Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

An Evaluation of Oceanographic Optical Instruments and Deployment Methodologies

The primary objective of the Sea-viewing, Wide Field-of-view Sensor (SeaWiFS) Project is to produce water- leaving radiances with an uncertainty of 5% in clear-water regions and chlorophyll a concentrations within +/- 35% over the range of 0.05-50 mg/cu m. Any global mission, like SeaWiFS, requires validation data be submitted from a wide variety of investigators which places a significant challenge on quantifying the total uncertainty associated with the in situ measurements, because each investigator follows slightly different practices when it comes to implementing all of the steps associated with collecting field data, even those with a prescribed set of protocols. This study uses data from multiple cruises to quantify the uncertainties associated with implementing data collection procedures while utilizing differing in-water optical instruments and deployment methods. A comprehensive approach is undertaken and includes: (1) the use of a portable light source and in-water intercomparisons to monitor the stability of the field radiometers, (2) alternative methods for acquiring reference measurements, and (3) different techniques for making in-water profiles. The only system to meet the 5% radiometric objective of the SeaWiFS Project was a free-fall profiler using (relatively inexpensive) modular components, although a more sophisticated (and comparatively expensive) profiler using integral components was very close and only 1% higher. A relatively inexpensive system deployed with a winch and crane was also close, but the ship shadow contamination problem increased the total uncertainty to approximately 6.5%.

Hooker, Stanford B.↗

Efficacy Endpoints of Radiation Therapy Group Protocol 0247: A Randomized, Phase 2 Study of Neoadjuvant Radiation Therapy Plus Concurrent Capecitabine and Irinotecan or Capecitabine and Oxaliplatin for Patients With Locally Advanced Rectal Cancer

Purpose: To report secondary efficacy endpoints of Radiation Therapy Oncology Group protocol 0247, primary endpoint analysis of which demonstrated that preoperative radiation therapy (RT) with capecitabine plus oxaliplatin achieved a pathologic complete remission prespecified threshold (21%) to merit further study, whereas RT with capecitabine plus irinotecan did not (10%). Methods and Materials: A randomized, phase 2 trial evaluated preoperative RT (50.4 Gy in 1.8-Gy fractions) with 2 concurrent chemotherapy regimens: (1) capecitabine (1200 mg/m{sup 2}/d Monday-Friday) plus irinotecan (50 mg/m{sup 2}/wk × 4); and (2) capecitabine (1650 mg/m{sup 2}/d Monday-Friday) plus oxaliplatin (50 mg/m{sup 2}/wk × 5) for clinical T3 or T4 rectal cancer. Surgery was performed 4 to 8 weeks after chemoradiation, then 4 to 6 weeks later, adjuvant chemotherapy (oxaliplatin 85 mg/m{sup 2}; leucovorin 400 mg/m{sup 2}; 5-fluorouracil 400 mg/m{sup 2}; 5-fluorouracil 2400 mg/m{sup 2}) every 2 weeks × 9. Disease-free survival (DFS) and overall survival (OS) were estimated univariately by the Kaplan-Meier method. Local–regional failure (LRF), distant failure (DF), and second primary failure (SP) were estimated by the cumulative incidence method. No statistical comparisons were made between arms because each was evaluated individually. Results: A total of 104 patients (median age, 57 years) were treated; characteristics were similar for both arms. Median follow-up for RT with capecitabine/irinotecan arm was 3.77 years and for RT with capecitabine/oxaliplatin arm was 3.97 years. Four-year DFS, OS, LRF, DF, and SP estimates for capecitabine/irinotecan arm were 68%, 85%, 16%, 24%, and 2%, respectively. The 4-year DFS, OS, LRF, DF, and SP failure estimates for capecitabine/oxaliplatin arm were 62%, 75%, 18%, 30%, and 6%, respectively. Conclusions: Efficacy results for both arms are similar to other reported studies but suggest that pathologic complete remission is an unsuitable surrogate for traditional survival metrics of clinical outcome. Although it remains uncertain whether the addition of a second cytotoxic agent enhances the effectiveness of fluorouracil plus RT, these results suggest that further study of irinotecan may be warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Network Emulation Testbed Capabilities for Prototyping Space DTN Software and Protocols

This paper delves into network emulation tools essential for evaluating and designing Delay Tolerant Networking (DTN) protocols in space and satellite networking. It surveys and assesses the capability of current testbeds to create realistic test environments crucial for developing and evaluating DTN protocols. Specifically, this study provides a comprehensive overview of key DTN protocol stacks and related network emulation platforms and a detailed exploration of NASA’s research facilities. Finally, the paper underscores the fundamental emulation capabilities and the importance of a standardized framework for scenario creation, highlighting its vital role in evaluating and advancing future emulation platforms for space DTN.

Network Emulation and Simulation↗

Patient-based estimation of organ dose for a population of 58 adult patients across 13 protocol categories

Purpose: This study aimed to provide a comprehensive patient-specific organ dose estimation across a multiplicity of computed tomography (CT) examination protocols. Methods: A validated Monte Carlo program was employed to model a common CT system (LightSpeed VCT, GE Healthcare). The organ and effective doses were estimated from 13 commonly used body and neurological CT examination. The dose estimation was performed on 58 adult computational extended cardiac-torso phantoms (35 male, 23 female, mean age 51.5 years, mean weight 80.2 kg). The organ dose normalized by CTDI{sub vol} (h factor) and effective dose normalized by the dose length product (DLP) (k factor) were calculated from the results. A mathematical model was derived for the correlation between the h and k factors with the patient size across the protocols. Based on this mathematical model, a dose estimation iPhone operating system application was designed and developed to be used as a tool to estimate dose to the patients for a variety of routinely used CT examinations. Results: The organ dose results across all the protocols showed an exponential decrease with patient body size. The correlation was generally strong for the organs which were fully or partially located inside the scan coverage (Pearson sample correlation coefficient (r) of 0.49). The correlation was weaker for organs outside the scan coverage for which distance between the organ and the irradiation area was a stronger predictor of dose to the organ. For body protocols, the effective dose before and after normalization by DLP decreased exponentially with increasing patient's body diameter (r > 0.85). The exponential relationship between effective dose and patient's body diameter was significantly weaker for neurological protocols (r < 0.41), where the trunk length was a slightly stronger predictor of effective dose (0.15 < r < 0.46). Conclusions: While the most accurate estimation of a patient dose requires specific modeling of the patient anatomy, a first order approximation of organ and effective doses from routine CT scan protocols can be reasonably estimated using size specific factors. Estimation accuracy is generally poor for organ outside the scan range and for neurological protocols. The dose calculator designed in this study can be used to conveniently estimate and report the dose values for a patient across a multiplicity of CT scan protocols.

60 APPLIED LIFE SCIENCES↗

Field Immune Assessment during Simulated Planetary Exploration in the Canadian Arctic

Dysregulation of the immune system has been shown to occur during space flight, although the detailed nature of the phenomenon and the clinical risks for exploration class missions has yet to be established. In addition, the growing clinical significance of immune system evaluation combined with epidemic infectious disease rates in third world countries provides a strong rationale for the development of field-compatible clinical immunology techniques and equipment. In July 2002 NASA performed a comprehensive field immunology assessment on crewmembers participating in the Haughton-Mars Project (HMP) on Devon Island in the high Canadian Arctic. The purpose of the study was to evaluate mission-associated effects on the human immune system, as well as to evaluate techniques developed for processing immune samples in remote field locations. Ten HMP-2002 participants volunteered for the study. A field protocol was developed at NASA-JSC for performing sample collection, blood staining/processing for immunophenotype analysis, wholeblood mitogenic culture for functional assessments and cell-sample preservation on-location at Devon Island. Specific assays included peripheral leukocyte distribution; constitutively activated T cells, intracellular cytokine profiles and plasma EBV viral antibody levels. Study timepoints were L-30, midmission and R+60. The protocol developed for immune sample processing in remote field locations functioned properly. Samples were processed in the field location, and stabilized for subsequent analysis at the Johnson Space Center in Houston. The data indicated that some phenotype, immune function and stress hormone changes occurred in the HMP field participants that were largely distinct from pre-mission baseline and post-mission recovery data. These immune changes appear similar to those observed in Astronauts following spaceflight. The sample processing protocol developed for this study may have applications for immune assessment during exploration-class space missions or in remote terrestrial field locations. The data validate the use of the HMP as a ground-based spaceflight/planetary exploration analog for some aspects of human physiology.

Crucian, Brian↗

Experimental Benchmarking for High-Reproducibility, Cross-Institutional Evaluation of Iron Redox Electrochemistry

We present a practical case study standardizing experimental protocols between collaborators with the goal of understanding ferrous iron (Fe 2+ ) chemistry and improving the iron deposition reaction for energy-efficient, electrochemical iron production. The study of iron reactions can be difficult, as aqueous iron electrolytes exhibit complex behaviors that can lead to differing interpretation of ostensibly similar experiments. The question we want to answer: are we studying the same chemistry? Our protocols address inherent challenges such as the tendency for Fe 2+ to spontaneously oxidize to ferric iron (Fe 3+ ) and the production of hydrogen at the potentials of interest. Our standardized protocol, executed by four collaborators in different labs and institutions, yields high-reproducibility results, and identified glassy carbon electrode surface quality and Fe 3+ impurities in the salt as key factors with outsized effects on cyclic voltammetry measurements. The process of developing the protocols helped to troubleshoot underlying issues that created poorer reversibility and reproducibility. This study highlights the fact that even nominally straightforward electrochemical systems can yield vastly different outcomes due to small differences in experimental preparation and serves as a useful example for creating transparent and achievable standards for the generation of reliable datasets that can be widely used and shared.

Ketter, Benjamin [Argonne National Laboratory (ANL↗

In-situ/operando study of Cu-based nanocatalysts for CO 2 electroreduction using electrochemical liquid cell TEM

The structure of a nanocatalyst during electrocatalytic reactions often deviates from its pristine structure due to intrinsic properties, or physical and chemical adsorption at the catalytic surfaces. Taking Cu-based catalysts for CO 2 electroreduction reactions (CO 2 RR) as an example, they often experience segregation, leaching, and alloying during reactions. With the recent breakthrough development of high-resolution polymer electrochemical liquid cells, in-situ electrochemical liquid cell transmission electron microscopy (EC-TEM) alongside other advanced microscopy techniques, has become a powerful platform for revealing electrocatalysts restructuring at the atomic level. Considering the complex reactions involving electrified solid-liquid interfaces and catalyst structural evolution with intermediates, systematic studies with multimodal approaches are crucial. In this article, we demonstrate a research protocol for the study of electrocatalysts structural evolution during reactions using the in-situ EC-TEM platform. Using Cu and CuAg nanowire catalysts for CO 2 RR as model systems, we describe the experimental procedures and findings. We highlight the platform’s crucial role in elucidating atomic-scale pathways of nanocatalyst restructuring and identifying catalytic active sites, as well as avoiding potential artifacts to ensure unbiased conclusions. Using the multimodal characterization toolbox, we provide the opportunity to correlate the structure of a working catalyst with its performance. Finally, we discuss advancements as well as the remaining gap in elucidating the structural-performance relationship of working catalysts. We expect this article will assist in establishing guidelines for future investigations of complex electrochemical reactions, such as CO 2 RR and other catalytic processes, using the in-situ EC-TEM platform.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Practical Approach to Implementing Real-Time Semantics

This paper investigates implementations of process algebras which are suitable for modeling concurrent real-time systems. It suggests an approach for efficiently implementing real-time semantics using dynamic priorities. For this purpose a proces algebra with dynamic priority is defined, whose semantics corresponds one-to-one to traditional real-time semantics. The advantage of the dynamic-priority approach is that it drastically reduces the state-space sizes of the systems in question while preserving all properties of their functional and real-time behavior. The utility of the technique is demonstrated by a case study which deals with the formal modeling and verification of the SCSI-2 bus-protocol. The case study is carried out in the Concurrency Workbench of North Carolina, an automated verification tool in which the process algebra with dynamic priority is implemented. It turns out that the state space of the bus-protocol model is about an order of magnitude smaller than the one resulting from real-time semantics. The accuracy of the model is proved by applying model checking for verifying several mandatory properties of the bus protocol.

Luettgen, Gerald↗

NASA'S Standard Measures During Bed Rest: Adaptations in the Cardiovascular System

Bed rest is a well-accepted analog of space flight that has been used extensively to investigate physiological adaptations in a larger number of subjects in a shorter amount of time than can be studied with space flight and without the confounding effects associated with normal mission operations. However, comparison across studies of different bed rest durations, between sexes, and between various countermeasure protocols have been hampered by dissimilarities in bed rest conditions, measurement protocols, and testing schedules. To address these concerns, NASA instituted standard bed rest conditions and standard measures for all physiological disciplines participating in studies conducted at the Flight Analogs Research Unit (FARU) at the University of Texas-Medical Branch. Investigators for individual studies employed their own targeted study protocols to address specific hypothesis-driven questions, but standard measures tests were conducted within these studies on a non-interference basis to maximize data availability while reducing the need to implement multiple bed rest studies to understand the effects of a specific countermeasure. When possible, bed rest standard measures protocols were similar to tests nominally used for medically-required measures or research protocols conducted before and after Space Shuttle and International Space Station missions. Specifically, bed rest standard measures for the cardiovascular system implemented before, during, and after bed rest at the FARU included plasma volume (carbon monoxide rebreathing), cardiac mass and function (2D, 3D and Doppler echocardiography), and orthostatic tolerance testing (15- or 30-minutes of 80 degree head-up tilt). Results to-date indicate that when countermeasures are not employed, plasma volume decreases and the incidence of presyncope during head-up tilt is more frequent even after short-duration bed rest while reductions in cardiac function and mass are progressive as bed rest duration increases. Additionally, while plasma volume loss can be corrected and cardiac mass can be prevented with properly applied countermeasures, orthostatic tolerance is more difficult to protect when supine exercise is the only countermeasure. Similar results have been observed after space flight. Plasma volume, cardiac chamber volume, and orthostatic tolerance recover relatively quickly with resumption of ambulation and normal activity levels after bed rest but restoration of cardiac mass is prolonged.

Lee, Stuart M. C.↗

Electrical alternans during rest and exercise as predictors of vulnerability to ventricular arrhythmias

This investigation was performed to evaluate the feasibility of detecting repolarization alternans with the heart rate elevated with a bicycle exercise protocol. Sensitive spectral signal-processing techniques are able to detect beat-to-beat alternation of the amplitude of the T wave, which is not visible on standard electrocardiogram. Previous animal and human investigations using atrial or ventricular pacing have demonstrated that T-wave alternans is a marker of vulnerability to ventricular arrhythmias. Using a spectral analysis technique incorporating noise reduction signal-processing software, we evaluated electrical alternans at rest and with the heart rate elevated during a bicycle exercise protocol. In this study we defined optimal criteria for electrical alternans to separate patients from those without inducible arrhythmias. Alternans and signal-averaged electrocardiographic results were compared with the results of vulnerability to ventricular arrhythmias as defined by induction of sustained ventricular tachycardia or fibrillation at electrophysiologic evaluation. In 27 patients alternans recorded at rest and with exercise had a sensitivity of 89%, specificity of 75%, and overall clinical accuracy of 80% (p <0.003). In this patient population the signal-averaged electrocardiogram was not a significant predictor of arrhythmia vulnerability. This is the first study to report that repolarization alternans can be detected with heart rate elevated with a bicycle exercise protocol. Alternans measured using this technique is an accurate predictor of arrhythmia inducibility.

Clinical Trial↗

A Pilot Study for Applying an Extravehicular Activity Exercise Prebreathe Protocol to the International Space Station

Decompression sickness (DCS) is a serious risk to astronauts performing extravehicular activity (EVA). To reduce this risk, the addition of ten minutes of moderate exercise (75% VO2pk) during prebreathe has been shown to decrease the total prebreathe time from 4 to 2 hours and to decrease the incidence of DCS. The overall purpose of this pilot study was to develop an exercise protocol using flight hardware and an in-flight physical fitness cycle test to perform prebreathe exercise before an EVA. Eleven subjects volunteered to participate in this study. The first objective of this study was to compare the steady-state heart rate (HR) and oxygen consumption (VO2) from a submaximal arm and leg exercise (ALE) session with those predicted from a maximal ALE test. The second objective was to compare the steady-state HR and V02 from a submaximal elastic tube and leg exercise (TLE) session with those predicted from the maximal ALE test. The third objective involved a comparison of the maximal ALE test with a maximal leg-only (LE) test to conform to the in- flight fitness assessment test. The 75% VO2pk target HR from the LE test was significantly less than the target HR from the ALE test. Prescribing exercise using data from the maximal ALE test resulted in the measured submaximal values being higher than predicted VO2 and HR. The results of this pilot study suggest that elastic tubing is valid during EVA prebreathe as a method of arm exercise with the flight leg ergometer and it is recommended that prebreathe countermeasure exercise protocol incorporate this method.

Woodruff, Kristin K.↗

Assessing the Sensitivity of Pourbaix Diagrams to Computational Protocols: Electrochemical Stability of Ni Oxides as a Case Study

Pourbaix diagrams stand as a useful tool in assessing and visualizing materials’ electrochemical stability and are widely used for electrocatalyst design. However, their reliability hinges on the accuracy of the chemical potentials of involved phases, which may bear uncertainties and can be significantly impacted by decision-making steps in the computational protocol. Here, this study introduces a robust sensitivity analysis framework, exemplified through a detailed examination of the computational Pourbaix diagram of Ni, the oxides of which are used as high-activity and cost-friendly catalysts for many electrochemical reactions. Quantities of interest derived from the Pourbaix diagram include the appearance and stability domain of the catalytically active Ni oxide phases along with the onset electrochemical potentials of phase transitions. These metrics can guide the design of operational conditions for Ni oxide electrocatalysts. We find that the employed DFT exchange-correlation functional has the most significant influence on the computed Pourbaix diagram. Uncertainties on crystal structures, along with their related ab initio energetics, are also found to affect the size of the phase stability domain. Higher-order coupling among input parameters is found to play a crucial role in influencing the appearance and distribution of Ni phases in the diagram. Our findings suggest a need to consider variations and uncertainties associated with the computational procedures on predicted Pourbaix diagrams for materials design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High throughput structure–property relationship for additively manufactured 316L/IN625 alloy mixtures leveraging 2-step Bayesian estimation

While the fabrication of graded materials by directed energy deposition (DED) has led to accelerated materials discovery, the ability to rapidly explore sufficiently large material composition spaces is limited due to the time-intensive nature of conventional materials characterization techniques. The present study investigates the viability of small punch test (SPT) protocols for rapidly evaluating DED-fabricated alloy mixtures of stainless steel 316L (316L) and Inconel 625 (IN625). The SPT protocols evaluated in this study include both the recently established two-step Bayesian estimation framework as well as the empirical relationships established in prior literature. It is shown that these protocols are capable of reliably and quantitatively tracking the changes in the mechanical properties of the alloy mixtures studied. Enhancement of mechanical properties was observed with the addition of IN625 to 316L, which is attributed to the austenite stabilization in the matrix and the formation of fine δ - Ni3Nb precipitates. It is shown that CALPHAD-based Scheil model simulations predicted the formation of different precipitate phases for each composition. The novel protocols presented in this paper open new avenues for high throughput material explorations for additive manufacturing.

2-step Bayesian estimation↗

Influence of Pt-Metal Alloy Catalysts with Various Ionomers on Oxygen Reduction Reaction in Fuel Cell Application

Pt-M/C (M = Co, Ni, Mn, etc.) alloy catalysts exhibit superior oxygen reduction reaction (ORR) activity compared to pure Pt/C, leading to a high energy efficiency in hydrogen fuel cells. However, many Pt-M/C alloy catalysts were synthesized and evaluated at the lab scale in model test-bed systems like rotating disc electrodes, which don't always correlate to performance within a fuel cell system; there is a clear need to evaluate catalysts in electrodes that can be prepared at industrially relevant scales to evaluate how factors like ink formulation can greatly affect device-level of fuel cell performance. Herein, three commercial Pt-M/C alloy catalysts (two Pt-Co/C and one Pt-Ni/C) were comprehensively characterized by various techniques. The results show that the average particle sizes of the three catalysts are close to 5 nm; the atomic ratio of Pt/M is around 4; and the M was successfully embedded into Pt lattice, resulting in the positive shift of Pt 4f in XPS spectra and XRD patterns. These catalytic materials were incorporated into 9 different cathode catalyst layers (CCLs) with three kinds of ionomers (Nafion D2020, high oxygen permeability ionomer (HOPI), and Aquivion D79-25BS), and their performance in proton exchange membrane fuel cells (PEMFCs) were investigated. The results demonstrate that the Pt-Co/C catalysts possess a higher mass activity (MA) than Pt-Ni/C; the cathodes with Nafion ionomer provide the highest MA while electrodes with Aquivion ionomer showed the lowest activity, attributed to poor H+ conductivity resulting from suboptimal ionomer incorporation. Finally, these alloys were shown to exceed DOE targets for MA and H2/Air performance reported in the recent publications at beginning of life and after 90k cycle catalyst AST protocol. This study provides valuable performance benchmarks for these materials guiding future Pt-M/C catalyst design and material integration for heavy duty PEMFC applications.

08 HYDROGEN↗

SU-F-SPS-03: Direct Measurement of Organ Doses Resulting From Head and Cervical Spine Trauma CT Protocols

Purpose: This retrospective study analyzes the exposure history of emergency department (ED) patients undergoing head and cervical spine trauma computed tomography (CT) studies. This study investigated dose levels received by trauma patients and addressed any potential concerns regarding radiation dose issues. Methods: Under proper IRB approval, a cohort of 300 trauma cases of head and cervical spine trauma CT scans received in the ED was studied. The radiological image viewing software of the hospital was used to view patient images and image data. The following parameters were extracted: the imaging history of patients, the reported dose metrics from the scanner including the volumetric CT Dose Index (CTDIvol) and Dose Length Product (DLP). A postmortem subject was scanned using the same scan techniques utilized in a standard clinical head and cervical spine trauma CT protocol with 120 kVp and 280 mAs. The CTDIvol was recorded for the subject and the organ doses were measured using optically stimulated luminescent (OSL) dosimeters. Typical organ doses to the brain, thyroid, lens, salivary glands, and skin, based on the cadaver studies, were then calculated and reported for the cohort. Results: The CTDIvol reported by the CT scanner was 25.5 mGy for the postmortem subject. The average CTDIvol from the patient cohort was 34.1 mGy. From these metrics, typical average organ doses in mGy were found to be: Brain (44.57), Thyroid (33.40), Lens (82.45), Salivary Glands (61.29), Skin (47.50). The imaging history of the cohort showed that on average trauma patients received 26.1 scans over a lifetime. Conclusion: The average number of scans received on average by trauma ED patients shows that radiation doses in trauma patients may be a concern. Available dose tracking software would be helpful to track doses in trauma ED patients, highlighting the importance of minimizing unnecessary scans and keeping doses ALARA.

60 APPLIED LIFE SCIENCES↗

Breaking the reproducibility barrier with standardized protocols for plant–microbiome research

Inter-laboratory replicability is crucial yet challenging in microbiome research. Leveraging microbiomes to promote soil health and plant growth requires understanding underlying molecular mechanisms using reproducible experimental systems. In a global collaborative effort involving five laboratories, we aimed to help advance reproducibility in microbiome studies by testing our ability to replicate synthetic community assembly experiments. Our study compared fabricated ecosystems constructed using two different synthetic bacterial communities, the model grass Brachypodium distachyon, and sterile EcoFAB 2.0 devices. All participating laboratories observed consistent inoculum-dependent changes in plant phenotype, root exudate composition, and final bacterial community structure, where Paraburkholderia sp. OAS925 could dramatically shift microbiome composition. Comparative genomics and exudate utilization linked the pH-dependent colonization ability of Paraburkholderia, which was further confirmed with motility assays. The study provides detailed protocols, benchmarking datasets, and best practices to help advance replicable science and inform future multi-laboratory reproducibility studies.

Novak, Vlastimil↗

A Uniform Practice for Conceptualizing and Communicating Food‐Energy‐Water Nexus Studies

There is growing interest in nexus research: energy‐water, energy‐water‐land, and more recently food‐energy‐water. Motivating this movement is the recognition that the dynamics and feedbacks that constitute these nexuses have been overlooked in the past but are critical to the planning and management of these interacting elements. Formal reviews have identified gaps in current studies. In this commentary, we highlight additional oversights that are hindering integration of findings in nexus studies, notably usage of imprecise terminology to describe analyses, a failure to close the loop by linking production with corresponding waste streams, and exclusion of dynamics linking diverse constituent elements. Equally lacking from current nexus studies is a consistent protocol for communicating the conceptual basis of our studies. To fill this gap, we draw on diverse perspectives and fields to propose a comprehensive and systematic framework that can guide the model conceptualization phase of nexus studies. We also present a standardized documentation practice (similar to one utilized by the agent‐based modeling community) to facilitate communication of nexus studies. These initiatives can improve our ability to account for and communicate the nuanced, food‐energy‐water nexus interactions in a consistent manner, which is necessary to better inform risk analysis and avoid decisions with unintended consequences and hidden costs to society.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Two Methods for Noninvasive Determination of Stroke Volume During Orthostatic Challenge

Background: The real time, beat-by-beat, non-invasive determination of stroke volume (SV) is an important parameter in many aerospace related physiologic protocols. In this study, we compared simultaneous estimates of SV calculated from peripheral pulse waveforms with a more conventional non-invasive technique. Methods: Using a prospective, randomized blinded protocol, ten males and nine females completed 12-mm tilt table protocols. The relative change (%(Delta)) in beat-to-beat SV was estimated non-invasively from changes in pulse waveforms measured by application of infrared finger photoplethysmography (IFP) with a Portapres(Registered TradeMark) blood pressure monitoring device and by thoracic impedance cardiography (TIC). The %(Delta) SV values were calculated from continuous SV measurements in the supine posture and over the first 10 s (T1), second 10 s (T2), and 3.5 minutes (T3) of 80deg head-up tilt (HUT). Results: The average %(Delta) SV measured by IFP at T1 (-11.7 +/- 3.7 %) was statistically less (P <0.02) than the average %(Delta) SV measured by TIC at T1 (-21.7 +/- 3.1 %), while the average %(Delta) SV measured by 1FF at T2 (-16.2 +/- 3.9 %) and T3 (-19.1 +/- 3.8 %) were not statistically distinguishable (P > or = 0.322) than the average %(Delta) SV measured by TIC at T2 (-21.8 +/- 2.5 %), and T3 (-22.6 +/- 2.9 %). Correlation coefficients (r(sup 2)) between IFP and TIC were 0.117 (T1), 0.387 (T2), and 0.7 18 (T3). Conclusion: IFP provides beat-to-beat (real time) assessment of %(Delta) SV after 20 sec of transition to an orthostatic challenge that is comparable to the commonly accepted TIC. Our data support the notion that IFP technology which has flown during space missions can be used to accurately assess physiological status and countermeasure effectiveness for orth static problems that may arise in astronauts after space flight. While the peripherally measured IFP response is slightly delayed, the ease of implementing this monitor in the field is advantageous.

Doerr, Donald F.↗