Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

System and method for using mechanical loading to create spatially patterned meta surfaces for optical components

The present disclosure relates to a system for producing a patterned nanostructured surface on a component from a pre-existing, nanostructured surface with a first spatial feature distribution on the component. The system makes use of a force application element configured to apply a force to the pre-existing, nanostructured surface, and a force application control subsystem. The force application control subsystem is configured to control elevational movement of the force application element along a first axis of movement into and out of contact with the pre-existing, nanostructured surface to apply a predetermined load to the pre-existing, nanostructured surface. The predetermined load is sufficient to modify the pre-existing, non-patterned nanostructured surface to create the patterned nanostructured surface.

Ray, Nathan James↗

Contamination Effects on EUV Optics

During ground-based assembly and upon exposure to the space environment, optical surfaces accumulate both particles and molecular condensibles, inevitably resulting in degradation of optical instrument performance. Currently, this performance degradation (and the resulting end-of-life instrument performance) cannot be predicted with sufficient accuracy using existing software tools. Optical design codes exist to calculate instrument performance, but these codes generally assume uncontaminated optical surfaces. Contamination models exist which predict approximate end-of-life contamination levels, but the optical effects of these contamination levels can not be quantified without detailed information about the optical constants and scattering properties of the contaminant. The problem is particularly pronounced in the extreme ultraviolet (EUV, 300-1,200 A) and far (FUV, 1,200-2,000 A) regimes due to a lack of data and a lack of knowledge of the detailed physical and chemical processes involved. Yet it is in precisely these wavelength regimes that accurate predictions are most important, because EUV/FUV instruments are extremely sensitive to contamination.

Tveekrem, J.↗

Contamination Control Considerations for the Next Generation Space Telescope (NGST)

The NASA Space Science Program, in its ongoing mission to study the universe, has begun planning for a telescope that will carry on the Hubble Space Telescope's exploration. This telescope, the 'Next Generation Space Telescope' (NGST), will be 6-8 meters in diameter, will be radiatively cooled to 30-60 Kelvin in order to enable extremely deep exposures at near infrared wavelengths, and will operate for a lifetime of 5-10 years. The requirement will be to measure wavelengths from 1-5 microns, with a goal to measure wavelengths from 0.6-30 microns. As such, NGST will present a new contamination control challenge. The Goddard Space Flight Center (GSFC) performed one of three preliminary feasibility studies for the NGST, presenting a telescope with an 8 meter, deployable primary mirror and a deployable secondary mirror. The telescope would be radiatively cooled, with the optical telescope assembly (OTA) and the science instrument module (SIM) isolated from the warmer spacecraft support module (SSM). The OTA and the SIM would also be shielded from sunlight with an enormous, inflatable sun-shield. The GSFC telescope was designed for launch on an Atlas HAS, which would require launching the telescope in a stowed configuration, with the SSM, antennae, sun-shield, primary mirror 'petals', and secondary mirror deployed once on-orbit. The launch configuration and deployment scenario of an exposed telescope measuring near infrared and cooled to 30-60 K are the factors presenting contamination hazards to the NGST mission. Preliminary science requirements established are: less than 20% reflectance decrease on optical surfaces over the wavelength range, and less than 0.3% obscuration of optical surfaces. In order to meet these requirements, NGST must be built and launched with careful attention to contamination control. Initial contamination control design options include strict selecting of materials and baking out of hardware down to the component level, minimizing or eliminating exposure of the OTA to sunlight or earth albedo during deployment and early on-orbit operations, cleaning of the primary and secondary mirrors at the launch site, cleaning of the launch vehicle fairing, locating thrusters and vents on the warm side of the sun shield only, and the possibility of including a deployable cover if that is shown to be necessary.

Wooldridge, Eve M.↗

A review of contamination issues associated with an orbiting Space Station external environment

Techniques for measuring, modeling, and limiting the effluent contamination of external spacecraft and instrument surfaces are reviewed, with an emphasis on their application to the Space Station. The major factors addressed by contamination studies are outlined; typical contamination sources are characterized; the critical measurement parameters are defined (molecular column density, background spectral intensity from UV to IR, particle size and velocity distribution, molecular deposition on ambient and cryogenic surfaces, molecular return flux for gaseous species, particulate deposition on surfaces, and optical-surface degradation); and measurement instrumentation is described. Contamination limits for quiescent operation periods of the Space Station are proposed, including column density 10 to the 11th/sq cm for H2O + CO2, 10 to the 13th/sq cm for O2 + N2, and 10 to the 10th/sq cm for other species; particle release no greater than 15-micron particle/orbit/0.00001 sr FOV for a 1-m telescope, and surface deposition 4 pg/sq cm sec for 298-K surfaces and 10 pg/sq cm sec for 4-K surfaces.

Smith, A. C.↗

An optical multipass radiation system (OMRS) for heating levitated samples

The present system for spaceborne containerless material sample heating uses lamp systems with heating efficiencies of the order of 65 percent, potentially producing 30 W/sq mm over areas of 0.3 sq cm. The effectiveness of these lamp systems has its basis in the 'multipassing' of the lamp beams to recycle fluxes not absorbed by the sample during the initial pass. The actual multipass system's performance will have a power-law dependence on the quality of the coatings and optical surfaces illuminated; a detailed study of the spectral and dichroic characteristics, surface-scattering, and optical figure specifications of the system must be completed for full characterization.

Morrow, W. H.↗

Contamination and Radiation Effects on Nonlinear Crystals for Space Laser Systems

Space Lasers are vital tools for NASA s space missions and military applications. Although, lasers are highly reliable on the ground, several past space laser missions proved to be short-lived and unreliable. In this communication, we are shedding more light on the contamination and radiation issues, which are the most common causes for optical damages and laser failures in space. At first, we will present results based on the study of liquids and subsequently correlate these results to the particulates of the laser system environment. We present a model explaining how the laser beam traps contaminants against the optical surfaces and cause optical damages and the role of gravity in the process. We also report the results of the second harmonic generation efficiency for nonlinear optical crystals irradiated with high-energy beams of protons. In addition, we are proposing to employ the technique of adsorption to minimize the presence of adsorbing molecules present in the laser compartment.

Abdeldayem, Hossain A.↗

Development and Testing of Molecular Adsorber Coatings

The effect of on-orbit molecular contamination has the potential to degrade the performance of spaceflight hardware and diminish the lifetime of the spacecraft. For example, sensitive surfaces, such as optical surfaces, electronics, detectors, and thermal control surfaces, are vulnerable to the damaging effects of contamination from outgassed materials. The current solution to protect these surfaces is through the use of zeolite coated ceramic adsorber pucks. However, these pucks and its additional complex mounting hardware requirements result in several disadvantages, such as size, weight, and cost related concerns, that impact the spacecraft design and the integration and test schedule. As a result, a new innovative molecular adsorber coating was developed as a sprayable alternative to mitigate the risk of on-orbit molecular contamination. In this study, the formulation for molecular adsorber coatings was optimized using various binders, pigment treatment methods, binder to pigment ratios, thicknesses, and spray application techniques. The formulations that passed coating adhesion and vacuum thermal cycling tests were further tested for its adsorptive capacity. Accelerated molecular capacitance tests were performed in an innovatively designed multi-unit system containing idealized contaminant sources. This novel system significantly increased the productivity of the testing phase for the various formulations that were developed. Work performed during the development and testing phases has demonstrated successful application of molecular adsorber coatings onto metallic substrates, as well as, very promising results for the adhesion performance and the molecular capacitance of the coating. Continued testing will assist in the qualification of molecular adsorber coatings for use on future contamination sensitive spaceflight missions.

Abraham, Nithin↗

In situ measurements of scattering from contaminated optics in the Vacuum Ultraviolet

NASA's In Situ Contamination Effects Facility has been used to measure the time dependence of the angular reflectance from molecularly contaminated optical surfaces in the vacuum ultraviolet. The light scattering measurements are accomplished in situ on optical surfaces in real time during deposition of molecular contaminants. The measurements are taken using noncoherent VUV sources with the predominant wavelengths being the krypton resonance lines at 1236 and 1600 angstroms. Detection of the scattered light is accomplished using a set of three solar blind VUV photomultipliers. An in-plane VUV BRDF (bidirectional reflectance distribution function) experiment is described and details of the on-going program to characterize optical materials exposed to the space environment is reported.

Herren, Kenneth A.↗

Designing a Decontamination Solution for the Low-Earth-Orbit, Cryogenic SPHEREx Mission

To address the scientific goals of NASA’s astrophysics division, the JPL and Caltech’s SPHEREx mission conducts the first near-infrared all-sky spectral survey in low-earth-orbit using a passively-cooled, cryogenic telescope. Several unique water contamination issues arise due to the combination of cryogenic operation temperatures and the limited temperature control authority of passive cooling. Because water molecules have adsorption bands within the wavelengths of interest for SPHEREx’s survey, it is imperative that water contamination be controlled and minimized. In this work, a model is developed for the SPHEREx mission to predict the transport and accumulation of outgassed water onto sensitive payload components. The model utilizes the time dependent thermal profiles of the individual payload components, initial water content, and spacecraft geometry to calculate the time dependent water diffusion, transport, and adsorption. This model is subsequently used to predict water contamination risks and design decontamination solutions for each risk. Two major water contamination risks were predicted, water accumulation during cooldown and on cryogenic surfaces during the mission. The first risk occurs during the cooldown of the payload to cryogenic temperatures, predicting water accumulation on optical surfaces in excess of the allowable levels. To mitigate this accumulation, the temperature of the optical surfaces is controlled during cooldown through a combination of heaters and spacecraft pointing. The second risk is that over the course of the mission, is unavoidable water accumulation onto the payload thermal system’s cryogenic surfaces, possibly jeopardizing thermal performance and temperature stability, both of which are required for science success. To decontaminate any water that had collected onto cryogenic thermal system surfaces, a decontamination maneuver was designed. In this decontamination maneuver, cryogenic surfaces of the thermal system are warmed to a temperature where water will desorb by spacecraft pointing while still meeting all avoidance constraints, and thereby avoiding undue risk to the observatory hardware. Through application of the developed analytical model and inclusion of the decontamination maneuver in the mission design, SPHEREx can confidently demonstrate that it is able to decontaminate, at the start of and during the mission as needed to meet its end of life science performance requirements.

Soares, Carolos E.↗

Design principles for contamination abatement in scientific satellites.

It is shown that deposition of contamination films on satellite optics can be controlled by the following means: isolating critical optical surfaces from the rest of the spacecraft; avoiding or minimizing the use of nonmetallic material, particularly near or in line of sight of optical surfaces; avoiding materials with high vapor pressures; subjecting materials to vacuum baking prior to use, to drive off the volatile outgassing products; keeping the critical surfaces at temperatures above the ambient; avoiding elevated operational temperatures for nonmetallic materials; paying special attention to optics exposed to intense UV-, X-ray, or particular radiation; avoiding water-vapor sources; and directing RCS plumes away from critical surfaces. Methods of controlling particulate contaminants are also proposed.

Naumann, R. J.↗

Contamination study

The time dependence of the angular reflectance from molecularly contaminated optical surfaces in the Vacuum Ultraviolet (VUV) is measured. The light scattering measurements are accomplished in situ on optical surfaces in real time during deposition of molecular contaminants. The measurements are taken using non-coherent VUV sources with the predominant wavelengths being the Krypton resonance lines at 1236 and 1600 A. Detection of the scattered light is accomplished using a set of three solar blind VUV photomultipliers. An in-plane VUV BRDF (Bidirectional Reflectance Distribution Functions) experiment is described and details of the ongoing program to characterize optical materials exposed to the space environment is reported.

Johnson, R. Barry↗

Selection of Optical Cavity Surface Coatings for 1micron Laser Based Missions

The particulate surface cleanliness level on several coatings for aluminum and beryllium substrates were examined for use in the optical cavities of high pulse energy Nd:YAG Q-switched, diode-pumped lasers for space flight applications. Because of the high intensity of the lasers, any contaminants in the laser beam path could damage optical coatings and limit the instrument mission objectives at the operating wavelength of 1 micron (micrometer). Our goal was to achieve an EST-STD-CC1246D Level 100 particulate distribution or better to ensure particulate redistribution during launch would not adversely affect the performance objectives. Tapelifts were performed to quantify the amount of particles using in-house developed procedures. The primary candidate coatings included chromate conversion coating aluminum (Al), uncoated Al electroless Nickel (Ni) on Al, Ni-gold (Au) on Al, anodized Al, and gold (Au)/Ni on Beryllium (Be). The results indicate that there were advantages in Ni and Au coating applications for the two major substrates, Al and Be, when considering applications that need to meet launch environments.

Hedgeland, Randy J.↗

E-PVT: enhanced position-velocity-time scheduler for computer-controlled optical finishing with comprehensive considerations of dynamics constraints, continuity and efficiency

Deterministic computer-controlled optical finishing is an essential approach for achieving high-quality optical surfaces. Its determinism and convergence rely heavily on precise and smooth motion control to guide the machine tool over an optical surface to correct residual errors. One widely supported and smooth motion control model is position-velocity-time (PVT), which employs piecewise cubic polynomials to describe positions. Our prior research introduced a PVT-based velocity scheduling method, demonstrating sub-nanometer level convergence in ion beam figuring (IBF) processes. However, three challenges remained. Firstly, this method relies on quadratic programming, resulting in computational intensiveness for dense tool paths. Secondly, the dynamics constraints and velocity and acceleration continuities are not comprehensively considered, limiting the full potential of PVT-based control. Thirdly, no compensation mechanism existed when dynamics constraints are exceeded. In this study, in response to these challenges, we proposed the Enhanced PVT (E-PVT) method, reducing the time complexity from O ( n 3 ) to O ( n ) while fully addressing dynamics constraints and continuities. A novel compensation method utilizing particle swarm optimization was proposed to address situations where dynamics constraints might be exceeded while maintaining the overall processing efficiency. Validation through simulation and experimentation confirmed the improved performance of E-PVT.

36 MATERIALS SCIENCE↗

An Induced Environment Contamination Monitor for the Space Shuttle

The Induced Environment Contamination Monitor (IECM), a set of ten instruments integrated into a self-contained unit and scheduled to fly on shuttle Orbital Flight Tests 1 through 6 and on Spacelabs 1 and 2, is described. The IECM is designed to measure the actual environment to determine whether the strict controls placed on the shuttle system have solved the contamination problem. Measurements are taken during prelaunch, ascent, on-orbit, descent, and postlanding. The on-orbit measurements are molecular return flux, background spectral intensity, molecular deposition, and optical surface effects. During the other mission phases dew point, humidity, aerosol content, and trace gas are measured as well as optical surface effects and molecular deposition. The IECM systems and thermal design are discussed. Preflight and ground operations are presented together with associated ground support equipment. Flight operations and data reduction plans are given.

Miller, E. R.↗

COI Structural Analysis Presentation

This report discusses the structural analysis of the Next Generation Space Telescope Mirror System Demonstrator (NMSD) developed by Composite Optics Incorporated (COI) in support of the Next Generation Space Telescope (NGST) project. The mirror was submitted to Marshall Space Flight Center (MSFC) for cryogenic testing and evaluation. Once at MSFC, the mirror was lowered to approximately 40 K and the optical surface distortions were measured. Alongside this experiment, an analytical model was developed and used to compare to the test results. A NASTRAN finite element model was provided by COI and a thermal model was developed from it. Using the thermal model, steady state nodal temperatures were calculated based on the predicted environment of the large cryogenic test chamber at MSFC. This temperature distribution was applied in the structural analysis to solve for the deflections of the optical surface. Finally, these deflections were submitted for optical analysis and comparison to the interferometer test data.

Cline, Todd↗

Ultra-Compact Imaging Spectrometer Moon (UCIS-Moon) For Lunar Surface Missions: Optical, Optomechanical, and Thermal Design

The Ultra-Compact Imaging Spectrometer Moon (UCIS-Moon) instrument is an imaging spectrometer designed for integration with a lander or rover for lunar surface science missions. Operating over a 600-3600 nm spectral range with 10 nm sampling and 1.15 mrad IFOV, UCIS-Moon is capable of detecting spectral absorptions from common lunar minerals, OH species, molecular H2O, water ice, organics, and placing mineral identifications within an established geologic context at the cm to m scale. We present an instrument design capable of surviving the harsh lunar environment in the daytime with temperatures as high as 370 K, while providing high-quality spectral data.

Mouroulis, Pantazis↗

Method for Texturing Surfaces of Optical Fiber Sensors Used for Blood Glucose Monitoring

Disclosed is a method and the resulting product thereof comprising a solid light-conducting fiber with a point of attachment and having a textured surface site consisting a textured distal end prepared by being placed in a vacuum and then subjected to directed hyperthermal beams comprising oxygen ions or atoms. The textured distal end comprises cones or pillars that are spaced upon from each other by less than 1 micron and are extremely suitable to prevent cellular components of blood from entering the valleys between the cones or pillars so as to effectively separate the cellular components in the blood from interfering with optical sensing of the glucose concentration for diabetic patients.

Banks, Bruce A.↗