Search NASA⌕ Search

SEARCH · Search NASA

Results for “technology validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

High-Fidelity Computational Studies of Intermediate Pressure Capacitively Coupled Plasmas

This report discussed progress made in the development of a computational model for intermediate pressure capacitively coupled plasma discharge. A new full fidelity argon chemistry model has been developed that includes electron, argon ion, three lumped states for electronically excited species, and the background ground state argon. As such the mechanism has been validated over a wide range of intermediate pressure conditions from 100 mTorr to a few Torr. Uncertainties in the electron impact cross sections and the rate coefficients for the reactions are propagated through the model to establish uncertainties that emerge in the model due the reaction mechanism and its impact on the discharge properties. The model is therefore validated in face of uncertainties.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status Update of Permanent Magnet Radiation Resiliency Studies at CEBAF

The proposed energy upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) incorporates Fixed-Field Alternating-gradient (FFA) arcs utilizing permanent magnet technology. Given the radiation environment within the CEBAF tunnel enclosure, validating the long-term magnetic stability of these materials is a critical step for the project's technical feasibility. This contribution presents an overview of the ongoing permanent magnet radiation resiliency program at Jefferson Lab. We briefly review the experimental methodology used to monitor demagnetization in situ and summarize the operational experience from the initial data-taking campaign. Furthermore, we discuss the upgrades implemented for the second exposure campaign, currently underway, which aims to refine dose correlation and reduce systematic uncertainties. We report on the general status of the program and the roadmap for certifying permanent magnet optics for the proposed upgrade energies.

Bodenstein, R. [Thomas Jefferson National Accelera↗

Identifying Nuclear Data Correlated Through Predicting Bias in Integral Experiments via Applying Principal Component Analysis to Random Forest

ABSTRACT Nuclear data (ND) are the input data for neutron‐transport simulations to answer questions related to nuclear technologies. Subsets of ND, here > 20,000 data points, are validated with respect to thousands of criticality experiments that represent various applications on a small scale. The aim of validation with these experiments is to find errors in ND or methods. The key challenge here is that several hundreds of ND are used to simulate one integral value. Hence, one cannot clearly identify what ND are leading to bias in criticality measurements. In fact, a mistake in one nuclear‐data observable can be compensated with an error in another, and the predicted criticality value would still be predicted in agreement with experimental data. Random forest (RF) was previously employed to predict bias in criticality measurements using sensitivities of simulated criticality experiments to ND. The SHapley Additive exPlanations (SHAP) metric was then applied to attribute the importance of each ND experiment and observable to bias prediction. This, however, did not highlight what ND were jointly related to predicting bias. This is important as it could inform us about where compensating errors in ND could hide. We tackle this shortcoming here by first decomposing the ND sensitivities to integral‐experiment simulations into principal components. Then we use principal component projections to predict bias via the RF and SHAP. The SHAP values and principal components are employed to reconstruct detailed SHAP values for each ND observable. We demonstrate that these extended SHAP bias predictions are more robust, less noisy, and more efficient. In addition, we show that this approach accounts for covariance in ND sensitivities and automates the identification of where compensating errors could hide in ND.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiphysics Simulation of KRUSTY Warm Critical Experiments Using MOOSE Tools

A series of critical experiments were performed during the Kilopower Reactor Using Stirling TechnologY (KRUSTY) project, producing valuable and unique data for the validation of corresponding microreactor models. In this paper, the development of a high-fidelity multiphysics model of the KRUSTY microreactor within the MOOSE ecosystem is presented, with a focus on the microreactor configuration during the warm critical experiments. The model was established by coupling a deterministic neutronics model using the Griffin code, with a BISON thermomechanical model. The multiphysics model successfully simulated the KRUSTY 15 ¢ and 30 ¢ warm critical reactivity insertion experiments in satisfactory agreement with the experimental measurement data. In conclusion, the modeling results demonstrated the performance of MOOSE-based multiphysics tools in microreactor simulations, and spotlighted the useful applications of these tools in supporting microreactor design, qualification, and licensing activities.

KRUSTY↗

Development and Test of a Large Aperture $Nb_3Sn$ Cos-Theta Dipole Coil with Stress Management

An innovative stress-management (SM) concept for cos-theta (CT) coils (SMCT coil concept) has been proposed at Fermilab. A large-aperture two-layer Nb3Sn SMCT dipole coil was designed and manufactured to validate and test the SM concept including coil design, fabrication technology, and performance. The first large-aperture SMCT coil (SMCT1) was fabricated and assembled with a small-aperture Nb3Sn coil inside a dipole mirror magnet. SMCT1 coil tests in a dipole mirror structure was performed in two configurations - SMCTM1a with only powered two-layer SMCT1 coil and SMCTM1b with the SMCT coil connected in series with an inner two-layer dipole coil. The test goals are to prove the SMCT coil concept in two-layer and four-layer mirror configurations; demonstrate that the magnet can reach the targeted quench current at the established preload; study magnet training, training memory after thermal cycle, ramp rate and temperature dependences of the magnet quench current; and test the SMCT1 coil quench protection parameters. This paper summarizes the SMCT1 coil design and parameters, the coil main fabrication steps, its assembly in the dipole mirror structure. The results of the SMCTM1a/b mirror test are presented and discussed.

43 PARTICLE ACCELERATORS↗

X-ray Security Imaging on Personal Dosimetry [Slides]

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

SPARC - Plans for a New Critical Experiment Facility with a Horizontal Split Table

Several critical experiment facilities, sometimes referred to as zero power reactor facilities, have provided crucial data to aid understanding and validate nuclear-physics models since the beginning of nuclear technology. Indeed, the first man-made reactor, Chicago Pile-1, was essentially this type of reactor. However, there was a downturn in nuclear technology development toward the turn of the millennium, and the need for these specialized research facilities waned. Now there are few of these experimental facilities operational in the world and those that remain have relatively small critical assembly machines. The need for criticality safety benchmark experiments at intermediate neutron energy levels and the modern resurgence of interest in advanced reactors designs, many of which do not have historical precedents in terms of nuclear fuel composition, moderator, and coolant combinations, all combine to create a substantial need for a critical experiment facility with a large horizontal split-table (HST) machine. A HST machine is used to arrange two separate and subcritical parts of a core assembly, bring them together in a precise manner to achieve criticality using remote controls, and separate them to achieve a subcritical configuration again. A new effort was recently performed to develop user needs for a HST, assess candidate locations at the Idaho National Laboratory (INL), and develop a plan for deployment. This project is referred to as the System Physics Advanced Reactor Critical facility (SPARC). A few months after this assessment began, and shortly after as a viable pathway was emerging, a series of important presidential executive orders were issued to revitalize nuclear energy in the United States (U.S.). The relevance of SPARC to these executive orders was immediately apparent. The far-reaching potential of SPARC to these executive orders will reside in its ability to produce data which facilitates licensing of advanced nuclear reactor designs while reducing uncertainties to help increase energy production alongside new criticality safety data to enable more efficient nuclear fuel manufacture, transport, and storage.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Intern Sized Poster for Dosimetry Research

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intern Sized Poster for Dosimetry Research

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray Security Imaging on Personal Dosimetry

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

Verification and Validation of Open-Source Computational Fluid Dynamics Capabilities in MOOSE

The Multiphysics Object Oriented Simulation Environment (MOOSE) advances predictive modeling in nuclear research by simplifying the application design process and making modeling more efficient and accessible to researchers and the broader community. Because of MOOSE’s critical role in the scientific computation field, verification and validation are important to evaluate the reliability and credibility of MOOSE’s code, simulations, and models. To assess MOOSE’s Navier Stokes module and turbulence models, the following verification and validation University of Manchester ERCOFTAC cases were simulated in MOOSE, and the results were compared: Case 032 Turbulent Flow in a 2D Channel Case 079 Natural Convection in an Enclosed Cavity

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Dynamic modeling of heat pipe integrated thermal battery latent heat storage system experiment validation

A heat pipe integrated thermal battery system has been constructed to investigate a high-temperature latent heat thermal energy storage technology that takes advantage of near isothermal operation of latent heat storage and heat pipes to potentially enable high-energy isothermal heat storage. A dynamic model constructed in Modelica has been validated, showing errors between 2.5 °C–39.7 °C across 10-h to 47-h simulations against experiment results, showing good prediction capability of experiment output, especially against phase change time. Model calibrations showing vessel heat-up capability of 3 kW and heat pipes combining to provide 600 W each during experiment operation validate experiment circumstances including reduced material loading and reduced power capability. The experiment configuration uses an Al-Mg-Zn eutectic metal as the storage material, heated via heat tape wrapped around the vessel and guide tubes to bring the system to operation range (>400 °C) and to simulate charging heat exchange, respectively, with heat rejection occurring through the surfaces of the material and facilitated via guide tubes with less insulation wrapping. The model is available in the open-source repository HYBRID on Github.

25 - ENERGY STORAGE↗

Development and preliminary results of 270 GHz microwave forward scattering diagnostic system on the experimental advanced superconducting tokamak (EAST)

To measure localized (intermediate, high) poloidal wavenumber electron density fluctuations, a tangential millimeter-wave collective scattering system has been designed and successfully developed on the experimental advanced superconducting tokamak (EAST). This innovative system employs a 270 GHz mm-wave probe beam, emitted from the mid-plane of Port K and directed towards Port P after passing through a combination of two in-vessel mirrors. Here these two ports are located on the EAST device’s midplane and are 110° apart. The downward scattered signals pass through two in-vessel mirrors, and exit through the P window. The received multi-channel separated scattering signals are arranged along the poloidal direction. This optical arrangement makes the monitored turbulent wave number is poloidal dominant and up to 40 cm −1 . The tangential microwave scattering scheme enables this diagnostic to monitor local density fluctuations, with typically a radial spatial resolution △ R = 5 cm, and a wavenumber resolution of △ k = 0.4 cm −1 . The scattering system underwent comprehensive laboratory testing in 2023, with installation finalized in 2024. The system features steerable launch and receiver optics, allowing remote control to position the scattering volume from normalized radius ρ –0 to the pedestal region on a shot-by-shot basis. Effective experimental data, characterized by distinct off-center spectral peaks, have been successfully obtained in neutral beam-heated plasmas on EAST. The beam tracing forward modeling has been employed for experimental data interpretation. The advanced millimeter-wave scattering system provides fluctuation measurement capability from ion temperature gradient to electron temperature gradient scale on low field side. Preliminary experimental density fluctuation data have been successfully obtained in neutral beam-heated plasmas on EAST. The localized measurement will be used for kinetic turbulence transport numerical simulation validation.

high-k collective scattering↗

Outcomes and Conclusions from the 2022 AM Bench Measurements, Challenge Problems, Modeling Submissions, and Conference

The Additive Manufacturing Benchmark Test Series (AM Bench) provides rigorous measurement data for validating additive manufacturing (AM) simulations for a broad range of AM technologies and material systems. AM Bench includes extensive in situ and ex situ measurements, simulation challenges for the AM modeling community, and a corresponding conference series. In 2022, the second round of AM Bench measurements, challenge problems, and conference were completed, focusing primarily upon laser powder bed fusion (LPBF) processing of metals, and both material extrusion processing and vat photopolymerization of polymers. In all, more than 100 people from 10 National Institute of Standards and Technology (NIST) divisions and 21 additional organizations were directly involved in the AM Bench 2022 measurements, data management, and conference organization. The international AM community submitted 138 sets of blind modeling simulations for comparison with the in situ and ex situ measurements, up from 46 submissions for the first round of AM Bench in 2018. Analysis of these submissions provides valuable insight into current AM modeling capabilities. The AM Bench data are permanently archived and freely accessible online. The AM Bench conference also hosted an embedded workshop on qualification and certification of AM materials and components.

36 MATERIALS SCIENCE↗

Validation Studies of RELAP5-3D for High-Temperature Gas-Cooled Reactor Analysis Using a Refined RELAP5-3D Model of the High Temperature Test Facility

RELAP5-3D has been used extensively for high-temperature gas-cooled reactor (HTGR) analysis, but such analysis lies outside the validation basis for the code. Oregon State University (OSU) and the United States Department of Energy’s (DOE) Advanced Reactor Technologies (ART) – Gas-cooled reactor campaign worked together to design and operate the High Temperature Test Facility (HTTF) at OSU to provide validation data for prismatic HTGR thermal hydraulics analysis. Work using a previous RELAP5-3D model of HTTF demonstrated the ability to reproduce trends in HTTF data but an inability to reproduce the values measured in multiple experiments within the uncertainty. It was hypothesized that a new model with a finer radial nodalization would perform better for HTTF analysis. In this paper, we present the development of that more refined model and analyze HTTF experiments PG-27 and PG-29, a pressurized (PCC) and depressurized conduction cooldown (DCC) transient. Comparing PG-27 results to experimental data shows a better prediction of steady state and transient temperatures; however, a deeper dive reveals that better transient temperature predictions are a result of better initial conditions. The transient temperature rise in the core is comparable between the two models, but the legacy model predicts temperatures in the reflectors better. The new model demonstrates the ability to predict unique temperatures in each sector of the core during PG-29, capturing the azimuthal asymmetry; however, the temperature predictions still differ from measured temperatures. One hypothesis is that differences between the assumed and actual power distribution leads to the underprediction of the individual block temperatures. These results suggest that gaps and uncertainties in the measured boundary conditions for the HTTF tests do not allow to fully validate RELAP5-3D for prismatic HTGR analyses. The authors suspect that some of the differences between predicted and measured temperatures may be a result of uncertainties associated with HTTF itself rather than RELAP5-3D. We demonstrated improved validation for steady-state analysis, but significantly improved transient performance has yet to be recognized.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

FFA BEAM TRANSPORT DEMONSTRATION DEVELOPMENT FOR THE CEBAF 22 GeV UPGRADE

Jefferson Lab is planning an upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) to deliver highly polarized electron beams up to 22 GeV using Fixed- Field Alternating-gradient (FFA) magnets. As the application of FFA technology in the 10–22 GeV energy range is unprecedented, experimental validation is required prior to full-scale implementation. To support this effort, a dedicated FFA test insert is proposed within the existing CEBAF infrastructure, with candidate locations in the Beam Switchyard (BSY) dump line or the Hall C beamline. The testbed will consist of a half or full FFA cell using combined-function permanent magnets and will enable systematic studies of beam transport, field quality, alignment, and magnet performance under realistic conditions. Operation with polarized beams in the 5–11 GeV range will closely replicate the energy scaling of the full upgrade. This paper presents the current design status and layout options for the proposed FFA beam transport test line.

Ogur, S. [Thomas Jefferson National Accelerator Fa↗

Solar Radiation Measurements (CRADA Final Report)

Long-term solar radiation measurements are important for understanding solar resource availability and variability for systems design and deployment of cost-effective solar resource technologies. Additionally high-quality traceable solar measurements are required to validate satellite-based solar resource datasets that provide high-resolution long-term data covering the US. The purpose and intent of this agreement is to collect long-term solar radiation and meteorological measurements from the state-of-the-art facility at the University of Arizona to meet the above needs.

14 SOLAR ENERGY↗

Enhanced Validation of Advanced Battery Supply Chains (EVALS) Overview

EVALS is a consortium funded by the Vehicle Technologies Office at DOE involving Idaho National Lab, Argonne National Lab, and NREL. The goal of EVALS is to fully develop a suite of tools that support domestic electric vehicle manufacturing through evaluation of domestic primary resources and acceleration of their path to domestic material and battery production. This talk will focus on describing the EVALS project and discussing initial results regarding domestic LiFePO4 precursor sourcing and impacts on the domestic manufacturing supply chain.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗