burns almost completely during combustion, whereas the "short-circuited" portion does not burn at all and can be determined quantitatively in the exhaust. The method was tested both on four-stroke and on two-stroke engines and is considered accurate within 1 percent.

Schweitzer, P H↗

Design of a Long-Stroke Noncontact Electromagnetic Actuator for Active Vibration Isolation

A long-stroke moving coil Lorentz Actuator was designed for use in a microgravity vibration isolation experiment. The final design had a stroke of 5.08 cm (2 in) and enough force capability to isolate a mass of the order of 22.7-45.4 kg. A simple dynamic magnetic circuit analysis, using an electrical analog, was developed for the initial design of the actuator. A neodymium-iron-boron material with energy density of 278 T-kA/m (35 MGOe) was selected to supply the magnetic field. The effect of changes in the design parameters of core diameter, shell outer diameter, pole face length, and coil wire layers were investigated. An extensive three-dimensional finite element analysis was carried out to accurately determine linearity with regard to axial position of the coil and coil current levels. The actuator was constructed and tested on a universal testing machine. Example plots are shown, indicating good linearity over the stroke of approximately 5.08 cm (2 in) and a range of coil currents from -1.5 A to +1.5 A. The actuator was then used for the microgravity vibration isolation experiments, described elsewhere.

Banerjee, Bibhuti↗

Development and Preliminary Testing of a High Precision Long Stroke Slit Change Mechanism for the SPICE Instrument

In the frame of ESA's Solar Orbiter scientific mission, Almatech has been selected to design, develop and test the Slit Change Mechanism of the SPICE (SPectral Imaging of the Coronal Environment) instrument. In order to guaranty optical cleanliness level while fulfilling stringent positioning accuracies and repeatability requirements for slit positioning in the optical path of the instrument, a linear guiding system based on a double flexible blade arrangement has been selected. The four different slits to be used for the SPICE instrument resulted in a total stroke of 16.5 mm in this linear slit changer arrangement. The combination of long stroke and high precision positioning requirements has been identified as the main design challenge to be validated through breadboard models testing. This paper presents the development of SPICE's Slit Change Mechanism (SCM) and the two-step validation tests successfully performed on breadboard models of its flexible blade support system. The validation test results have demonstrated the full adequacy of the flexible blade guiding system implemented in SPICE's Slit Change Mechanism in a stand-alone configuration. Further breadboard test results, studying the influence of the compliant connection to the SCM linear actuator on an enhanced flexible guiding system design have shown significant enhancements in the positioning accuracy and repeatability of the selected flexible guiding system. Preliminary evaluation of the linear actuator design, including a detailed tolerance analyses, has shown the suitability of this satellite roller screw based mechanism for the actuation of the tested flexible guiding system and compliant connection. The presented development and preliminary testing of the high-precision long-stroke Slit Change Mechanism for the SPICE Instrument are considered fully successful such that future tests considering the full Slit Change Mechanism can be performed, with the gained confidence, directly on a Qualification Model. The selected linear Slit Change Mechanism design concept, consisting of a flexible guiding system driven by a hermetically sealed linear drive mechanism, is considered validated for the specific application of the SPICE instrument, with great potential for other special applications where contamination and high precision positioning are dominant design drivers.

Paciotti, Gabriel↗

Design and Demonstration of a NH3-Fueled Two-Stroke Uniflow Engine for Greenhouse Gas Reduction

The maritime shipping industry is growing increasingly interested in both low and non-carbon-containing fuels to meet future greenhouse gas emission targets. Specifically of interest is ammonia, as it has a relatively high volumetric energy density compared to other future fuels, such as hydrogen, making it more economical to transport. The robust engine architecture of low-speed two-stroke marine engines makes them an ideal candidate for ammonia fuel, overcoming many of the issues surrounding its poor ignitability and low flame speed. If emissions and fueling system challenges can be addressed, retrofits of current low-speed two-stroke dual-fuel engines represent a viable pathway for bringing ammonia engines to market. This study explores these technical hurdles by describing the design, analysis, and experimental validation of a single cylinder research engine converted to operate on ammonia fuel. The engine is a reduced-scale uniflow two-stroke marine engine with two previous hardware configurations available – diesel and high-pressure CNG dual-fuel. A concept study was used to evaluate possible ammonia-fueled engine architectures and the associated tradeoffs and design considerations. With the chosen architecture, low-pressure dual fuel, 1D and 3D analysis tools were used to inform hardware selection and to determine hardware configurations which minimized ammonia-slip. In addition to these considerations the hardware and engine configuration were designed to provide a versatile and robust testing platform. This includes options to test both gaseous and liquid ammonia injection, as well as a wide range of performance parameters such as AFR, swirl, valve timing, SOI, and many others. Design constraints imposed by the existing engine hardware necessitated an iterative loop between design and analysis toolsets, ultimately converging on a final design for the ammonia-conversion hardware. The engine was rebuilt with the new hardware and evaluated in an engine test cell. A new control strategy developed and flashed onto a prototyping electronic control unit allowed for full control over all engine parameters. An initial calibration was developed, providing test data for validation of the engine 1D and 3D models. The impact of the design choices on engine operability and the ability to meet program targets is discussed as well as opportunities for further optimization of the ammonia-conversion hardware, informed by the validated models.

Kaul, Brian [ORNL] (ORCID:0000000184813620)↗

Efficiency and emissions of NH3-diesel/bio-pilot dual-fuel combustion in a high-speed four-stroke engine

While dual-fuel ammonia engines are starting to be commercialized for the large low-speed 2-stroke marine engine market, there are still challenges with utilizing ammonia on 4-stroke engines used as auxiliary engines for ocean going vessels and within inland and coastal marine applications. The shorter timescales for high-speed engines pose a particular challenge for low-cetane, high ignition energy fuels like ammonia. In addition to achieving maximum ammonia substitution levels, N2O emissions are a key factor that needs to be understood. This paper reports the results of experiments using a single-cylinder 107mm bore Cummins B-series diesel engine modified for port-fuel injection of gaseous anhydrous ammonia with a direct injection of diesel fuel near-TDC to ignite the premixed ammonia. Combustion data as well as emissions data from an FTIR including NO, NO2, N2O, and unburned ammonia are presented for selected operating points with a focus on high-load operation at 1200rpm with high ammonia energy substitution (over 95% by fuel energy). Several air/fuel ratio conditions are included, sweeping from diesel-like airflow to stoichiometric conditions. The impact of biofuels (biodiesel and renewable diesel) as pilot fuels is also considered. Comparisons for emissions, greenhouse gas performance, and efficiency are made with a conventional diesel combustion baseline. The impact of fuel injection strategy on NOx, N2O, and NH3 emissions is quantified, and the dual-fuel ammonia results on this high-speed 4-stroke engine are expected to provide fundamental insights into further combustion development opportunities for the larger engines used across marine applications.

Kaul, Brian [ORNL] (ORCID:0000000184813620)↗

Development of a novel passive top-down uniflow scavenged two-stroke GDI engine

The design and performance characteristics of a novel top-down uniflow scavenged gasoline direct-injection two-stroke engine are presented. The novelty of the engine lies in the cylinder head that contains multiple check valves that control scavenging airflow into the cylinder from a supercharged air plenum. When the cylinder pressure drops below the intake plenum pressure during the expansion stroke, air flows into the cylinder through the check valves. During compression the cylinder pressure increases to a level above the intake plenum pressure and the check valves close preventing back-flow into the intake plenum. The engine head design provides asymmetrical intake valve timing without the use of poppet valves and the associated valve-train. In combination with an external Roots-type supercharger that supplies the plenum and exhaust ports at the bottom of the cylinder wall, the novel head provides top-down uniflow air scavenging. Motoring tests indicated that the check valves seal and the peak pressure is governed by the compression ratio. The only drawback observed is that valve closing is delayed as the engine speed increases. In order to investigate the valve dynamics, additional tests were performed in an optically-accessible cold flow test rig that enabled the direct measurement of valve opening and closing time under various conditions. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Terrestrial Gamma‐Ray Flash Following Intense Negative Return Stroke Observed With BIMAP‐3D

We report ground-based observations of a terrestrial gamma-ray flash (TGF) associated with a strong negative cloud-to-ground lightning strike (-CG) which occurred near Los Alamos National Laboratory (LANL) in New Mexico, USA. Gamma photons were detected by the Terrestrial High-energy Observations of Radiation (THOR) instrument, developed at the University of California, Santa Cruz, which has been hosted at LANL since 2022. Simultaneous measurements were also made with the 3-Dimensional Broadband Interferometric Mapping and Polarization (BIMAP-3D) system, which includes 3D lightning mapping, two fast antennas, and an additional plastic scintillator. Additional field change waveforms were obtained from the Earth Networks Total Lightning Network (ENTLN). The lightning initiated about 1 km above the ground, leading to a powerful -CG with an ENTLN peak current of −237 kA and bipolar field change matching the recently described “energetic compact stroke” (ECS) shape. The TGF was then observed ∼35 µs after the start of the return stroke. We also observe an electric field pulse likely produced by the TGF either in isolation or by coupling to the lightning channel. Based on modeling of the radiated electric field and photon propagation through the atmosphere we infer that the TGF source was on the order of 1⁢0 17 photons. This TGF and associated lightning are extremely similar to some recently reported ECS TGFs in coastal Japan in winter, but we report the first observation of this phenomenon outside of Japan in a different climate, terrain, and season.

58 GEOSCIENCES↗

Comparison of a Full-Scale and a 1:10 Scale Low-Speed Two-Stroke Marine Engine Using Computational Fluid Dynamics

International marine shipping is a growing component of international trade; a vast majority of all the world’s goods are being transported on large ocean-going vessels. The International Maritime Organization (IMO) introduced the Energy Efficiency Design Index in 2013, a regulatory framework of associated metrics for reducing emissions of CO 2 per tonne-mile from shipping by approximately 10% each decade. Therefore, decarbonizing the maritime sector requires the development of new fuel sources. Because of the extremely large physical size of the internal combustion engines present in shipping vessels, experimental iterative development of the engine and fuel system is cost-prohibitive. Thus, the ability to perform combustion system development in a scaled platform that can be more easily operated and modeled computationally is of interest. To that end, scaling relationships are needed to translate the results from a smaller engine to a larger counterpart. Scaling studies to date have been restricted to low scaling ratios, four-stroke light-duty engines, and under-resolved computational fluid dynamic simulations that likely do not accurately capture the physics of scaling. In this work, computational models of a 1:10 scale and a full-scale two-stroke crosshead low-speed marine engine were created and validated against experiments obtained in a real 1:10 scale engine installed at Oak Ridge National Laboratory. Further, due to the large size of the full-scale engine, the model required large high-performance computing resources to be evaluated. The availability of high-performance computing resources at the Department of Energy’s Leadership Computing Facilities is an enabler of the current work. The results of the small- and large-scale engine simulations were compared to analyze the effectiveness of the appropriate scaling laws under these extreme scaling ratio conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Modeling Dynamic Regulatory Processes in Stroke.

The ability to examine in silico the behavior of biological systems can greatly accelerate the pace of discovery in disease pathologies, such as stroke, where in vivo experimentation is lengthy and costly. In this paper we describe an approach to in silico examination of blood genomic responses to neuroprotective agents and subsequent stroke through the development of dynamic models of the regulatory processes observed in the experimental gene expression data. First, we identified functional gene clusters from these data. Next, we derived ordinary differential equations (ODEs) relating regulators and functional clusters from the data. These ODEs were used to develop dynamic models that simulate the expression of regulated functional clusters using system dynamics as the modeling paradigm. The dynamic model has the considerable advantage of only requiring an initial starting state, and does not require measurement of regulatory influences at each time point in order to make accurate predictions. The manipulation of input model parameters, such as changing the magnitude of gene expression, made it possible to assess the behavior of the networks through time under varying conditions. We report that an optimized dynamic model can provide accurate predictions of overall system behavior under several different preconditioning paradigms.

dynamic modeling↗

Contributions of MSNA and stroke volume to orthostatic intolerance following bed rest

We examined whether the altered orthostatic tolerance following 14 days of head-down tilt bed rest (HDBR) was related to inadequate sympathetic outflow or to excessive reductions in cardiac output during a 10- to 15-min head-up tilt (HUT) test. Heart rate, blood pressure (BP, Finapres), muscle sympathetic nerve activity (MSNA, microneurography), and stroke volume blood velocity (SVV, Doppler ultrasound) were assessed during supine 30 degrees (5 min) and 60 degrees (5-10 min) HUT positions in 15 individuals who successfully completed the pre-HDBR test without evidence of orthostatic intolerance. Subjects were classified as being orthostatically tolerant (OT, n = 9) or intolerant (OI, n = 6) following the post-HDBR test. MSNA, BP, and SVV during supine and HUT postures were not altered in the OT group. Hypotension during 60 degrees HUT in the post-bed rest test for the OI group (P < 0.05) was associated with a blunted increase in MSNA (P < 0.05). SVV was reduced following HDBR in the OI group (main effect of HDBR, P < 0.02). The data support the hypothesis that bed rest-induced orthostatic intolerance is related to an inadequate increase in sympathetic discharge that cannot compensate for a greater postural reduction in stroke volume.

NASA Discipline Musculoskeletal↗

Multiple Coaxial Catheter System for Reliable Access in Interventional Stroke Therapy

In some patients with acute cerebral vessel occlusion, navigating mechanical thrombectomy systems is difficult due to tortuous anatomy of the aortic arch, carotid arteries, or vertebral arteries. Our purpose was to describe a multiple coaxial catheter system used for mechanical revascularization that helps navigation and manipulations in tortuous vessels. A triple or quadruple coaxial catheter system was built in 28 consecutive cases presenting with acute ischemic stroke. All cases were treated by mechanical thrombectomy with the Penumbra System. In cases of unsuccessful thrombo-aspiration, additional thrombolysis or angioplasty with stent placement was used for improving recanalization. The catheter system consisted of an outermost 8-Fr and an intermediate 6-Fr guiding catheter, containing the inner Penumbra reperfusion catheters. The largest, 4.1-Fr, reperfusion catheter was navigated over a Prowler Select Plus microcatheter. The catheter system provided access to reach the cerebral lesions and provided stability for the mechanically demanding manipulations of thromboaspiration and stent navigation in all cases. Apart from their mechanical role, the specific parts of the system could also provide access to different types of interventions, like carotid stenting through the 8-Fr guiding catheter and intracranial stenting and thrombolysis through the Prowler Select Plus microcatheter. In this series, there were no complications related to the catheter system. In conclusion, building up a triple or quadruple coaxial system proved to be safe and efficient in our experience for the mechanical thrombectomy treatment of acute ischemic stroke.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Mechanical Recanalisation After Intravenous Thrombolysis in Acute Anterior Circulation Stroke: The Impact of a New Temporary Stent

Purpose: Treatment of acute stroke by endovascular mechanical recanalisation (EMR) has shown promising results and continues to be further refined. We evaluated the impact of a temporary stent compared with our results using other mechanical devices. Materials and Methods: We analysed clinical and radiological data of all patients who were treated by EMR after intravenous thrombolysis for acute carotid T- and middle-cerebral artery (M1) occlusions at our centre between 2007 and 2011. A comparison was performed between those patients in whom solely the stent-retriever was applied (group S) and those treated with other devices (group C). Results: We identified 14 patients for group S and 16 patients for group C. Mean age, National Institute of Health Stroke Scale score, and time to treatment were 67.1 years and 16.5 and 4.0 h for group S and 61.1 years and 17.6 and 4.5 h for group C, respectively. Successful recanalisation (thrombolysis in cerebral infarction scores {>=}IIb) was achieved in 93% of patients in group S and 56% of patients in group C (P < 0.05). Mean recanalisation times for M1 occlusions were 23 min (group S) and 29 min (group C) and for carotid-T occlusions were 39 min (group S) and 50 min (group C), and 45% of the patients in group S and 33% in group C had a favourable outcome (Modified Rankin Scale score {<=}2). Conclusion: The findings suggest an improvement in recanalisation success by the application of a temporary stent compared with previously used devices. These results are to be confirmed by larger studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Procedural Predictors of Outcome in Patients Undergoing Endovascular Therapy for Acute Ischemic Stroke

Purpose: To identify factors impacting outcome in patients undergoing interventions for acute ischemic stroke (AIS). Materials and Methods: This was a retrospective analysis of patients undergoing endovascular therapy for AIS secondary during a 30 month period. Outcome was based on modified Rankin score at 3- to 6-month follow-up. Recanalization was defined as Thrombolysis in myocardial infarction score 2 to 3. Collaterals were graded based on pial circulation from the anterior cerebral artery either from an ipsilateral injection in cases of middle cerebral artery (MCA) occlusion or contralateral injection for internal carotid artery terminus (ICA) occlusion as follows: no collaterals (grade 0), some collaterals with retrograde opacification of the distal MCA territory (grade 1), and good collaterals with filling of the proximal MCA (M2) branches or retrograde opacification up to the occlusion site (grade 2). Occlusion site was divided into group 1 (ICA), group 2 (MCA with or without contiguous M2 involvement), and group 3 (isolated M2 or M3 branch occlusion). Results: A total of 89 patients were studied. Median age and National Institutes of health stroke scale (NIHSS) score was 71 and 15 years, respectively. Favorable outcome was seen in 49.4% of patients and mortality in 25.8% of patients. Younger age (P = 0.006), lower baseline NIHSS score (P = 0.001), successful recanalization (P < 0.0001), collateral support (P = 0.0008), distal occlusion (P = 0.001), and shorter procedure duration (P = 0.01) were associated with a favorable outcome. Factors affecting successful recanalization included younger age (P = 0.01), lower baseline NIHSS score (P = 0.05), collateral support (P = 0.01), and shorter procedure duration (P = 0.03). An ICA terminus occlusion (P < 0.0001), lack of collaterals (P = 0.0003), and unsuccessful recanalization (P = 0.005) were significantly associated with mortality. Conclusion: Angiographic findings and preprocedure variables can help prognosticate procedure outcomes in patients undergoing endovascular therapy for AIS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recanalization and Mortality Rates of Thrombectomy With Stent-Retrievers in Octogenarian Patients with Acute Ischemic Stroke

BackgroundOur objective was to evaluate the effect of treatment with stent-retrievers in octogenarians suffering an acute ischemic stroke.MethodsA total of 150 consecutive patients with acute stroke who were treated with stent-retrievers between April 2010 and June 2012 were retrospectively reviewed. Patients were divided into those <80 years old (n = 116) and those ≥80 (n = 34). Baseline characteristics, procedure data, and endpoints (postprocedural NIHSS, death, and mRS at 3 months) were compared.ResultsHigh blood pressure, atrial fibrillation, and anticoagulation were more frequent in octogenarians (p = 0.01, 0.003, and 0.04 respectively). There were no differences between both groups regarding previous intravenous thrombolysis (32.4 vs. 48.3 %, p = 0.1), preprocedural NIHSS (18.1 vs. 16.8, p = 0.3), procedure time (74.5 (40–114) min vs. 63 (38–92) min, p = 0.2), revascularization time (380.5 (298–526.3) min vs. 350 (296.3–452.8), p = 0.3), TICI ≥ 2B (88.2 vs. 93.9 %, p = 0.1), and symptomatic haemorrhage (5.9 vs. 2.6 %, p = 0.3). Discharge NIHSS was higher in octogenarians (9.7 vs. 6.5, p = 0.03). Death and 3-month mRS ≥3 were more frequent in octogenarians (35.3 vs. 17.2 %, p = 0.02 and 73.5 vs. 37.1 %, p = 0.02). ICA-involvement and prolonged revascularization involved higher mortality (66.7 vs. 27.6 %, p = 0.03) and worse mRS (50 vs. 24.4 %, p = 0.06) in octogenarians.ConclusionsIn our series, treatment with stent-retrievers in octogenarians with acute ischemic stroke achieved good rates of recanalization but with a high mortality rate. ICA involvement and revascularization times beyond 6 hours associated to a worse prognosis. These data might be of value in the design of prospective studies evaluating the clinical efficacy of the endovascular treatments in octogenarians.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Stroke and Obstruction of the Extracranial Carotid Artery Combined with Intracranial Tandem Occlusion: Results of Interventional Revascularization

PurposeDue to high thrombus load, acute stroke patients with tandem obstructions of the extra- and intracranial carotid arteries or the middle cerebral artery show a very limited response to systemic thrombolysis. Interventional treatment with mechanical thrombectomy—often in combination with acute stenting of underlying atherosclerotic stenosis or dissection—is increasingly used. It has been shown that such complex interventions are technically feasible. The lack of optimal management strategies and clinical data encouraged us to review our acute stroke interventions in patient with anterior circulation tandem lesions to determine lesion patterns, interventional approaches, and angiographic or clinical outcomes.Patients and MethodsWe retrospectively analyzed a series of 39 consecutive patients with intracranial vessel occlusion of the anterior circulation simultaneously presenting with high-grade cervical internal carotid artery (ICA) stenosis or occlusion.ResultsEmergency ICA stent implantation was technically feasible in all patients, and intracranial recanalization with TICI ≥ 2b was reached in a large number of patients (64 %). Good clinical outcomes (mRS ≤ 2 at 3 months) were achieved in one third of the patients (36 %). Symptomatic hemorrhages occurred in four patients (10 %). Mortality was 10 %.ConclusionEndovascular recanalization of acute cervical carotid artery occlusion was technically feasible in all patients, and resulted in high extra- and intracranial revascularization rates. A trend for favorable clinical outcome was seen in a higher TICI score, younger age, good collateral status, and combined IV rTPA and endovascular therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

General Anesthesia Versus Conscious Sedation in Acute Stroke Treatment: The Importance of Head Immobilization

PurposeWhile today mechanical thrombectomy is an established treatment option for main branch occlusions in anterior circulation stroke, there is still an ongoing debate on the kind of anesthesia to be preferred. Introducing a simple method for head stabilization, we analyzed safety and duration of endovascular recanalization procedures under general anesthesia (GA) and conscious sedation (CS).MethodsWe retrospectively identified 84 consecutive patients who underwent mechanical thrombectomy owing to acute anterior circulation stroke. Fifty-three were treated under GA and 31 under CS equipped with a standard cervical collar to reduce head movement. We evaluated recanalization results, in-house time to start recanalization, procedure times, technical and clinical complication rates, and conversion rates from CS to GA.ResultsRecanalization of mTICI ≥2b was achieved in 80 % under CS and in 81 % under GA. Median in-house time to start recanalization for CS was 60 min (IQR 28; 44–72) and 77 min (IQR 23; 68–91) for GA (P = 0.001). Median procedure time under CS was 35 min (IQR 43; 69–25) and 41 min (IQR 43; 66–23) for GA (P = 0.9). No major complications such as ICH occurred in either group, and no conversions from CS to GA were necessary.ConclusionMechanical thrombectomy can be performed faster and safely under CS in combination with simple head immobilization using a standard cervical collar.

62 RADIOLOGY AND NUCLEAR MEDICINE↗