Search NASA⌕ Search

SEARCH · Search NASA

Results for “system noise temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

433 micron laser heterodyne observations of galactic CO from Mauna Kea

A submillimeter heterodyne radiometer, developed for astronomical applications, uses an optically pumped laser local oscillator and a quasi-optical Schottky diode mixer. The resultant telescope-mounted system, which has a noise temperature less than 4000 K (double sideband) and high frequency and spatial resolution, has been used to detect the J = 6 to 5 rotational transition of carbon monoxide at 434 micrometers in the Orion molecular clouds. The measurements, when compared with previous millimeter-wave data, indicate that the broad carbon monoxide emission feature is produced by an optically thin gas whose temperature exceeds 180 K.

Buhl, D.↗

The development of performance, interference, sharing and coordination criteria

The criteria for sharing and coordination between the Earth Exploration Satellite service and other radio services is not fully developed at this time. The purpose is to develop a plan showing how the necessary criteria might be developed. Some criteria does exist in the form of general restrictions, protection criteria, and coordination procedures for space and terrestrial services sharing the same bands. Determining suitable criteria for EES bands depends on the use of the band and the shared services. For example the criteria developed for EES passive sensing band will be developed in a manner different than for a telemetry band. In either case the resultant criteria will be related to, and can be referenced from the system noise power or equivalent noise temperature.

Tillotson, Tom↗

The challenges and opportunities of supersonic transport propulsion technology

The major challenges confronting the propulsion community for civil supersonic transport applications are identified: high propulsion system efficiency at both supersonic and subsonic cruise conditions, low-cost fuel with adequate thermal stability at high temperatures, low noise cycles and exhaust systems, low emission combustion systems, and low drag installations. Both past progress and future opportunities are discussed in relation to perceived technology shortfalls for an economically successful airplane that satisfies environmental constraints.

Strack, William C.↗

The challenges and opportunities of supersonic transport propulsion technology

The major challenges confronting the propulsion community for civil supersonic transport applications are identified: high propulsion system efficiency at both supersonic and subsonic cruise conditions, low-cost fuel with adequate thermal stability at high temperatures, low noise cycles and exhaust systems, low emission combustion systems, and low drag installations. Both past progress and future opportunities are discussed in relation to perceived technology shortfalls for an economically successful airplane that satisfies environmental constraints.

Strack, William C.↗

Performance of the X-/Ka/KABLE-band dichroic plate in the DSS-13 beam waveguide antenna

The first Ka-band downlink demonstration was recently carried out by the Ka-Band Link Experiment (KABLE) in association with the Mars Observer spacecraft. In order to support the mission, a dichroic plate was required in the DSS-13 beam waveguide antenna to allow simultaneous X- and Ka-band operation. An X-/ Ka-/ KABLE-band dichroic plate was designed to transmit Ka-band downlink (31.8-32.3 GHz), Ka-band uplink (34.2-34.7 GHz), and KABLE (33.6-33.8 GHz) frequencies, while reflecting X-band (8.4-8.5 GHz). A computer program was developed for the analysis of a dichroic plate with rectangular apertures by using the mode-matching method. The plate was then fabricated and tested. The reflection, group delay, and noise temperature in the antenna system due to the dichroic plate were measured. The experimental results show good agreement with theoretical prediction.

Chen, J. C.↗

Two-Band, Low-Loss Microwave Window

A window for a high-sensitivity microwave receiving system allows microwave radiation to pass through to a cryogenically cooled microwave feed system in a vacuum chamber, while keeping ambient air out of the chamber and helping to keep the interior of the chamber cold. The microwave feed system comprises a feed horn and a low-noise amplifier, both of which are required to be cooled to a temperature of 15 K during operation. The window is designed to exhibit very little microwave attenuation in two frequency bands: 8 to 9 GHz and 30 to 40 GHz. The window is 15 cm in diameter. It includes three layers (see figure): 1) The outer layer is made of a poly(tetrafluoroethylene) film 0.025 mm thick. This layer serves primarily to reflect and absorb solar ultraviolet radiation to prolong the life of the underlying main window layer, which is made of a polyimide that becomes weakened when exposed to ultraviolet. The poly(tetrafluoroethylene) layer also protects the main window layer against abrasion. Moreover, the inherent hydrophobicity of poly(tetrafluoroethylene) helps to prevent the highly undesirable accumulation of water on the outer surface. 2) The polyimide main window layer is 0.08 mm thick. This layer provides the vacuum seal for the window. 3) A 20-mm-thick layer of ethylene/ propylene copolymer foam underlies the main polyimide window layer. This foam layer acts partly as a thermal insulator: it limits radiational heating of the microwave feed horn and, concomitantly, limits radiational cooling of the window. This layer has high compressive strength and provides some mechanical support for the main window layer, reducing the strength required of the main window layer. The ethylene/propylene copolymer foam layer is attached to an aluminum window ring by means of epoxy. The outer poly(tetrafluoroethylene) film and the main polyimide window layer are sandwiched together and pressed against the window ring by use of a bolted clamp ring. The window has been found to introduce a microwave loss of only about 0.4 percent. The contribution of the window to the noise temperature of the microwave feed system has been found to be less than 1 K at 32 GHz and 0.2 K at 8.4 GHz.

Britcliffe, Michael↗

Ultra Stable Microwave Radiometers for Future Sea Surface Salinity Missions

The NASA Earth Science System Pathfinder (ESSP) mission Aquarius will measure global sea surface salinity with 100-km spatial resolution every 8 days with an average monthly salinity accuracy of 0.2 psu (parts per thousand). This requires an L-band low-noise radiometer with the long-term calibration stability of less than 0.1 K over 8 days. This three-year research program on ultra stable radiometers has addressed the radiometer requirements and configuration necessary to achieve this objective for Aquarius and future ocean salinity missions. The system configuration and component performance have been evaluated with radiometer testbeds at both JPL and GSFC. The research has addressed several areas including component characterization as a function of temperature, a procedure for the measurement and correction for radiometer system non-linearity, noise diode calibration versus temperature, low noise amplifier performance over voltage, and temperature control requirements to achieve the required stability. A breadboard radiometer, utilizing microstrip-based technologies, has been built to demonstrate this long-term stability. This report also presents the results of the radiometer test program, a detailed radiometer noise model, and details of the operational switching sequence optimization that can be used to achieve the low noise and stability requirements. Many of the results of this research have been incorporated into the Aquarius radiometer design and will allow this instrument to achieve its goals.

sea surface salinity↗

Temperature control of silica mirrors for cryogenically-cooled telescopes in space

The SIRTF (Space Infrared Telescope Facility) optical subsystem, including the primary mirror, has been modeled using lumped-parameter techniques and a thermal and cryogenic transient analysis program developed previously. Since silica mirrors have been shown to have significantly less distortion due to cryogenic cooldown, a silica primary mirror of approximately 1 m diameter is being considered. Thermal responses to variations in aperture heat load and heat sink temperature have been explored. Calculations have been made of system noise components from primary mirror spatial and temporal temperature variations. Background-limited infrared observations can be made at wavelengths out to 200 micrometers. Mirror thermal performance with and without copper wires for cooling is also considered.

Melugin, R. K.↗

Phased array feed design technology for Large Aperture Microwave Radiometer (LAMR) Earth observations

An assessment of the potential and limitations of phased array antennas in space-based geophysical precision radiometry is described. Mathematical models exhibiting the dependence of system and scene temperatures and system sensitivity on phased array antenna parameters and components such as phase shifters and low noise amplifiers (LNA) are developed. Emphasis is given to minimum noise temperature designs wherein the LNA's are located at the array level, one per element or subarray. Two types of combiners are considered: array lenses (space feeds) and corporate networks. The result of a survey of suitable components and devices is described. The data obtained from that survey are used in conjunction with the mathematical models to yield an assessment of effective array antenna noise temperature for representative geostationary and low Earth orbit systems. Practical methods of calibrating a space-based, phased array radiometer are briefly addressed as well.

Schuman, H. K.↗

Ultimate temperature stability of a magnetic refrigerator

In recent years there has been an interest in using adiabatic demagnetization refrigeration in space to cool bolometers to the 0.1-0.3 K temperature range. Two different demagnetization schemes have been proposed for such refrigerators. Both methods start the same way: an isothermal magnetization followed by an adiabatic demagnetization. Once the operating temperature is reached, the two methods differ. The first method uses feedback control to perform an isothermal demagnetization. As reported, this system is limited by the resolution of the analog-to-digital converter used. While the stability of this system is the best reported to date (0.5 mK at 200 mK for 14 h), it is several orders of magnitude worse than the theoretical limit. The second method uses a complete demagnetization and allows the temperature to drift up uncontrolled. This system has the disadvantage that the responsivity and noise of a bolometer will also drift, and so will require continuous recalibration. There is some concern that fluctuations in the temperature control system of the first method would adversely affect the bolometer performance by increasing the system noise. The purpose of this note is to present the ultimate stability limit of an isothermal demagnetization feedback control system.

Kittel, P.↗

Low-noise receivers: S-band parametric up converter development

The combination of a cryogenically-cooled parametric upconverter and a higher frequency maser post amplifier was proposed as a method of achieving maser-like receiver noise temperatures over much larger instantaneous bandwidths and tuning ranges than are presently obtainable with masers in the range of 1 to 18 GHz. An experimental 2.0- to 2.5-GHz parametric upconverter/maser system was developed to explore these possibilities. Initial tests of this system resulted in an effective input noise temperature of 3.1 K at 2295 MHz and 3.2 K at 2388 MHz. The parametric upconverter logged over 1500 hours at 4.5 K and underwent 5 thermal cycles (300 K to 4.5 K to 300 K) without degradation.

Petty, S.↗

Ultra-stable, low phase noise dielectric resonator stabilized oscillators for military and commercial systems

EPSD has designed, fabricated and tested, ultra-stable, low phase noise microwave dielectric resonator oscillators (DRO's) at S, X, Ku, and K-bands, for potential application to high dynamic range and low radar cross section target detection radar systems. The phase noise and the temperature stability surpass commercially available DROs. Low phase noise signals are critical for CW Doppler radars, at both very close-in and large offset frequencies from the carrier. The oscillators were built without any temperature compensation techniques and exhibited a temperature stability of 25 parts per million (ppm) over an extended temperature range. The oscillators are lightweight, small and low cost compared to BAW & SAW oscillators, and can impact commercial systems such as telecommunications, built-in-test equipment, cellular phone and satellite communications systems. The key to obtaining this performance was a high Q factor resonant structure (RS) and careful circuit design techniques. The high Q RS consists of a dielectric resonator (DR) supported by a low loss spacer inside a metal cavity. The S and the X-band resonant structures demonstrated loaded Q values of 20,300 and 12,700, respectively.

Mizan, Muhammad↗

Analysis of DSN PPM support during Voyager 2 Saturn encounter

The precision power monitor (PPM) is a precision radiometric instrument used to improve the efficiency of signal reception by the Deep Space Network. Real time estimates of the system operating temperature, the present (signal + noise)-to-noise ratio, and the signal power are utilized to increase the accuracy and resolution of the received spacecraft signal. Due to the critical nature of radio science data returning from Voyager 2 at Saturn Encounter, PPM support was required. The task was undertaken to validate the performance of equipment technically under research and development in time to meet the encounter deadline. Initial studies revealed PPM performance to be out of tolerance. Action was immediately taken to identify the system problems. Using data analysis as feedback, the system failures were identified and corrected in time to contribute to the encounter support efforts. As a result, the radio science data were collected successfully.

Bartok, C. D.↗

Signal separator for dual-frequency antenna

Replacement for dichroic plate reduces noise. Besides being easier to install, flange is less expensive to fabricate. Most important, the flange reduces antenna contribution to system noise; whereas, dichroic plate increases noise temperature by 2 or 3 degrees.

Hartop, R. W.↗

Radiometric tests on wet and dry antenna reflector surface panels

The results of X-band noise temperature tests on two types of antenna surface panels are presented. The first type tested was a solid antenna panel, while the second type was a perforated panel with 3/16-in.-diameter holes. Measurements were made at 8.45 GHz using an X-band radiometric system. Included in this article are measured noise temperature contributions from: (1) thermal diffusive white paint on solid and perforated panels, and (2) water sprayed on both painted and unpainted perforated panels. Experiments on perforated panels were restricted to the 3/16-in.-diameter hole panels formerly used on Deep Space Network 64-m antennas. Rigorous calibration equations, applicable to a variety of antenna panel and dichroic plate test configurations, are presented. It was demonstrated that an accurate, stable radiometric measurement system of the type used for the results of this research makes it possible to obtain information that would be much more difficult to obtain using other techniques.

Otoshi, T. Y.↗

Model of aircraft passenger acceptance

A technique developed to evaluate the passenger response to a transportation system environment is described. Reactions to motion, noise, temperature, seating, ventilation, sudden jolts and descents are modeled. Statistics are presented for the age, sex, occupation, and income distributions of the candidates analyzed. Values are noted for the relative importance of system variables such as time savings, on-time arrival, convenience, comfort, safety, the ability to read and write, and onboard services.

Jacobson, I. D.↗