Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchrotron beamline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Long Island Steatite Sourcing from Rhode Island Quarries During the Late Holocene Era

This study aimed to investigate the possible sourcing of Long Island steatite artifacts from quarries in Rhode Island. Seven steatite samples from archeological sites on Long Island including Nassau County, Suffolk County (North Fork and South Fork) and Shelter Island were compared to two Rhode Island quarry sample putative sources using X-ray fluorescence (XRF) microscopy at the Submicron Resolution X-ray spectroscopy (SRX) beamline of the National Synchrotron Light Source II at Brookhaven National Laboratory. The site-derived steatite samples displayed numerous similarities in elemental composition compared to the two Rhode Island quarries, Oaklawn and Ochee Springs. This study provides new evidence to support the possible sourcing of Long Island steatite from Rhode Island during the late Holocene era.

54 ENVIRONMENTAL SCIENCES↗

Long Island Steatite Sourcing from Rhode Island Quarries During the Late Holocene Era

This study aimed to investigate the possible sourcing of Long Island steatite artifacts from quarries in Rhode Island. Seven steatite samples from archeological sites on Long Island including Nassau County, Suffolk County (North Fork and South Fork) and Shelter Island were compared to two Rhode Island quarry sample putative sources using X-ray fluorescence (XRF) microscopy at the Submicron Resolution X-ray spectroscopy (SRX) beamline of the National Synchrotron Light Source II at Brookhaven National Laboratory. The site-derived steatite samples displayed numerous similarities in elemental composition compared to the two Rhode Island quarries, Oaklawn and Ochee Springs. This study provides new evidence to support the possible sourcing of Long Island steatite from Rhode Island during the late Holocene era.

54 ENVIRONMENTAL SCIENCES↗

Formation of Insoluble Organic Material from the Ultraviolet Irradiation of Laboratory Ice Photolysis Residues

We present preliminary results from the study of ice photolysis residues which were exposed to ultraviolet (UV)/extreme UV (EUV) photon radiation. The residues were produced from the simultaneous deposition and UV irradiation of ice mixtures of astrophysical interest (H2O, CH3OH, CO, NH3, without/with N2 and/or O2, and without/with small quantities of aromatic compounds) at 15–20 K using an H2 lamp, which emits 10.2-eV (121.6 nm) Lyman-α photons and a continuum at 7.5–8 eV (155–165 nm). After warm-up to room temperature and subsequent sublimation of volatile compounds, the refractory materials (residues) recovered at room temperature were analyzed with infrared (IR) microscopy and then further irradiated with UV/EUV photons at a synchrotron facility, on a beamline providing a broad-band photon beam in the 4–45-eV range with a ~1016 photons s-1 flux.2 The residues were UV/EUV irradiated with increasing photon doses ranging from ~1018 to ~1021 photons, i.e., covering 4 orders of magnitude and relevant to those experienced by ice-coated grains in the protosolar nebula.1. After UV/EUV irradiation, residues were analyzed with IR microscopy and the data compared to those before irradiation to identify changes in chemical composition as a function of the photon dose. UV/EUV-irradiated residues were also analyzed with other techniques such as nanoscale secondary-ion mass spectrometry (nanoSIMS) to the study the changes in isotopic composition, and scanning transmission electron microscopy to look at variations in structure and C bonding distribution. Results will be compared with data from extraterrestrial materials, in particular, meteoritic insoluble organic material (IOM) and interplanetary dust particles (IDPs).

Ices↗

Thallium Bromide Semiconductor Radiation Materials and Detectors Characterization Studies

Two overarching requirements of crucial importance for the commercial and scientific establishment of semiconductor radiation detectors are: (1) exceptionally high-purity crystals with impurity concentrations less than 1 part-per-billion and (2) single crystals that are relatively free from subgrain boundaries, secondary phases, dislocations, and other electrically-active defects. We investigated the properties of thallium bromide (TlBr) material that affect its performance with the goal of increasing the material's commercial viability for radiation detection applications. For this purpose, we used beamlines at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL), performing Micron-scale X-ray Detector Mapping, White Beam X-ray Diffraction Topography, and Micron-scale X-ray Fluorescence. These characterization methods improve the industry's understanding of TlBr and lead to the production of improved instrumentation. In this particular study we report electro-migration measurements of positive-ion Cu, Ag, and Au impurities in TlBr detectors under electric field strengths typically used for device operation. BNL improved TlBr detectors with an electrode design that corrects the response non-uniformities caused by crystal defects. This design can achieve improved energy resolution while using typical-grade, commercial crystals with relaxed quality requirements, thus reducing the overall cost of detectors. Additional characterization will be necessary to fully understand the structure and performance of TlBr with the ultimate goal to achieve the highest energy resolution. Our findings from past work will be presented along with our recommendations for additional investigation.

36 MATERIALS SCIENCE↗

In situ chamber for studying battery failure using high-speed synchrotron radiography

The investigation of lithium-ion battery failures is a major challenge for personnel and equipment due to the associated hazards (thermal reaction, toxic gases and explosions). To perform such experiments safely, a battery abuse-test chamber has been developed and installed at the microtomography beamline ID19 of the European Synchrotron Radiation Facility (ESRF). The chamber provides the capability to robustly perform in situ abuse tests through the heat-resistant and gas-tight design for flexible battery geometries and configurations, including single-cell and multi-cell assemblies. High-speed X-ray imaging can be complemented by supplementary equipment, including additional probes (voltage, pressure and temperature) and thermal imaging. Together with the test chamber, a synchronization graphical user interface was developed, which allows an initial interpretation by time-synchronous visualization of the acquired data. Enabled by this setup, new meaningful insights can be gained into the internal processes of a thermal runaway of current and future energy-storage devices such as lithium-ion cells.

25 ENERGY STORAGE↗

Solution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource

We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [FeII(phen)3]2+, a prototypical spin crossover complex that undergoes light-induced excited spin state trapping forming an electronic excited state with a 0.6–0.7 ns lifetime. In addition, we report transient Fe Kβ main line and valence-to-core x-ray emission spectra, showing a unique detection sensitivity and an excellent agreement with model spectra and density functional theory calculations, respectively. Notably, the achieved signal-to-noise ratio, the overall performance, and the routine availability of the developed end-station have enabled a systematic time-resolved science program using the monochromatic beam at the Stanford Synchrotron Radiation Lightsource.

47 OTHER INSTRUMENTATION↗

Wave optics simulations for new soft x-ray beamlines at NSLS-II

In this work, we performed fully- and partially-coherent synchrotron emission and propagation simulations with the "Synchrotron Radiation Workshop" computer code to analyze the performance of two soft X-ray beamlines under development at the National Synchrotron Light Source II: Soft X-ray Nanoprobe (SXN), and Angle-Resolved Photoemission Spectroscopy (ARPES) and Resonant Inelastic X-ray Scattering (RIXS) Imaging (ARI). The SXN beamline intends to provide high flux and high spatial resolution coherent soft X-ray imaging capabilities using both zone plate and lensless coherent imaging techniques. The ARI beamline aims to perform high flux ARPES and RIXS experiments with a focal spot size at the sample approaching 100 nm using highly-demagnifying mirrors in Kirkpatrick-Baez geometry. To accurately calculate the resolution and the degree of X-ray coherence provided by the two state-of-the-art beamlines, partial coherence effects are required to be taken into account in wave optics simulations for these two beamlines. In this talk, beamline performance parameters such as spot size, degree of coherence, flux, and energy resolution at the sample are presented. The effects of mirror surface slope errors on beamline performance were studied and some suggestions for further optimization are discussed.

36 MATERIALS SCIENCE↗

Toward a fully coherent tender and hard X-ray free-electron laser via cascaded EEHG in fourth-generation synchrotron light sources

Free-electron-laser-based beamlines utilize fully coherent laser pulses with extremely narrow bandwidth allowing direct use of X-rays without monochromators. This could be very beneficial for all users of current and future fourth-generation diffraction-limited synchrotron light sources (DL-SLSs) who need narrowband full-coherence high-brightness X-ray pulses. Based on our previous finding, i.e. that separating the two stages of echo-enabled harmonic generation (EEHG) with a few extra bending-magnet sections provides an effective way to increase the momentum compaction of chicane 1, one can simultaneously achieve adequate prebunching at extremely high harmonics as well as keep the energy modulation to the ideal minimum. This could open the door for cascaded EEHG, toward fully coherent tender and hard X-ray wavelengths. Built on our compact design of a twin-pulse seeding electron beam with an adjustable delay and timing jitter at the level of a few femtoseconds, a cascaded EEHG can be implemented, which includes two EEHG beamlines, where the radiation pulse generated by the first beamline with harmonic $h$ 1 could be used as the input seed laser pulse to the second beamline with harmonic $h$ 2 . Hence, the second radiator could potentially reach very high harmonics [$h$ = $h$ 1 (20)$h$ 2 (25–100)] from 500 to 2000, corresponding to tender and hard X-ray wavelengths. It is demonstrated that the cascaded EEHG scheme is compatible with almost any current or planned fourth-generation DL-SLS, with significant benefits for space-limited storage rings in particular. The main advantage is that this scheme requires almost no change of the storage-ring lattice and is fully compatible with other beamlines. Current proposals for rings with much longer straight sections would add self-amplified spontaneous emission as another viable option for storage-ring-based free-electron lasers.

36 MATERIALS SCIENCE↗

GPU Acceleration in SRW: Design and Considerations

Synchrotron Radiation Workshop (SRW) is a powerful tool for simulation synchrotron radiation emission and propagation through beamline elements, enabling advanced beamline design and experimental optimization. Recently, GPU acceleration has been developed for SRW to support highly detailed end-to-end simulations of experiments at synchrotron light sources. This work documents the design and implementation of this GPU acceleration support, addressing the complexities of adapting CPU-based components to heterogeneous computing architectures.

43 PARTICLE ACCELERATORS↗

A simple wire-coil resistive heater for high temperature radial x-ray diffraction in a diamond anvil cell

Diamond anvil cells are commonly used at synchrotron x-ray diffraction beamlines to study structural and thermoelastic properties of materials at high pressures. In a radial geometry, where the x-ray probe is oriented perpendicular to the axis of force, the deformation and strength of materials can be measured in situ. Because the anelastic and failure properties of materials depend strongly on temperature, many applications would benefit from the ability to measure high pressure radial diffraction in elevated and accurately controlled thermal environments. Previous work to introduce high temperature to radial diamond anvil cells has been largely limited to laser heating, with relatively scant efforts to resistively heat the sample. Here, we report a relatively straightforward adaptation of a simple wire coil heater, with in situ high-temperature radial diffraction performed on tungsten carbide up to 573 K at beamline 12.2.2 of the Advanced Light Source. In conclusion, the results demonstrate that the differential stress supported by WC decreases with increasing temperature: the differential stress on the basal (001) and pyramidal (101) planes decreased 6.6% and 5.5%, respectively, while the (100) plane only saw a 2.7% decrease, in agreement with previous studies.

Diamond anvil cells↗

Optical design and efficiency measurement of an extreme ultraviolet high-resolution spectrometer for unresolved transition array research

Understanding the structures of the unresolved transition array (UTA) observed in extreme ultraviolet (EUV) spectra from many-electron atoms is crucial for various applications, including fusion science and nanolithography. Here, to measure the fine structure of the UTA from tungsten and tin at around 5 and 13.5 nm at the Tokyo electron beam ion trap, we developed a high-resolution EUV spectrometer. The designed spectrometer achieves a resolving power of λ/dλ > 5000 at 5 and 13.5 nm. The fabricated large-area grating was experimentally examined at beamline BL5B of the UVSOR synchrotron facility to evaluate the diffraction efficiencies and their variation across the ruled area. The measured diffraction efficiencies are 0.65% ± 0.07% at 5 nm (second order) and 7.9% ± 0.2% at 13.5 nm (first order). The variation in the diffraction efficiency across the ruled area is 2.2%, 13.6%, and 10.0% in zeroth, first, and second order diffractions, respectively. The discrepancies in diffraction efficiencies between the experiments and the calculations were 5.2%, 29%, and 35% for the zeroth, first, and second diffraction orders, respectively.

47 OTHER INSTRUMENTATION↗

Autonomous x-ray scattering

Autonomous experimentation (AE) is an emerging paradigm that seeks to automate the entire workflow of an experiment, including—crucially—the decision-making step. Beyond mere automation and efficiency, AE aims to liberate scientists to tackle more challenging and complex problems. We describe our recent progress in the application of this concept at synchrotron x-ray scattering beamlines. We automate the measurement instrument, data analysis, and decision-making, and couple them into an autonomous loop. We exploit Gaussian process modeling to compute a surrogate model and associated uncertainty for the experimental problem, and define an objective function exploiting these. We provide example applications of AE to x-ray scattering, including imaging of samples, exploration of physical spaces through combinatorial methods, and coupling to in situ processing platforms These uses demonstrate how autonomous x-ray scattering can enhance efficiency, and discover new materials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Autonomous discovery of emergent morphologies in directed self-assembly of block copolymer blends

The directed self-assembly (DSA) of block copolymers (BCPs) is a powerful approach to fabricate complex nanostructure arrays, but finding morphologies that emerge with changes in polymer architecture, composition, or assembly constraints remains daunting because of the increased dimensionality of the DSA design space. Here, we demonstrate machine-guided discovery of emergent morphologies from a cylinder/lamellae BCP blend directed by a chemical grating template, conducted without direct human intervention on a synchrotron x-ray scattering beamline. This approach maps the morphology-template phase space in a fraction of the time required by manual characterization and highlights regions deserving more detailed investigation. These studies reveal localized, template-directed partitioning of coexisting lamella- and cylinder-like subdomains at the template period length scale, manifesting as previously unknown morphologies such as aligned alternating subdomains, bilayers, or a “ladder” morphology. This work underscores the pivotal role that autonomous characterization can play in advancing the paradigm of DSA.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Efficiency measurements of reflection gratings in the 100-300-A band

Zero-order and first-order efficiencies of plane diffraction grazings over the 100-300-A band have been measured using the NRL beamline facility at the National Synchrotron Light Source. Measurements were taken at grating angles of 5, 10, and 15 deg, and the incident radiation was polarized primarily in the transverse magnetic mode. Four (three laminar, one blazed) of the gratings were ion etched in high quality quartz blanks, overcoated with 200 A of gold. A fifth (blazed) grating was ruled in gold. The line densities are 1000, 2000, and 3600 grooves/mm for those with laminar profiles. Both blazed gratings have a blaze angle of 8 deg and line densities of 3600 grooves/mm. Measured first-order efficiencies up to 15 percent were obtained for the laminar gratings and up to 8 percent was obtained for the ion-etched blazed grating. Much lower efficiencies (not greater than 2 percent) were measured for the ruled grating. A computer program was written to calculate grating efficiencies using a full electromagnetic model. Measured efficiencies of the ion-etched gratings agree well with predicted values, but the measured first-order efficiency of the ruled grating is much lower than predicted.

Meekins, John F.↗

Hard X-ray Fluorescence measurements with TESs at the Advanced Photon Source

Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20keV energy range. We are building a TES-based instrument for time Advanced Photon Source (APS) synchrotron, to be made available to beamline users. 24-pixel prototype arrays have recently been fabricated and tested. the first, spectroscopy measurements using these arrays are promising, with a best single-pixel energy resolution of 11.2 eV and saturation energy > 20 keV. We present a series of recent X-ray Fluorescence measurements involving transition metal elements and multi-element samples with closely spaced emission lines, in particular a Cu-Ni-Co thin film and a foil of Cu and Hf, The TES-measured spectra are directly compared to spectra measured with silicon drift detectors at an APS beamline, demonstrating the improved X-ray science made possible by TES spectrometers.

Guruswamy, Tejas↗

In-situ synchrotron X-ray study on microstructure and stress evolutions of electroplated copper upon self-annealing

Background: The self-annealing behavior of electroplated copper (Cu) at room temperature is gaining attention in the microelectronics industry due to its significant impact on reliability issues such as substrate warpage and electrical resistivity. Methods: In this study, in-situ analysis of the microstructure transition and stress relaxation of the electroplated copper upon self-annealing was conducted via synchrotron white X-ray nanodiffraction (beamline 21A, Taiwan Photon Source) and grazing-incidence X-ray diffraction (beamline 17B1, Taiwan Light Source). Significant Findings: Remarkable relaxations of deviatoric stress and absolute strain component along the [002] direction were closely related to the Cu grain growth and crystallographic reorientation at the early stage of selfannealing, and a complete stress/strain relaxation can be achieved with the cessation of microstructure transition. In conclusion, the in-situ synchrotron X-ray studies provided an insight into Cu self-annealing mechanism, offering valuable information for improving Cu interconnect reliability.

Cu Self-annealing↗

pyXPCSviewer : an open-source interactive tool for X-ray photon correlation spectroscopy visualization and analysis

pyXPCSviewer , a Python-based graphical user interface that is deployed at beamline 8-ID-I of the Advanced Photon Source for interactive visualization of XPCS results, is introduced. pyXPCSviewer parses rich X-ray photon correlation spectroscopy (XPCS) results into independent PyQt widgets that are both interactive and easy to maintain. pyXPCSviewer is open-source and is open to customization by the XPCS community for ingestion of diversified data structures and inclusion of novel XPCS techniques, both of which are growing demands particularly with the dawn of near-diffraction-limited synchrotron sources and their dedicated XPCS beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗